  • Apparent Power Definitions in Reduced Coordinate Basis

    by Mykhailo Artemenko, Yurii Kutafin, Ivan Shapoval, Vasyl Chopyk, Valerii Mykhalskyi, Serhii Polishchuk

  • Open Access

    MODIFIED ONE-PORT EQUIVALENT CIRCUIT, EQUIVALENT TO A LINEAR ELECTRICAL AC NETWORK IN TERMS OF COMPLEX POWER, FOR OPTIMISATION AND MEASUREMENT OF ITS ENERGY CHARACTERISTICS

    by M.YU. Artemenko, Yu.V. Kutafin, V.V. Chopyk, V.M. Mikhalsky, I.A. Shapoval, S.Y. Polishchuk, С.й. Поліщук

    The article proposes a modified structure for the one-port equivalent circuit of linear electric AC networks that reproduces the complex power of the primary circuit and enables time-domain simulation in common computer software. An energy correction factor is introduced, which quantitatively characterises the decrease in the real efficiency of the primary circuit at maximum load power compared to the limit value of 50% for the classical Thevenin circuit equivalent. A one-to-one relationship of this factor with the maximum achievable efficiency of the primary circuit, which can exceed 50% at optimal load, is shown. Using the parameters of the proposed one-port equivalent circuit, analytical relations for calculating the optimal load parameters are obtained. The reliability of the theoretical results is confirmed by computer simulation in the Multisim environment on the example of a linear transformer model, which demonstrated a complete coincidence of the optimised energy characteristics of the primary AC network and its one-port equivalent circuit. References 16, figures 8.

  • One-Port COMPLEX POWER Conservative EQUIVALENT CIRCUIT OF LINEAR AC ELECTRICAL Network

    by M.YU. Artemenko, Yu.V. Kutafin, I.A. Shapoval, V.M. Mykhalskyi, V.V. Chopyk, S.Y. Polishchuk

    It has been established that the complex Thevenin’s circuit equivalent does not adequately reproduce such energy characteristics of the AC primary circuit as active power and power factor. A new one-port equivalent circuit of linear AC electrical network is proposed, which is equivalent to the primary network in terms of complex power and reproduces its complex volt-ampere characteristic on a pair of selected terminals. Analytical relationships are justified for the element parameter calculating of the proposed equivalent circuit based on the complex ZE parameters of the primary network in terms of contour currents. The results of linear AC electric network modeling in the time domain fully confirmed the adequacy of the new complex power conservative equivalent circuit structure and the analytical method for determining its parameters in reproducing the energy characteristics of the primary network in the open and closed modes of the selected terminals, as well as for a specific load. Ref. 14., fig. 8.


  • GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASIS OF A MULTIPHASE POWER SUPPLY SYSTEM

    by M.YU. Artemenko, Yu.V. Kutafin, V.V. Chopyk, V.M. Mykhalsky, I.A. Shapoval, S.Y. Polishchuk

    The paper substantiates the equivalence of determining the apparent power of a multiphase power supply system with different transmission line impedances using the Fryze-Buchholz-Deppenbrock method and on a reduced coordinate basis. Two energy-efficient control strategies for shunt active filtering in the reduced coordinate basis are proposed. The first strategy provides a unit value of the power factor, and the second strategy minimizes power losses in the transmission line while maintaining symmetry and the quasi-sinusoidal shape of the consumed currents. The advantages of using a reduced coordinate basis are a reduction in the number of sensors and key active filter regulators as well as the absence of the problem to organize the artificial grounding point for phase voltage measurements. A correction factor for the apparent power and power factor formulas was determined and verified in the presence of restrictions on the symmetrical and sinusoidal shape of the consumed currents. References 22, figures 5, tables 2.


  • Open Access

    MEASUREMENT AND COMPENSATION OF THREE-PHASE POWER SUPPLY SYSTEM INACTIVE POWERS BY SHUNT ACTIVE FILTERING

    by M.YU. Artemenko, Yu.V. Kutafin, V.V. Chopyk, V.M. Mikhalsky, I.A. Shapoval, S.Y. Polishchuk, С.й. Поліщук

    In this paper, the power theory of three-phase power supply systems was further developed by substantiating new formulas for calculating the unbalance power of three-phase four-wire power supply systems based on the measurement of active and reactive powers of individual phases, which can be used to form compensation signals in distributed active filtering with centralized control. A new structural scheme for controlling an autonomous shunt active filter with extended functionality and increased speed is proposed, which can be used in both three-wire and four-wire power supply systems. Computer modeling confirmed the adequacy of the new formulas for calculating the unbalance power components and the effectiveness of the proposed active filtering strategies to minimize power losses in the transmission line. References 11, figures 3, table 1.

  • Apparent Power and Energy Characteristics of a Multiphase Power Supply System

    by M. Yu. Artemenko, V. V. Chopyk, S. Y. Polishchuk, V. M. Mykhalskyi, I. A. Shapoval

    Increasing the power factor is one of the most important tasks of active filtering. For its successful solution, it is necessary to correctly determine the multiphase power supply system’s apparent power and active current. This paper considers a generalized case of a multiphase power supply system with different values of transmission line resistances, periodic currents and voltages of arbitrary shape. Using Schwartz’s integral inequality, applied in the reduced coordinate basis, the formulas of the apparent power and the corresponding active current in the matrix-vector form were obtained. The interdependence of the current and voltage multipliers of the apparent power formula on the transmission line resistance ratio is shown. When using energy-saving active filtering, the formulas for the minimum power loss and efficiency of a multiphase power supply system were derived. The obtained apparent power formula was compared with that given in IEEE Std. 1459-2010 for a three-phase, four-wire power supply system and the area of transmission line parameters for their convergence was established.


  • Measuring of Inactive Powers in Three-Phase Power Supply System

    by M. Yu. Artemenko, Yu. V. Kutafin, V. V. Chopyk, V. M. Mykhalskyi, I. A. Shapoval, S. Y. Polishchuk

    In the paper, a method for measuring the inactive powers of a three-phase power supply system based on operations with currents and voltages represented in the αβ - coordinate system is proposed. It is shown that measuring the four scalar powers and apparent power of a three-phase threewire system based on currents and voltages represented in the αβ-coordinate system requires four wattmeters, which is half as much as when using non-convertible values of currents and voltages. The six scalar powers of the three-phase four-wire power supply system can be determined based on the readings of six wattmeters. The experiment showed the adequacy of calculated and experimental data. Change in the nature of the load while preserving the value of the first load current harmonic does not affect the integral values of four scalar powers.


  • Identification of unbalanced power in a three-phase three-wire power system under linear loading

    by M.YU. Artemenko, Yu.V. Kutafin, I.A. Shapoval, V.V. Chopyk, V.M. Mykhalskyi, S.Y. Polishchuk

    In the paper, two orthogonal components of unbalanced power in the three-phase three-wire power supply system were introduced to simplify the distributed filtration control. Integral formulas are obtained to determine the applied unbalanced power components, making it possible to record their contribution to the deterioration of electrical energy quality. The relationship between power unbalance components and the linear unbalanced load parameters was established to verify the above-mentioned integral formulas by computer experiment. Experimental studies show complete coincidence of the measured power points with the curves of the calculated dependences. It has been found that with given source symmetric voltages, the three-phase sinusoidal process of the unbalanced load is fully identified by four scalar values: active and reactive powers and applied orthogonal components of the unbalance power. These scalar variables can be used to synthesize control signals for distributed active filters of intelligent local power grids.


  • Open Access

    THE EFFICIENCY IMPROVEMENT OF A MULTIPHASE POWER SUPPLY SYSTEM BY USING ENERGY-SAVING SHUNT ACTIVE FILTRATION STRATEGIES

    by M.Yu. Artemenko, V.V. Chopyk, V.M. Mykhalskyi, I.A. Shapoval, S.Y. Polishchuk

    Minimizing energy losses and increasing the efficiency of a multiphase power supply system by increasing the load power factor using an active shunt filter (SAF) is analyzed. Two SAF control strategies are presented, which provide the maximum efficiency at close to the unit value of power factor or at sinusoidal symmetric currents of the power supply system with any number of phases for non-sinusoidal and asymmetric sources, nonlinear and asymmetric load, and the arbitrary ratio of the resistance of linear and neutral wires. It is shown that the use of direct information about the EMF of a multiphase source as a reference vector of the desired transmission line current does not improve the achieved result of efficiency maximization. A virtual experiment obtained and verified the formula for calculating the efficiency of a multiphase power supply system with an arbitrary load in the form of dependence on load factor and power factor. The power supply system's power factor was determined and experimentally confirmed when applying the SAF strategy to form sinusoidal symmetric currents of a multiphase source. References 10, figures 5.

  • Open Access

    CONTROL STRATEGIES TO ELIMINATE HARMONICS IN POWER GENERATION SYSTEMS BASED ON A DOUBLY-FED INDUCTION GENERATOR

    by I.A. Shapoval, V.M. Mikhalsky, M.YU. Artemenko, V.V. Chopyk, S.Y. Polishchuk, С.й. Поліщук

    The variable speed power generation system based on a doubly-fed induction generator is the most popular in the wind industry. The stator is connected directly to the mains in such a generator, while the rotor is connected to the mains via a semiconductor converter. Low electric power quality increases energy and economic losses, leading to operational problems of production. Many publications discuss improving the electric power quality, particularly methods for eliminating harmonics for a power generation system based on a doubly-fed induction generator. Critical evaluation is needed to choose a method of eliminating harmonies for a particular case. The article presents an overview of different control methods for harmonic elimination in power generation systems based on a doubly-fed induction generator. Various strategies are used, which are used both in autonomous systems and in the mode of connection to the network. During the review of control methods for harmonic elimination, their different characteristics were noted, and the ad-vantages and disadvantages of each method were considered. Ref. 53, fig. 6.