    Active Currents of a Radial Three-phase Four-Wire Power System and a Distributed Active Filtering Strategy to Minimize Power Losses in the Transmission Line

    by Yurii Kutafin, Mykhailo Artemenko, Ivan Shapoval

    The active currents of a radial three-phase four-wire system were defined as the set of calculated line currents for each section of the transmission line that minimizes total power losses while ensuring the active power of each three-phase load. For the first time, using the method of Lagrange multipliers, calculation formulas for active currents of a radial three-phase four-wire system with an arbitrary number of transmission line sections were obtained. It has been proved that the minimum total power losses in the transmission line of a radial three-phase four-wire power supply system with an arbitrary number of loads is the weighted sum of these load active powers, and the weighting factors are the specified Lagrange multipliers. An iterative relationship was proposed to simplify the construction of high-order inverse matrices for determining these Lagrange multipliers. A new strategy for energy-efficient current filtering of a radial three-phase four-wire power supply system is proposed, which calculates the active currents of each network section in real time by minimizing a Lagrange function that comprises the total power losses in the transmission line and the conditions for supplying each load's active power with active currents. The proposed strategy for energy-efficient current filtering was implemented in a computer model of a three-phase four-wire power supply system with three loads and demonstrated compliance with the forecast power-saving indicators for linear and nonlinear loads, achieving more than a sevenfold reduction in power losses. The delay in the processing of dynamic disturbances is estimated at one period of the network voltage.

  • Open Access

    LOSS-MINIMIZING ACTIVE FILTERING STRATEGY FOR A THREE-PHASE FOUR-WIRE SYSTEM WITH TWO LOADS

    by Yu.V. Kutafin, M.YU. Artemenko, V.V. Chopyk, I.A. Shapoval, S.Y. Polishchuk

    The problem of energy-efficient active current filtering of multiphase power supply system with spatially distributed loads has been formulated. The optimization criterion is the minimization of the total power losses in the transmission line under conditions of zero active power of each filter’s inverter connected to the corresponding load. A new strategy for energy-efficient current filtering of a three-phase four-wire power supply system with two loads supplied from a radial transmission line with two consecutive sections is proposed, which calculates the active currents of network sections in real time by minimizing the Lagrange function composed of the total power losses in the transmission line and the conditions ensuring that the active powers of each load are supplied by active currents. It is established for the first time that the value of the minimum total power losses in the transmission line of a three-phase four-wire power supply system with two loads is the weighted sum of these load active powers with weighting coefficients in the form of calculated Lagrange multipliers. The proposed strategy for current filtering of two loads was implemented in a computer model which confirmed the predicted energy-saving performance for both linear and nonlinear loads. The settling time of the active filter parameters during dynamic changes in one of the loads is equal to one period of the mains voltage. References 15, figures 4.

  • Apparent Power Definitions in Reduced Coordinate Basis

    by Mykhailo Artemenko, Yurii Kutafin, Ivan Shapoval, Vasyl Chopyk, Valerii Mykhalskyi, Serhii Polishchuk

  • Electron activation of dyes in vacuum with their polymerisation during film growth

    by Kostyantyn Grytsenko, Yurii Kolomzarov, Demyd Pekur, Sergiy Kravchenko, Petro Lytvyn, Hanna Kashyna, Yurii Kutafin

    This research presents an integrated experimental and simulation-based study on the activation of allyl-terminated dyes using low-temperature plasma (LTP). Thin films of polymethine and heteroazulene compounds containing a terminal allyl group (allyl-terminated compounds, ATC) were produced via physical vapor deposition (PVD) under vacuum conditions. In situ optical spectra recorded during the deposition process confirmed the absence of decomposition products, indicating that the ATC molecules remain intact during growth. Atomic force microscopy (AFM) was employed to determine the influence of 3D molecular topology and chemical structure of the ATC on the resulting film morphology. To induce polymerization, the allyl groups were activated by gas-phase electrons using three distinct variants of LTP. The results indicate that the most stable and smooth films are achieved through electron activation (eA) combined with low-pressure LTP (eA+LTP). Furthermore, simulations were utilized to model the aggregation of neutral ATC molecules during PVD, as well as the specific changes in electronic structure occurring upon electron attachment. Based on these findings, an anionic polymerization mechanism is proposed.

  • Open Access

    MODIFIED ONE-PORT EQUIVALENT CIRCUIT, EQUIVALENT TO A LINEAR ELECTRICAL AC NETWORK IN TERMS OF COMPLEX POWER, FOR OPTIMISATION AND MEASUREMENT OF ITS ENERGY CHARACTERISTICS

    by M.YU. Artemenko, Yu.V. Kutafin, V.V. Chopyk, V.M. Mikhalsky, I.A. Shapoval, S.Y. Polishchuk, С.й. Поліщук

    The article proposes a modified structure for the one-port equivalent circuit of linear electric AC networks that reproduces the complex power of the primary circuit and enables time-domain simulation in common computer software. An energy correction factor is introduced, which quantitatively characterises the decrease in the real efficiency of the primary circuit at maximum load power compared to the limit value of 50% for the classical Thevenin circuit equivalent. A one-to-one relationship of this factor with the maximum achievable efficiency of the primary circuit, which can exceed 50% at optimal load, is shown. Using the parameters of the proposed one-port equivalent circuit, analytical relations for calculating the optimal load parameters are obtained. The reliability of the theoretical results is confirmed by computer simulation in the Multisim environment on the example of a linear transformer model, which demonstrated a complete coincidence of the optimised energy characteristics of the primary AC network and its one-port equivalent circuit. References 16, figures 8.

  • One-Port COMPLEX POWER Conservative EQUIVALENT CIRCUIT OF LINEAR AC ELECTRICAL Network

    by M.YU. Artemenko, Yu.V. Kutafin, I.A. Shapoval, V.M. Mykhalskyi, V.V. Chopyk, S.Y. Polishchuk

    It has been established that the complex Thevenin’s circuit equivalent does not adequately reproduce such energy characteristics of the AC primary circuit as active power and power factor. A new one-port equivalent circuit of linear AC electrical network is proposed, which is equivalent to the primary network in terms of complex power and reproduces its complex volt-ampere characteristic on a pair of selected terminals. Analytical relationships are justified for the element parameter calculating of the proposed equivalent circuit based on the complex ZE parameters of the primary network in terms of contour currents. The results of linear AC electric network modeling in the time domain fully confirmed the adequacy of the new complex power conservative equivalent circuit structure and the analytical method for determining its parameters in reproducing the energy characteristics of the primary network in the open and closed modes of the selected terminals, as well as for a specific load. Ref. 14., fig. 8.


  • OVERCOMING THE THIRD HARMONIC PROBLEM IN THE THEORY OF ACTIVE FILTRATION OF THREE-PHASE THREE-WIRE POWER SUPPLY SYSTEMS

    by M.YU. Artemenko, Yu.V. Kutafin, P.B. Fedorchenko, V.V. Chopyk, I.A. Shapoval

    In this paper the mechanism of occurrence and a quantitative assessment of the third harmonic effect in the instantane-ous active current vector of a three-phase power supply system with symmetrical sinusoidal source voltages in the pres-ence of line load asymmetry are elucidated. It is shown that additional filtering of the instantaneous reactive power pulsating component of the consumed three-phase current eliminates the problem of the third harmonic and fully corre-sponds to shunt active filtering by the integral orthogonal components of the unbalance power. A new method of shunt active filtering by integral orthogonal components of unbalance power is proposed, which uses the active and reactive powers of individual phases of a three-phase three-wire power supply system. Computer simulations have confirmed the effectiveness of the active filtering method based on the measurement of active and reactive powers of individual phases. Ref. 20, fig. 5.

  • GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASIS OF A MULTIPHASE POWER SUPPLY SYSTEM

    by M.YU. Artemenko, Yu.V. Kutafin, V.V. Chopyk, V.M. Mykhalsky, I.A. Shapoval, S.Y. Polishchuk

    The paper substantiates the equivalence of determining the apparent power of a multiphase power supply system with different transmission line impedances using the Fryze-Buchholz-Deppenbrock method and on a reduced coordinate basis. Two energy-efficient control strategies for shunt active filtering in the reduced coordinate basis are proposed. The first strategy provides a unit value of the power factor, and the second strategy minimizes power losses in the transmission line while maintaining symmetry and the quasi-sinusoidal shape of the consumed currents. The advantages of using a reduced coordinate basis are a reduction in the number of sensors and key active filter regulators as well as the absence of the problem to organize the artificial grounding point for phase voltage measurements. A correction factor for the apparent power and power factor formulas was determined and verified in the presence of restrictions on the symmetrical and sinusoidal shape of the consumed currents. References 22, figures 5, tables 2.


  • Open Access

    MEASUREMENT AND COMPENSATION OF THREE-PHASE POWER SUPPLY SYSTEM INACTIVE POWERS BY SHUNT ACTIVE FILTERING

    by M.YU. Artemenko, Yu.V. Kutafin, V.V. Chopyk, V.M. Mikhalsky, I.A. Shapoval, S.Y. Polishchuk, С.й. Поліщук

    In this paper, the power theory of three-phase power supply systems was further developed by substantiating new formulas for calculating the unbalance power of three-phase four-wire power supply systems based on the measurement of active and reactive powers of individual phases, which can be used to form compensation signals in distributed active filtering with centralized control. A new structural scheme for controlling an autonomous shunt active filter with extended functionality and increased speed is proposed, which can be used in both three-wire and four-wire power supply systems. Computer modeling confirmed the adequacy of the new formulas for calculating the unbalance power components and the effectiveness of the proposed active filtering strategies to minimize power losses in the transmission line. References 11, figures 3, table 1.

  • Open Access

    Strategies of Energy-Efficient Active Filtering in the Two Wattmeter Reference Frame

    by Yurii Viktorovych Kutafin, Mykhailo Yuhymovych Artemenko

    Such basic concepts of power theory as apparent power, active current and minimum power losses in the transmission line are defined for a three-phase three-wire system in the shortened two wattmeter reference frame. On the basis of these concepts, two energy-efficient active filtration strategies were developed and verified by virtual experiments. The first of them minimizes the power losses of a three-phase three-wire transmission line with different values of its resistances and ensures a unit value of the power factor. The second strategy follows the recommendation of IEEE Std. 1459-2010 ensures the minimum power loss of the transmission line with symmetrical sinusoidal currents of a three-phase source.