YNYoshitaka Nakao

Yoshitaka Nakao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yoshitaka Nakao has a total of 25 co-authors. Here are the top co-authors by number of shared publications:

  • Hiroshi Murata

    Tokyo, Japan

    5 shared publications
  • Yoshiaki Kiuchi

    Affiliation Ophthalmology and Visual Science Department, Hiroshima University, Hiroshima, Japan

    5 shared publications
  • Ryo Asaoka

    Affiliations Department of Ophthalmology, Seirei Hamamatsu General Hospital, Hamamatsu, Shizuoka, Japan, Seirei Christopher University, Hamamatsu, Shizuoka, Japan, The Graduate School for the Creation of New Photonics Industries, Shizuoka, Japan, Organization for Innovation and Social Collaboration, National University Corporation Shizuoka University, Hamamatsu, Shizuoka, Japan

    4 shared publications
  • Kazunori Hirasawa

    Department of Ophthalmology, Kitasato University School of Medicine, Sagamihara, Japan

    3 shared publications
  • Shunsuke Nakakura

    Department of Ophthalmology, Saneikai Tsukazaki Hospital, Hyogo, Japan

    3 shared publications
  • Yoshiaki Kiuchi

    Department of Ophthalmology and Visual Science, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan

    3 shared publications

Latest Publications

  • Open Access

    Evaluation of biomechanically corrected intraocular pressure using Corvis ST and comparison of the Corvis ST, noncontact tonometer, and Goldmann applanation tonometer in patients with glaucoma

    by Yoshitaka Nakao, Yoshiaki Kiuchi, Hideaki Okumichi

    The aim of the study was to investigate the effects of various anatomical structures on intraocular pressure (IOP) measurements obtained by the Corneal Visualization Scheimpflug Technology (Corvis ST), Goldmann applanation tonometer (GAT), and noncontact tonometer (NCT), as well as to assess the interchangeability among the four types of IOP measurement: IOP-GAT, IOP-NCT, IOP-Corvis, and biomechanically corrected IOP (bIOP-Corvis), with a particular focus on bIOP-Corvis. We included 71 patients with primary open-angle glaucoma and assessed their IOP measurements obtained with the GAT, NCT, and Corvis ST using a repeated measures ANOVA, a paired t-test with Bonferroni correction, stepwise multiple regression analyses and Bland–Altman plots. IOP-GAT showed the highest values (13.5 ± 2.1 mmHg [mean ± standard deviation]), followed by IOP-NCT (13.2 ± 2.7 mmHg), IOP-Corvis (10.6 ± 2.8 mmHg), and bIOP-Corvis (10.0 ± 2.3 mmHg). With exceptions of bIOP-Corvis and IOP-GAT, all IOP variations were explained by regression coefficients involving the central corneal thickness. Bland–Altman plots showed a mean difference between IOP-GAT and the other IOP measurements (IOP-Corvis, bIOP-Corvis, and IOP-NCT), which were -2.90, -3.48, and -0.29 mmHg, respectively. The widths of the 95% limits of agreement between all pairs of IOP measurements were greater than 3 mmHg. IOP values obtained with the Corvis ST, NCT, and GAT were not interchangeable. The bIOP-Corvis measurement corrected for the ocular structure.


  • Comment on Cataract Surgery and Rate of Visual Field Progression in Primary Open-Angle Glaucoma

    by Shuichiro Aoki, Hiroshi Murata, Shunsuke Nakakura, Yoshitaka Nakao, Masato Matsuura, Kazunori Hirasawa, Kana Tokumo, Yoshiaki Kiuchi, Ryo Asaoka


  • Changes in Corneal Biomechanics and Intraocular Pressure Following Cataract Surgery

    by Kazunori Hirasawa, Shunsuke Nakakura, Yoshitaka Nakao, Yuri Fujino, Masato Matsuura, Hiroshi Murata, Yoshiaki Kiuchi, Ryo Asaoka


  • Open Access

    Correlation between elastic energy stored in an eye and visual field progression in glaucoma

    by Shuichiro Aoki, Hiroshi Murata, Shunsuke Nakakura, Yoshitaka Nakao, Masato Matsuura, Yoshiaki Kiuchi, Ryo Asaoka

    To investigate whether the elastic energy stored in an eyeball at highest concavity (highest concavity energy; HCE), calculated with Corivs ST (CST, OCULUS), correlates with glaucomatous visual field (VF) progression. 108 eyes from 70 primary open angle-glaucoma patients were studied. The HCE was calculated using CST parameters. For each eye, the mean total deviation (mTD) of the 52 test points in the 24–2 Humphrey Field Analyzer test pattern was calculated and the mTD progression rate was determined from eight reliable VFs. Eyes were subdivided into: subgroups with low- or high-whole eye motion maximal length (WEM-d) and subgroups with short- or long-time taken to reach WEM-d (WEM-t), as measured with CST. The associations between mTD progression rate and HCE and other ocular/systemic parameters including age, Goldmann applanation tonometry based-intraocular pressure [GAT-IOP], and corneal hysteresis [CH] from the Ocular Response Analyzer (ORA®, Reichert) were investigated using the linear mixed model. The optimal model to describe mTD progression rate was selected from all possible combinations according to the second order bias corrected Akaike Information Criterion index. Optimal models to describe mTD progression rate included: CH in the model for all eyes, age and HCE in the model for the WEM-d low group, HCE in the model for the WEM-t short group, mean GAT-IOP in the model for the WEM-d high group, and age in the model for the WEM-t long-group. HCE was associated with glaucomatous VF progression in eyes with minimal whole eye motion (low WEM-d and WEM-t subgroups).


  • Open Access

    A Comparison of the Corrected Intraocular Pressure Obtained by the Corvis ST and Reichert 7CR Tonometers in Glaucoma Patients

    by Yoshitaka Nakao, Yoshiaki Kiuchi, Satoshi Okimoto

    The purpose of the study was to investigate the accuracy of two corrected intraocular pressure (IOP) measurements by Corvis Scheimpflug Technology (CST)-IOPpachy and by corneal-compensated IOP (IOPcc) using the Reichert 7CR (7CR) tonometers. We also investigated the effects of corneal anatomical and structural parameters on the IOP measurements. The participants included 90 primary open-angle glaucoma patients. We assessed the IOP measurements, obtained by the CST, 7CR, and Goldmann applanation tonometer (GAT), using a paired t-test with Bonferroni correction, Bland-Altman plots, and multiple regression analyses. The 7CR-IOPcc gave the highest value (15.5 ± 2.7 mmHg), followed by the 7CR-IOPg (13.7 ± 3.1 mmHg), GAT-IOP (13.6 ± 2.2 mmHg), CST-IOP (10.3 ± 2.6 mmHg), and CST-IOPpachy (9.7 ± 2.5 mmHg). The values of CST-IOPpachy were significantly lower than those obtained by the other IOP measurement methods (all, p < 0.01). The values of 7CR-IOPcc were significantly higher than those obtained by the other IOP measurement methods (all, p < 0.01). Bland-Altman plots showed a mean difference between the GAT-IOP and the other IOP measurements (CST-IOP, CST-IOPpachy, 7CR-IOPg, and 7CR-IOPcc), which were −3.20, −3.82, 0.14, and 2.00 mmHg, respectively. The widths of the 95% limits of agreement between all pairs of IOP measurements were greater than 3 mmHg. With the exception of the 7CR-IOPcc, all of the IOP variations were explained by regression coefficients involving gender, average corneal curvature, and central corneal thickness. The IOP values obtained by the GAT, CST, and 7CR were not interchangeable. Each new IOP measurement device that was corrected for ocular structure had its own limitations.


  • Open Access

    The Relationship between Corvis ST Tonometry and Ocular Response Analyzer Measurements in Eyes with Glaucoma

    by Masato Matsuura, Kazunori Hirasawa, Hiroshi Murata, Mieko Yanagisawa, Yoshitaka Nakao, Shunsuke Nakakura, Yoshiaki Kiuchi, Ryo Asaoka

    It is important to compare the results of Corneal Visualization Scheimpflug Technology instrument (CST) measurements and Reichert Ocular Response Analyzer (ORA) parameters. The purpose of the study was to investigate the association between CST measurements and ORA parameters in ninety-five patients with primary open-angle glaucoma. Measurements of CST, ORA, axial length (AL), average corneal curvature (CC), central corneal thickness (CCT) and intraocular pressure (IOP) with Goldmann applanation tonometry (GAT) were carried out. The association between CST and ORA parameters was assessed using linear regression analysis, with model selection based on the second order bias corrected Akaike Information Criterion index. Measurements from ORA (corneal hysteresis [CH] and corneal response factor [CRF]) had high intraclass correlation coefficients (ICC) and low coefficients of variation, but some CST parameters showed much lower reproducibility, namely: A1 length, A2 length, highest concavity time and peak distance. Of 12 CST parameters tested, 8 were significantly correlated with CH and 10 were significantly correlated with CRF, however, the magnitude of the correlation coefficients were weak to moderate at best. The optimal model to explain CH using CST measurements was given by: CH = -76.3 + 4.6*A1 time + 1.9*A2 time + 3.1 * highest concavity deformation amplitude + 0.016*CCT (R2 = 0.67, p 2 = 0.73, p <0.001). ORA parameters show higher reproducibility than CST measurements. Although many CST parameters are significantly related to ORA parameters, the strengths of these relationships are weak to moderate.


    • 1 April 2016
      • Vol. 120  (4) , 303-9

    [Stereoacuity in Glaucoma Patients].

    by Tomoko Yoshikawa, Yoshitaka Nakao, Yoshiaki Kiuchi

    Studies report that glaucoma significantly affects stereoacuity. We investigated the stereoacuity in glaucoma and preperimetric glaucoma patients. The near stereoacuity in glaucoma patients and preperimetric glaucoma patients was evaluated using Titmus stereo test, and distance stereoacuity was evaluated using Distance Randot stereotest. We found a significant reduction both in near and in distance stereoacuity in the glaucoma group compared with the control group, but the difference between the preperimetric glaucoma group and the control group were not significant. We observed a trend of decrease in near stereoacuity with increase in age and increased number of central scotoma cases, as well as a trend of decrease in distance stereoacuity with increased age. The near and distance stereoacuity in glaucoma patients was significantly impaired. Our results suggest that visual field damage within the central 5 degrees may affect the near stereoacuity in glaucoma patients.


  • Open Access

    The Relationship between Corvis ST Tonometry Measured Corneal Parameters and Intraocular Pressure, Corneal Thickness and Corneal Curvature

    by Ryo Asaoka, Shunsuke Nakakura, Hitoshi Tabuchi, Hiroshi Murata, Yoshitaka Nakao, Noriko Ihara, Ulfah Rimayanti, Makoto Aihara, Yoshiaki Kiuchi

    The purpose of the study was to investigate the correlation between Corneal Visualization Scheimpflug Technology (Corvis ST tonometry: CST) parameters and various other ocular parameters, including intraocular pressure (IOP) with Goldmann applanation tonometry. IOP with Goldmann applanation tonometry (IOP-G), central corneal thickness (CCT), axial length (AL), corneal curvature, and CST parameters were measured in 94 eyes of 94 normal subjects. The relationship between ten CST parameters against age, gender, IOP-G, AL, CST-determined CCT and average corneal curvature was investigated using linear modeling. In addition, the relationship between IOP-G versus CST-determined CCT, AL, and other CST parameters was also investigated using linear modeling. Linear modeling showed that the CST measurement ‘A time-1’ is dependent on IOP-G, age, AL, and average corneal curvature; ‘A length-1’ depends on age and average corneal curvature; ‘A velocity-1’ depends on IOP-G and AL; ‘A time-2’ depends on IOP-G, age, and AL; ‘A length-2’ depends on CCT; ‘A velocity-2’ depends on IOP-G, age, AL, CCT, and average corneal curvature; ‘peak distance’ depends on gender; ‘maximum deformation amplitude’ depends on IOP-G, age, and AL. In the optimal model for IOP-G, A time-1, A velocity-1, and highest concavity curvature, but not CCT, were selected as the most important explanatory variables. In conclusion, many CST parameters were not significantly related to CCT, but IOP usually was a significant predictor, suggesting that an adjustment should be made to improve their usefulness for clinical investigations. It was also suggested CST parameters were more influential for IOP-G than CCT and average corneal curvature.


  • Prevalence and anatomic mechanism of highly myopic strabismus among Japanese with severe myopia

    by Yoshitaka Nakao, Tohru Kimura

    To survey the prevalence of highly myopic strabismus among patients with severe myopia and to elucidate its anatomic mechanism. The subjects (mean age 48.5 ± 17.8 years) were 452 Japanese patients (778 eyes) who presented between May 2011 and April 2012 and were diagnosed as severely myopic (objective refractive error ≥−6.00 D or axial length ≥27 mm). For diagnosis, the eye position at 0.33 m, axial length, and diagnostic positions of gaze were determined; magnetic resonance imaging (MRI) was also used. Sixteen eyes of 9 patients fulfilled the disease criteria, and strabismus fixus was observed for 3 eyes of 3 patients. Disease prevalence was 2.65 %. The mean age of the 12 patients was 65.5 ± 17.9 years. For 18 eyes for which the axial length could be measured, mean axial length was 28.9 ± 2.03 mm. For the 16 eyes examined by MRI the mean dislocation angle was 132° ± 14.0°. The axial length was 26 to <30 mm for 13 of the 16 eyes, dislocation angle was 110° to <150° for 14 eyes, and both axial length and dislocation angle were within these ranges for 12 eyes. The prevalence of the disease was 2.65 %. However, this was not a general epidemiological survey and the screening criteria did not adequately cover all disease cases. In addition, even for eyes that are still mildly–moderately myopic, this disease can develop in the presence of orbital pulley abnormalities.


  • A Case of Highly Myopic Strabismus With An Onset Age at Ten

    by Yoshitaka Nakao, Yoshiko Okada, Tohru Kimura, Shirou Ozaki, Sanae Muraki