Cuthbert Nyamupangedengu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Cuthbert Nyamupangedengu has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Neil John Coville
Molecular Sciences Institute, School of Chemistry, University of the Witwatersrand, Johannesburg, 2050, South Africa
2 shared publications - Andrew M. Hank
University of the Witwatersrand
1 shared publication - Anthony Novell
Université Paris-Saclay, CEA, CNRS, Inserm, BioMaps, SHFJ, Orsay 91401, France
1 shared publication - Ayache Bouakaz
UMR 1253, iBrain, Université de Tours, Inserm, France
1 shared publication - Bonginkosi Mpinga
Faculty of Engineering and the Built Environment, School of Electrical and Information Engineering, University of the Witwatersrand, Johannesburg 2017, South Africa
1 shared publication - Bridget K. Mutuma
Department of Chemistry, University of Nairobi, P. O. Box 30197-00100, Nairobi, Kenya
1 shared publication
Latest Publications
- Open Access
- 15 June 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 140 (1) , 66
Using Tan Delta and Dielectric Constant as Criterion for the Selection of Suitable Insulation Materials for HV Cable Joints
High-voltage cable joints are critical components where electric stress concentration often leads to insulation failure. This study evaluated three materials to find optimal configurations for controlling stress in 33 kV applications: PVC tape, stress-grading mastic, and semiconductive rubber tape, with initial relative permittivities of 2.96, 2.66, and 5.07, respectively. Dielectric measurements using a Schering Bridge at voltages of up to 3700 V determined material properties and breakdown characteristics. Semiconductive rubber withstood the highest voltage of 3700 V, while mastic failed at 1350 V. Finite element simulations showed that baseline configurations without proper insulation had a peak stress of 4.3 kV/mm. Simulations of individual materials identified non-linear resistive compounds, such as ZnO-based materials and carbon-black-filled polymers, as the most effective for stress control at conductor interfaces. A three-layer graded design, arranging materials by decreasing permittivity from the conductor outward, reduced the peak stress by 33% to 2.9 kV/mm. These results demonstrate that strategic permittivity grading combined with appropriate material selection ensures uniform field distribution and improved reliability in HV cable joints.
- 15 June 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 140 (1) , 66
Open AccessUsing Tan Delta and Dielectric Constant as Criterion for the Selection of Suitable Insulation Materials for HV Cable Joints
High-voltage cable joints are critical components where electric stress concentration often leads to insulation failure. This study evaluated three materials to find optimal configurations for controlling stress in 33 kV applications: PVC tape, stress-grading mastic, and semiconductive rubber tape, with initial relative permittivities of 2.96, 2.66, and 5.07, respectively. Dielectric measurements using a Schering Bridge at voltages of up to 3700 V determined material properties and breakdown characteristics. Semiconductive rubber withstood the highest voltage of 3700 V, while mastic failed at 1350 V. Finite element simulations showed that baseline configurations without proper insulation had a peak stress of 4.3 kV/mm. Simulations of individual materials identified non-linear resistive compounds, such as ZnO-based materials and carbon-black-filled polymers, as the most effective for stress control at conductor interfaces. A three-layer graded design, arranging materials by decreasing permittivity from the conductor outward, reduced the peak stress by 33% to 2.9 kV/mm. These results demonstrate that strategic permittivity grading combined with appropriate material selection ensures uniform field distribution and improved reliability in HV cable joints.
- Open Access
- 24 February 2023
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 8 (3) , 622-629
Residual charge effects on partial discharges' response to varying sub‐kHz voltage frequencies
Partial discharges (PD) are the ‘cancer’ of electrical insulation. Insulation design and mitigation of PD‐induced degradation should be based on good knowledge of PD phenomena. In that regard, a significant body of knowledge has been built up from concerted research across the world in past decades and on various aspects of PD phenomena under various conditions. However, the work is far from being complete as new challenges arise. One such challenge is that electric power equipment insulation is becoming more exposed to non‐power frequency voltages. Examples are the proliferation of invertor‐based grid‐tied renewable energy sources and other technologies such as high‐frequency power electronic transformers. Questions that are driving continued research in this regard include the reasons for lack of consensus on the findings on how PD characteristics respond to variations in the voltage frequency. This paper presents results of how residual charge influences PD characteristics' response to voltage frequency changes from 1 to 200 Hz. The study approach is implementing the extended 3‐capacitor PD model in MATLAB ® Simulink ® and validating the findings using the relevant experimental results that are available in literature. The PD type studied is that of an air cavity encapsulated in a polyethylene dielectric. Highlights of the findings are that the extent of the influence of residual charge on PD characteristics depends on the relative magnitude of the residual charge as well as the voltage frequency. The relationships however exhibit non‐monotonous trends. Such results further confirm similar findings and conclusions by other researchers and could be signalling the establishment of a more solid knowledge base for design of insulations that operate at non‐power frequencies.
- 24 February 2023
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 8 (3) , 622-629
Open AccessResidual charge effects on partial discharges' response to varying sub‐kHz voltage frequencies
Partial discharges (PD) are the ‘cancer’ of electrical insulation. Insulation design and mitigation of PD‐induced degradation should be based on good knowledge of PD phenomena. In that regard, a significant body of knowledge has been built up from concerted research across the world in past decades and on various aspects of PD phenomena under various conditions. However, the work is far from being complete as new challenges arise. One such challenge is that electric power equipment insulation is becoming more exposed to non‐power frequency voltages. Examples are the proliferation of invertor‐based grid‐tied renewable energy sources and other technologies such as high‐frequency power electronic transformers. Questions that are driving continued research in this regard include the reasons for lack of consensus on the findings on how PD characteristics respond to variations in the voltage frequency. This paper presents results of how residual charge influences PD characteristics' response to voltage frequency changes from 1 to 200 Hz. The study approach is implementing the extended 3‐capacitor PD model in MATLAB ® Simulink ® and validating the findings using the relevant experimental results that are available in literature. The PD type studied is that of an air cavity encapsulated in a polyethylene dielectric. Highlights of the findings are that the extent of the influence of residual charge on PD characteristics depends on the relative magnitude of the residual charge as well as the voltage frequency. The relationships however exhibit non‐monotonous trends. Such results further confirm similar findings and conclusions by other researchers and could be signalling the establishment of a more solid knowledge base for design of insulations that operate at non‐power frequencies.
- Open Access
The Influence of Diethylaniline and Toluene on the Streamer Propagation in Cyclohexane between a Point-Plane Gap under Positive Impulse Voltage Stress
Liquid insulation is used in high voltage equipment such as power transformers as both dielectric medium and coolant. Breakdown in liquid insulation tends to be governed either by streamer initiation under more uniform fields, or by streamer propagation under more non-uniform fields. A model streamer propagation study, which screens the effectiveness of additives based on cyclohexane and mixtures with diethylaniline (DEA) and toluene, is presented in this paper. The effect of additives, at different concentrations, on streamer propagation velocity in cyclohexane under an applied lightning impulse voltage of positive polarity is studied. Cyclohexane (ionisation potential 9.88 eV) was chosen because, being a hydrocarbon, it shares similarities with the constituents of common insulating liquids. Previous studies have also shown how, in general, the addition of additives of lower ionization potential than the bulk liquid can slow down streamer propagation in insulating liquids. A point-plane electrode configuration of 70 mm gap with a 5 μm tip radius is used and subjected to an applied positive polarity impulse of 1.2/50 μs. A high velocity imaging system is also used to capture streamer images to validate a Time-To-Breakdown (TTB) measurement approach used in inferring approximate streamer velocity. The DEA (ionisation potential 6.98 eV) was found to be an effective additive to slow down positive polarity streamers in cyclohexane in the applied voltage range (≈220–280 kV peak) in concentrations above approximately 0.33% (by volume). Toluene (ionisation potential 8.82 eV) was found not to significantly slow down streamers in cyclohexane, even at 10% concentration, for the same voltage range. This is postulated to be due to the fact that toluene does not have a low enough ionisation potential (with respect to that of the cyclohexane) to change the streamer branching characteristics sufficiently during propagation.
Open AccessThe Influence of Diethylaniline and Toluene on the Streamer Propagation in Cyclohexane between a Point-Plane Gap under Positive Impulse Voltage Stress
Liquid insulation is used in high voltage equipment such as power transformers as both dielectric medium and coolant. Breakdown in liquid insulation tends to be governed either by streamer initiation under more uniform fields, or by streamer propagation under more non-uniform fields. A model streamer propagation study, which screens the effectiveness of additives based on cyclohexane and mixtures with diethylaniline (DEA) and toluene, is presented in this paper. The effect of additives, at different concentrations, on streamer propagation velocity in cyclohexane under an applied lightning impulse voltage of positive polarity is studied. Cyclohexane (ionisation potential 9.88 eV) was chosen because, being a hydrocarbon, it shares similarities with the constituents of common insulating liquids. Previous studies have also shown how, in general, the addition of additives of lower ionization potential than the bulk liquid can slow down streamer propagation in insulating liquids. A point-plane electrode configuration of 70 mm gap with a 5 μm tip radius is used and subjected to an applied positive polarity impulse of 1.2/50 μs. A high velocity imaging system is also used to capture streamer images to validate a Time-To-Breakdown (TTB) measurement approach used in inferring approximate streamer velocity. The DEA (ionisation potential 6.98 eV) was found to be an effective additive to slow down positive polarity streamers in cyclohexane in the applied voltage range (≈220–280 kV peak) in concentrations above approximately 0.33% (by volume). Toluene (ionisation potential 8.82 eV) was found not to significantly slow down streamers in cyclohexane, even at 10% concentration, for the same voltage range. This is postulated to be due to the fact that toluene does not have a low enough ionisation potential (with respect to that of the cyclohexane) to change the streamer branching characteristics sufficiently during propagation.
- 25 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Partial Discharge Characterization of Electrical Trees in Epoxy Insulation
This paper presents a study of electrical trees partial discharges in three different epoxy resins namely, RPU315, FR/974/SF and FR/64 that are commonly used in power cable accessories. The work is motivated by problems recently experienced in a case of mining machinery where high voltage power cable connectors using RPU315 epoxy had consistently prematurely failed. It was therefore needed to evaluate the insulation strength of the epoxy in question relative to other epoxy types that are used in power cable accessories. Electrical treeing is a pre-breakdown phenomenon in solid insulation such as epoxy resins, rubbers, and polymers. The electrical tree partial discharges are measured using a partial discharge measurement set-up in accordance with the IEC60270 standard. Partial discharge characteristics are observed as the electrical trees grow from inception, propagation through to breakdown. The classical point-to-plane electrode configuration cast in the epoxy is used to simulate a defect inside the epoxy resin creating an intense localized stressed region. The characteristics showed that the electrical tree inception occurred at the lowest voltage of 1.43 kV in RPU315 epoxy showing that it is the weakest of the three epoxies studied. The strongest epoxy proved to be the FR/974/SF with an electrical tree inception voltage of 1.70 kV. It was found that the phase-resolved partial discharge patterns of RPU315, FR/974/SF, and FR/64 epoxies represented bush type, branch-type, and bush-branch type tree structures respectively. Bush trees manifest the presence of multiple paths for partial discharge activity and fast deterioration, whereas branch-type trees represent fewer paths for partial discharge activity to grow in the insulation. Among the three types of epoxies investigated, the FR/974/SF epoxy is found to be the most durable type as it has the highest electrical tree inception voltage meaning that it sustains electrical treeing PD activity much longer.
- 25 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Partial Discharge Characterization of Electrical Trees in Epoxy Insulation
This paper presents a study of electrical trees partial discharges in three different epoxy resins namely, RPU315, FR/974/SF and FR/64 that are commonly used in power cable accessories. The work is motivated by problems recently experienced in a case of mining machinery where high voltage power cable connectors using RPU315 epoxy had consistently prematurely failed. It was therefore needed to evaluate the insulation strength of the epoxy in question relative to other epoxy types that are used in power cable accessories. Electrical treeing is a pre-breakdown phenomenon in solid insulation such as epoxy resins, rubbers, and polymers. The electrical tree partial discharges are measured using a partial discharge measurement set-up in accordance with the IEC60270 standard. Partial discharge characteristics are observed as the electrical trees grow from inception, propagation through to breakdown. The classical point-to-plane electrode configuration cast in the epoxy is used to simulate a defect inside the epoxy resin creating an intense localized stressed region. The characteristics showed that the electrical tree inception occurred at the lowest voltage of 1.43 kV in RPU315 epoxy showing that it is the weakest of the three epoxies studied. The strongest epoxy proved to be the FR/974/SF with an electrical tree inception voltage of 1.70 kV. It was found that the phase-resolved partial discharge patterns of RPU315, FR/974/SF, and FR/64 epoxies represented bush type, branch-type, and bush-branch type tree structures respectively. Bush trees manifest the presence of multiple paths for partial discharge activity and fast deterioration, whereas branch-type trees represent fewer paths for partial discharge activity to grow in the insulation. Among the three types of epoxies investigated, the FR/974/SF epoxy is found to be the most durable type as it has the highest electrical tree inception voltage meaning that it sustains electrical treeing PD activity much longer.
- Open Access
Improving Thermal Stability and Hydrophobicity of Rutile-TiO2 Nanoparticles for Oil-Impregnated Paper Application
Thermal stress and moisture absorption can cause a synergetic negative impact on kraft paper. Among various approaches for improving the dielectric properties of kraft paper, nanotechnology has had promising results. However, the hydrophilicity of most metal oxide nanoparticles renders nanomodified kraft paper more vulnerable to thermal stress and moisture, thereby inducing degradation. In nanomodified kraft paper research, the use of TiO2 nanoparticles has yielded the most promising results. The major shortfall, however, is the hydrophilicity of TiO2. This work investigated surface modifications of rutile-TiO2 nanoparticles (NPs) for improved hydrophobicity and thermal stability. Rutile-TiO2 NPs is a nontoxic metal oxide that can withstand high temperature and is stable in chemical reactions. Two cases of surfactants were used—alkyl ketene dimer (AKD) and alkenyl succinic anhydride (ASA). The intention was to increase heat resistance and reduce the surface free energy of the rutile-TiO2 NPs. The impacts of the surface modifiers on the rutile-TiO2 NPs were characterised using FT-IR, muffle furnace, analytical weight balance, and TGA. It was discovered that new functional groups were formed on the modified NPs examined through FT-IR spectra. This indicates new chemical bonds, introduced through the surface modification. The unmodified rutile-TiO2 NPs absorbed moisture, increasing their mass by 3.88%, compared with the modified nanoparticles, which released moisture instead. TGA analysis revealed that AKD- and ASA-modified rutile-TiO2 needed higher temperatures than the unmodified rutile-TiO2 to markedly decompose. AKD, however, gave better performance than ASA in that regard. As an example, those modified with 5% AKD sustained a 45% higher temperature than the pure TiO2 nanoparticles. Furthermore, in both cases of the surfactants, the higher the percent of surfactant content was, the more thermally stable the nanoparticles became. This work demonstrates the possibility of fabricating rutile-TiO2 NPs to give improved hydrophobicity and thermal stability for possible dielectric applications such as in kraft paper for power transformer insulation.
Open AccessImproving Thermal Stability and Hydrophobicity of Rutile-TiO2 Nanoparticles for Oil-Impregnated Paper Application
Thermal stress and moisture absorption can cause a synergetic negative impact on kraft paper. Among various approaches for improving the dielectric properties of kraft paper, nanotechnology has had promising results. However, the hydrophilicity of most metal oxide nanoparticles renders nanomodified kraft paper more vulnerable to thermal stress and moisture, thereby inducing degradation. In nanomodified kraft paper research, the use of TiO2 nanoparticles has yielded the most promising results. The major shortfall, however, is the hydrophilicity of TiO2. This work investigated surface modifications of rutile-TiO2 nanoparticles (NPs) for improved hydrophobicity and thermal stability. Rutile-TiO2 NPs is a nontoxic metal oxide that can withstand high temperature and is stable in chemical reactions. Two cases of surfactants were used—alkyl ketene dimer (AKD) and alkenyl succinic anhydride (ASA). The intention was to increase heat resistance and reduce the surface free energy of the rutile-TiO2 NPs. The impacts of the surface modifiers on the rutile-TiO2 NPs were characterised using FT-IR, muffle furnace, analytical weight balance, and TGA. It was discovered that new functional groups were formed on the modified NPs examined through FT-IR spectra. This indicates new chemical bonds, introduced through the surface modification. The unmodified rutile-TiO2 NPs absorbed moisture, increasing their mass by 3.88%, compared with the modified nanoparticles, which released moisture instead. TGA analysis revealed that AKD- and ASA-modified rutile-TiO2 needed higher temperatures than the unmodified rutile-TiO2 to markedly decompose. AKD, however, gave better performance than ASA in that regard. As an example, those modified with 5% AKD sustained a 45% higher temperature than the pure TiO2 nanoparticles. Furthermore, in both cases of the surfactants, the higher the percent of surfactant content was, the more thermally stable the nanoparticles became. This work demonstrates the possibility of fabricating rutile-TiO2 NPs to give improved hydrophobicity and thermal stability for possible dielectric applications such as in kraft paper for power transformer insulation.
- Open Access
Analysis of Cavity PD Characteristics’ Sensitivity to Changes in the Supply Voltage Frequency
The supply voltage frequency effect on partial discharge (PD) phenomena has continued to draw research interest. Although most high voltage equipment operates at power frequency (50/60 Hz), testing is often done at different frequencies for various reasons. Despite some agreements and inconsistencies for the research findings of PD activity’s frequency dependence, there has been consensus on the recognition of the discharge mechanism parameters that influence how the supply voltage frequency affects PD activity. These parameters include statistical time lag, discharge area surface conductivity, and the residual charge decay. In this paper, a 3-capacitor model (ABC) is used to simulate how the changes in the discharge mechanism parameters influence PD characteristics as a function of the supply voltage frequency. The findings are that the phase-resolved partial discharge pattern (PRPDP) and PD repetition rate (PDRR) characteristics are more sensitive to variations in the probability of the seed electron availability at higher frequencies of the supply voltage. The opposite trend is observed for the cavity surface resistance. At lower resistance of cavity surface, the PRPDP and PDRR characteristics are more sensitive to changes in the supply voltage frequency than at higher resistances. The paper also confirms that incorporating equivalent resistances in the ABC model makes it more authentic than the model comprising of capacitors only.
Open AccessAnalysis of Cavity PD Characteristics’ Sensitivity to Changes in the Supply Voltage Frequency
The supply voltage frequency effect on partial discharge (PD) phenomena has continued to draw research interest. Although most high voltage equipment operates at power frequency (50/60 Hz), testing is often done at different frequencies for various reasons. Despite some agreements and inconsistencies for the research findings of PD activity’s frequency dependence, there has been consensus on the recognition of the discharge mechanism parameters that influence how the supply voltage frequency affects PD activity. These parameters include statistical time lag, discharge area surface conductivity, and the residual charge decay. In this paper, a 3-capacitor model (ABC) is used to simulate how the changes in the discharge mechanism parameters influence PD characteristics as a function of the supply voltage frequency. The findings are that the phase-resolved partial discharge pattern (PRPDP) and PD repetition rate (PDRR) characteristics are more sensitive to variations in the probability of the seed electron availability at higher frequencies of the supply voltage. The opposite trend is observed for the cavity surface resistance. At lower resistance of cavity surface, the PRPDP and PDRR characteristics are more sensitive to changes in the supply voltage frequency than at higher resistances. The paper also confirms that incorporating equivalent resistances in the ABC model makes it more authentic than the model comprising of capacitors only.
- 20 May 2020
- Published by Trans Tech Publications, Ltd. in International Journal of Engineering Research in Africa
- Vol. 48, 24-37
Comparative Characterisation of CNS/Epoxy and BN/Epoxy Nanodielectrics Using Electrical Tree PD Measurements and Atomic Force Microscopy
This paper contributes to the body of knowledge on the efforts to develop nanodielectrics as the next generation of insulation material. The time-to-failure under electrical tree-induced degradation of 1.09-1.35 vol.% hexagonal BN/Epoxy was found to be 3 times longer than in clean epoxy. For 0.31-0.33 vol.% CNS/Epoxy the time-to-failure was 24 times longer than the clean epoxy. The electrical treeing partial discharge behaviour in the BN/Epoxy and CNS/Epoxy showed distinct time-evolution characteristics different from those in the clean epoxy. The improved electrical tree endurance in BN/Epoxy relative to the clean epoxy can be attributed to increased mechanical stiffness. The superiority of the CNS/Epoxy as a nanodielectric is notable. The effect is suggested to be due to the electron affinity properties of the carbon nanospheres at appropriate dispersion levels.
- 20 May 2020
- Published by Trans Tech Publications, Ltd. in International Journal of Engineering Research in Africa
- Vol. 48, 24-37
Comparative Characterisation of CNS/Epoxy and BN/Epoxy Nanodielectrics Using Electrical Tree PD Measurements and Atomic Force Microscopy
This paper contributes to the body of knowledge on the efforts to develop nanodielectrics as the next generation of insulation material. The time-to-failure under electrical tree-induced degradation of 1.09-1.35 vol.% hexagonal BN/Epoxy was found to be 3 times longer than in clean epoxy. For 0.31-0.33 vol.% CNS/Epoxy the time-to-failure was 24 times longer than the clean epoxy. The electrical treeing partial discharge behaviour in the BN/Epoxy and CNS/Epoxy showed distinct time-evolution characteristics different from those in the clean epoxy. The improved electrical tree endurance in BN/Epoxy relative to the clean epoxy can be attributed to increased mechanical stiffness. The superiority of the CNS/Epoxy as a nanodielectric is notable. The effect is suggested to be due to the electron affinity properties of the carbon nanospheres at appropriate dispersion levels.
- 31 October 2019
- Published by Springer Nature
- p. 1303-1313
Comparing Electrical Tree Inception in Epoxy and Polyethylene Using Fowler-Nordheim Based Model
- 31 October 2019
- Published by Springer Nature
- p. 1303-1313
Comparing Electrical Tree Inception in Epoxy and Polyethylene Using Fowler-Nordheim Based Model
- Open Access
Ultrasonic identification technique in recycling of lithium ion batteries
The recycling of lithium ion batteries has been mentioned as one of the near-future waste management necessities. In order for recycling to be economically viable, straightforward and cost effective techniques need to be developed to separate the individual materials in a composite electrode. Ultrasonic separation might be such a technique, provided that lithium ion battery microparticles respond predictably to a sound field. Lithium ion battery cathodes contain hydrophobic carbon. Owing to the incompressibility of a solid, the thin gaseous layer surrounding these hydrophobic particles must oscillate asymmetrically, when subjected to ultrasound. Consequently, the harmonic content of the ultrasound signal radiated from hydrophobic microparticles must be higher than that from hydrophilic microparticles with the same size. The question of whether the harmonic signal response generated by physical hydrophobic microparticles present in lithium ion battery cathodes is higher than the harmonic response of other component materials in the cathode is the focus of this paper. The scattering response of cathode materials subjected to 1-MHz ultrasound was measured and compared. The cathode materials C65, PVDF, and NMC respond differently to 1-MHz ultrasound. The superharmonic response of C65 has been attributed to asymmetric oscillations owing to its hydrophobicity. In addition, C65 hydrophobic microparticles might be suitable candidates for harmonic imaging.
Open AccessUltrasonic identification technique in recycling of lithium ion batteries
The recycling of lithium ion batteries has been mentioned as one of the near-future waste management necessities. In order for recycling to be economically viable, straightforward and cost effective techniques need to be developed to separate the individual materials in a composite electrode. Ultrasonic separation might be such a technique, provided that lithium ion battery microparticles respond predictably to a sound field. Lithium ion battery cathodes contain hydrophobic carbon. Owing to the incompressibility of a solid, the thin gaseous layer surrounding these hydrophobic particles must oscillate asymmetrically, when subjected to ultrasound. Consequently, the harmonic content of the ultrasound signal radiated from hydrophobic microparticles must be higher than that from hydrophilic microparticles with the same size. The question of whether the harmonic signal response generated by physical hydrophobic microparticles present in lithium ion battery cathodes is higher than the harmonic response of other component materials in the cathode is the focus of this paper. The scattering response of cathode materials subjected to 1-MHz ultrasound was measured and compared. The cathode materials C65, PVDF, and NMC respond differently to 1-MHz ultrasound. The superharmonic response of C65 has been attributed to asymmetric oscillations owing to its hydrophobicity. In addition, C65 hydrophobic microparticles might be suitable candidates for harmonic imaging.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in SAIEE Africa Research Journal
- Vol. 110 (3) , 110
Guest Editorial
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in SAIEE Africa Research Journal
- Vol. 110 (3) , 110
Guest Editorial