Andrew M. Hank
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andrew M. Hank has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Bridget K. Mutuma
Department of Chemistry, University of Nairobi, P. O. Box 30197-00100, Nairobi, Kenya
1 shared publication - Cuthbert Nyamupangedengu
Faculty of Engineering and the Built Environment, School of Electrical and Information Engineering, University of the Witwatersrand, Johannesburg 2017, South Africa
1 shared publication - Hu Li
Shandong University
1 shared publication Iakovos Sigalas
University of the Witwatersrand
1 shared publication- Klaus Leifer
Ångström Laboratory, Department of Materials Science and Engineering, Uppsala University, 75121 Uppsala, Sweden
1 shared publication - Neil John Coville
Molecular Sciences Institute, School of Chemistry, University of the Witwatersrand, Johannesburg, 2050, South Africa
1 shared publication
Latest Publications
- 20 May 2020
- Published by Trans Tech Publications, Ltd. in International Journal of Engineering Research in Africa
- Vol. 48, 24-37
Comparative Characterisation of CNS/Epoxy and BN/Epoxy Nanodielectrics Using Electrical Tree PD Measurements and Atomic Force Microscopy
This paper contributes to the body of knowledge on the efforts to develop nanodielectrics as the next generation of insulation material. The time-to-failure under electrical tree-induced degradation of 1.09-1.35 vol.% hexagonal BN/Epoxy was found to be 3 times longer than in clean epoxy. For 0.31-0.33 vol.% CNS/Epoxy the time-to-failure was 24 times longer than the clean epoxy. The electrical treeing partial discharge behaviour in the BN/Epoxy and CNS/Epoxy showed distinct time-evolution characteristics different from those in the clean epoxy. The improved electrical tree endurance in BN/Epoxy relative to the clean epoxy can be attributed to increased mechanical stiffness. The superiority of the CNS/Epoxy as a nanodielectric is notable. The effect is suggested to be due to the electron affinity properties of the carbon nanospheres at appropriate dispersion levels.
- 20 May 2020
- Published by Trans Tech Publications, Ltd. in International Journal of Engineering Research in Africa
- Vol. 48, 24-37
Comparative Characterisation of CNS/Epoxy and BN/Epoxy Nanodielectrics Using Electrical Tree PD Measurements and Atomic Force Microscopy
This paper contributes to the body of knowledge on the efforts to develop nanodielectrics as the next generation of insulation material. The time-to-failure under electrical tree-induced degradation of 1.09-1.35 vol.% hexagonal BN/Epoxy was found to be 3 times longer than in clean epoxy. For 0.31-0.33 vol.% CNS/Epoxy the time-to-failure was 24 times longer than the clean epoxy. The electrical treeing partial discharge behaviour in the BN/Epoxy and CNS/Epoxy showed distinct time-evolution characteristics different from those in the clean epoxy. The improved electrical tree endurance in BN/Epoxy relative to the clean epoxy can be attributed to increased mechanical stiffness. The superiority of the CNS/Epoxy as a nanodielectric is notable. The effect is suggested to be due to the electron affinity properties of the carbon nanospheres at appropriate dispersion levels.