Shijun Sung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shijun Sung has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Dan-Fong Li
Department of Orthopaedic Surgery, Naval Medical Center Portsmouth, Portsmouth, Virginia
2 shared publications - Jacob Goell
Department of Bioengineering, Rice University
2 shared publications - James Garritano
Center for Advanced Surgical and Interventional Technology (CASIT), University of California (UCLA), Los Angeles, CA, USA
2 shared publications - Neha Bajwa
Univ. of California, Los Angeles (United States)
2 shared publications Skyler Selvin
Department of Electrical Engineering, University of California at Los Angeles, Los Angeles, CA, USA
2 shared publications- Somporn Chantra
Department of Ophthalmology, Rajavithi Hospital, 2, Phayathai Road, Ratchathewi District, Bangkok 10400, Thailand
2 shared publications
Latest Publications
- 1 January 2022
- Published by Springer Nature
- p. 145-152
Development of Emergency Resuscitators: Considerations for Mechanical and Electrical Components
- 1 January 2022
- Published by Springer Nature
- p. 145-152
Development of Emergency Resuscitators: Considerations for Mechanical and Electrical Components
- 7 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 8 (1) , 27-37
THz Imaging System for in vivo Human Cornea
Terahertz (THz) imaging of corneal tissue water content (CTWC) is a proposed method for early, accurate detection and study of corneal diseases. Despite promising results from ex vivo and in vivo cornea studies, interpretation of the reflectivity data is confounded by the contact between corneal tissue and rigid dielectric window used to flatten the imaging field. This work develops a novel imaging system and image reconstruction methods specifically for nearly spherical targets such as human cornea. A prototype system was constructed using a 650-GHz multiplier source and Schottky diode detector. Resolution and imaging field strength measurement from characterization targets correlate well with those predicted by the quasioptical theory and physical optics analysis. Imaging experiments with corneal phantoms and ex vivo corneas demonstrate the hydration sensitivity of the imaging system and reliable measurement of CTWC. We present successful acquisition of noncontact THz images of in vivo human cornea, and discuss strategies for optimizing the imaging system design for clinical use.
- 7 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 8 (1) , 27-37
THz Imaging System for in vivo Human Cornea
Terahertz (THz) imaging of corneal tissue water content (CTWC) is a proposed method for early, accurate detection and study of corneal diseases. Despite promising results from ex vivo and in vivo cornea studies, interpretation of the reflectivity data is confounded by the contact between corneal tissue and rigid dielectric window used to flatten the imaging field. This work develops a novel imaging system and image reconstruction methods specifically for nearly spherical targets such as human cornea. A prototype system was constructed using a 650-GHz multiplier source and Schottky diode detector. Resolution and imaging field strength measurement from characterization targets correlate well with those predicted by the quasioptical theory and physical optics analysis. Imaging experiments with corneal phantoms and ex vivo corneas demonstrate the hydration sensitivity of the imaging system and reliable measurement of CTWC. We present successful acquisition of noncontact THz images of in vivo human cornea, and discuss strategies for optimizing the imaging system design for clinical use.
- 22 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 8 (1) , 1-12
Optical System Design for Noncontact, Normal Incidence, THz Imaging of in vivo Human Cornea
Reflection-mode terahertz (THz) imaging of corneal tissue water content (CTWC) is a proposed method for early accurate detection and study of corneal diseases. Despite promising results from ex vivo and in vivo cornea studies, interpretation of the reflectivity data is confounded by the contact between corneal tissue and dielectric windows used to flatten the imaging field. Herein, we present an optical design for noncontact THz imaging of cornea. A beam-scanning methodology performs angular normal incidence sweeps of a focused beam over the corneal surface while keeping the source, detector, and patient stationary. A quasi-optical analysis method is developed to analyze the theoretical resolution and imaging field intensity profile. These results are compared to the electric field distribution computed with a physical optics analysis code. Imaging experiments validate the optical theories behind the design and suggest that quasi-optical methods are sufficient for designing of THz corneal imaging systems. Successful imaging operations support the feasibility of noncontact in vivo imaging. We believe that this optical system design will enable the first, clinically relevant, in vivo exploration of CTWC using THz technology.
- 22 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 8 (1) , 1-12
Optical System Design for Noncontact, Normal Incidence, THz Imaging of in vivo Human Cornea
Reflection-mode terahertz (THz) imaging of corneal tissue water content (CTWC) is a proposed method for early accurate detection and study of corneal diseases. Despite promising results from ex vivo and in vivo cornea studies, interpretation of the reflectivity data is confounded by the contact between corneal tissue and dielectric windows used to flatten the imaging field. Herein, we present an optical design for noncontact THz imaging of cornea. A beam-scanning methodology performs angular normal incidence sweeps of a focused beam over the corneal surface while keeping the source, detector, and patient stationary. A quasi-optical analysis method is developed to analyze the theoretical resolution and imaging field intensity profile. These results are compared to the electric field distribution computed with a physical optics analysis code. Imaging experiments validate the optical theories behind the design and suggest that quasi-optical methods are sufficient for designing of THz corneal imaging systems. Successful imaging operations support the feasibility of noncontact in vivo imaging. We believe that this optical system design will enable the first, clinically relevant, in vivo exploration of CTWC using THz technology.