Neha Bajwa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Neha Bajwa has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Shijun Sung
University of California, Los Angeles, Los Angeles, CA, 90095 USA
5 shared publications- Zachary D. Taylor
Aalto University
5 shared publications Warren S. Grundfest
Department of Electrical Engineering and the Department of Bioengineering, University of California at Los Angeles, Los Angeles, CA, USA
3 shared publications- Warren S. Grundfest
Biomedical Engineering IDP, UCLA, Los Angeles, California United States 90095-1600
3 shared publications - Alexander Dan-Fong Li
Department of Orthopaedic Surgery, Naval Medical Center Portsmouth, Portsmouth, Virginia
2 shared publications Daniel B. Ennis
Department of Radiological Sciences, University of California, Los Angeles
2 shared publications
Latest Publications
- Open Access
- 19 January 2026
- Published by Uniwersytet Mikolaja Kopernika/Nicolaus Copernicus University in Ecological Questions
- Vol. 37 (1) , 1-22
Impact assessment of land surface temperature on air pollution and smog formation in major cities of Pakistan using Google Earth engine
Rapid urbanization, industrial expansion, and reliance on fossil fuels cause serious air pollution. Air pollution affects public health, especially in developing countries like Pakistan. Pakistan is among the most affected nations, particularly its major urban centers, which experience recurrent seasonal smog episodes. This study assesses the effectiveness of Sentinel-5P satellite products integrated with Google Earth Engine (GEE) for monitoring spatiotemporal variations of key air pollutants: nitrogen dioxide (NO₂), carbon monoxide (CO), and ozone (O₃) in Lahore, Faisalabad, Multan, and Gujranwala from 2018 to 2023. Monthly, seasonal, and annual composites of cloud-filtered Sentinel-5P TROPOMI data were analyzed using GEE, and statistical regression and correlation analyses were applied to examine relationships between pollutant concentrations and land surface temperature (LST). The results reveal pronounced seasonal variability in air pollutant levels, with elevated NO₂ and CO concentrations during winter due to intensified anthropogenic emissions and atmospheric stability, while O₃ concentrations peaked during spring and summer due to enhanced photochemical reactions driven by high temperatures and solar radiation. Quantitatively, wintertime NO₂ concentrations reached approximately 0.009 mol m⁻², whereas summer O₃ concentrations peaked at about 0.30 mol m⁻². Strong temperature–pollutant relationships were observed in highly urbanized cities such as Lahore and Faisalabad, reflecting the combined effects of dense infrastructure, industrial activity, and urban heat island intensity. Additionally, the COVID-19 lockdown period provided evidence of temporary reductions in pollutant concentrations and LST, highlighting the dominant role of anthropogenic activities in air quality degradation. Overall, the findings demonstrate that Sentinel-5P data, combined with automated cloud-based platforms such as GEE, provides a robust, cost-effective framework for large-scale air quality monitoring. This approach can support informed policymaking, targeted mitigation strategies, and sustainable urban planning to reduce smog intensity and protect public health in Pakistan.
- 19 January 2026
- Published by Uniwersytet Mikolaja Kopernika/Nicolaus Copernicus University in Ecological Questions
- Vol. 37 (1) , 1-22
Open AccessImpact assessment of land surface temperature on air pollution and smog formation in major cities of Pakistan using Google Earth engine
Rapid urbanization, industrial expansion, and reliance on fossil fuels cause serious air pollution. Air pollution affects public health, especially in developing countries like Pakistan. Pakistan is among the most affected nations, particularly its major urban centers, which experience recurrent seasonal smog episodes. This study assesses the effectiveness of Sentinel-5P satellite products integrated with Google Earth Engine (GEE) for monitoring spatiotemporal variations of key air pollutants: nitrogen dioxide (NO₂), carbon monoxide (CO), and ozone (O₃) in Lahore, Faisalabad, Multan, and Gujranwala from 2018 to 2023. Monthly, seasonal, and annual composites of cloud-filtered Sentinel-5P TROPOMI data were analyzed using GEE, and statistical regression and correlation analyses were applied to examine relationships between pollutant concentrations and land surface temperature (LST). The results reveal pronounced seasonal variability in air pollutant levels, with elevated NO₂ and CO concentrations during winter due to intensified anthropogenic emissions and atmospheric stability, while O₃ concentrations peaked during spring and summer due to enhanced photochemical reactions driven by high temperatures and solar radiation. Quantitatively, wintertime NO₂ concentrations reached approximately 0.009 mol m⁻², whereas summer O₃ concentrations peaked at about 0.30 mol m⁻². Strong temperature–pollutant relationships were observed in highly urbanized cities such as Lahore and Faisalabad, reflecting the combined effects of dense infrastructure, industrial activity, and urban heat island intensity. Additionally, the COVID-19 lockdown period provided evidence of temporary reductions in pollutant concentrations and LST, highlighting the dominant role of anthropogenic activities in air quality degradation. Overall, the findings demonstrate that Sentinel-5P data, combined with automated cloud-based platforms such as GEE, provides a robust, cost-effective framework for large-scale air quality monitoring. This approach can support informed policymaking, targeted mitigation strategies, and sustainable urban planning to reduce smog intensity and protect public health in Pakistan.
- 7 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 8 (1) , 27-37
THz Imaging System for in vivo Human Cornea
Terahertz (THz) imaging of corneal tissue water content (CTWC) is a proposed method for early, accurate detection and study of corneal diseases. Despite promising results from ex vivo and in vivo cornea studies, interpretation of the reflectivity data is confounded by the contact between corneal tissue and rigid dielectric window used to flatten the imaging field. This work develops a novel imaging system and image reconstruction methods specifically for nearly spherical targets such as human cornea. A prototype system was constructed using a 650-GHz multiplier source and Schottky diode detector. Resolution and imaging field strength measurement from characterization targets correlate well with those predicted by the quasioptical theory and physical optics analysis. Imaging experiments with corneal phantoms and ex vivo corneas demonstrate the hydration sensitivity of the imaging system and reliable measurement of CTWC. We present successful acquisition of noncontact THz images of in vivo human cornea, and discuss strategies for optimizing the imaging system design for clinical use.
- 7 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 8 (1) , 27-37
THz Imaging System for in vivo Human Cornea
Terahertz (THz) imaging of corneal tissue water content (CTWC) is a proposed method for early, accurate detection and study of corneal diseases. Despite promising results from ex vivo and in vivo cornea studies, interpretation of the reflectivity data is confounded by the contact between corneal tissue and rigid dielectric window used to flatten the imaging field. This work develops a novel imaging system and image reconstruction methods specifically for nearly spherical targets such as human cornea. A prototype system was constructed using a 650-GHz multiplier source and Schottky diode detector. Resolution and imaging field strength measurement from characterization targets correlate well with those predicted by the quasioptical theory and physical optics analysis. Imaging experiments with corneal phantoms and ex vivo corneas demonstrate the hydration sensitivity of the imaging system and reliable measurement of CTWC. We present successful acquisition of noncontact THz images of in vivo human cornea, and discuss strategies for optimizing the imaging system design for clinical use.
- 22 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 8 (1) , 1-12
Optical System Design for Noncontact, Normal Incidence, THz Imaging of in vivo Human Cornea
Reflection-mode terahertz (THz) imaging of corneal tissue water content (CTWC) is a proposed method for early accurate detection and study of corneal diseases. Despite promising results from ex vivo and in vivo cornea studies, interpretation of the reflectivity data is confounded by the contact between corneal tissue and dielectric windows used to flatten the imaging field. Herein, we present an optical design for noncontact THz imaging of cornea. A beam-scanning methodology performs angular normal incidence sweeps of a focused beam over the corneal surface while keeping the source, detector, and patient stationary. A quasi-optical analysis method is developed to analyze the theoretical resolution and imaging field intensity profile. These results are compared to the electric field distribution computed with a physical optics analysis code. Imaging experiments validate the optical theories behind the design and suggest that quasi-optical methods are sufficient for designing of THz corneal imaging systems. Successful imaging operations support the feasibility of noncontact in vivo imaging. We believe that this optical system design will enable the first, clinically relevant, in vivo exploration of CTWC using THz technology.
- 22 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 8 (1) , 1-12
Optical System Design for Noncontact, Normal Incidence, THz Imaging of in vivo Human Cornea
Reflection-mode terahertz (THz) imaging of corneal tissue water content (CTWC) is a proposed method for early accurate detection and study of corneal diseases. Despite promising results from ex vivo and in vivo cornea studies, interpretation of the reflectivity data is confounded by the contact between corneal tissue and dielectric windows used to flatten the imaging field. Herein, we present an optical design for noncontact THz imaging of cornea. A beam-scanning methodology performs angular normal incidence sweeps of a focused beam over the corneal surface while keeping the source, detector, and patient stationary. A quasi-optical analysis method is developed to analyze the theoretical resolution and imaging field intensity profile. These results are compared to the electric field distribution computed with a physical optics analysis code. Imaging experiments validate the optical theories behind the design and suggest that quasi-optical methods are sufficient for designing of THz corneal imaging systems. Successful imaging operations support the feasibility of noncontact in vivo imaging. We believe that this optical system design will enable the first, clinically relevant, in vivo exploration of CTWC using THz technology.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
THz imaging as an adjunct for T2 weighted magnetic resonance imaging
In vivo visualization and quantification of surface tissue edema, or `tissue swelling' following injury or as diagnostic criteria for the detection of disease remains a clinical challenge. The most common method for evaluating edema is by clinical examination, during which tissue swelling and turgor are routinely examined. This technique, however, is qualitative, difficult to standardize, and requires considerable clinical expertise. T2 - weighted (T2w) magnetic resonance imaging (MRI) has been used to visualize the hydration state of skin in vivo and provides comprehensive, layer-specific anatomical and physiological data. While clinical utility has been demonstrated in a range of applications, adoption has been limited due to instrument size, cost, and the technical challenges associated with surface tissue data interpretation. These factors provide a potential opportunity for THz medical imaging. In this talk we propose THz maps of tissue water content (TWC) as an adjunct to MRI. For applications where (1) surface tissue water content is correlated with disease/injury state and (2) technical challenges and/or adoption costs restrict the use of MRI, THz imaging can be leveraged to fill the diagnostic gap. Candidate applications are discussed including burn wound severity assessment, surgical flap viability prediction, and allergy testing.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
THz imaging as an adjunct for T2 weighted magnetic resonance imaging
In vivo visualization and quantification of surface tissue edema, or `tissue swelling' following injury or as diagnostic criteria for the detection of disease remains a clinical challenge. The most common method for evaluating edema is by clinical examination, during which tissue swelling and turgor are routinely examined. This technique, however, is qualitative, difficult to standardize, and requires considerable clinical expertise. T2 - weighted (T2w) magnetic resonance imaging (MRI) has been used to visualize the hydration state of skin in vivo and provides comprehensive, layer-specific anatomical and physiological data. While clinical utility has been demonstrated in a range of applications, adoption has been limited due to instrument size, cost, and the technical challenges associated with surface tissue data interpretation. These factors provide a potential opportunity for THz medical imaging. In this talk we propose THz maps of tissue water content (TWC) as an adjunct to MRI. For applications where (1) surface tissue water content is correlated with disease/injury state and (2) technical challenges and/or adoption costs restrict the use of MRI, THz imaging can be leveraged to fill the diagnostic gap. Candidate applications are discussed including burn wound severity assessment, surgical flap viability prediction, and allergy testing.
- 26 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 64 (11) , 2682-2694
Terahertz Imaging of Cutaneous Edema: Correlation With Magnetic Resonance Imaging in Burn Wounds
Objective: In vivo visualization and quantification of edema, or `tissue swelling' following injury, remains a clinical challenge. Herein, we investigate the ability of reflective terahertz (THz) imaging to track changes in tissue water content (TWC)-the direct indicator of edema-by comparison to depth-resolved magnetic resonance imaging (MRI) in a burn-induced model of edema. Methods: A partial thickness and full thickness burns were induced in an in vivo rat model to elicit unique TWC perturbations corresponding to burn severity. Concomitant THz surface maps and MRI images of both burn models were acquired with a previously reported THz imaging system and T2-weighted MRI, respectively, over 270 min. Reflectivity was analyzed for the burn contact area in THz images, while proton density (i.e., mobile TWC) was analyzed for the same region at incrementally increasing tissue depths in companion, transverse MRI images. A normalized cross correlation of THz and depth-dependent MRI measurements was performed as a function of time in histologically verified burn wounds. Results: For both burn types, strong positive correlations were evident between THz reflectivity and MRI data analyzed at greater tissue depths (>258 μm). MRI and THz results also revealed biphasic trends consistent with burn edema pathogenesis. Conclusion: This paper offers the first in vivo correlative assessment of mobile TWC-based contrast and the sensing depth of THz imaging. Significance: The ability to implement THz imaging immediately following injury, combined with TWC sensing capabilities that compare to MRI, further support THz sensing as an emerging tool to track fluid in tissue.
- 26 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 64 (11) , 2682-2694
Terahertz Imaging of Cutaneous Edema: Correlation With Magnetic Resonance Imaging in Burn Wounds
Objective: In vivo visualization and quantification of edema, or `tissue swelling' following injury, remains a clinical challenge. Herein, we investigate the ability of reflective terahertz (THz) imaging to track changes in tissue water content (TWC)-the direct indicator of edema-by comparison to depth-resolved magnetic resonance imaging (MRI) in a burn-induced model of edema. Methods: A partial thickness and full thickness burns were induced in an in vivo rat model to elicit unique TWC perturbations corresponding to burn severity. Concomitant THz surface maps and MRI images of both burn models were acquired with a previously reported THz imaging system and T2-weighted MRI, respectively, over 270 min. Reflectivity was analyzed for the burn contact area in THz images, while proton density (i.e., mobile TWC) was analyzed for the same region at incrementally increasing tissue depths in companion, transverse MRI images. A normalized cross correlation of THz and depth-dependent MRI measurements was performed as a function of time in histologically verified burn wounds. Results: For both burn types, strong positive correlations were evident between THz reflectivity and MRI data analyzed at greater tissue depths (>258 μm). MRI and THz results also revealed biphasic trends consistent with burn edema pathogenesis. Conclusion: This paper offers the first in vivo correlative assessment of mobile TWC-based contrast and the sensing depth of THz imaging. Significance: The ability to implement THz imaging immediately following injury, combined with TWC sensing capabilities that compare to MRI, further support THz sensing as an emerging tool to track fluid in tissue.
- Open Access
- 23 December 2016
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 8 (1) , 460-474
Non-invasive terahertz imaging of tissue water content for flap viability assessment
Accurate and early prediction of tissue viability is the most significant determinant of tissue flap survival in reconstructive surgery. Perturbation in tissue water content (TWC) is a generic component of the tissue response to such surgeries, and, therefore, may be an important diagnostic target for assessing the extent of flap viability in vivo. We have previously shown that reflective terahertz (THz) imaging, a non-ionizing technique, can generate spatially resolved maps of TWC in superficial soft tissues, such as cornea and wounds, on the order of minutes. Herein, we report the first in vivo pilot study to investigate the utility of reflective THz TWC imaging for early assessment of skin flap viability. We obtained longitudinal visible and reflective THz imagery comparing 3 bipedicled flaps (i.e. survival model) and 3 fully excised flaps (i.e. failure model) in the dorsal skin of rats over a postoperative period of 7 days. While visual differences between both models manifested 48 hr after surgery, statistically significant (p < 0.05, independent t-test) local differences in TWC contrast were evident in THz flap image sets as early as 24 hr. Excised flaps, histologically confirmed as necrotic, demonstrated a significant, yet localized, reduction in TWC in the flap region compared to non-traumatized skin. In contrast, bipedicled flaps, histologically verified as viable, displayed mostly uniform, unperturbed TWC across the flap tissue. These results indicate the practical potential of THz TWC sensing to accurately predict flap failure 24 hours earlier than clinical examination.
- 23 December 2016
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 8 (1) , 460-474
Open AccessNon-invasive terahertz imaging of tissue water content for flap viability assessment
Accurate and early prediction of tissue viability is the most significant determinant of tissue flap survival in reconstructive surgery. Perturbation in tissue water content (TWC) is a generic component of the tissue response to such surgeries, and, therefore, may be an important diagnostic target for assessing the extent of flap viability in vivo. We have previously shown that reflective terahertz (THz) imaging, a non-ionizing technique, can generate spatially resolved maps of TWC in superficial soft tissues, such as cornea and wounds, on the order of minutes. Herein, we report the first in vivo pilot study to investigate the utility of reflective THz TWC imaging for early assessment of skin flap viability. We obtained longitudinal visible and reflective THz imagery comparing 3 bipedicled flaps (i.e. survival model) and 3 fully excised flaps (i.e. failure model) in the dorsal skin of rats over a postoperative period of 7 days. While visual differences between both models manifested 48 hr after surgery, statistically significant (p < 0.05, independent t-test) local differences in TWC contrast were evident in THz flap image sets as early as 24 hr. Excised flaps, histologically confirmed as necrotic, demonstrated a significant, yet localized, reduction in TWC in the flap region compared to non-traumatized skin. In contrast, bipedicled flaps, histologically verified as viable, displayed mostly uniform, unperturbed TWC across the flap tissue. These results indicate the practical potential of THz TWC sensing to accurately predict flap failure 24 hours earlier than clinical examination.
- 31 August 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9585, 95850T
Exploration of the effects of burn parameters on THz wound imaging
The high contrast resolution afforded by terahertz (1 THz = 1012 Hz) imaging of physiologic tissue continues to drive explorations into the utility of THz technology for burn wound detection. Although we have previously reported the use of a novel, reflective THz imaging technology to sense spatiotemporal differences in reflectivity between partial and full thickness burn wounds, no evidence exists of a one-to-one correlation between structural damage observed in histological assessments of burn severity and THz signal. For example, varying burn induction methods may all result in a common burn wound severity, however, burn features observed in parallel THz imagery may not be identical. Successful clinical translation of THz technology as a comprehensive burn guidance tool, therefore, necessitates an understanding of THz signal and its relation to wound pathophysiology. In this work, longitudinal THz imagery was acquired with a quartz (n = 2.1, 500 μm) window of cutaneous wounds induced with the same brand geometry and contact pressure but varying contact times (5, 7, and 10 seconds) in in vivo, pre-clinical rat models (n=3) over a period of 3 days. Though all burn wounds were evaluated to be deep partial thickness with histology, THz contrasts observed for each burn contact time were intrinsically unique. This is the first preliminary in vivo evidence of a many-to-one relationship between changes in THz contrast and burn severity as ascertained by histology. Future large-scale studies are required to assess whether these observed changes in THz contrast may be interpreted as physiological changes occurring over time, morphometric changes related to anatomical change, or electromagnetic changes between dielectric substrate windows and the underlying tissue.
- 31 August 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9585, 95850T
Exploration of the effects of burn parameters on THz wound imaging
The high contrast resolution afforded by terahertz (1 THz = 1012 Hz) imaging of physiologic tissue continues to drive explorations into the utility of THz technology for burn wound detection. Although we have previously reported the use of a novel, reflective THz imaging technology to sense spatiotemporal differences in reflectivity between partial and full thickness burn wounds, no evidence exists of a one-to-one correlation between structural damage observed in histological assessments of burn severity and THz signal. For example, varying burn induction methods may all result in a common burn wound severity, however, burn features observed in parallel THz imagery may not be identical. Successful clinical translation of THz technology as a comprehensive burn guidance tool, therefore, necessitates an understanding of THz signal and its relation to wound pathophysiology. In this work, longitudinal THz imagery was acquired with a quartz (n = 2.1, 500 μm) window of cutaneous wounds induced with the same brand geometry and contact pressure but varying contact times (5, 7, and 10 seconds) in in vivo, pre-clinical rat models (n=3) over a period of 3 days. Though all burn wounds were evaluated to be deep partial thickness with histology, THz contrasts observed for each burn contact time were intrinsically unique. This is the first preliminary in vivo evidence of a many-to-one relationship between changes in THz contrast and burn severity as ascertained by histology. Future large-scale studies are required to assess whether these observed changes in THz contrast may be interpreted as physiological changes occurring over time, morphometric changes related to anatomical change, or electromagnetic changes between dielectric substrate windows and the underlying tissue.
- 22 February 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8585, 85850X
Reflectivity measurements of water and dioxane mixtures using a 100 GHz Gunn diode source
Terahertz (THz) sensing has shown potential as a novel imaging modality in medical applications due to its high water sensitivity. The design of medical THz sensing systems and their successful application to in vivo settings has attracted recent interest to the field, and highlighted the need for improved understanding of the interaction of THz waves with biological tissues. This paper explores the modeling of composite materials which combine strongly-interacting water with weakly-interacting species such as those that are common to biological tissues. The Bruggeman, Maxwell-Garnett, and power law effective media models are introduced and discussed. A reflection-mode 100 GHz Gunn diode sensing system was used to measure the reflectivity of solutions of water and dioxane as a function of relative concentration, and the results were compared with the predictions of the Maxwell-Garnett, power law, and Bruggeman mixing theories. The Maxwell-Garnett model fit poorly to experimental data on near-equal mixtures of water and dioxane and improved when the concentration of water exceeded ~55% or was below ~15%. The first-order power law model fit poorly to experimental data across the entire range except at nearpure solutions. Power law models employing 1/2 and 1/3 terms improved goodness of fit, but did not match the accuracy of the Bruggeman model. The Bruggeman provided the best fit to experimental data model as compared to Maxwell-Garnett and the power models and accurately predicted the solution reflectivity through the whole range of concentrations. This analysis suggests that the Bruggeman model may offer improved accuracy over more conventional dielectric mixing models when developing simulation tools for THz reflectometry of hydrated biological tissues.
- 22 February 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8585, 85850X
Reflectivity measurements of water and dioxane mixtures using a 100 GHz Gunn diode source
Terahertz (THz) sensing has shown potential as a novel imaging modality in medical applications due to its high water sensitivity. The design of medical THz sensing systems and their successful application to in vivo settings has attracted recent interest to the field, and highlighted the need for improved understanding of the interaction of THz waves with biological tissues. This paper explores the modeling of composite materials which combine strongly-interacting water with weakly-interacting species such as those that are common to biological tissues. The Bruggeman, Maxwell-Garnett, and power law effective media models are introduced and discussed. A reflection-mode 100 GHz Gunn diode sensing system was used to measure the reflectivity of solutions of water and dioxane as a function of relative concentration, and the results were compared with the predictions of the Maxwell-Garnett, power law, and Bruggeman mixing theories. The Maxwell-Garnett model fit poorly to experimental data on near-equal mixtures of water and dioxane and improved when the concentration of water exceeded ~55% or was below ~15%. The first-order power law model fit poorly to experimental data across the entire range except at nearpure solutions. Power law models employing 1/2 and 1/3 terms improved goodness of fit, but did not match the accuracy of the Bruggeman model. The Bruggeman provided the best fit to experimental data model as compared to Maxwell-Garnett and the power models and accurately predicted the solution reflectivity through the whole range of concentrations. This analysis suggests that the Bruggeman model may offer improved accuracy over more conventional dielectric mixing models when developing simulation tools for THz reflectometry of hydrated biological tissues.