Gufran Ahmad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Gufran Ahmad has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Sandipan Mallik
Department of Electronics and Communication Engineering, NIST University, Berhampur, Odisha 761008, India
7 shared publications - Cheng-Yao Lo
Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, Taiwan
3 shared publications - Shrabani Guhathakurata
Department of ECE, NIST (Autonomous), Berhampur, India
3 shared publications - Asok Kumar Barua
Indian Institute of Engineering Science and Technology, Shibpur
2 shared publications - Jatindra Nath Roy
School of Energy Science and Engineering, Indian Institute of Technology Kharagpur, Kharagpur, India
2 shared publications Khushboo Dixit
Department of Electrical Engineering Dayalbagh Educational Institute (Deemed University) Agra
2 shared publications
Latest Publications
- 26 April 2025
- Published by Springer Nature in Circuits, Systems, and Signal Processing
- Vol. 44 (9) , 6255-6275
Fault Diagnosis in Analog Circuits Using Stacking Ensemble Machine Learning Approach
- 26 April 2025
- Published by Springer Nature in Circuits, Systems, and Signal Processing
- Vol. 44 (9) , 6255-6275
Fault Diagnosis in Analog Circuits Using Stacking Ensemble Machine Learning Approach
- 2 July 2024
- Published by Springer Nature in Indian Journal of Physics
- Vol. 99 (2) , 479-488
Design prospect of CdTe solar cell using NW-CdS window layer and 3D graphene as back electrode from numerical approach
- 2 July 2024
- Published by Springer Nature in Indian Journal of Physics
- Vol. 99 (2) , 479-488
Design prospect of CdTe solar cell using NW-CdS window layer and 3D graphene as back electrode from numerical approach
- 5 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (7) , 9506-9513
Thermoresistive Profile Sensing Based on Isotropic Strain Detection With Taiji Pattern Routing
This research proposed a novel Taiji pattern enclosed in a thermoresistor routing, which took advantage of Joule heating to visualize strain type, extent, orientation, and distribution, through thermal images. By applying an appropriate power (voltage or current), the sensor was also capable of decoupling the serial connection of tension and compression with a preliminarily built relationship between temperature and strain. The Taiji pattern avoided conventional limitation on the orientation of strain gauges, providing isotropic detection freedom; and tunable sensitivity was achieved by modulating the detection duration, which provided operation flexibility for the first time. Simulations were also conducted to evaluate the performances before experimental evidences (spatial and strain resolution of 125 μm and 0.00417%, respectively) were demonstrated in this work. Three-dimensional printed workpieces with various tensile and compressive shapes were utilized to emulate the real-time strains. The results validated the effectiveness and versatility of the proposed sensor and sensing system, and exhibited comprehensive insights into potential applications.
- 5 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (7) , 9506-9513
Thermoresistive Profile Sensing Based on Isotropic Strain Detection With Taiji Pattern Routing
This research proposed a novel Taiji pattern enclosed in a thermoresistor routing, which took advantage of Joule heating to visualize strain type, extent, orientation, and distribution, through thermal images. By applying an appropriate power (voltage or current), the sensor was also capable of decoupling the serial connection of tension and compression with a preliminarily built relationship between temperature and strain. The Taiji pattern avoided conventional limitation on the orientation of strain gauges, providing isotropic detection freedom; and tunable sensitivity was achieved by modulating the detection duration, which provided operation flexibility for the first time. Simulations were also conducted to evaluate the performances before experimental evidences (spatial and strain resolution of 125 μm and 0.00417%, respectively) were demonstrated in this work. Three-dimensional printed workpieces with various tensile and compressive shapes were utilized to emulate the real-time strains. The results validated the effectiveness and versatility of the proposed sensor and sensing system, and exhibited comprehensive insights into potential applications.
- Open Access
- 1 January 2024
- Published by CSIR-National Institute of Science Communication and Policy Research (NIScPR) in Indian Journal of Pure & Applied Physics
- Vol. 62 (11) , 971-978
A Simulation Study of Various ETL Layers to Design the High Performance Pb-Free perovskite (FASnI3) Solar Cell
There are significant efforts being made to develop high-efficiency, lead-free perovskite solar cells (PSCs). In this study, Formamidinium tin iodide (FASnI3) has been used as an absorber layer to design a stable lead-free PSC. FASnI3 absorber has a wider band gap (1.41 eV) and is more temperature stable than lead-free Sn-based perovskite (CH3NH3SnI3). In this work, 1-D device simulation has been performed using SCAPS to get the optimum performance of the lead-free FASnI3-based PSCs. We have checked varieties of electron transport layers (ETL) such as WO3, TiO2, ZnO, PCBM, IGZO, ZnS, and WS2 to find the maximum power conversion efficiency (PCE) from the FASnI3 lead-free PSC. A detailed simulation study of the proposed solar cell architecture using SCAPS has been done to optimize the device structure and get the maximum power conversion efficiency. The proposed solar cell structure has shown an efficiency of 16% with a JSC of 27.02 mA, Voc of 0.925V, and FF of 63.98% which is the highest among the FASnI3 based lead-free solar cell structures to date.
- 1 January 2024
- Published by CSIR-National Institute of Science Communication and Policy Research (NIScPR) in Indian Journal of Pure & Applied Physics
- Vol. 62 (11) , 971-978
Open AccessA Simulation Study of Various ETL Layers to Design the High Performance Pb-Free perovskite (FASnI3) Solar Cell
There are significant efforts being made to develop high-efficiency, lead-free perovskite solar cells (PSCs). In this study, Formamidinium tin iodide (FASnI3) has been used as an absorber layer to design a stable lead-free PSC. FASnI3 absorber has a wider band gap (1.41 eV) and is more temperature stable than lead-free Sn-based perovskite (CH3NH3SnI3). In this work, 1-D device simulation has been performed using SCAPS to get the optimum performance of the lead-free FASnI3-based PSCs. We have checked varieties of electron transport layers (ETL) such as WO3, TiO2, ZnO, PCBM, IGZO, ZnS, and WS2 to find the maximum power conversion efficiency (PCE) from the FASnI3 lead-free PSC. A detailed simulation study of the proposed solar cell architecture using SCAPS has been done to optimize the device structure and get the maximum power conversion efficiency. The proposed solar cell structure has shown an efficiency of 16% with a JSC of 27.02 mA, Voc of 0.925V, and FF of 63.98% which is the highest among the FASnI3 based lead-free solar cell structures to date.
- Open Access
- 1 January 2024
- Published by CSIR-National Institute of Science Communication and Policy Research (NIScPR) in Indian Journal of Pure & Applied Physics
- Vol. 62 (7) , 553-561
Study of High Efficiency Lead Free FASnI3 Perovskite Solar Cell with WO3ETL and Cu2O HTL Using Numerical Analysis
Tin based perovskite solar cell have gained the significant attention in recent year due to its potential to revolutionize the field of photovoltaic. The substitution of lead with tin in perovskite solar cells helps address the toxicity issues associated with lead based material. Formamidinium tin triiodide (FASnI3) had a more solid perovskite structure, wider bandgap of 1.41 eV and is more temperature stable than methylammonium tin triiodide (MASnI3). These are the reasons we chose FASnI3 in this study. In this work we simulated FASnI3 based perovskite solar cell using tungsten trioxide (WO3) as an electron transport material and cuprous oxide (Cu2O) as an hole transport material using SCAPS simulation.We investigated the impact of varying the thickness and doping concentration of different layer of PSC. Additionally, the effect of interface defect density and temperature dependence on device performance are examined. Further, various metal back contacts such as Au, Ag, Cu, Pt and Ni are investigated to enhance the power conversion efficiency (PCE) of final structure. The initial design was founded on an reported simulation that achieved the PCE of 14.03 %.The proposed solar cell structure has shown an efficiency of 23.44 % with a Jsc of 22.83 (mA/cm2), a Voc of 1.18 V, and a FF of 86.95 %. It is the highest reported efficiency of FASnI3 based perovskite solar cell using WO3 as an ETL till date.
- 1 January 2024
- Published by CSIR-National Institute of Science Communication and Policy Research (NIScPR) in Indian Journal of Pure & Applied Physics
- Vol. 62 (7) , 553-561
Open AccessStudy of High Efficiency Lead Free FASnI3 Perovskite Solar Cell with WO3ETL and Cu2O HTL Using Numerical Analysis
Tin based perovskite solar cell have gained the significant attention in recent year due to its potential to revolutionize the field of photovoltaic. The substitution of lead with tin in perovskite solar cells helps address the toxicity issues associated with lead based material. Formamidinium tin triiodide (FASnI3) had a more solid perovskite structure, wider bandgap of 1.41 eV and is more temperature stable than methylammonium tin triiodide (MASnI3). These are the reasons we chose FASnI3 in this study. In this work we simulated FASnI3 based perovskite solar cell using tungsten trioxide (WO3) as an electron transport material and cuprous oxide (Cu2O) as an hole transport material using SCAPS simulation.We investigated the impact of varying the thickness and doping concentration of different layer of PSC. Additionally, the effect of interface defect density and temperature dependence on device performance are examined. Further, various metal back contacts such as Au, Ag, Cu, Pt and Ni are investigated to enhance the power conversion efficiency (PCE) of final structure. The initial design was founded on an reported simulation that achieved the PCE of 14.03 %.The proposed solar cell structure has shown an efficiency of 23.44 % with a Jsc of 22.83 (mA/cm2), a Voc of 1.18 V, and a FF of 86.95 %. It is the highest reported efficiency of FASnI3 based perovskite solar cell using WO3 as an ETL till date.
- 23 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (24) , 30135-30142
Novel Multiaxial Force Decoupling Strategy in Vertically Stacked Force Sensors With Hybrid Fabrication Techniques
This study shows the development of a capacitive force sensor, which can not only detect multi-axial forces but also differentiate the applied normal and shear force due to its innovative structural design. The sensor contains five capacitors arranged in a specific pattern as a sensing unit with vertically stacked three polyethylene terephthalate substrates, two polydimethylsiloxane dielectrics, and several silver electrodes in each capacitor. In addition, one and four capacitors were put to the upper (hard) and lower (soft) layer, respectively. Comprehensive structure design, numerical simulation, hybrid fabrication (photolithography and inkjet printing), and analysis were performed in this work. Under the normal force, the top capacitor showed a sensitivity of 0.501 pF/N, while the bottom capacitors showed a comparably negligible sensitivity of 5.267 fF/N. Meanwhile, under the shear force, the bottom capacitors showed a maximum sensitivity of 57.370 fF/N and the top capacitor showed a comparably near-to-zero sensitivity of -11.743 fF/N, as expected. This sensitivity difference allows users to decouple the type of applied force and its orientation in the xy-plane through the proposed novel algorithm (workflow) for the first time.
- 23 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (24) , 30135-30142
Novel Multiaxial Force Decoupling Strategy in Vertically Stacked Force Sensors With Hybrid Fabrication Techniques
This study shows the development of a capacitive force sensor, which can not only detect multi-axial forces but also differentiate the applied normal and shear force due to its innovative structural design. The sensor contains five capacitors arranged in a specific pattern as a sensing unit with vertically stacked three polyethylene terephthalate substrates, two polydimethylsiloxane dielectrics, and several silver electrodes in each capacitor. In addition, one and four capacitors were put to the upper (hard) and lower (soft) layer, respectively. Comprehensive structure design, numerical simulation, hybrid fabrication (photolithography and inkjet printing), and analysis were performed in this work. Under the normal force, the top capacitor showed a sensitivity of 0.501 pF/N, while the bottom capacitors showed a comparably negligible sensitivity of 5.267 fF/N. Meanwhile, under the shear force, the bottom capacitors showed a maximum sensitivity of 57.370 fF/N and the top capacitor showed a comparably near-to-zero sensitivity of -11.743 fF/N, as expected. This sensitivity difference allows users to decouple the type of applied force and its orientation in the xy-plane through the proposed novel algorithm (workflow) for the first time.
- 5 September 2023
- Published by Springer Nature in Progress in Additive Manufacturing
- Vol. 9 (4) , 1003-1014
Fabrication of FFF 3D-printed surfaces for PMMA-based biomedical device employing the pre-processing optimization to eliminate the post-processing steps
- 5 September 2023
- Published by Springer Nature in Progress in Additive Manufacturing
- Vol. 9 (4) , 1003-1014
Fabrication of FFF 3D-printed surfaces for PMMA-based biomedical device employing the pre-processing optimization to eliminate the post-processing steps
- 13 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 7 (5) , 1-4
Novel Graphene Transfer Method to Silicone and its Sensing Application on Porous PDMS
In this work, we demonstrate a simple and sensitive parallel-plate capacitive pressure sensor fabricated on biocompatible, weather durable, elastic composite silicone and polyurethane substrate with porous polydimethylsiloxane (PDMS) dielectric made through a mixture of water as spacers. This sensor comprised a graphene electrode, which was developed through novel chemical vapor deposition on copper with hot press transfer process. The sensitivity of the sensor exhibits a positive correlation with the dielectric porosity. In addition, this device exhibits fast response time and wide dynamic window for applications. The highest sensitivity of 3.01 kPa −1 at 20% water concentration in PDMS for the dynamic range of 0–40 kPa was achieved with a response time of 0.25 s and detection resolution of 0.4 pF.
- 13 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 7 (5) , 1-4
Novel Graphene Transfer Method to Silicone and its Sensing Application on Porous PDMS
In this work, we demonstrate a simple and sensitive parallel-plate capacitive pressure sensor fabricated on biocompatible, weather durable, elastic composite silicone and polyurethane substrate with porous polydimethylsiloxane (PDMS) dielectric made through a mixture of water as spacers. This sensor comprised a graphene electrode, which was developed through novel chemical vapor deposition on copper with hot press transfer process. The sensitivity of the sensor exhibits a positive correlation with the dielectric porosity. In addition, this device exhibits fast response time and wide dynamic window for applications. The highest sensitivity of 3.01 kPa −1 at 20% water concentration in PDMS for the dynamic range of 0–40 kPa was achieved with a response time of 0.25 s and detection resolution of 0.4 pF.
- 11 January 2023
- Published by Springer Nature
- p. 151-163
Image Processing and Pattern Recognition of Micropores of Polysulfone Membrane for the Bio-separation of Viruses from Whole Blood
- 11 January 2023
- Published by Springer Nature
- p. 151-163
Image Processing and Pattern Recognition of Micropores of Polysulfone Membrane for the Bio-separation of Viruses from Whole Blood
- Open Access
- 2 December 2022
- Published by MDPI AG in Engineering Proceedings
- Vol. 31 (1) , 37
A Review on the Recent Developments in Passive Plasma Separators and Lab-on-Chip Microfluidic Devices
To ensure the country’s sustainable health recovery, viruses like COVID-19 need faster detection and sampling than the rate at which they spread. Blood plasma has proven to be an important and better clinical sample for the detection and diagnosis of various medical conditions as compared to whole blood. For in situ and in vivo health monitoring, plasma can be easily processed through microfluidic Lab-on-Chip (LOC) devices without the clotting that shortens the turnaround time and using minimum amounts of sample and reagents. The present review discusses the key properties of blood plasma as a perfect sample for the microfluidic LOC devices and the importance of passive plasma separators within any kind of LOC device as an embedded unit. The passive LOC plasma separators offer rapid extraction without external forces in the form of a miniaturized automated unit. This article compares various plasma separators on the basis of plasma extraction efficiency, fabrication techniques, and separation science utilized for hemolysis-free extraction. Recent developments in the area of passive bioseparators based on microfiltration and self-driven hydrodynamic and flow-cytometric approaches are discussed in detail.
- 2 December 2022
- Published by MDPI AG in Engineering Proceedings
- Vol. 31 (1) , 37
Open AccessA Review on the Recent Developments in Passive Plasma Separators and Lab-on-Chip Microfluidic Devices
To ensure the country’s sustainable health recovery, viruses like COVID-19 need faster detection and sampling than the rate at which they spread. Blood plasma has proven to be an important and better clinical sample for the detection and diagnosis of various medical conditions as compared to whole blood. For in situ and in vivo health monitoring, plasma can be easily processed through microfluidic Lab-on-Chip (LOC) devices without the clotting that shortens the turnaround time and using minimum amounts of sample and reagents. The present review discusses the key properties of blood plasma as a perfect sample for the microfluidic LOC devices and the importance of passive plasma separators within any kind of LOC device as an embedded unit. The passive LOC plasma separators offer rapid extraction without external forces in the form of a miniaturized automated unit. This article compares various plasma separators on the basis of plasma extraction efficiency, fabrication techniques, and separation science utilized for hemolysis-free extraction. Recent developments in the area of passive bioseparators based on microfiltration and self-driven hydrodynamic and flow-cytometric approaches are discussed in detail.