BHBarrie R. Hayes-Gill

Barrie R. Hayes-Gill

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Barrie R. Hayes-Gill has a total of 271 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Enhanced Thermal Microflow Sensor based on Gold Nanoparticle Functionalised Fabry–Pérot Interferometer with Partially Filled Copper(II) Oxide Nanoparticles Integrated with Polydimethylsiloxane

    by Ruirong Gong, Serhiy Korposh, Stephen P. Morgan, Yi Hsuan Chen, Lorelei Robertson, Chenyang He, Barrie Hayes-Gill, Ricardo Correia

    Real-time microflow velocity measurement is important in microfluidic systems where it regulates biochemical processes and in biomedical applications, where it indicates physiological state.,In this study, an optical fibre microflow sensor was developed based on a Fabry–Pérot interferometer (FPI) formed by a single-mode fibre (SMF) and a gold nanoparticle (AuNP)-functionalised silica capillary tube (SCT) that is partially filled with a copper oxide nanoparticle (CuONP)-embedded polydimethylsiloxane (PDMS)(CuO@PDMS) composite.,The AuNPs and CuONPs enhance the absorption of red laser light and generate heat, which the microfluid removes via convective heat transfer, establishing thermal equilibrium. Compared with AuNPs or CuONPs alone, the combination of both materials enhances the thermal absorption efficiency. Additionally, PDMS exhibits a high thermal expansion coefficient, which makes it highly responsive to temperature variations. The sensing principle follows the hot-wire flowmeter concept, in which convective heat transfer between the heated element and the surrounding fluid induces temperature changes that modify the PDMS volume and shift the FPI fringes, establishing correlation between flow velocity and heat dissipation.,Experimental evaluations were performed to characterise temperature sensitivity and nanoparticle-induced heating, and to examine the relationship between flow rate and wavelength shift. Based on the hot-wire flowmeter principle, monitoring the wavelength shift of the interference fringes enabled accurate measurement of microflow velocities ranging from 1.3 μL/s to 14.25 μL/s. The sensor demonstrated high temperature sensitivity of up to 8.71 nm/°C, good repeatability, and compactness. This method shows potential for in vivo biomedical diagnostics, particularly in narrow spaces requiring high-precision flow-rate detection.

  • Open Access

    Clinical Role of the Noninvasive Abdominal Fetal ECG in the Detection and Monitoring of Fetal Tachycardia

    by Sian Chivers, Nicolò Pini, Shayan Chowdhury, Ludovica Cicci, Trisha Vigneswaran, Vita Zidere, Sophie Maxwell, Grace Moriarty, William Regan, Eric Rosenthal, et al.

    BACKGROUND: Fetal tachycardias can cause adverse fetal outcomes including ventricular dysfunction, hydrops, and fetal demise. Postnatally, ECG is the gold standard, but, in fetal practice, echocardiography is used most frequently to diagnose and monitor fetal arrhythmias. Noninvasive extraction of the fetal ECG (fECG) may provide additional information about the electrophysiological mechanism and monitoring of intermittent arrhythmias. Signal processing advances could provide improved data quality impacting clinical translation. The aim of this study was to assess the fetus with known or suspected tachycardia using noninvasive abdominal fECG and correlate results with fetal echocardiography and postnatal ECG. METHODS: Prospective recruitment of pregnant participants with known or suspected fetal tachycardia in a tertiary fetal cardiology unit. Overnight fECG recording at home using the MonicaAN24 monitor was performed. Data processing using bespoke MATLAB scripts was undertaken to produce fetal heart rate and beat-to-beat rhythm strips. Comparison of fECG data with clinical data obtained using echocardiography and postnatal findings. Data are presented as median (interquartile range; range). RESULTS: Fifteen participants undertook 1 to 4 fECG recordings, giving a total of 23 recordings. Gestational age was 28.9 (23.9–34.3; 21–39.1) weeks. Duration of recording was 512 (380–609; 5–1259) minutes. Intermittent tachycardia was demonstrated on fetal heart rate graphs. Rhythm strips correctly identified short-ventriculoatrial and long-ventriculoatrial tachycardia, atrial flutter, and sinus rhythm with findings correlating with echocardiography. Postnatal ECG correlation was possible in 3. CONCLUSIONS: We have shown that rhythm strips of fECG signals can be extracted and correctly identify the electrical mechanism of arrhythmia in cases of fetal tachycardia. The potential to monitor fetal heart rate over a prolonged period is an advantage over current monitoring strategies for documentation of intermittent arrhythmias and gauging the response to medical therapy. These data will enable research to focus on improvement in signal quality, assessment of other arrhythmia subtypes, and real-time ambulatory monitoring of the fetal rhythm.


  • Open Access

    Ex vivo investigation of a smart endotracheal tube for identifying esophageal intubation

    by Brett Gadsby, Sergiy Korposh, Ricardo Correia, Chenyang He, Barrie R. Hayes-Gill, Andrew M. Norris, Jonathan G. Hardman, David W. Hewson, Stephen P. Morgan

    Tracheal intubation secures a patient’s airway, delivering mechanical ventilation, oxygen, anesthesia, and medications. Unrecognized esophageal intubation (UOI) refers to the incorrect and unnoticed placement of the endotracheal tube (ETT) in the esophagus. Medical complications occur within minutes of UOI and can result in cardiac arrest, severe brain damage, or death due to the rapid onset of hypoxia.1,2 The current gold standard for confirming tube placement in the trachea is based on visual confirmation of the tube passing the vocal cords and the presence of a continuous carbon dioxide waveform from exhaled gas. However, visual confirmation is not always reliable, and CO2 waveform analysis can be compromised by low cardiac output, equipment issues, and misinterpretation, leading to incorrect tube placement identification in 5% to 15% of cases.3,4 These issues are particularly relevant in emergency treatment situations.5 Conditions such as obesity, swollen airways, limited neck mobility, and bleeding can further complicate airway management and increase the risk of UOI.6


  • Open Access

    Generative adversarial networks with fully connected layers to denoise PPG signals

    by Itzel A Avila Castro, Helder P Oliveira, Ricardo Correia, Barrie Hayes-Gill, Stephen P Morgan, Serhiy Korposh, David Gomez, Tania Pereira

    Objective.The detection of arterial pulsating signals at the skin periphery with Photoplethysmography (PPG) are easily distorted by motion artifacts. This work explores the alternatives to the aid of PPG reconstruction with movement sensors (accelerometer and/or gyroscope) which to date have demonstrated the best pulsating signal reconstruction. Approach. A generative adversarial network with fully connected layers is proposed for the reconstruction of distorted PPG signals. Artificial corruption was performed to the clean selected signals from the BIDMC Heart Rate dataset, processed from the larger MIMIC II waveform database to create the training, validation and testing sets. Main results. The heart rate (HR) of this dataset was further extracted to evaluate the performance of the model obtaining a mean absolute error of 1.31 bpm comparing the HR of the target and reconstructed PPG signals with HR between 70 and 115 bpm. Significance. The model architecture is effective at reconstructing noisy PPG signals regardless the length and amplitude of the corruption introduced. The performance over a range of HR (70–115 bpm), indicates a promising approach for real-time PPG signal reconstruction without the aid of acceleration or angular velocity inputs.


  • Open Access

    Respiratory Rate Monitoring via a Fibre Bragg Grating-Embedded Respirator Mask with a Wearable Miniature Interrogator

    by Nat Limweshasin, Itzel Avila Castro, Serhiy Korposh, Stephen P. Morgan, Barrie R. Hayes-Gill, Mark A. Faghy, Ricardo Correia

    A respiration rate (RR) monitoring system was created by integrating a Fibre Bragg Grating (FBG) optical fibre sensor into a respirator mask. The system exploits the sensitivity of an FBG to temperature to identify an individual’s RR by measuring airflow temperature variation near the nostrils and mouth. To monitor the FBG response, a portable, battery-powered, wireless miniature interrogator system was developed to replace a relatively bulky benchtop interrogator used in previous studies. A healthy volunteer study was conducted to evaluate the performance of the developed system (10 healthy volunteers). Volunteers were asked to perform normal breathing whilst simultaneously wearing the system and a reference spirometer for 120 s. Individual breaths are then identified using a peak detection algorithm. The result showed that the number of breaths detected by both devices matched exactly (100%) across all volunteer trials.


  • Open Access

    Comparing peripheral limb and forehead vital sign monitoring in newborn infants at birth

    by Suvvi K. Narayana Swamy, Simon J. Stockwell, Chong Liu, Caroline Henry, Lara Shipley, Carole Ward, Siavash Mirahmadi, Ricardo Correia, Stephen P. Morgan, John A. Crowe, et al.

    Background: To study the feasibility of measuring heart rate (HR) and oxygen saturation (SpO 2 ) on the forehead, during newborn transition at birth, and to compare these measurements with those obtained from the wrist. Methods: Vital signs were measured and compared between forehead-mounted reflectance (remittance) photoplethysmography sensor (fhPPG) and a wrist-mounted pulse oximeter sensor (wrPO), from 20 enrolled term newborns born via elective caesarean section, during the first 10 min of life. Results: From the datasets available ( n = 13), the median (IQR) sensor placement times for fhPPG, ECG and wrPO were 129 (70) s, 143 (68) s, and 159 (76) s, respectively, with data recorded for up to 10 min after birth. The success rate (percentage of total possible HR values reported once sited) of fhPPG (median = 100%) was higher compared to wrPO (median = 69%) during the first 6 min of life ( P < 0.005). Both devices exhibited good HR agreement with ECG, achieving >95% agreement by 3 (fhPPG) and 4 (wrPO) min. SpO 2 for fhPPG correlated with wrPO ( r = 0.88), but there were significant differences in SpO 2 between the two devices between 3 and 8 min ( P < 0.005), with less variance observed with fhPPG SpO 2 . Conclusion: In the period of newborn transition at birth in healthy term infants, forehead measurement of vital signs was feasible and exhibited greater HR accuracy and higher estimated SpO 2 values compared to wrist-sited pulse oximetry. Further investigation of forehead monitoring based on the potential benefits over peripheral monitoring is warranted. Impact: This study demonstrates the feasibility of continuously monitoring heart rate and oxygen saturation from an infant’s forehead in the delivery room immediately after birth. Significantly higher SpO 2 measurements were observed from the forehead than the wrist during the transition from foetal to newborn life. Continuous monitoring of vital signs from the forehead could become a valuable tool to improve the delivery of optimal care provided for newborns at birth.


  • Open Access

    Exploring the bias: how skin color influences oxygen saturation readings via Monte Carlo simulations

    by Suvvi K. Narayana Swamy, Chong Liu, Ricardo Correia, Barrie R. Hayes-Gill, Stephen P. Morgan

    Continuous and accurate monitoring of physiological changes is critical in medical settings, making peripheral oxygen saturation (SpO2) a crucial vital sign in patient treatment and care.1 SpO2 serves as an indicator of the overall functioning of the body’s main organ systems, and its continuous observation is key for early problem detection and timely delivery of treatment and care. The gold standard for measuring arterial blood oxygen saturation (SaO2) is arterial blood gas (ABG) sampling, a technique performed using a blood gas analyzer. This method is, however, intermittent, expensive, and time-consuming and involves invasive procedures. By contrast, pulse oximetry offers an alternative technology that is a continuous, inexpensive, pain-free, and non-invasive way of monitoring SpO2. This technique is realized using a pulse oximeter (PO), which operates by transmitting light into the tissue and measuring photoplethysmography (PPG) signals that represent light modulated by cardiac-synchronized variations in the arterial blood volume.2 Pulse oximeters (POs) commonly utilize red (660 nm) and infrared (IR, 940 nm) light wavelengths to measure the absorption of deoxyhemoglobin (Hbb) and oxyhemoglobin (HbO2) in the blood, respectively. The basis of pulse oximetry is the “ratio of ratios” R of the pulsatile (AC)/non-pulsatile (DC) detected light components at red and IR wavelengths, obtained from PPG signals.3 The relationship between R and SaO2 is usually derived via calibration with ABG during controlled desaturation events.4 It is a simple, yet powerful technique in estimating continuous blood oxygen saturation readings in real time that has gained significant use in various clinical and remote patient monitoring settings.


  • Open Access

    Forehead monitoring of heart rate in neonatal intensive care

    by S. J. Stockwell, T. C. Kwok, S. P. Morgan, D. Sharkey, B. R. Hayes-Gill

    Heart rate is an extremely important physiological parameter to measure in critically unwell infants, as it is the main physiological marker that changes in response to a change in infant condition. Heart rate is routinely measured peripherally on a limb with a pulse oximeter. However, when infants are critically unwell, the blood supply to these peripheries is reduced in preference for central perfusion of vital organs such as the brain and heart. Measurement of heart rate with a reflection mode photoplethysmogram (PPG) sensor on the forehead could help minimise this problem and make it easier for other important medical equipment, such as cannulas, to be placed on the limbs. This study compares heart rates measured with a forehead-based PPG sensor against a wrist-based PPG sensor in 19 critically unwell infants in neonatal intensive care collecting 198 h of data. The two heart rates were compared using positive percentage agreement, Spearman’s correlation coefficient and Bland-Altman analysis. The forehead PPG sensor showed good agreement with the wrist-based PPG sensor with limits of agreement of 8.44 bpm, bias of −0.22 bpm; positive percentage agreement of 98.87%; and Spearman’s correlation coefficient of 0.9816. The analysis demonstrates that the forehead is a reliable alternative location for measuring vital signs using the PPG.


  • Open Access

    Fibre Bragg Grating Based Interface Pressure Sensor for Compression Therapy

    by James A. Bradbury, Qimei Zhang, Francisco U. Hernandez Ledezma, Ricardo Correia, Serhiy Korposh, Barrie R. Hayes-Gill, Ferdinand Tamoué, Alison Parnham, Simon A. McMaster, Stephen P. Morgan

    Compression therapy is widely used as the gold standard for management of chronic venous insufficiency and venous leg ulcers, and the amount of pressure applied during the compression therapy is crucial in supporting healing. A fibre optic pressure sensor using Fibre Bragg Gratings (FBGs) is developed in this paper to measure sub-bandage pressure whilst removing cross-sensitivity due to strain in the fibre and temperature. The interface pressure is measured by an FBG encapsulated in a polymer and housed in a textile to minimise discomfort for the patient. The repeatability of a manual fabrication process is investigated by fabricating and calibrating ten sensors. A customized calibration setup consisting of a programmable translation stage and a weighing scale gives sensitivities in the range 0.4–1.5 pm/mmHg (2.6–11.3 pm/kPa). An alternative calibration method using a rigid plastic cylinder and a blood pressure cuff is also demonstrated. Investigations are performed with the sensor under a compression bandage on a phantom leg to test the response of the sensor to changing pressures in static situations. Measurements are taken on a human subject to demonstrate changes in interface pressure under a compression bandage during motion to mimic a clinical application. These results are compared to the current gold standard medical sensor using a Bland–Altman analysis, with a median bias ranging from −4.6 to −20.4 mmHg, upper limit of agreement (LOA) from −13.5 to 2.7 mmHg and lower LOA from −32.4 to −7.7 mmHg. The sensor has the potential to be used as a training tool for nurses and can be left in situ to monitor bandage pressure during compression therapy.


  • Open Access

    Feasibility of a Novel ECG Electrode Placement Method in Newborn Infants

    by Caroline Henry, Lara Shipley, Stephen Morgan, John A. Crowe, James Carpenter, Barrie Hayes-Gill, Don Sharkey

    Background: International newborn resuscitation guidelines recommend electrocardiogram (ECG) heart rate (HR) monitoring at birth. We evaluated the application time of pre-set ECG electrodes fixed to a polyethene patch allowing adhesive-free attachment to the wet skin of the newborn chest. Objectives: Using a three-electrode pre-set ECG patch configuration, application success was calculated using video analysis and measured at three time points, the time to (1) apply electrodes; (2) detect recognizable QRS complexes after application; and (3) display a HR after application. Method: A prospective observational study in two UK tertiary maternity units was undertaken with 71 newborns including 23 who required resuscitation. Results: The median (IQR) time for ECG patch application was 8 (6–10) seconds, detection of recognizable QRS complexes 8 (2–12) seconds, and time to output HR was 23 (15–37) seconds. Conclusion: Pre-set ECG chest electrodes allow rapid HR information at birth without electrode detachment or compromising skin integrity.