Rudeger H. T. Wilke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rudeger H. T. Wilke has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Albuquerque Sandia National Laboratories (Snl-Nm)
2 shared publications- Raegan L. Johnson-Wilke
National Institute of Standards and Technology, Boulder, CO, USA
2 shared publications Usdoe National Nuclear Security Administration (Nnsa)
2 shared publications- Alexey Vikhlinin
Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138, USA
1 shared publication - Amanda Baker
Department of Neurological Surgery and Montefiore-Einstein Cerebrovascular Research Laboratory, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY (M.A.E., A. Baker, D.A.).
1 shared publication - Brian D. Ramsey
NASA Marshall Space Flight Center
1 shared publication
Latest Publications
- Open Access
- 1 October 2026
- Published by Office of Scientific and Technical Information (OSTI)
Facilitating the use of Common Test Definitions by Converting Test Sequences to IEEE Standards using Large Language Models
[TE2.1][TE2.2]This report describes the progress of a prototype GUI, nicknamed LightStar, that enables engineers to convert existing test scripts into IEEE-compliant, XML-based documents, as well use these documents to automatically generate executable scripts.
- 1 October 2026
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessFacilitating the use of Common Test Definitions by Converting Test Sequences to IEEE Standards using Large Language Models
[TE2.1][TE2.2]This report describes the progress of a prototype GUI, nicknamed LightStar, that enables engineers to convert existing test scripts into IEEE-compliant, XML-based documents, as well use these documents to automatically generate executable scripts.
- Open Access
- 1 September 2026
- Published by Office of Scientific and Technical Information (OSTI)
Leveraging Gaussian Mixture Models for Detecting Anomalies in Time-Series Data
Test systems must be capable of classifying measured data as expected or anomalous in real time. Anomalous results may portend system failure, and, if undetected, may result in damage to the unit, test equipment, or potential harm to personnel. This report investigates the use of Gaussian Mixture Models (GMMs) as a clustering tool in classifying time-series data.
- 1 September 2026
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessLeveraging Gaussian Mixture Models for Detecting Anomalies in Time-Series Data
Test systems must be capable of classifying measured data as expected or anomalous in real time. Anomalous results may portend system failure, and, if undetected, may result in damage to the unit, test equipment, or potential harm to personnel. This report investigates the use of Gaussian Mixture Models (GMMs) as a clustering tool in classifying time-series data.
- Open Access
- 2 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 6 (10) , 1555-1560
Fabrication of Wound Capacitors Using Flexible Alkali-Free Glass
Alkali-free glasses, which exhibit high energy storage densities (~35 J/cc), present a unique opportunity to couple high temperature stability with high breakdown strength, and thus provide an avenue for capacitor applications with stringent temperature and power requirements. Realizing the potential of these materials in kilovolt class capacitors with >1 J/cc recoverable energy density requires novel packaging strategies that incorporate these extremely fragile dielectrics. In this paper, we demonstrate the feasibility of fabricating wound capacitors using 50-μm-thick glass. Two capacitors were fabricated from 2.8-m-long ribbons of thin (50 μm) glass wound into 125-140-mm-diameter spools. The capacitors exhibit a capacitance of 70-75 nF with loss tangents below 1%. The wound capacitors can operate up to 1 kV and show excellent temperature stability to 150 °C. By improving the end terminations, the self-resonance can be shifted to above 1 MHz, indicating that these materials may be useful for pulsed power applications with microsecond discharge times.
- 2 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 6 (10) , 1555-1560
Open AccessFabrication of Wound Capacitors Using Flexible Alkali-Free Glass
Alkali-free glasses, which exhibit high energy storage densities (~35 J/cc), present a unique opportunity to couple high temperature stability with high breakdown strength, and thus provide an avenue for capacitor applications with stringent temperature and power requirements. Realizing the potential of these materials in kilovolt class capacitors with >1 J/cc recoverable energy density requires novel packaging strategies that incorporate these extremely fragile dielectrics. In this paper, we demonstrate the feasibility of fabricating wound capacitors using 50-μm-thick glass. Two capacitors were fabricated from 2.8-m-long ribbons of thin (50 μm) glass wound into 125-140-mm-diameter spools. The capacitors exhibit a capacitance of 70-75 nF with loss tangents below 1%. The wound capacitors can operate up to 1 kV and show excellent temperature stability to 150 °C. By improving the end terminations, the self-resonance can be shifted to above 1 MHz, indicating that these materials may be useful for pulsed power applications with microsecond discharge times.
- Open Access
- 3 October 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9208, 920807
Development status of adjustable grazing incidence optics for 0.5 arcsecond x-ray imaging
We describe progress in the development of adjustable grazing incidence X-ray optics for 0.5 arcsec resolution cosmic X-ray imaging. To date, no optics technology is available to blend high resolution imaging like the Chandra X-ray Observatory, with square meter collecting area. Our approach to achieve these goals simultaneously is to directly deposit thin film piezoelectric actuators on the back surface of thin, lightweight Wolter-I or Wolter- Schwarschild mirror segments. The actuators are used to correct mirror figure errors due to fabrication, mounting and alignment, using calibration and a one-time figure adjustment on the ground. If necessary, it will also be possible to correct for residual gravity release and thermal effects on-orbit. In this paper we discuss our most recent results measuring influence functions of the piezoelectric actuators using a Shack-Hartmann wavefront sensor. We describe accelerated and real-time lifetime testing of the piezoelectric material, and we also discuss changes to, and recent results of, our simulations of mirror correction.
- 3 October 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9208, 920807
Open AccessDevelopment status of adjustable grazing incidence optics for 0.5 arcsecond x-ray imaging
We describe progress in the development of adjustable grazing incidence X-ray optics for 0.5 arcsec resolution cosmic X-ray imaging. To date, no optics technology is available to blend high resolution imaging like the Chandra X-ray Observatory, with square meter collecting area. Our approach to achieve these goals simultaneously is to directly deposit thin film piezoelectric actuators on the back surface of thin, lightweight Wolter-I or Wolter- Schwarschild mirror segments. The actuators are used to correct mirror figure errors due to fabrication, mounting and alignment, using calibration and a one-time figure adjustment on the ground. If necessary, it will also be possible to correct for residual gravity release and thermal effects on-orbit. In this paper we discuss our most recent results measuring influence functions of the piezoelectric actuators using a Shack-Hartmann wavefront sensor. We describe accelerated and real-time lifetime testing of the piezoelectric material, and we also discuss changes to, and recent results of, our simulations of mirror correction.
- 28 August 2008
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 8 (10) , 3555
p-Type Cu−Ti−O Nanotube Arrays and Their Use in Self-Biased Heterojunction Photoelectrochemical Diodes for Hydrogen Generation
- 28 August 2008
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 8 (10) , 3555
p-Type Cu−Ti−O Nanotube Arrays and Their Use in Self-Biased Heterojunction Photoelectrochemical Diodes for Hydrogen Generation