Raegan L. Johnson-Wilke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Raegan L. Johnson-Wilke has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Anna E. Fox
National Institute of Standards and Technology
5 shared publications - Paul D. Dresselhaus
National Institute of Standards and Technology, Boulder, CO, USA
5 shared publications - Samuel P. Benz
National Institute of Standards and Technology
5 shared publications - Nathan Edward Flowers-Jacobs
National Institute of Standards and Technology, Boulder, CO, USA
3 shared publications - Alain Rüfenacht
National Institute of Standards and Technology
2 shared publications - Alain Rüfenacht
National Institute of Standards and Technology, Boulder, CO, USA
2 shared publications
Latest Publications
- Open Access
- 11 June 2026
- Published by IOP Publishing in Metrologia
- Vol. 63 (3)
Leakage Current Effects with Programmable Josephson Voltage Standards
This work presents the results of evaluating and measuring the dc leakage effects associated with Programmable Josephson Voltage Standards (PJVS) caused by unintended currents flowing in the circuit. Two types of leakage error can occur in PJVS systems: 1) involves leakage currents to Earth ground, which typically result from the finite resistance of cable insulation and the bias electronics, and 2) leakage paths on the precision output leads giving rise to a voltage divider effect between the leads and the load impedance. Both effects impact the PJVS's measurement accuracy and must be monitored regularly. We have developed assessment methods, including both manual and automated measurements, that should be applied to any disseminated PJVS systems currently in use. If these recommended techniques are followed and the leakage current to Earth ground remains below 150 pA when the PJVS array is biased at 10 V, the resulting voltage error at the room-temperature terminals will be less than 0.2 nV.
- 11 June 2026
- Published by IOP Publishing in Metrologia
- Vol. 63 (3)
Open AccessLeakage Current Effects with Programmable Josephson Voltage Standards
This work presents the results of evaluating and measuring the dc leakage effects associated with Programmable Josephson Voltage Standards (PJVS) caused by unintended currents flowing in the circuit. Two types of leakage error can occur in PJVS systems: 1) involves leakage currents to Earth ground, which typically result from the finite resistance of cable insulation and the bias electronics, and 2) leakage paths on the precision output leads giving rise to a voltage divider effect between the leads and the load impedance. Both effects impact the PJVS's measurement accuracy and must be monitored regularly. We have developed assessment methods, including both manual and automated measurements, that should be applied to any disseminated PJVS systems currently in use. If these recommended techniques are followed and the leakage current to Earth ground remains below 150 pA when the PJVS array is biased at 10 V, the resulting voltage error at the room-temperature terminals will be less than 0.2 nV.
- 16 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 73 (11) , 8942-8955
Cryogenic On-Chip In Situ S -Parameter Calibration Using Superconducting Coplanar Waveguides
This article presents a new multiimpedance-state line (MISL) in situ scattering parameter (S-parameter) calibration technique using on-chip superconducting transmission lines at 4 K that enables cryogenic calibration in a fixed signal path without the need for cryogenic switches or a cryogenic probe station. The method uses coplanar waveguide (CPW) models based on various impedance states of niobium (Nb), which has zero dc resistance below 9 K and a monotonically increasing resistance from 10 K to room temperature. The different impedance states are accessed by heating the 4 K stage of a cryostat and injecting up to 245 mA of current into the line. Using these states, we solve for the unknowns in an eight-term error model through a least-squares analysis. We first validate the MISL calibration technique by comparing it with short-open-load-reciprocal (SOLR) calibrated measurements in a cryogenic probe station, finding transmission agreement within 0.2 dB and uncertainty overlap for nearly all frequencies up to 26.5 GHz. We then apply the method to calibrate Nb CPWs with and without embedded Josephson junctions (JJs), using a fixed wire bonded connection, and without the use of cryogenic switches or movable probes. Strong agreement with the CPW models is demonstrated, with uncertainty overlap and differences below 0.1 dB up to 4.6 GHz without JJs and up to 2.4 GHz with JJs; resonances cause interruptions beyond these frequencies.
- 16 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 73 (11) , 8942-8955
Cryogenic On-Chip In Situ S -Parameter Calibration Using Superconducting Coplanar Waveguides
This article presents a new multiimpedance-state line (MISL) in situ scattering parameter (S-parameter) calibration technique using on-chip superconducting transmission lines at 4 K that enables cryogenic calibration in a fixed signal path without the need for cryogenic switches or a cryogenic probe station. The method uses coplanar waveguide (CPW) models based on various impedance states of niobium (Nb), which has zero dc resistance below 9 K and a monotonically increasing resistance from 10 K to room temperature. The different impedance states are accessed by heating the 4 K stage of a cryostat and injecting up to 245 mA of current into the line. Using these states, we solve for the unknowns in an eight-term error model through a least-squares analysis. We first validate the MISL calibration technique by comparing it with short-open-load-reciprocal (SOLR) calibrated measurements in a cryogenic probe station, finding transmission agreement within 0.2 dB and uncertainty overlap for nearly all frequencies up to 26.5 GHz. We then apply the method to calibrate Nb CPWs with and without embedded Josephson junctions (JJs), using a fixed wire bonded connection, and without the use of cryogenic switches or movable probes. Strong agreement with the CPW models is demonstrated, with uncertainty overlap and differences below 0.1 dB up to 4.6 GHz without JJs and up to 2.4 GHz with JJs; resonances cause interruptions beyond these frequencies.
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-7
Dual-Frequency-Bias Programmable Josephson Voltage Standard Circuit
This paper presents a 2 V programmable Josephson voltage standard with dual microwave frequency inputs and multiple output taps. The design provides three main features: (1) output voltages with nanovolt resolution, (2) the ability to perform a microwave frequency self-check based on a null voltage measurement, and (3) additional voltage output taps providing simultaneous 10:1 (or 5:1) divided voltage reference for resistive divider calibration. With low heat dissipation this device is well suited for implementation with a compact cryocooler as a turnkey traveling system.
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-7
Dual-Frequency-Bias Programmable Josephson Voltage Standard Circuit
This paper presents a 2 V programmable Josephson voltage standard with dual microwave frequency inputs and multiple output taps. The design provides three main features: (1) output voltages with nanovolt resolution, (2) the ability to perform a microwave frequency self-check based on a null voltage measurement, and (3) additional voltage output taps providing simultaneous 10:1 (or 5:1) divided voltage reference for resistive divider calibration. With low heat dissipation this device is well suited for implementation with a compact cryocooler as a turnkey traveling system.
- 26 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
Impact of Leakage Currents on Voltage Accuracy in the Josephson Arbitrary Waveform Synthesizer
The voltage errors related to ac leakage currents in Josephson arbitrary waveform synthesizer (JAWS) systems are significant contributors to the overall system accuracy. These ac leakage currents flow through paths (typically to ground) that are not part of the intended measurement circuit. This paper examines output voltage discrepancies between two different but nominally identical circuit halves on a single JAWS circuit and shows that this discrepancy is dominated by ac leakage currents through the stray capacitance in the compensation leads. Methods to minimize these voltage errors will be discussed along with their associated limitations.
- 26 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
Impact of Leakage Currents on Voltage Accuracy in the Josephson Arbitrary Waveform Synthesizer
The voltage errors related to ac leakage currents in Josephson arbitrary waveform synthesizer (JAWS) systems are significant contributors to the overall system accuracy. These ac leakage currents flow through paths (typically to ground) that are not part of the intended measurement circuit. This paper examines output voltage discrepancies between two different but nominally identical circuit halves on a single JAWS circuit and shows that this discrepancy is dominated by ac leakage currents through the stray capacitance in the compensation leads. Methods to minimize these voltage errors will be discussed along with their associated limitations.
- Open Access
- 29 July 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (5)
AC metrology applications of the Josephson effect
The performance of programmable voltage signals that exploit the quantum behavior of superconducting Josephson junctions continues to improve and enhance measurements in metrology, communications, and quantum control. We review advances in pulse-driven digital synthesis techniques with Josephson-junction-based devices. Quantum-based synthesis of voltage waveforms has been demonstrated at frequencies up to 3 GHz and rms amplitudes up to 4 V. Josephson pulse generators have also been used to control and characterize superconducting qubits.
- 29 July 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (5)
Open AccessAC metrology applications of the Josephson effect
The performance of programmable voltage signals that exploit the quantum behavior of superconducting Josephson junctions continues to improve and enhance measurements in metrology, communications, and quantum control. We review advances in pulse-driven digital synthesis techniques with Josephson-junction-based devices. Quantum-based synthesis of voltage waveforms has been demonstrated at frequencies up to 3 GHz and rms amplitudes up to 4 V. Josephson pulse generators have also been used to control and characterize superconducting qubits.
- Open Access
- 2 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 6 (10) , 1555-1560
Fabrication of Wound Capacitors Using Flexible Alkali-Free Glass
Alkali-free glasses, which exhibit high energy storage densities (~35 J/cc), present a unique opportunity to couple high temperature stability with high breakdown strength, and thus provide an avenue for capacitor applications with stringent temperature and power requirements. Realizing the potential of these materials in kilovolt class capacitors with >1 J/cc recoverable energy density requires novel packaging strategies that incorporate these extremely fragile dielectrics. In this paper, we demonstrate the feasibility of fabricating wound capacitors using 50-μm-thick glass. Two capacitors were fabricated from 2.8-m-long ribbons of thin (50 μm) glass wound into 125-140-mm-diameter spools. The capacitors exhibit a capacitance of 70-75 nF with loss tangents below 1%. The wound capacitors can operate up to 1 kV and show excellent temperature stability to 150 °C. By improving the end terminations, the self-resonance can be shifted to above 1 MHz, indicating that these materials may be useful for pulsed power applications with microsecond discharge times.
- 2 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 6 (10) , 1555-1560
Open AccessFabrication of Wound Capacitors Using Flexible Alkali-Free Glass
Alkali-free glasses, which exhibit high energy storage densities (~35 J/cc), present a unique opportunity to couple high temperature stability with high breakdown strength, and thus provide an avenue for capacitor applications with stringent temperature and power requirements. Realizing the potential of these materials in kilovolt class capacitors with >1 J/cc recoverable energy density requires novel packaging strategies that incorporate these extremely fragile dielectrics. In this paper, we demonstrate the feasibility of fabricating wound capacitors using 50-μm-thick glass. Two capacitors were fabricated from 2.8-m-long ribbons of thin (50 μm) glass wound into 125-140-mm-diameter spools. The capacitors exhibit a capacitance of 70-75 nF with loss tangents below 1%. The wound capacitors can operate up to 1 kV and show excellent temperature stability to 150 °C. By improving the end terminations, the self-resonance can be shifted to above 1 MHz, indicating that these materials may be useful for pulsed power applications with microsecond discharge times.
- Open Access
- 3 October 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9208, 920807
Development status of adjustable grazing incidence optics for 0.5 arcsecond x-ray imaging
We describe progress in the development of adjustable grazing incidence X-ray optics for 0.5 arcsec resolution cosmic X-ray imaging. To date, no optics technology is available to blend high resolution imaging like the Chandra X-ray Observatory, with square meter collecting area. Our approach to achieve these goals simultaneously is to directly deposit thin film piezoelectric actuators on the back surface of thin, lightweight Wolter-I or Wolter- Schwarschild mirror segments. The actuators are used to correct mirror figure errors due to fabrication, mounting and alignment, using calibration and a one-time figure adjustment on the ground. If necessary, it will also be possible to correct for residual gravity release and thermal effects on-orbit. In this paper we discuss our most recent results measuring influence functions of the piezoelectric actuators using a Shack-Hartmann wavefront sensor. We describe accelerated and real-time lifetime testing of the piezoelectric material, and we also discuss changes to, and recent results of, our simulations of mirror correction.
- 3 October 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9208, 920807
Open AccessDevelopment status of adjustable grazing incidence optics for 0.5 arcsecond x-ray imaging
We describe progress in the development of adjustable grazing incidence X-ray optics for 0.5 arcsec resolution cosmic X-ray imaging. To date, no optics technology is available to blend high resolution imaging like the Chandra X-ray Observatory, with square meter collecting area. Our approach to achieve these goals simultaneously is to directly deposit thin film piezoelectric actuators on the back surface of thin, lightweight Wolter-I or Wolter- Schwarschild mirror segments. The actuators are used to correct mirror figure errors due to fabrication, mounting and alignment, using calibration and a one-time figure adjustment on the ground. If necessary, it will also be possible to correct for residual gravity release and thermal effects on-orbit. In this paper we discuss our most recent results measuring influence functions of the piezoelectric actuators using a Shack-Hartmann wavefront sensor. We describe accelerated and real-time lifetime testing of the piezoelectric material, and we also discuss changes to, and recent results of, our simulations of mirror correction.