Goran Radenković
Research Subjects
Goran Radenković has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Miloš Madić
Faculty of Mechanical Engineering in Niš, University of Niš, 18000 Niš, Serbia
3 shared publications Dusan Petkovic
Faculty of Mechanical Engineering, Nis
2 shared publications- Dušan Lj. Petković
Faculty of Mechanical Engineering, Nis
2 shared publications Petar Djekić
2 shared publicationsZ. Cvijović
2 shared publicationsAleksandar Mitic
Medical Faculty, Clinic of Dentistry, Department of Restorative Dentistry and Endodontics, Niš
1 shared publication
Latest Publications
- Open Access
- 15 March 2026
- Published by University of Nis Faculty of Medicine in AFMN Biomedicine
- Vol. 43 (1) , 65-75
EXPRESSION OF ANOCTAMIN-1 IN HUMAN GASTROINTESTINAL TRACT DURING EMBRYONIC AND FETAL DEVELOPMENT
Anoctamin 1 (ANO1, TMEM16A) is a transmembrane protein belonging to the ANO family, with a role in the formation of calcium-activated chloride channels (CaCC). It is included in the regulation of physiological processes such as muscle contraction, gastrointestinal motility, secretion, and electrical excitability. Also, recent data suggest that ANO1 is a specific marker for interstitial cells of Cajal (ICC). The aim of the paper was to examine the spatial and temporal distribution of ANO1 in the human stomach, small intestine, and large intestine during embryofetal development as a potential marker for the differentiation of ICC and smooth muscle cells. As a material, we used 2 embryos and samples from 21 fetuses. The tissue samples were routinely processed into paraffin blocks, and 5 µm-thick sections were immunostained for ANO1. Our results show that ANO1 appears during embryonic development (8th week), and its expression continues through the fetal stages. Epithelial, endothelial and ICC cells consistently expressed ANO1 in all examined samples. Smooth muscle cells showed strong expression in muscularis propria, however by the 25th week this immunopositivity was absent from outer muscle layers in stomach and large intestine. In conclusion, ANO1 can be considered as a reliable marker for following the differentiation of SMC and ICC during embryonic and fetal development.
- 15 March 2026
- Published by University of Nis Faculty of Medicine in AFMN Biomedicine
- Vol. 43 (1) , 65-75
Open AccessEXPRESSION OF ANOCTAMIN-1 IN HUMAN GASTROINTESTINAL TRACT DURING EMBRYONIC AND FETAL DEVELOPMENT
Anoctamin 1 (ANO1, TMEM16A) is a transmembrane protein belonging to the ANO family, with a role in the formation of calcium-activated chloride channels (CaCC). It is included in the regulation of physiological processes such as muscle contraction, gastrointestinal motility, secretion, and electrical excitability. Also, recent data suggest that ANO1 is a specific marker for interstitial cells of Cajal (ICC). The aim of the paper was to examine the spatial and temporal distribution of ANO1 in the human stomach, small intestine, and large intestine during embryofetal development as a potential marker for the differentiation of ICC and smooth muscle cells. As a material, we used 2 embryos and samples from 21 fetuses. The tissue samples were routinely processed into paraffin blocks, and 5 µm-thick sections were immunostained for ANO1. Our results show that ANO1 appears during embryonic development (8th week), and its expression continues through the fetal stages. Epithelial, endothelial and ICC cells consistently expressed ANO1 in all examined samples. Smooth muscle cells showed strong expression in muscularis propria, however by the 25th week this immunopositivity was absent from outer muscle layers in stomach and large intestine. In conclusion, ANO1 can be considered as a reliable marker for following the differentiation of SMC and ICC during embryonic and fetal development.
- 15 December 2021
- Published by Faculty of Technical Sciences in Advanced Technologies & Materials
- Vol. 46 (2) , 37-41
Knee Prosthesis Biomaterial Selection by Using MCDM Solver
Biomaterials are a special class of contemporary materials used to make prostheses, parts of organs or to replace entire organs. They are used to replace soft and hard tissues. Metal biomaterials are mostly used to replace hard bone tissues and joints. There is no ideal substitution for natural biological material, but each of the biomaterials has a number of advantages and disadvantages. The problem of choosing the most favorable biomaterial is a complex process of multi‐criteria decision‐making, which requires a lot of knowledge and experience. In order to help decision makers in solving this complex task, a decision support system named MCDM Solver is proposed. MCDM Solver is used in decision‐making process to rank the biomaterials with respect to several criteria. In this paper, MCDM Solver was used to select knee prosthesis material.
- 15 December 2021
- Published by Faculty of Technical Sciences in Advanced Technologies & Materials
- Vol. 46 (2) , 37-41
Knee Prosthesis Biomaterial Selection by Using MCDM Solver
Biomaterials are a special class of contemporary materials used to make prostheses, parts of organs or to replace entire organs. They are used to replace soft and hard tissues. Metal biomaterials are mostly used to replace hard bone tissues and joints. There is no ideal substitution for natural biological material, but each of the biomaterials has a number of advantages and disadvantages. The problem of choosing the most favorable biomaterial is a complex process of multi‐criteria decision‐making, which requires a lot of knowledge and experience. In order to help decision makers in solving this complex task, a decision support system named MCDM Solver is proposed. MCDM Solver is used in decision‐making process to rank the biomaterials with respect to several criteria. In this paper, MCDM Solver was used to select knee prosthesis material.
- 15 March 2018
- Published by Medical Faculty, University in Nis in Acta Medica Medianae
- Vol. 57 (1) , 25-32
THE INFLUENCE OF A T IME PERIOD ON BONDING STRENGTH OF PLACED BRACKETS
- 15 March 2018
- Published by Medical Faculty, University in Nis in Acta Medica Medianae
- Vol. 57 (1) , 25-32
THE INFLUENCE OF A T IME PERIOD ON BONDING STRENGTH OF PLACED BRACKETS
- Open Access
- 1 January 2018
- Published by National Library of Serbia in Hemijska industrija
- Vol. 72 (3) , 129-137
Effects of water boiling, microwave, and water bath post-polymerization on mechanical properties of acrylic denture resins
Acrylic restorations in the mouth are exposed to strong occlusal forces. Their mechanical properties depend on the type and method of their polymerization. The aim of this study is a comparative analysis of mechanical properties (flexural strength and modulus of elasticity) of acrylic materials before and after the post-polymerization treatments (water boiling, microwave irradiation and water storage). The study included denture base resins, as well as an acrylate for orthodontic appliances impregnated with aesthetic beads. Flexural strength, modulus of elasticity and the deflection were measured immediately after polymerization, after a hot and microwave post-polymerization and after immersion in a water bath at the temperature of 37°C. The applied post-polymerization methods resulted in an increase in flexural strength and modulus of elasticity relative to the initial values for all tested materials. Being aware of the reduction in fracture risk of dental prosthesis after a proposed post-polymerization procedure, it could be used in all clinical situations where there is an increased risk of damage to dentures.
- 1 January 2018
- Published by National Library of Serbia in Hemijska industrija
- Vol. 72 (3) , 129-137
Open AccessEffects of water boiling, microwave, and water bath post-polymerization on mechanical properties of acrylic denture resins
Acrylic restorations in the mouth are exposed to strong occlusal forces. Their mechanical properties depend on the type and method of their polymerization. The aim of this study is a comparative analysis of mechanical properties (flexural strength and modulus of elasticity) of acrylic materials before and after the post-polymerization treatments (water boiling, microwave irradiation and water storage). The study included denture base resins, as well as an acrylate for orthodontic appliances impregnated with aesthetic beads. Flexural strength, modulus of elasticity and the deflection were measured immediately after polymerization, after a hot and microwave post-polymerization and after immersion in a water bath at the temperature of 37°C. The applied post-polymerization methods resulted in an increase in flexural strength and modulus of elasticity relative to the initial values for all tested materials. Being aware of the reduction in fracture risk of dental prosthesis after a proposed post-polymerization procedure, it could be used in all clinical situations where there is an increased risk of damage to dentures.
- Open Access
- 1 January 2017
- Published by National Library of Serbia in Chemical Industry and Chemical Engineering Quarterly
- Vol. 23 (1) , 121-129
The effects of passivation parameters on pitting potential of biomedical stainless steel
Passivation is a chemical process in which the electrochemical condition of passivity is gained on the surface of metal alloys. Biomedical AISI 316LVM stainless steel (SS) can be passivized by means of nitric acid immersion in order to improve a protective oxide layer on the surface and consequently increase corrosion resistance of the SS in the physiological solutions. In this study, multiple regression analysis and artificial neural network (ANN) were employed for mathematical modeling of the AISI 316LVM SS passivation process after immersion in the nitric acid solution. The pitting potential, which represents the mea-sure of pitting corrosion resistance, was chosen as the response, while the passivation parameters were nitric acid concentration, temperature and passivation time. The comparison between experimental results and models predictions showed that only the ANN model provided statistically accurate predictions with a high coefficient of determination and a low mean relative error. Finally, based on the derived ANN equation, the effects of the passivation parameters on pitting potential were examined.
- 1 January 2017
- Published by National Library of Serbia in Chemical Industry and Chemical Engineering Quarterly
- Vol. 23 (1) , 121-129
Open AccessThe effects of passivation parameters on pitting potential of biomedical stainless steel
Passivation is a chemical process in which the electrochemical condition of passivity is gained on the surface of metal alloys. Biomedical AISI 316LVM stainless steel (SS) can be passivized by means of nitric acid immersion in order to improve a protective oxide layer on the surface and consequently increase corrosion resistance of the SS in the physiological solutions. In this study, multiple regression analysis and artificial neural network (ANN) were employed for mathematical modeling of the AISI 316LVM SS passivation process after immersion in the nitric acid solution. The pitting potential, which represents the mea-sure of pitting corrosion resistance, was chosen as the response, while the passivation parameters were nitric acid concentration, temperature and passivation time. The comparison between experimental results and models predictions showed that only the ANN model provided statistically accurate predictions with a high coefficient of determination and a low mean relative error. Finally, based on the derived ANN equation, the effects of the passivation parameters on pitting potential were examined.
- Open Access
- 1 January 2016
- Published by National Library of Serbia in Chemical Industry and Chemical Engineering Quarterly
- Vol. 22 (1) , 95-100
The examination of sensitivity to corrosion of nickel-titanium and stainless steel endodontic instruments in root canal irrigating solutions
The application of irrigating solutions is essential in chemomechanical treatment of tooth root canal. However, chemical and electrochemical aggressiveness of the solutions, which directly act on instruments, may damage their surface. The aim of this study was to investigate the sensitivity of the nickel-titanium (Ni-Ti) and stainless steel endodontic files to corrosive action of the sodium hypochlorite (NaOCl), chlorhexidine gluconate (CHX) and ethylenediamine tetraacetic acid (EDTA). Testing of sensitivity to corrosion of the instruments was performed by dynamic potentiometric method. Measurements were made in 5.25% NaOCl, 0.2% CHX and 17% EDTA. Ni-Ti instruments immersed in 5.25% NaOCl showed the most intensive corrosive changes and the lowest value of pitting potential of 1.1V. Stainless steel instruments immersed in 5.25% NaOCl showed higher value of pitting potential of 1.5V. Stainless steel instruments immersed in 0.2% CHX showed lower corrosive surface changes and higher value of pitting potential of 1.6V, whereas Ni-Ti instruments immersed in 0.2% CHX showed the pitting potential of 1.9V. The corrosion was not observed in both types of instruments after immersion in 17% EDTA. The use of 5.25% NaOCl and 0.2% CHX may cause severe surface corrosion of Ni-Ti and stainless steel endodontic files.
- 1 January 2016
- Published by National Library of Serbia in Chemical Industry and Chemical Engineering Quarterly
- Vol. 22 (1) , 95-100
Open AccessThe examination of sensitivity to corrosion of nickel-titanium and stainless steel endodontic instruments in root canal irrigating solutions
The application of irrigating solutions is essential in chemomechanical treatment of tooth root canal. However, chemical and electrochemical aggressiveness of the solutions, which directly act on instruments, may damage their surface. The aim of this study was to investigate the sensitivity of the nickel-titanium (Ni-Ti) and stainless steel endodontic files to corrosive action of the sodium hypochlorite (NaOCl), chlorhexidine gluconate (CHX) and ethylenediamine tetraacetic acid (EDTA). Testing of sensitivity to corrosion of the instruments was performed by dynamic potentiometric method. Measurements were made in 5.25% NaOCl, 0.2% CHX and 17% EDTA. Ni-Ti instruments immersed in 5.25% NaOCl showed the most intensive corrosive changes and the lowest value of pitting potential of 1.1V. Stainless steel instruments immersed in 5.25% NaOCl showed higher value of pitting potential of 1.5V. Stainless steel instruments immersed in 0.2% CHX showed lower corrosive surface changes and higher value of pitting potential of 1.6V, whereas Ni-Ti instruments immersed in 0.2% CHX showed the pitting potential of 1.9V. The corrosion was not observed in both types of instruments after immersion in 17% EDTA. The use of 5.25% NaOCl and 0.2% CHX may cause severe surface corrosion of Ni-Ti and stainless steel endodontic files.
- Open Access
- 1 January 2016
- Published by National Library of Serbia in Thermal Science
- Vol. 20 (suppl. 5) , 1345-1354
Modeling of cutting temperature in the biomedical stainless steel turning process
Stainless steel is widely used as material in many industries and medicine. As biomedical material, it has been used for making devices, implants as well as tools and equipment in surgery and dentistry. The most of them is processed by turning. Modeling of temperature in the metal cutting process is very important step in understanding and analysis of the metal cutting process. The objective of this study is to develop an artificial neural network model which can be used successfully for accurate prediction of cutting temperature while performing turning of the biomedical stainless steel. Before the modeling, cutting temperature was measured, as one of the significant parameters in turning process, by using the infrared thermal imaging camera. Finally, based on the mathematical model, the effects of the turning parameters on the cutting temperature were examined.
- 1 January 2016
- Published by National Library of Serbia in Thermal Science
- Vol. 20 (suppl. 5) , 1345-1354
Open AccessModeling of cutting temperature in the biomedical stainless steel turning process
Stainless steel is widely used as material in many industries and medicine. As biomedical material, it has been used for making devices, implants as well as tools and equipment in surgery and dentistry. The most of them is processed by turning. Modeling of temperature in the metal cutting process is very important step in understanding and analysis of the metal cutting process. The objective of this study is to develop an artificial neural network model which can be used successfully for accurate prediction of cutting temperature while performing turning of the biomedical stainless steel. Before the modeling, cutting temperature was measured, as one of the significant parameters in turning process, by using the infrared thermal imaging camera. Finally, based on the mathematical model, the effects of the turning parameters on the cutting temperature were examined.
- 20 June 2013
- Published by Springer Nature in Meccanica
- Vol. 48 (10) , 2467-2477
Rheological model optimization using advanced evolutionary computation for the analysis of the influence of recycled rubber on rubber blend dynamical behaviour
- 20 June 2013
- Published by Springer Nature in Meccanica
- Vol. 48 (10) , 2467-2477
Rheological model optimization using advanced evolutionary computation for the analysis of the influence of recycled rubber on rubber blend dynamical behaviour
- Open Access
- 1 January 2012
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Acta stomatologica Naissi
- Vol. 28 (66) , 1171-1179
Strength testing of the relation between plate dentures and materials for making soft liners
Introduction. In clinical practice, the loss of adhesion between the denture base resin and reliner might cause the loss of material softness, water sorption, bacterial colonization and functional failure of the prosthesis. Aim. This study evaluated the effect of immersion on tensile bond strengths of four soft relining materials to a denture base acrylic resin. Material and methods. Four soft lining materials were bonded to heatpolymerized acrylic resin according to the manufacturers' directions. Forty specimens for bond strength test (10 for each liner type) were fabricated. Half of them (control group; n=5) were tested immediately after the fabrication. The other twenty specimens were stored in water at 37°C (test groups; n=5) for one week and then tested. Results. Bond strength of samples right after the fabrication is significantly higher in cases of the samples with silicone elastomer base reliner compared to the samples with soft acrylic base. Bond strength of soft reliners to a denture base resin increases after storing the samples in a water bath for one week at 37°C. Conslusion. Higher increment of tensile bond strength appeared for silicone elastomers in comparison with soft acrylic resins. There were no changes of failure mode except for GC Reline Soft application with the lowest tensile bond strength increment.
- 1 January 2012
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Acta stomatologica Naissi
- Vol. 28 (66) , 1171-1179
Open AccessStrength testing of the relation between plate dentures and materials for making soft liners
Introduction. In clinical practice, the loss of adhesion between the denture base resin and reliner might cause the loss of material softness, water sorption, bacterial colonization and functional failure of the prosthesis. Aim. This study evaluated the effect of immersion on tensile bond strengths of four soft relining materials to a denture base acrylic resin. Material and methods. Four soft lining materials were bonded to heatpolymerized acrylic resin according to the manufacturers' directions. Forty specimens for bond strength test (10 for each liner type) were fabricated. Half of them (control group; n=5) were tested immediately after the fabrication. The other twenty specimens were stored in water at 37°C (test groups; n=5) for one week and then tested. Results. Bond strength of samples right after the fabrication is significantly higher in cases of the samples with silicone elastomer base reliner compared to the samples with soft acrylic base. Bond strength of soft reliners to a denture base resin increases after storing the samples in a water bath for one week at 37°C. Conslusion. Higher increment of tensile bond strength appeared for silicone elastomers in comparison with soft acrylic resins. There were no changes of failure mode except for GC Reline Soft application with the lowest tensile bond strength increment.