SPSayan Patra

Sayan Patra

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sayan Patra has a total of 58 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Design, simulation, and manufacturability of a micro-ion trap incorporating a 3D-printed loading zone for improved hot-ion capture

    by Sayan Patra, Abhinav Parakh, Xiaoxing Xia, Juergen Biener, Hartmut Häffner, Kristin M. Beck

    We leverage recent advances in 3D-printing technology to design, simulate, and fabricate a micro-ion trap with a spatially distinct loading zone for more efficient loading of ions from effusive thermal ovens. The design reduces the Mathieu-q parameter in the loading zone by increasing the rf-null-to-electrode separation r0, thereby potentially facilitating more effective laser cooling of hot ions. This circumvents the temporary thermal instability that arises when the rf potential is reduced during ion loading, a common practice to enable efficient laser cooling of hot ions. Simulations predict that expanding r0 maintains a high trapped ion fraction from a simulated thermal source across a wide range of Mathieu-q parameters. We demonstrate the manufacturability of this design by 3D-printing the rf rails of a four-rod ion trap using the same material and processes used to fabricate a functioning ion trap. We briefly compare hot-ion capture in the three-dimensional design presented here with that in a representative planar trap, illustrating one instance in which the former may be better for loading. The article concludes with an outlook for how this design may be incorporated into a quantum-CCD architecture to enhance ion loading and reduce associated experimental overheads.

  • Open Access

    Endcap-type Paul trap for precision spectroscopy and studies of ion-crystal dynamics

    by Anand Prakash, Akhil Ayyadevara, E. Krishnakumar, M. Ibrahim, K. M. Yatheendran, Subhadeep De, Sayan Patra, S. A. Rangwala

    We present the design and fabrication of an endcap-type Paul trap. The trap is designed for studies with Ca+ and Yb+. The design, fabrication process, and characterization are presented in detail, with a focus on trapping a single compensated ion at the rf node. A custom-built imaging system of NA = 0.14 and magnification of ≈22× performs close to the diffraction limit and resolves multi-ion clusters. Controlled ion loading and characterization of the trap are performed using 40Ca+. The experimentally determined quadrupole coefficient of the trap is ≈0.3, which is very close to the design value. The relative frequency shift along the spectroscopy beam due to excess micromotion is at the level of 3.5 × 10−18 for 40Ca+. Applications of this trap encompass single-ion-based optical frequency standards, tests of fundamental physics, the study of mesoscopic Coulomb clusters, and the controlled interaction of a single ion with co-trapped atoms.

  • Open Access

    Nonequilibrium dynamics of two-level systems directly after cryogenic alternating bias

    by V. Iaia, E.S. Joseph, S. Im, N. Hagopian, S. O’KElley, C. Kim, N. Materise, S. Patra, V. Lordi, M.A. Eriksson, et al.

    Two-level systems (TLSs) are a dominant decoherence mechanism in superconducting qubits, microwave kinetic inductance detectors, and quantum dots. TLSs are tunneling states commonly found in amorphous materials and interfaces, which interact electromechanically, leading to energy loss. Fluctuations in the frequency of the TLSs are a significant problem for qubit operation and force recalibration every few hours. In this study, we probe the effect of alternating bias at cryogenic temperatures on TLSs in a purpose-built LC oscillator. When an alternating bias is applied, the steady-state spectra of the TLSs disappear. Spectroscopy reveals transient behavior, in which the TLS frequency fluctuates on the order of minutes. Thermal cycling above 10 K reverses these effects, restoring the TLS spectrum to its original state. Importantly, the intrinsic loss tangent of the LC oscillator remains unchanged before and after the application of the alternating bias. We propose that the disappearance of the steady-state spectrum is caused by nonequilibrium energy buildup from strain in the oxide film introduced by the pulsed voltage-bias sequence. Understanding this nonequilibrium energy could shed light on TLS fluctuations and reduce the calibration requirements for qubits.

  • Direct detection of the ≈8.4eV internal conversion energy of Th229m embedded in a superconducting nanowire

    by Galen O'NEil, Kjeld Beeks, Eric Hudson, Justin Jeet, David Leibrandt, Marion Mallweger, Sae Woo Nam, Sayan Patra, Gil Porat, Dileep Reddy, et al.


  • Open Access

    Three-body QED test and fifth-force constraint from vibrations and rotations of HD+

    by M. Germann, S. Patra, J.-Ph. Karr, L. Hilico, V. I. Korobov, E. J. Salumbides, K. S. E. Eikema, W. Ubachs, J. C. J. Koelemeij

    We present a parts-per-million test of quantum electrodynamics (QED) in the HD+ molecular hydrogen ion, improving on previous tests based on vibrational and rotational transitions by factors of 76 and 1.4, respectively. The test is performed following a unified statistical approach that also produces improved constraints on physics beyond the standard model. We furthermore show how individual constraints derived from the various degrees of freedom in HD+ and antiprotonic helium can be combined to enhance the sensitivity, thus ruling out “fifth forces” on the Ångstrom scale that are 1011 times weaker than the electromagnetic interaction.


  • Proton-electron mass ratio from laser spectroscopy of HD + at the part-per-trillion level

    by Sayan Patra, M. Germann, J.-Ph. Karr, M. Haidar, L. Hilico, V. I. Korobov, F. M. J. Cozijn, K. S. E. Eikema, W. Ubachs, J. C. J. Koelemeij

    A very precise ratio: The value of the ratio of the masses of the proton and the electron has a bearing on the values of other physical constants. This ratio is known to a very high precision. Patra et al. improved this precision even further by measuring particular frequencies in the rovibrational spectrum of the hydrogen deuteride molecular ion (HD + ) (see the Perspective by Hori). To reach this high precision, the researchers placed the HD + molecules in an ion trap and surrounded them by beryllium ions. The cold beryllium ions then helped cool the HD + molecules, making the HD + spectral lines narrow enough that the proton-electron mass ratio could be extracted by comparison with theoretical predictions. Science , this issue p. 1238 ; see also p. 1160


  • Proton–electron mass ratio from HD + revisited

    by Sayan Patra, Jean-Philippe Karr, Laurent Hilico, Matthias Germann, V I Korobov, Jeroen Koelemeij

    We present a new derivation of the proton–electron mass ratio from the hydrogen molecular ion, HD + . The derivation entails the adjustment of the mass ratio in highly precise theory so as to reproduce accurately measured ro-vibrational frequencies. This work is motivated by recent improvements of the theory, as well as the more accurate value of the electron mass in the recently published CODATA-14 set of fundamental constants, which justifies using it as input data in the adjustment, rather than the proton mass value as done in previous works. This leads to significantly different sensitivity coefficients and, consequently, a different value and larger uncertainty margin of the proton–electron mass ratio as obtained from HD + .


  • Open Access

    Hydrogen molecular ions: new schemes for metrology and fundamental physics tests

    by Jean-Philippe Karr, Sayan Patra, Jeroen C J Koelemeij, Johannes Heinrich, Nicolas Sillitoe, Albane Douillet, Laurent Hilico

    High-accuracy spectroscopy of hydrogen molecular ions has important applications for the metrology of fundamental constants and tests of fundamental theories. Up to now, the experimental resolution has not surpassed the part-per-billion range. We discuss two methods by which it could be improved by a huge factor. Firstly, the feasibility of Doppler-free quasidegenerate two-photon spectroscopy of trapped and sympathetically cooled ensembles of HD + ions is discussed, and it is shown that rovibrational transitions may be detected with a good signal-to-noise ratio. Secondly, the performance of a molecular quantum-logic ion clock based on a single Be +-H + 2 ion pair is analyzed in detail. Such a clock could allow testing the constancy of the proton-to-electron mass ratio at the 10-17 /yr level.