Latest Publications
- 6 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (1) , 160-168
Improving GIS Disconnectors for Future HVDC Applications
The use of standard HVac disconnectors for bus-transfer switching in future HVdc gas-insulated switchgear (GIS) has been demonstrated successfully in past research through simulation and testing. Prolonged arcing times through reignitions caused by high frequency harmonics as well as the proposed extension of GIS disconnector switching cases, however, create an HVdc-specific demand for more advanced disconnector concepts capable of withstanding higher switching stresses and increased recovery voltages. A spring-loaded disconnector designed for use in HVac mixed technology switchgear was found to shorten the time to first current zero through an accelerated increase of the arcing voltage compared to standard disconnectors. Despite its increased switching performance, the reignition characteristics of this fast-acting disconnector were found to largely follow the previously established extinction criterion, which enables further simulation of similar technologies for HVdc applications. To additionally combat the issue of contamination of HVdc GIS by electrode erosion products, a prototype disconnector was improved using permanent magnets to evoke arc rotation. Erosion tests in air have shown an effective reduction of electrode erosion for long arcing times at currents typical for disconnector switching, whereas bus-transfer tests revealed promising enhancements of the reignition behavior.
- 6 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (1) , 160-168
Improving GIS Disconnectors for Future HVDC Applications
The use of standard HVac disconnectors for bus-transfer switching in future HVdc gas-insulated switchgear (GIS) has been demonstrated successfully in past research through simulation and testing. Prolonged arcing times through reignitions caused by high frequency harmonics as well as the proposed extension of GIS disconnector switching cases, however, create an HVdc-specific demand for more advanced disconnector concepts capable of withstanding higher switching stresses and increased recovery voltages. A spring-loaded disconnector designed for use in HVac mixed technology switchgear was found to shorten the time to first current zero through an accelerated increase of the arcing voltage compared to standard disconnectors. Despite its increased switching performance, the reignition characteristics of this fast-acting disconnector were found to largely follow the previously established extinction criterion, which enables further simulation of similar technologies for HVdc applications. To additionally combat the issue of contamination of HVdc GIS by electrode erosion products, a prototype disconnector was improved using permanent magnets to evoke arc rotation. Erosion tests in air have shown an effective reduction of electrode erosion for long arcing times at currents typical for disconnector switching, whereas bus-transfer tests revealed promising enhancements of the reignition behavior.
- 18 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (3) , 1388-1397
Prediction of Bus-Transfer Switching in Future HVdc Substations
Prior research has characterized bus-transfer switching capabilities of disconnectors commonly found in ac gas insulated switchgear by means of a limit performance prediction. A large number of dc bus-transfer tests were conducted on a modified bus-transfer test setup in order to study the applicability of these findings for the use of disconnectors in future HVdc substations. It was found that the ac extinction criterion based solely on the instantaneous recovery voltage and the expected arc voltage at current zero is also valid for dc bus-transfer switching. However, due to the high-frequency harmonics inherent to HVdc power transmission, the process of reaching the initial current zero and the extinction of the switching arc at current zero have been discovered to be independent to a certain degree. For negligible harmonic content of the switching current, arcing times below 20 ms have been predicted for reasonable sizes of substations and realistic dc current magnitudes, which is certainly within the capabilities of existing ac disconnectors. The previously devised limit performance prediction can be applied to gauge influences of different harmonic current contents and small modifications to the disconnector in simulation by applying the reignition criterion at the initial and all subsequent current zeros. Ultimately, however, exact knowledge of frequency and magnitude of the harmonic currents is needed in order to perform accurate predictions.
- 18 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (3) , 1388-1397
Prediction of Bus-Transfer Switching in Future HVdc Substations
Prior research has characterized bus-transfer switching capabilities of disconnectors commonly found in ac gas insulated switchgear by means of a limit performance prediction. A large number of dc bus-transfer tests were conducted on a modified bus-transfer test setup in order to study the applicability of these findings for the use of disconnectors in future HVdc substations. It was found that the ac extinction criterion based solely on the instantaneous recovery voltage and the expected arc voltage at current zero is also valid for dc bus-transfer switching. However, due to the high-frequency harmonics inherent to HVdc power transmission, the process of reaching the initial current zero and the extinction of the switching arc at current zero have been discovered to be independent to a certain degree. For negligible harmonic content of the switching current, arcing times below 20 ms have been predicted for reasonable sizes of substations and realistic dc current magnitudes, which is certainly within the capabilities of existing ac disconnectors. The previously devised limit performance prediction can be applied to gauge influences of different harmonic current contents and small modifications to the disconnector in simulation by applying the reignition criterion at the initial and all subsequent current zeros. Ultimately, however, exact knowledge of frequency and magnitude of the harmonic currents is needed in order to perform accurate predictions.
- 14 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 32 (5) , 2210-2217
Novel Method for Predicting Limit Performance of Bus-Transfer Switching by Disconnectors
In order to accurately predict the performance of disconnectors conducting bus-transfer switching in gas insulated substations, the influencing factors of the switching process itself as well as the reignition characteristics need to be analyzed. For this, an LC-oscillating ac current source in combination with a nonstandardized full bus-transfer loop was built. Based on experiment data from a total of 347 reignitions and 570 extinctions, the reignition characteristic of the disconnector at current zero was investigated. Thereby, the derivation of a reignition criterion depending exclusively on the prediction of the instantaneous recovery voltage and the prospective arc voltage was possible. Using this criterion, time-dependent simulations of the bus-transfer process can be made to predict the performance of disconnectors for a wide variety of scenarios such as worst case bus-transfer current for varying circuit parameters and ratings. This minimizes the need for extensive testing during substation planning or disconnector development.
- 14 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 32 (5) , 2210-2217
Novel Method for Predicting Limit Performance of Bus-Transfer Switching by Disconnectors
In order to accurately predict the performance of disconnectors conducting bus-transfer switching in gas insulated substations, the influencing factors of the switching process itself as well as the reignition characteristics need to be analyzed. For this, an LC-oscillating ac current source in combination with a nonstandardized full bus-transfer loop was built. Based on experiment data from a total of 347 reignitions and 570 extinctions, the reignition characteristic of the disconnector at current zero was investigated. Thereby, the derivation of a reignition criterion depending exclusively on the prediction of the instantaneous recovery voltage and the prospective arc voltage was possible. Using this criterion, time-dependent simulations of the bus-transfer process can be made to predict the performance of disconnectors for a wide variety of scenarios such as worst case bus-transfer current for varying circuit parameters and ratings. This minimizes the need for extensive testing during substation planning or disconnector development.