Ueli Straumann
Research Subjects
Ueli Straumann has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Christian Michael Franck
Institute for Power Systems and High Voltage Technology, ETH Zürich, Physikstrasse 3, 8092 Zürich, Switzerland
2 shared publications - Andreas Ritter
Power Systems and High Laboratories (EEH), ETH Zurich, Zurich, Switzerland
1 shared publication - Kunal Soni
Hitachi Energy Research, Segelhofstrasse 1A, Baden-Dättwil 5045, Switzerland
1 shared publication Lise Donzel
Hitachi Energy Research, Hitachi Energy Ltd, Baden-Dttwil, Switzerland
1 shared publicationMartin Seeger
Hitachi Energy Research, Hitachi Energy Ltd, Baden-Dttwil, Switzerland
1 shared publication- Martin Seeger
Hitachi Energy Research, Segelhofstrasse 1A, Baden-Dättwil 5045, Switzerland
1 shared publication
Latest Publications
- 12 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Decomposition of SF6-free Insulation Gases Due to Partial Discharges
Suitable SF₆-free insulation gases, such as mixtures with C4-fluoronitrile, should not only perform well regarding insulation and arc quenching, but also fulfill other requirements, such as stability against decomposition. One source for decomposing gases comes from partial discharge activity, which may be present in technical applications due to defects, such as free conductive particles. In this paper, an experiment series is presented, which subjects insulation gases to corona discharges. Different gas mixtures at different pressures were exposed to high voltage DC corona discharges for several weeks to determine the charge-based C₄F₇N decomposition by-product formation rates. The experiment is first assessed theoretically regarding expected decomposition rates and ion currents. Then measurement results are presented, covering decomposition and decomposition by-product formation rates. The decomposition rate in (mol/C) can be used to estimate the impact of partial discharge activity on the C₄F₇N concentration for real high voltage equipment contaminated with particles. Even for pessimistic scenarios, the C₄F₇N depletion over a 40-years’ time horizon is marginal and does not affect the performance of the switchgear.
- 12 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Decomposition of SF6-free Insulation Gases Due to Partial Discharges
Suitable SF₆-free insulation gases, such as mixtures with C4-fluoronitrile, should not only perform well regarding insulation and arc quenching, but also fulfill other requirements, such as stability against decomposition. One source for decomposing gases comes from partial discharge activity, which may be present in technical applications due to defects, such as free conductive particles. In this paper, an experiment series is presented, which subjects insulation gases to corona discharges. Different gas mixtures at different pressures were exposed to high voltage DC corona discharges for several weeks to determine the charge-based C₄F₇N decomposition by-product formation rates. The experiment is first assessed theoretically regarding expected decomposition rates and ion currents. Then measurement results are presented, covering decomposition and decomposition by-product formation rates. The decomposition rate in (mol/C) can be used to estimate the impact of partial discharge activity on the C₄F₇N concentration for real high voltage equipment contaminated with particles. Even for pessimistic scenarios, the C₄F₇N depletion over a 40-years’ time horizon is marginal and does not affect the performance of the switchgear.
- 30 October 2025
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 58 (44) , 445201
Streamer parameters in CO 2 /O 2 /C 4 F 7 N gas mixture for application in high voltage switchgear
Gas mixture with CO 2 , O 2 and 3.5% C 4 F 7 N presents one of the most promising alternatives to SF 6 in high-voltage sub-transmission and transmission networks. It offers insulation properties similar to SF 6, while reducing the Global Warming Potential by a factor of 100 on the 100 year horizon. The dielectric properties of this gas mixture have, therefore, attracted considerable interest in recent years. The properties of streamer discharges in the CO 2 /O 2 /C 4 F 7 N gas mixture with 3.5% C 4 F 7 N are important in this regard since they determine the discharge inception and propagation, as well as the potential transition to a leader. In this study, we investigate the streamer inception and propagation at ambient temperature in the pressure range of 0.01–0.1 MPa, for both positive and negative polarities. Streamer parameters, i.e. the stability field, length and radius were obtained in uniform as well as strongly non-uniform background fields. These parameters enhance our understanding of streamer inception, propagation and streamer-to-leader transition in the CO 2 /O 2 /C 4 F 7 N gas mixture.
- 30 October 2025
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 58 (44) , 445201
Streamer parameters in CO 2 /O 2 /C 4 F 7 N gas mixture for application in high voltage switchgear
Gas mixture with CO 2 , O 2 and 3.5% C 4 F 7 N presents one of the most promising alternatives to SF 6 in high-voltage sub-transmission and transmission networks. It offers insulation properties similar to SF 6, while reducing the Global Warming Potential by a factor of 100 on the 100 year horizon. The dielectric properties of this gas mixture have, therefore, attracted considerable interest in recent years. The properties of streamer discharges in the CO 2 /O 2 /C 4 F 7 N gas mixture with 3.5% C 4 F 7 N are important in this regard since they determine the discharge inception and propagation, as well as the potential transition to a leader. In this study, we investigate the streamer inception and propagation at ambient temperature in the pressure range of 0.01–0.1 MPa, for both positive and negative polarities. Streamer parameters, i.e. the stability field, length and radius were obtained in uniform as well as strongly non-uniform background fields. These parameters enhance our understanding of streamer inception, propagation and streamer-to-leader transition in the CO 2 /O 2 /C 4 F 7 N gas mixture.
- 6 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (1) , 160-168
Improving GIS Disconnectors for Future HVDC Applications
The use of standard HVac disconnectors for bus-transfer switching in future HVdc gas-insulated switchgear (GIS) has been demonstrated successfully in past research through simulation and testing. Prolonged arcing times through reignitions caused by high frequency harmonics as well as the proposed extension of GIS disconnector switching cases, however, create an HVdc-specific demand for more advanced disconnector concepts capable of withstanding higher switching stresses and increased recovery voltages. A spring-loaded disconnector designed for use in HVac mixed technology switchgear was found to shorten the time to first current zero through an accelerated increase of the arcing voltage compared to standard disconnectors. Despite its increased switching performance, the reignition characteristics of this fast-acting disconnector were found to largely follow the previously established extinction criterion, which enables further simulation of similar technologies for HVdc applications. To additionally combat the issue of contamination of HVdc GIS by electrode erosion products, a prototype disconnector was improved using permanent magnets to evoke arc rotation. Erosion tests in air have shown an effective reduction of electrode erosion for long arcing times at currents typical for disconnector switching, whereas bus-transfer tests revealed promising enhancements of the reignition behavior.
- 6 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (1) , 160-168
Improving GIS Disconnectors for Future HVDC Applications
The use of standard HVac disconnectors for bus-transfer switching in future HVdc gas-insulated switchgear (GIS) has been demonstrated successfully in past research through simulation and testing. Prolonged arcing times through reignitions caused by high frequency harmonics as well as the proposed extension of GIS disconnector switching cases, however, create an HVdc-specific demand for more advanced disconnector concepts capable of withstanding higher switching stresses and increased recovery voltages. A spring-loaded disconnector designed for use in HVac mixed technology switchgear was found to shorten the time to first current zero through an accelerated increase of the arcing voltage compared to standard disconnectors. Despite its increased switching performance, the reignition characteristics of this fast-acting disconnector were found to largely follow the previously established extinction criterion, which enables further simulation of similar technologies for HVdc applications. To additionally combat the issue of contamination of HVdc GIS by electrode erosion products, a prototype disconnector was improved using permanent magnets to evoke arc rotation. Erosion tests in air have shown an effective reduction of electrode erosion for long arcing times at currents typical for disconnector switching, whereas bus-transfer tests revealed promising enhancements of the reignition behavior.
- 20 February 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 21 (1) , 352-359
Role of ion sources for spacer charging in SF6 gas insulated HVDC systems
Stationary DC electric fields are determined by the resistivity distribution of the insulation materials. In the presence of interfaces between different insulation materials, charge accumulation at these boundary layers may have a significant influence on the electric field distribution and with it on the breakdown strength of the arrangement. In many previous works, surface charging of model spacers was investigated. However, the ion flow problem to properly account for the electric conduction in the gas has not yet been solved. The role of different ion sources and the behavior of the resulting ion currents in the gas phase on the charge accumulation process have to be investigated in more detail. In this paper, the transient charge accumulation process on a PTFE spacer surface with a focus on charges originating from the gas phase is investigated experimentally and by simulations. These charges are produced by natural radiation. The transition of the ohmic conduction regime in the gas to a saturated ion current with increasing voltage is analyzed. Furthermore, the importance of additional charge sources like partial discharges and field emission from the electrodes is highlighted. The experimental results indicate that additional charges are generated already at voltage levels significantly below the measured PD inception voltage. These charges originate from micro discharges on the electrodes and have to be taken into account when designing HVDC GIS applications.
- 20 February 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 21 (1) , 352-359
Role of ion sources for spacer charging in SF6 gas insulated HVDC systems
Stationary DC electric fields are determined by the resistivity distribution of the insulation materials. In the presence of interfaces between different insulation materials, charge accumulation at these boundary layers may have a significant influence on the electric field distribution and with it on the breakdown strength of the arrangement. In many previous works, surface charging of model spacers was investigated. However, the ion flow problem to properly account for the electric conduction in the gas has not yet been solved. The role of different ion sources and the behavior of the resulting ion currents in the gas phase on the charge accumulation process have to be investigated in more detail. In this paper, the transient charge accumulation process on a PTFE spacer surface with a focus on charges originating from the gas phase is investigated experimentally and by simulations. These charges are produced by natural radiation. The transition of the ohmic conduction regime in the gas to a saturated ion current with increasing voltage is analyzed. Furthermore, the importance of additional charge sources like partial discharges and field emission from the electrodes is highlighted. The experimental results indicate that additional charges are generated already at voltage levels significantly below the measured PD inception voltage. These charges originate from micro discharges on the electrodes and have to be taken into account when designing HVDC GIS applications.