SISelvarasan Iniyan

Selvarasan Iniyan

*This is an algorithmically generated author record based on publicly available information.

Selvarasan Iniyan has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Path of carbon dioxide capture technologies: An overview

    by Ashokkumar Shyam, Kalilur Rahiman Arshad Ahmed, Jeyaraman Prasanna Naveen Kumar, Selvarasan Iniyan, Ranko Goic


  • Experimental investigation on a solar parabolic trough receiver tube enhanced by toroidal rings

    by Kalilur Rahiman Arshad Ahmed, J Prasanna Naveen Kumar, Ashokkumar Shyam, Elumalai Natarajan, Selvarasan Iniyan, Ranko Goic

    The experimental investigation with the incorporation of toroidal rings in an absorber tube of a lab-scale solar parabolic trough collector is carried out in the present study. Five different cases of the absorber tube including the reference smooth absorber tube and the absorber incorporated with 2, 4, 6 and 8 mm thick toroidal rings are investigated. The influence of performance parameters like thermal efficiency, heat loss, thermal enhancement index and so on with different absorber tube configurations are evaluated, compared and illustrated to determine the best case. The outcomes indicate that the absorber tube with 6 and 8 mm thick toroidal rings are the best cases, with the 8 mm case exhibiting a higher exergy efficiency in the range of 38.57%-24.64%. The thermal efficiency for the best absorber cases is found to be 69.43% and 70.34% with the pressure drop being 1.67 and 0.93 kPa, respectively. Also, the cost of heat gain produced with the efficient absorber case is seen to be ₹ 3.43/kWh (US$ 0.045/kWh and € 0.040/kWh), which is nearly 15.51% lower than the reference case. Hence, the incorporation of toroidal rings could be effectively utilized in a large-scale solar thermal system for improved thermal performance.


  • Optical performance enhancement in a solar parabolic trough collector with optimized secondary optics

    by Ashokkumar Shyam, Selvarasan Iniyan, Ranko Goic

    The maximum concentration ratio of the commercial parabolic trough collectors is limited to 42% of the theoretical limit of concentration. Recently, the secondary flat reflector geometry has been proposed to increase the concentration ratio of parabolic trough close to the theoretical limit. Using those secondary reflector geometry as a starting point, we optimize the reflector geometry for commercial LS-3 parabolic trough with additional secondary optics named flat linear refracted Fresnel lens and evaluate the performance using Monte-Carlo ray tracing method. In this paper, theoretical and optical performance analyses of the proposed system have been investigated. The analysis of parabolic trough with additional secondary optics revealed a potential reduction in shadow area of the secondary reflector on the absorber tube and the primary mirror to 0%. It is found that the new concentration ratio of 48.24 was observed for the proposed system, which is nearly 84.19% higher than the commercial LS-3 collector.


  • Experimental analysis of heat loss of a non – evacuated parabolic trough collector receiver subjected to uniform and non-uniform wall heat flux condition

    by Manikandan G.K., Selvarasan Iniyan, Ranko Goic

    The parameters that largely influence the design and performance of a parabolic trough collector system for delivering process heat are optical efficiency, incidence angle modifier, solar irradiation data, and receiver heat loss. The heat loss and optical properties of a receiver greatly influence the overall efficiency of the solar thermal system. This paper focuses the attention on the experimental investigation of heat loss associated with a non-evacuated receiver subjected to i). Uniform wall heat flux (UWHF) and ii). Non – uniform wall heat flux (NUWHF) boundary condition. A series of heat-loss measurements are carried out in the novel test stand capable of emulating both the boundary conditions, on the indigenous non – evacuated receiver developed for moderate temperature process heat applications. A comparative analysis of natural and forced convection heat loss associated with the bare and glass-covered receiver is performed. The results show that the non – uniform wall heat flux boundary condition has a decisive influence over the forced convection heat loss, especially at higher wind velocities. The work concludes that i) the surface temperature of the receiver associated with natural convection heat loss and subjected to NUWHF boundary condition is1.5– 5% higher than the receiver subjected to UWHF boundary condition. ii) In forced convection mode of heat loss the surface temperature of the receiver is 4–13% higher than the receiver subjected to UWHF. Thus, a more realistic characterization of the thermal behaviour of a non-evacuated receiver for moderate temperature process heat application is possible only by investigating the receiver subjected to non – uniform heat flux distribution. Such a characterization of the receiver will considerably influence the aperture area and thus the cost of the collector to deliver process heat.


  • Experimental investigation of ridge concentrator PV-based solar water pumping system for small-scale applications

    by Kalaiselvan Narasimman, Selvarasan Iniyan, Ranko Goic

    Solar photovoltaic (PV) pumping systems were found to be used in many countries, but at present, they are expensive due to the high cost of materials. The cost can be reduced by using some optical concentrators such as linear mirrors, lenses, etc. Based on the economy and reliability, the concentrator PV pumping system is suitable for remote and small-scale water pumping applications. In this paper, a single axis monthly tracking ridge concentrator has been proposed as an alternative to reduce the final cost of the pumping system. Certain optical parameters, such as concentration ratio (C), tilt angle (Փ), and trough angle (Ψ), would provide more illumination on the PV region, where the panels are located. In this system, the entire tracking can be reduced into a single axis monthly tilt (Փ) according to the latitude and the declination of the location. The usage of ridge wall with optimum trough angle causes an increase in the receiver irradiation (Irec) and thus the gain in terms of water volume while pumping. The optimum trough angle was simulated by TracePro model and the shading analysis and characteristic curves were obtained using the PVSyst software. In this work, the entire system was experimentally tested using the maximum power extraction system controller fed inverter and battery-coupled configuration mode. The gains in power and pumped water volume with various tilting, with and without concentrator against fixed system with various solar radiations, were absorbed. As a result, the concentration ratio on PV module at 60° trough angle increased the optical efficiency and produced better water volume during the peak noon condition. The results indicated the V–I characteristics on the ridge concentrator PV surfaces with optimum tilt as significantly greater than those on normal module. There was an increase in electrical power gain up to 10.2%, 19.03%, 23.10%, and 47.89% for single X, single X with tilt, double X, and double X with tilt, respectively, compared with a fixed panel. The ridge concentrator with double X reflector coupled with battery had less charging of 6.8 h compared to the reference panel. This mode produces maximum flow rate of 37.5 L/min at peak isolation condition.


  • Open Access

    Short-Term Forecasting of Total Energy Consumption for India-A Black Box Based Approach

    by Habeebur Rahman, Iniyan Selvarasan, Jahitha Begum A

    Continual energy availability is one of the prime inputs requisite for the persistent growth of any country. This becomes even more important for a country like India, which is one of the rapidly developing economies. Therefore electrical energy’s short-term demand forecasting is an essential step in the process of energy planning. The intent of this article is to predict the Total Electricity Consumption (TEC) in industry, agriculture, domestic, commercial, traction railways and other sectors of India for 2030. The methodology includes the familiar black-box approaches for forecasting namely multiple linear regression (MLR), simple regression model (SRM) along with correlation, exponential smoothing, Holt’s, Brown’s and expert model with the input variables population, GDP and GDP per capita using the software used are IBM SPSS Statistics 20 and Microsoft Excel 1997–2003 Worksheet. The input factors namely GDP, population and GDP per capita were taken into consideration. Analyses were also carried out to find the important variables influencing the energy consumption pattern. Several models such as Brown’s model, Holt’s model, Expert model and damped trend model were analysed. The TEC for the years 2019, 2024 and 2030 were forecasted to be 1,162,453 MW, 1,442,410 MW and 1,778,358 MW respectively. When compared with Population, GDP per capita, it is concluded that GDP foresees TEC better. The forecasting of total electricity consumption for the year 2030–2031 for India is found to be 1834349 MW. Therefore energy planning of a country relies heavily upon precise proper demand forecasting. Precise forecasting is one of the major challenges to manage in the energy sector of any nation. Moreover forecasts are important for the effective formulation of energy laws and policies in order to conserve the natural resources, protect the ecosystem, promote the nation’s economy and protect the health and safety of the society.