Tim Jerman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tim Jerman has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Boštjan Likar
Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia
2 shared publications - Franjo Pernuš
Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia
2 shared publications - Žiga Špiclin
Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia
2 shared publications - Aichi Chien
From the Department of Radiology (A.C., G.C., N.S.), David Geffen School of Medicine at UCLA, Los Angeles, California
1 shared publication - Alfiia Galimzianova
Department of Radiology, Stanford University School of Medicine, Stanford, CA, USA
1 shared publication Bostjan Likar
University of Ljubljana, Faculty of Electrical Engineering, Ljubljana, Slovenia
1 shared publication
Latest Publications
- 24 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (2) , 577-587
Automated Cutting Plane Positioning for Intracranial Aneurysm Quantification
Objective: Aneurysm rupture risk can be assessed by its morphologic features extracted from angiographic images. Feature extraction entails aneurysm isolation, typically by manually positioning a cutting plane (MCP). To eliminate intra- and inter-rater variabilities we propose automatic cutting plane (ACP) positioning based on the analysis of vascular surface mesh. Methods: Innovative Hough-like and multi-hypothesis based detection of aneurysm center, parent vessel inlets and centerlines were proposed. These were used for initialization and iterative ACP positioning by geometry-inspired cost function optimization. For validation and baseline comparison we tested MCP and manual neck curve based isolation. Isolated aneurysm morphology was characterized by size, dome height, aspect ratio and nonsphericity index. Results: Methods were applied to 55 intracranial saccular aneurysms from two sites, involving 3D DSA, CTA and MRA modalities. Isolation based on ACP resulted in small average inter-curve distances (AICDs), compared to those obtained by MCP. One case had AICD higher than 1.0 mm, while 90% of cases had AICD < 0.5 mm. Intra- and inter-rater AICD variability of manual neck curves was higher compared to MCP, validating its robustness for clinical purposes. Conclusion: The ACP method achieved high accuracy and reliability of aneurysm isolation, also confirmed by expert visual analysis. So extracted morphologic features were in good agreement with MCP-based ones therefore ACP has great potential for aneurysm quantification in clinical applications. Significance: Novel method is angiographic modality agnostic, delivers repeatable isolation important in follow-up aneurysm assessment, its performance is comparable to MCP, re-evaluation is fast and simple.
- 24 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (2) , 577-587
Automated Cutting Plane Positioning for Intracranial Aneurysm Quantification
Objective: Aneurysm rupture risk can be assessed by its morphologic features extracted from angiographic images. Feature extraction entails aneurysm isolation, typically by manually positioning a cutting plane (MCP). To eliminate intra- and inter-rater variabilities we propose automatic cutting plane (ACP) positioning based on the analysis of vascular surface mesh. Methods: Innovative Hough-like and multi-hypothesis based detection of aneurysm center, parent vessel inlets and centerlines were proposed. These were used for initialization and iterative ACP positioning by geometry-inspired cost function optimization. For validation and baseline comparison we tested MCP and manual neck curve based isolation. Isolated aneurysm morphology was characterized by size, dome height, aspect ratio and nonsphericity index. Results: Methods were applied to 55 intracranial saccular aneurysms from two sites, involving 3D DSA, CTA and MRA modalities. Isolation based on ACP resulted in small average inter-curve distances (AICDs), compared to those obtained by MCP. One case had AICD higher than 1.0 mm, while 90% of cases had AICD < 0.5 mm. Intra- and inter-rater AICD variability of manual neck curves was higher compared to MCP, validating its robustness for clinical purposes. Conclusion: The ACP method achieved high accuracy and reliability of aneurysm isolation, also confirmed by expert visual analysis. So extracted morphologic features were in good agreement with MCP-based ones therefore ACP has great potential for aneurysm quantification in clinical applications. Significance: Novel method is angiographic modality agnostic, delivers repeatable isolation important in follow-up aneurysm assessment, its performance is comparable to MCP, re-evaluation is fast and simple.
- Top Cited Papers
- 4 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 35 (9) , 2107-2118
Enhancement of Vascular Structures in3D and 2D Angiographic Images
A number of imaging techniques are being used for diagnosis and treatment of vascular pathologies like stenoses, aneurysms, embolisms, malformations and remodelings, which may affect a wide range of anatomical sites. For computer-aided detection and highlighting of potential sites of pathology or to improve visualization and segmentation, angiographic images are often enhanced by Hessian based filters. These filters aim to indicate elongated and/or rounded structures by an enhancement function based on Hessian eigenvalues. However, established enhancement functions generally produce a response, which exhibits deficiencies such as poor and non-uniform response for vessels of different sizes and varying contrast, at bifurcations and aneurysms. This may compromise subsequent analysis of the enhanced images. This paper has three important contributions: i) reviews several established enhancement functions and elaborates their deficiencies, ii) proposes a novel enhancement function, which overcomes the deficiencies of the established functions, and iii) quantitatively evaluates and compares the novel and the established enhancement functions on clinical image datasets of the lung, cerebral and fundus vasculatures.
- 4 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 35 (9) , 2107-2118
Top Cited PapersEnhancement of Vascular Structures in3D and 2D Angiographic Images
A number of imaging techniques are being used for diagnosis and treatment of vascular pathologies like stenoses, aneurysms, embolisms, malformations and remodelings, which may affect a wide range of anatomical sites. For computer-aided detection and highlighting of potential sites of pathology or to improve visualization and segmentation, angiographic images are often enhanced by Hessian based filters. These filters aim to indicate elongated and/or rounded structures by an enhancement function based on Hessian eigenvalues. However, established enhancement functions generally produce a response, which exhibits deficiencies such as poor and non-uniform response for vessels of different sizes and varying contrast, at bifurcations and aneurysms. This may compromise subsequent analysis of the enhanced images. This paper has three important contributions: i) reviews several established enhancement functions and elaborates their deficiencies, ii) proposes a novel enhancement function, which overcomes the deficiencies of the established functions, and iii) quantitatively evaluates and compares the novel and the established enhancement functions on clinical image datasets of the lung, cerebral and fundus vasculatures.
- 1 January 2016
- Published by Springer Nature
- p. 45-56
Combining Unsupervised and Supervised Methods for Lesion Segmentation
- 1 January 2016
- Published by Springer Nature
- p. 45-56
Combining Unsupervised and Supervised Methods for Lesion Segmentation
- 20 November 2015
- Published by Springer Nature
- p. 3-10
Computer-Aided Detection and Quantification of Intracranial Aneurysms
- 20 November 2015
- Published by Springer Nature
- p. 3-10
Computer-Aided Detection and Quantification of Intracranial Aneurysms