EMElnaz Moslehifard

Elnaz Moslehifard

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Elnaz Moslehifard has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Electrodeposition of Cu nanoparticles on TiO 2 nanotubes for enhanced bactericidal effect against Escherichia coli

    by Naser Edraki, Elnaz Moslehifard, AmirAli Farmani, Ali Baradar Khoshfetrat, Farzad Nasirpouri

    Effective and environmentally friendly disinfection methods are crucial for preventing infections and deaths. In this work, we produced anodic TiO 2 nanotubes (TNTs) composited with copper nanoparticles via electrodeposition.


  • Open Access

    In vitro effect of zirconia type on shear bond strength to feldspathic porcelain and wear of the opposing teeth

    by Amirhossein Rafiei, Vahid Fakhrzadeh, Elnaz Moslehifard, Ghazal Ranjbar

    Background. Multilayer zirconia has more optical and aesthetic features than regular zirconia. Therefore, its mechanical properties should be compared with monochromatic zirconia. Among the mechanical characteristics that can be checked are the wear of the opposite tooth and the bond to the porcelain. This study assessed the effect of zirconia type (multilayer versus monochromatic) on the shear bond strength (SBS) to feldspathic porcelain and the wear of the opposing teeth. Methods. The present in vitro study was conducted in two phases. In the first phase, 15 multilayer and 15 monochromatic zirconia blocks measuring 10×5×5 mm were designed, milled, sintered, veneered with porcelain, and underwent thermocycling. Their SBS was then measured in a universal testing machine. In the second phase, 15 multilayer and 15 monochromatic zirconia blocks were placed in a chewing simulator, and 30 sound premolars served as antagonistic teeth. The magnitude of wear of the buccal cusp of premolars was quantified from a 4-mm reference point after 100000 cycles. Data were analyzed by independent t test (α=0.05). Results. The mean SBS of monochromatic zirconia to porcelain (24.49±3.58 MP) was slightly higher than that of multilayer zirconia (22.98±2.98 MP), but the difference was not significant (P>0.05). The mean wear of the opposing teeth was also slightly higher in the monochromatic group (284.1±66.53 µm) than in the multilayer group (263.2±58.69 µm), but this difference was not significant either (P>0.05). Conclusion. Monochromatic and multilayer zirconia showed comparable SBS to feldspathic porcelain and caused comparable wear of the opposing teeth in vitro. Thus, multilayer zirconia may serve as an alternative to monochromatic zirconia.

  • In vitro effect of zirconia type on marginal and internal fit of a three-unit bridge.

    by Vahid Fakhrzadeh, Amirhossein Rafiei, Ghazal Ranjbar, Elnaz Moslehifard

  • Effect of Surface Glaze Treatment and Mechanical Polishing on the Color Stability of Two Types of Cad/Cam Ceramics

    by Sadaf Ghazaee, Elnaz Moslehifard, Tahereh Ghaffari, Farzad Nasirpouri


  • Open Access

    Evaluation of microhardness in two types of denture bases after using sodium hypochlorite and NatureDent disinfecting agents

    by Elnaz Moslehifard, Tahereh Ghaffari, Khosro Zarei, Mahsa Karimoghli

    Background. Chemical agents, in combination with mechanical methods, play an important role in reducing microbial plaque on denture surfaces. However, these methods might change the mechanical behavior of acrylic resins, including microhardness and surface roughness. This in vitro study investigated the effect of two disinfectants, i.e., water and sodium hypochlorite, on the microhardness of conventional heat-cured and TiO2 nanoparticle-reinforced acrylic resins. Methods. Sixty acrylic resin specimens were divided into two groups, and the samples in each group were randomly assigned to three subgroups (n=10). Heat-cured specimens and 1 wt% TiO2 acrylic resin were prepared and immersed in three solutions: water, a solution prepared with NatureDent pills, and 1% sodium hypochlorite for 30, 60, and 90 days. Microhardness tests were performed on each sample at each immersion stage. The data were analyzed using descriptive statistical methods, three-way and one-way ANOVA, repeated-measures t test, and Tukey HSD tests using SPSS 17. P values<0.05 were considered significant. Results. All three independent parameters, including resin, solution, and time, significantly affected microhardness (P<0.05). The microhardness of both specimen types, i.e., conventional heat-cured and TiO2 nanoparticle-reinforced acrylic resins, immersed for 30, 60, and 90 days, was the highest and lowest in water and hypochlorite solutions, respectively. Regarding 90 days, the microhardness values of conventional heat-cured and TiO2 nanoparticle-reinforced acrylic resins were 17.050±0.094 and 19.953±0.053 in water, 15.675±0.069 and 18.965±0.037 in hypochlorite, and 16.713±0.122 and 19.39±20.113 in NatureDent solutions, respectively. Conclusion. Disinfecting two types of acrylic resin specimens decreased their microhardness as a function of immersion time for up to 90 days in the three solutions. However, the magnitude of hardness lost was less for TiO2 nanoparticles-reinforced acrylic resin.


  • Open Access

    Comparison of Conventional Pressure‐packed and Injection Molding Processing Methods for an Acrylic Resin Denture based on Microhardness, Surface Roughness, and Water Sorption

    by Elnaz Moslehifard, Tahereh Ghaffari, Hamidreza Abolghasemi, Solmaz Maleki Dizaj

    Polymethyl methacrylate (PMMA) is a widely used material in prosthetics and is used to fabricate denture bases. The main disadvantage of this material is its polymerization shrinkage which causes clinical problems during use. The present study aimed to investigate and compare the microhardness, surface roughness, and water sorption of a commercial acrylic resin denture, which were processed by two different methods including conventional and pressure‐packed injection molding techniques. A total of 60 polymethyl methacrylate samples were prepared in two groups: conventional acrylic resin (vertex) for the compression molding method and injection acrylic resin (vertex) for the injection molding method (10 samples of each material per test). The microhardness test was performed using a Vickers microhardness test device, the surface roughness test was performed by using a profilometer, and the water sorption test was performed using a digital scale. Data were analyzed using an independent sample t‐test with Statistical Package for the Social Sciences (SPSS), version 17. The significant level was considered to be 0.05. According to the results, there was a significant difference between microhardness, surface roughness, and water sorption of the samples in the two groups. The results of the independent t‐test showed that the microhardness of injection vertex acrylic resin samples was significantly higher than that of conventional pressure‐packed vertex acrylic resin samples (P valueP value <0.05). According to the obtained results, denture fabrication by the injection molding method can improve the quality and durability of dentures due to the increased microhardness, the decreased surface roughness, and the decreased water absorption of the denture base compared with the conventional method.


  • Open Access

    Evaluation of Surface Roughness of a Ni-Cr Alloy Treated With the Nd/YAG Laser and the Sandblast Technique

    by Elnaz Moslehifard, Mir Mahdi Seyyedashrafi, Nasim Khosronejad

    Introduction: This study was to assess the effect of various output parameters of laser treatment on roughening the surface of a commercial nickel-chromium (Ni-Cr) alloy as compared to the sandblasting technique. Materials and Methods: Ninety-six disk-shaped (5 mm diameter and 2 mm thickness) specimens in total were made of a nickel-chromium alloy by using the lost-wax technique. Air-abrasion surface treatment was used for sixteen specimens. Specimens were divided into six groups; one of them was sandblasted and the rest were irradiated by different Nd:YAG laser output parameters as follows: Group A: energy: 122 mJ, frequency: 20 Hz, irradiation duration: 20 seconds, spot size: 1.5 mm; Group B: energy: 122 mJ, frequency: 20 Hz, irradiation duration: 20 seconds, spot size: 3.5 mm; Group C: energy: 122 mJ, frequency: 10 Hz, irradiation duration: 20 seconds, spot size: 3.5 mm; Group D: energy: 102 mJ, frequency: 10 Hz, irradiation duration: 20 seconds, spot size: 3 mm; Group E: energy: 102 mJ, frequency: 20 Hz, irradiation duration: 20 seconds, spot size: 3 mm. The surface roughness of all surface-treated specimens was evaluated by using a profilometer, and their average roughness (Ra) was calculated. The average value of each group was analyzed by t test and one-way ANOVA (SPSS 17). Results: Significant differences (P<0.05) were observed between the study groups. The highest Ra was achieved for the sandblasted group. The Ra value in group C was the highest value among the laser-etched groups. Conclusion: Based on the results, Nd:YAG laser irradiation increases surface roughness, but it is not as efficient as the sandblasting method as a gold standard.


  • Open Access

    Effect of chemical passivation on corrosion behavior and ion release of a commercial chromium-cobalt alloy

    by Elnaz Moslehifard, Tahereh Ghaffari, Samineh Mohammadian-Navid, Mina Ghafari-Nia, Amirali Farmani, Farzad Nasirpouri

    Background. Corrosion resistance and ion release of alloys play a crucial role in biomedical applications. The present study aimed to investigate an increase in corrosion resistance and reduction in ion release in a commercial Co-Cr-Mo alloy by the chemical passivation method. Methods. Based on ADA97, 20 samples of Flexicast alloy were cast, surface-polished, and electrolytically passivated at room temperature for 24 h in a sodium sulfate solution. Corrosion and ion release of the alloys before and after passivation were studied in normal saline solution. Corrosion resistance and the ion release rates were measured by the weight loss method and atomic absorption spectroscopy, respectively, before and after passivation after 1, 2, 3, and 4 weeks. The surface morphology of the samples was examined using scanning electron microscopy (SEM). The results were analyzed with Kruskal-Wallis and Mann-Whitney tests using SPSS 20 at a significance level of <0.05. Results. The corrosion rate in the passivated samples was significantly lower than the non-passivated samples at the intervals (1, 2, 3, and 4 weeks) (P<0.05). The passivation of the alloy significantly reduced Co and Cr ion release in the first and fourth weeks, and in the first, second, and fourth weeks, respectively (P<0.05). SEM images revealed localized pitting associated with the corrosion, which was less significant in passivated samples. Conclusion. Chemical passivation of the CR-Co alloy significantly reduced corrosion and ionic release of Cr and Co over time.


  • Open Access

    Effect of surface passivation on corrosion of a cobalt-chromium dental alloy: surface morphology and chemical composition studies

    by Elnaz Moslehifard

    Background and Aim: Biocompatibility in some respects depends on the corrosion behavior of dental alloys. The purpose of this study was to investigate the effect of surface passivation of a cobalt chromium alloy on corrosion behavior. Materials and methods: In this experimental study, 20 samples of Flexicast dental alloy ...

  • Open Access

    Corrosion Behavior of a Nickel-Base Dental Casting Alloy in Artificial Saliva Studied by Weight Loss and Polarization Techniques

    by Elnaz Moslehifard, Mahsa Moslehifard, Sanaz Ghasemzadeh, Farzad Nasirpouri

    Objectives: Nickel-chromium (Ni-Cr) base dental alloys with desirable properties have been employed in prosthodontics for years. Corrosion behavior of a Ni-Cr base alloy in artificial saliva with different pH values is determined in this work. Materials and Methods: Corrosion behavior of Ni-Cr alloy was studied using weight loss described by corrosion rate (CR) in mils per year (mpy) and potentiodynamic polarization described by corrosion potential (CP) in mV and current density (CD) in mA/cm2 in artificial saliva with different pH. Surface morphology was studied using scanning electron microscopy (SEM). Statistical difference was assessed using one-way ANOVA and post-hoc Tukey's honestly significant difference (HSD) test with a difference significance of 95%. Results: In weight loss method, CR was 71.95±3.40, 17.26±1.03, 8.92±0.35, and 6.93±0.54 mpy at pH values of 2.5, 5, 7, and 9, respectively. CR obtained at pH of 2.5 was significantly different than that in other groups, but those obtained at pH of 5, 7, and 9 were not significantly different. In the polarization method, CP values were significantly different. CD measured at pH of 2.5 and 5 was significantly different than the rest of pH values (P<0.05). CRs at pH of 7 and 9 were not significantly different. SEM exhibited the formation of preferential sites of corrosion attacks influenced by pH. Conclusions: Both techniques revealed consistent results. Corrosion resistance increases as pH increases towards less acidic conditions. In more acidic saliva, the corrosion rate is greater. The less acidic saliva leads to formation of a more stable passive film on Ni, and the dissolution of Ni decreases, leading to lower CRs.