FMFarhang Mahboub

Farhang Mahboub

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Farhang Mahboub has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative in vitro evaluation of staining of natural tooth enamel by chitosan, chlorhexidine, and chitosan-chlorhexidine mouthwashes

    by Dorsa Samani, Ali Torab, Farhang Mahboub

    Chitosan mouthwash has antimicrobial and antiplaque properties with lower cytotoxicity than many conventional mouthwashes. Given the well-known side effect


  • Open Access

    Biomechanical evaluation of natural tooth–implant splints and comparison with implant cantilevers in the anterior region under fatigue tests

    by Mahsa Karimoghli, Shima Ghasemi, Tahereh Ghaffari, Farhang Mahboub

    Background. Several methods are used to replace lost teeth. This study aimed to reconstruct pre-maxillary conditions when a limited number of implants are available and investigate the biomechanics of the two methods available to dentists for use in these conditions (splinting natural teeth to implants and using a cantilever). Methods. This in vitro study involved the preparation of eight bridge samples, which were divided into two groups. Four healthy recently extracted central teeth with similar sizes and a maximum difference of 20% in root and crown length were selected as the dental abutments. After preparing the samples, the temporal retention of Temp Bond cement was evaluated using a universal testing machine at a speed of 0.5 mm/min for both samples. A digital torquemeter was used to measure the torque required to open the abutments before and after a fatigue test. Data were analyzed using SPSS statistics software. Results. A comparison of two types of prostheses before and after periodic loading showed that the amount of torque for loosening the abutment screw before applying force was the same in the two types of splint prostheses and cantilever prostheses. However, after applying a 200-N force, the amount of torque in the splinted prosthesis (19.75±1.70) was significantly higher than that of the cantilever prosthesis (12.1±5.73) (P<0.05). Conclusion. Generally, dental implant prostheses exhibited better support in vitro compared to cantilever prostheses.

  • Open Access

    The Comparison of Color Stability of Aloe Vera Gel and Chlorhexidine Solution on Acrylic Teeth

    by Farhang Mahboub, Amin Nourizadeh, Armin Izadpanah

    Background. There is insufficient knowledge about aloe vera color change property on acrylic teeth compared to other denture cleaners, especially chlorhexidine solution (CHX). Objective. The present study aimed to compare the color change property of the aloe vera and chlorhexidine solution on denture acrylic teeth. Methods. This study was experimental in vitro study design conducted in the dental laboratory of Tabriz University of Medical Sciences, Iran, 2021. The sample size in each group was 21 acrylic teeth which were randomly divided into aloe vera gel 100% and chlorhexidine solution 2% groups. Tooth colors were measured by a spectrophotometer (Spectro Shade Micro, MHT S.P.A., Milan, Italy). The immersion time in both groups was 36 hours. Data analyzed using an independent t‐test was used at a 95% of confidence level. Results. The comparison of the total color differences (ΔE) between the two groups was not statistically significant after 36 hours of immersion (P = 0.440). In the chlorhexidine group, the brightness of teeth was lower than that in the aloe vera group (P = 0.002). Conclusions. Clinicians should be aware that aloe vera gel does not change the color of denture acrylic teeth after 36 hours of immersion similar to the chlorhexidine solution. For patients who cannot use chlorhexidine, aloe vera gel is a good cleaner for denture acrylic teeth without worrying about the color change of the denture. It can be considered an acceptable cleaner for denture acrylic teeth.


  • Comparison of Different Cleaning Procedures of Implant Drills Using TC99

    by F. Parnia, Ali Hafezeqoran, B. Mahmoudian, E. Saati, E. Moslehifard, R. Koodaryan, F. Mahboub

    This study was carried out to evaluate implant drills' cleaning protocols efficiency as tested by the use of nuclear medicine. Eighty-one new drills of 2 different implant systems (Nobel Biocare and BioMet 3i) were selected as study samples. Six of these drills were used as positive control group, and the rest were contaminated with TC-labeled blood. The instruments were divided randomly into 5 groups (negative control group; group 1: immersion and brushing; group 2: immersion and brushing and then evaluation under magnifier; group 3: immersion and brushing and then ultrasonic cleaning for 15 minutes; and group 4: immersion and brushing and then ultrasonic cleaning for 30 minutes) so that every group contained equal number of each implant drills brand. Then the emitted γ rays were counted by means of a gamma counter. Statistically significant differences were observed between the full cleaning protocol and ultrasonication group (P < 0.009). Immersion and brushing, and ultrasonic cleaning for 30 minutes before sterilization, were the most effective methods to remove contamination. Complete removal of biologic debris was not attained with any of the cleaning techniques used. It is recommended to use ultrasonic cleaner for 30 minutes after immersion and brushing to achieve the best results.


  • The Effect of Occlusal Surface Relief of Dies on Marginal Adaptation of Metal‐Ceramic Casting Copings

    by Fariba Saleh Saber, Nader Abolfazli, Farhang Mahboub, Fariba Emadian Razavi

    Purpose The purpose of this study was to evaluate the impact of occlusal relief of dies on internal adaptation of metal-ceramic casting copings. Materials and Methods Standardized preparations were made on 80 extracted third molar teeth. Impressions were made with poly(vinyl siloxane), and stone dies were prepared. Dies were covered with four layers of die spacer, covering the entire preparation together with the occlusal surface excluding the apical 0.5 mm of the preparation in group 1 (40 specimens), and covering the same area excluding the occlusal surface in group 2 (40 specimens). Copings were cast using nickel-chromium-based metal ceramic alloy and cemented using zinc phosphate cement. The specimens were sectioned along the long axis. Internal discrepancies were recorded with a 0.001-mm resolution stereoscope at 6 points: the middle of the occlusal surface (MO), middle of the lingual wall (ML), middle of the buccal wall (MB), middle of the buccal shoulder finish line (MSH), middle of the lingual chamfer finish line (MCH), and middle of the buccal bevel finish line (MBL). Student's t-test was used for statistical analysis. Significance level was set at p < 0.05. Results The marginal discrepancies of group 1 were higher than those of group 2. Significant differences in discrepancies were found on MO (p < 0.0001), MSH (p = 0.012), and MBL (p = 0.035). The bevel margin showed the least marginal discrepancy following occlusal surface of the die with no relief. Conclusion Leaving the occlusal part of the die uncovered with the die spacer improved the crown seating considerably in the occlusal surface as well as shoulder and bevel margins.


  • Open Access

    Characteristics of anatomical landmarks in the mandibular interforaminal region: A cone-beam computed tomography study

    by F. Parnia, E. Moslehifard, A. Hafezeqoran, F. Mahboub, H. Mojaver-Kahnamoui

    Objectives: This study was conducted to assess appearance, visibility, location and course of anatomical landmarks in mandibular interforaminal region using cone-beam computed tomography (CBCT). Study design: A total of 96 CBCT examinations was re-evaluated to exploit anatomical landmarks. The examinations used the Promax 3D CBCT unit. A sole examiner carried out all the measurements. Visibilities of the anatomical landmarks were scored using a four-point rating scale. Results: The mandibular foramen, anterior loop, incisive canal and lingual foramen were observed in 100,84,83,49 % of the images, respectively. The mean size, diameter and width of anterior loop, incisive canal and lingual foramen were obtained 3.54± 1.41, 1.47±0.50 and 0.8 ± 0.09mm, respectively. Conclusion: It is not safe to recommend any definite distance mesially from the mental foramen. The diameter of the canals and foramens should be determined on a case-by-case basis to exploit the appropriate location for each individual.


  • Full‐Mouth Rehabilitation of a Patient with Severely Worn Dentition and Uneven Occlusal Plane: A Clinical Report

    by Elnaz Moslehifard, Sakineh Nikzad, Farideh Geraminpanah, Farhang Mahboub

    Severe tooth wear is frequently multifactorial and variable. Successful management is a subject of interest in dentistry. A critical aspect is to determine the occlusal vertical dimension (OVD) and a systematic approach that can lead to a predictable and favorable treatment prognosis. Management of patients with worn dentition is complex and difficult. Accurate clinical and radiographic examinations, a diagnostic wax‐up, and determining OVD are crucial. Using mini‐implants as orthodontic anchorage may facilitate orthodontic movement of teeth to improve their position, which is necessary for favorable prosthetic treatment. A 46‐year‐old man was referred for restoration of his worn and missing teeth. After diagnostic work‐up, provisional removable prostheses were fabricated for both jaws, evaluated clinically, and adjusted according to esthetic, phonetic, and vertical dimension criteria. Clinical crown lengthening and free gingival graft procedures were performed in appropriate areas. Drifting of the left posterior mandibular teeth was corrected using mini‐implants as orthodontic anchorage. Two conventional implants were inserted in the right mandibular edentulous area. After endodontic therapy of worn teeth, custom‐cast gold dowels and cores were fabricated, and provisional removable prostheses were replaced with fixed provisional restorations. Metal‐ceramic restorations were fabricated, and a removable partial denture with attachments was fabricated for maxillary edentulous areas. An occlusal splint was used to protect the restorations. Full‐mouth rehabilitation of the patient with severely worn dentition and an uneven occlusal plane was found to be successful after 3 years of follow‐up. This result can encourage clinicians to seek accurate diagnosis and treatment planning to treat such patients.


  • Tomographic volume evaluation of submandibular fossa in patients requiring dental implants

    by Fereidoun Parnia, Elnaz Moslehi Fard, Farhang Mahboub, Ali Hafezeqoran, Farzad Esmaeili Gavgani