DDDebashis Dutta

Debashis Dutta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Debashis Dutta has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Robust Gold Electrode Fabrication in a Microfluidic System

    by Sakur Mahmud, Debashis Dutta

  • A review of the zone broadening contributions in free‐flow electrophoresis

    by Sakur Mahmud, Sarker Ramproshad, Rajesh Deb, Debashis Dutta

    The broadening of analyte streams, as they migrate through a free‐flow electrophoresis (FFE) channel, often limits the resolving power of FFE separations. Under laminar flow conditions, such zonal spreading occurs due to analyte diffusion perpendicular to the direction of streamflow and variations in the lateral distance electrokinetically migrated by the analyte molecules. Although some of the factors that give rise to these contributions are inherent to the FFE method, others originate from non‐idealities in the system, such as Joule heating, pressure‐driven crossflows, and a difference between the electrical conductivities of the sample stream and background electrolyte. The injection process can further increase the stream width in FFE separations but normally influencing all analyte zones to an equal extent. Recently, several experimental and theoretical works have been reported that thoroughly investigate the various contributions to stream variance in an FFE device for better understanding, and potentially minimizing their magnitudes. In this review article, we carefully examine the findings from these studies and discuss areas in which more work is needed to advance our comprehension of the zone broadening contributions in FFE assays.


  • Open Access

    Characterization of liquid flow and electricity generation in a glass channel based evaporation-driven electrokinetic energy conversion device

    by Naoki Yanagisawa, Victor Dominguez, Sakur Mahmud, Debashis Dutta

    Evaporation-driven spontaneous capillary flow presents a promising approach for driving electrolytes through electrically charged channels and pores in electrokinetic energy conversion devices. However, there are no literature reports of detailed flow visualization in these systems and/or experimental observations relating the liquid velocity and evaporation rate to the generated voltage and current. In this manuscript, we describe such a visualization study for a glass channel based electrokinetic energy conversion device with one of its channel terminals left open to ambient air for facilitating the evaporation process. Fluorescence microscopy was used to measure the liquid velocity in the electrokinetic energy conversion channel by observing the advancement of an electrolyte solution dyed with a neutral tracer. The accumulation of the same dye tracer was also imaged at the open terminal of this glass conduit to estimate the rate of solvent evaporation, which was found to be consistent with the flow velocity measurements. Additionally, an electrochemical analyzer was employed to record the electrical voltage and current produced by the device under different operating conditions. The highest electrical power output was derived in our experiments upon flowing de-ionized water through a 1 μm deep channel, which also produced the fastest liquid velocity in it. Moreover, the energy conversion efficiency of our device was observed to increase for shallower channels and lower ionic strength electrolytes, consistent with previous literature reports on electrokinetic energy conversion platforms.


  • Fluorescence signal amplification by optical reflection in metal-coated nanowells

    by Sakur Mahmud, Debashis Dutta

    A significant amplification in the fluorescence signal is demonstrated when measured in metal (aluminum)-coated fluidic wells with volumes on the order of a nanoliter or smaller (nanowells). Photolithographic and wet etching procedures were used to fabricate these nanowells on glass substrates followed by vapor deposition of an aluminum layer on them. The fluorescence signal recorded in these structures was enhanced due to the reflection of the incident and emitted radiation by the metal layer as well as focusing of this light by the curvature of the well surface. While the first effect amplified the background signal in the entire assay chamber, the latter one produced signal hotspots around the edges and center of the nanowell. In this work, we were able to realize over a 20-fold enhancement in the fluorescence signal upon quantitating it at the central hotspot of an aluminum-coated circular nanowell with a depth and photo-patterned diameter of 30 µm and 38 µm, respectively. More interestingly, our experiments indicate that this enhancement factor may be further improved by optimizing the curvature of the nanowell surface to merge all the signal hotspots within a smaller detection zone. Finally, quantitative assays using horseradish peroxidase samples were performed on the reported signal enhancement platform to further demonstrate its utility for making sensitive analytical measurements. Graphical Abstract


  • Open Access

    Correction: Microfluidic ELISA employing an enzyme substrate and product species with similar detection properties

    by Basant Giri, Yukari Liu, Fidelis N. Nchocho, Robert C. Corcoran, Sakur Mahmud, Debashis Dutta

    Correction for ‘Microfluidic ELISA employing an enzyme substrate and product species with similar detection properties’ by Basant Giri et al., Analyst, 2018, 143, 989–998, https://doi.org/10.1039/C7AN01671A.


  • A compact microfluidic geometry for multiplexing enzyme‐linked immunosorbent assays

    by Basant Giri, Debashis Dutta

    We have previously reported a novel approach to implementing multiplex enzyme‐linked immunosorbent assay (ELISA) in connected microchannels by exploiting the slow diffusion of the enzyme reaction product across the different assay segments. This work builds on that report by implementing the noted assay in segments arranged along the circumference of a circular channel layout to reduce the footprint size and sample volume requirement. Using the current design, a 5‐plex cytokine ELISA was demonstrated in a 1.5 × 1.5‐cm region, which corresponded to a reduction in the footprint area by about a factor of 3 compared to that reported in our previous study. Additionally, the selective coating of our assay segments with the target molecules was realized in this work using electroosmosis instead of hydrodynamic flow as was the case in the previous report. This aspect of our experimental design is particularly significant as it permits the use of cross‐sectional channel dimensions significantly shorter than those employed in the current work. Moreover, the use of an electric field for coating purposes enables the integration of functionalities such as electrokinetic preconcentration of analyte molecules during the sample incubation period that can further enhance the capabilities of our assay method.

  • Band broadening in mobility shift affinity capillary electrophoresis due to pressure-driven flow

    by Debashis Dutta

    Mobility Shift Affinity Capillary Electrophoresis (msACE) presents a simple and powerful approach to determining the equilibrium and kinetic parameters governing the interaction between a variety of analyte and ligand molecules. These determinations often rely on measuring the elution peak profile for the analyte zone when migrated with a steady electric field. However, pressure-gradients applied intentionally or generated due to unwanted differences in the hydrostatic heads at the capillary/channel ends and/or a variation in the electroosmotic flow rate along the analysis column can significantly alter this peak profile introducing error in the estimated parameter values. To account for these alterations, this article describes a mathematical formulation for quantitating band broadening in msACE systems due to a steady pressure-driven flow in the Taylor–Aris dispersion limit with fast analyte-ligand binding kinetics. The current analysis shows that the additional zone dispersion under such conditions can be quantitated using four terms that scale with the square of the Péclet number calculated based on the pressure-driven flow velocity. While the first term among these quantitates the Taylor–Aris dispersion experienced by a neutral tracer advected by the pressure-gradient, the other three terms are proportional to the square of the difference in the diffusion coefficients for the analyte and analyte-ligand complex. Moreover, these latter terms also vary inversely with the Damköhler number computed as the ratio of the rate of reaction over that of diffusive mass transfer with the coefficient for each of the four terms shown to be dependent on the cross-sectional shape of the analysis column.


  • Reduction in sample injection bias using pressure gradients generated on chip

    by Yukari Liu, Ling Xia, Debashis Dutta

    Sample injection in microchip‐based capillary zone electrophoresis (CZE) frequently rely on the use of electric fields which can introduce differences in the injected volume for the various analytes depending on their electrophoretic mobilities and molecular diffusivities. While such injection biases may be minimized by employing hydrodynamic flows during the injection process, this approach typically requires excellent dynamic control over the pressure gradients applied within a microfluidic network. The current article describes a microchip device that offers this needed control by generating pressure gradients on‐chip via electrokinetic means to minimize the dead volume in the system. In order to realize the desired pressure‐generation capability, an electric field was applied across two channel segments of different depths to produce a mismatch in the electroosmotic flow rate at their junction. The resulting pressure‐driven flow was then utilized to introduce sample zones into a CZE channel with minimal injection bias. The reported injection strategy allowed the introduction of narrow sample plugs with spatial standard deviations down to about 45 μm. This injection technique was later integrated to a capillary zone electrophoresis process for analyzing amino acid samples yielding separation resolutions of about 4–6 for the analyte peaks in a 3 cm long analysis channel.