Rini Ann Jerin Amalorpavaraj
Research Subjects
Rini Ann Jerin Amalorpavaraj has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Chittathuru Dhanamjayulu
School of Electrical Engineering, Vellore Institute of Technology, Vellore 632014, Tamil Nadu, India
3 shared publications - Kaliannan Palanisamy
Vellore Institute of Technology
3 shared publications Arangarajan Vinayagam
2 shared publicationsNur Fadilah Ab Aziz
2 shared publications- Sanjeevikumar Padmanaban
Department of Electrical Engineering, IT and Cybernetics, University of South-Eastern Norway, Porsgrunn, Norway
2 shared publications Suganthi S T
2 shared publications
Latest Publications
- Open Access
- 6 April 2026
- Published by Elsevier in Results in Engineering
- Vol. 30
An extensive analysis of machine learning algorithms for the identification and differentiation of high impedance faults in various power network topologies
- 6 April 2026
- Published by Elsevier in Results in Engineering
- Vol. 30
Open AccessAn extensive analysis of machine learning algorithms for the identification and differentiation of high impedance faults in various power network topologies
- Open Access
- 3 March 2026
- Published by Elsevier in Results in Engineering
- Vol. 29
A hyperband optimized Bi-LSTM model for electric demand forecasting in diversified power systems
- 3 March 2026
- Published by Elsevier in Results in Engineering
- Vol. 29
Open AccessA hyperband optimized Bi-LSTM model for electric demand forecasting in diversified power systems
- Open Access
- 22 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 51254-51266
Real-Time Implementation of a 31-Level Asymmetrical Cascaded Multilevel Inverter for Dynamic Loads
Among the renewable energy applications, the most popular inverters are cascaded multilevel inverters. Irrespective of numerous benefits these inverters face reliability issues due to the presence of more circuit components in the design. This has been a critical challenge for researchers in designing inverters with enhanced reliability by reducing the THD. This paper proposes a thirty-one level asymmetric cascaded multilevel inverter for renewable energy applications. The proposed topology produces a waveforms consisting of staircase with high number of output levels with lesser components with low THD. The investigations on the feasibility and performance of MLI under steady state, transient and dynamic load disturbances. The results are validates from a 1.6kW system which provides the proposed inverter.
- 22 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 51254-51266
Open AccessReal-Time Implementation of a 31-Level Asymmetrical Cascaded Multilevel Inverter for Dynamic Loads
Among the renewable energy applications, the most popular inverters are cascaded multilevel inverters. Irrespective of numerous benefits these inverters face reliability issues due to the presence of more circuit components in the design. This has been a critical challenge for researchers in designing inverters with enhanced reliability by reducing the THD. This paper proposes a thirty-one level asymmetric cascaded multilevel inverter for renewable energy applications. The proposed topology produces a waveforms consisting of staircase with high number of output levels with lesser components with low THD. The investigations on the feasibility and performance of MLI under steady state, transient and dynamic load disturbances. The results are validates from a 1.6kW system which provides the proposed inverter.
- Open Access
- 2 January 2019
- Published by Taylor & Francis in Automatika
- Vol. 60 (1) , 19-27
Experimental verification of trinary DC source cascaded H-bridge multilevel inverter using unipolar pulse width modulation
Multilevel inverters (MLIs) are an imperative solution for high power and high voltage applications. The MLIs can be classified into two categories such as symmetric and asymmetric. The asymmetric type MLIs has large number of output voltage steps with less number of input DC voltage sources and switching devices. In this paper, a single phase asymmetric (trinary sequence DC source) Cascaded H-Bridge MLI has been developed using unipolar PWM control schemes. The topology can produce 27-level output voltage with the help of 12 switches and 3 DC sources. It has been examined with a diverse combination of multicarrier unipolar PWM control. The PWM control includes Phase Disposition (PDPWM), Alternative Opposition Disposition (APODPWM), Carrier overlapping (COPWM), and Variable Frequency (VFPWM). The harmonic content of output voltage for each technique has been observed with different modulation indices. The demonstration of proposed topology for generating 27-level output voltage has been tested through simulation in MATLAB-SIMULINK and verified with laboratory-based experimental setup. From the results, it is evident that the APODPWM offers quality output voltage with relatively low harmonic distortion. Also, it has been observed that COPWM performance is superior since it delivers relatively higher fundamental RMS output voltage.
- 2 January 2019
- Published by Taylor & Francis in Automatika
- Vol. 60 (1) , 19-27
Open AccessExperimental verification of trinary DC source cascaded H-bridge multilevel inverter using unipolar pulse width modulation
Multilevel inverters (MLIs) are an imperative solution for high power and high voltage applications. The MLIs can be classified into two categories such as symmetric and asymmetric. The asymmetric type MLIs has large number of output voltage steps with less number of input DC voltage sources and switching devices. In this paper, a single phase asymmetric (trinary sequence DC source) Cascaded H-Bridge MLI has been developed using unipolar PWM control schemes. The topology can produce 27-level output voltage with the help of 12 switches and 3 DC sources. It has been examined with a diverse combination of multicarrier unipolar PWM control. The PWM control includes Phase Disposition (PDPWM), Alternative Opposition Disposition (APODPWM), Carrier overlapping (COPWM), and Variable Frequency (VFPWM). The harmonic content of output voltage for each technique has been observed with different modulation indices. The demonstration of proposed topology for generating 27-level output voltage has been tested through simulation in MATLAB-SIMULINK and verified with laboratory-based experimental setup. From the results, it is evident that the APODPWM offers quality output voltage with relatively low harmonic distortion. Also, it has been observed that COPWM performance is superior since it delivers relatively higher fundamental RMS output voltage.
- 28 November 2017
- Published by Springer Nature
- p. 411-420
Comparative Analysis of Feed-Forward and Synchronous Reference Frame Control-Based Dynamic Voltage Restorer
- 28 November 2017
- Published by Springer Nature
- p. 411-420
Comparative Analysis of Feed-Forward and Synchronous Reference Frame Control-Based Dynamic Voltage Restorer
- Open Access
- 11 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 5, 20494-20503
Improved Fault Ride Through Capability in DFIG Based Wind Turbines Using Dynamic Voltage Restorer With Combined Feed-Forward and Feed-Back Control
This paper investigates the Fault Ride Through (FRT) capability improvement of a Doubly Fed Induction Generator (DFIG) wind turbine using a Dynamic Voltage Restorer (DVR). Series compensation of terminal voltage during fault conditions using DVR is carried out by injecting voltage at the point of common coupling to the grid voltage to maintain constant DFIG stator voltage. However, the control of DVR is crucial in order to improve the FRT capability in DFIG based wind turbines. The reported DVR verifies the use of a combined Feed-Forward and Feed-Back (CFFFB) based voltage control to obtain both good transient and steady-state responses. The improvement in performance of DVR using CFFFB control compared to the conventional Feed-Forward control is observed in terms of voltage sag mitigation capability, active and reactive power support without tripping, DC-link voltage balancing and fault current control. The advantage of utilizing this combined control is verified through MATLAB/Simulink based simulation results using 1.5 MW grid connected DFIG based wind turbine. The results show good transient and steady-state response and good reactive power support during both balanced and unbalanced fault conditions.
- 11 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 5, 20494-20503
Open AccessImproved Fault Ride Through Capability in DFIG Based Wind Turbines Using Dynamic Voltage Restorer With Combined Feed-Forward and Feed-Back Control
This paper investigates the Fault Ride Through (FRT) capability improvement of a Doubly Fed Induction Generator (DFIG) wind turbine using a Dynamic Voltage Restorer (DVR). Series compensation of terminal voltage during fault conditions using DVR is carried out by injecting voltage at the point of common coupling to the grid voltage to maintain constant DFIG stator voltage. However, the control of DVR is crucial in order to improve the FRT capability in DFIG based wind turbines. The reported DVR verifies the use of a combined Feed-Forward and Feed-Back (CFFFB) based voltage control to obtain both good transient and steady-state responses. The improvement in performance of DVR using CFFFB control compared to the conventional Feed-Forward control is observed in terms of voltage sag mitigation capability, active and reactive power support without tripping, DC-link voltage balancing and fault current control. The advantage of utilizing this combined control is verified through MATLAB/Simulink based simulation results using 1.5 MW grid connected DFIG based wind turbine. The results show good transient and steady-state response and good reactive power support during both balanced and unbalanced fault conditions.
- 1 September 2017
- Published by Elsevier in ISA Transactions
- Vol. 70, 465-474
Improved fault ride through capability of DFIG based wind turbines using synchronous reference frame control based dynamic voltage restorer
- 1 September 2017
- Published by Elsevier in ISA Transactions
- Vol. 70, 465-474
Improved fault ride through capability of DFIG based wind turbines using synchronous reference frame control based dynamic voltage restorer
- 7 July 2017
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 39 (8) , 891-897
Testing of low-voltage ride through capability compliance of wind turbines – a review
The increasing grid integration of wind power has led to the compulsory requirement of low-voltage ride through capability (LVRT) in wind turbines. Grid codes for LVRT capability of wind turbines are proposed in all major wind-energy-producing countries. The testing of LVRT capability compliance of the wind generators as per the specified grid codes during different fault conditions is essential to ensure its reliability. The testing process is generally done by the manufacturers and crucial for certification as per the IEC 61400-21 international standard for measurement of power quality characteristics of wind turbines. This review analyses the various testing tools under the software- and hardware-based categories. The review helps in understanding the present challenges in implementation of wind turbines, to alleviate the difficulty in LVRT testing procedures.
- 7 July 2017
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 39 (8) , 891-897
Testing of low-voltage ride through capability compliance of wind turbines – a review
The increasing grid integration of wind power has led to the compulsory requirement of low-voltage ride through capability (LVRT) in wind turbines. Grid codes for LVRT capability of wind turbines are proposed in all major wind-energy-producing countries. The testing of LVRT capability compliance of the wind generators as per the specified grid codes during different fault conditions is essential to ensure its reliability. The testing process is generally done by the manufacturers and crucial for certification as per the IEC 61400-21 international standard for measurement of power quality characteristics of wind turbines. This review analyses the various testing tools under the software- and hardware-based categories. The review helps in understanding the present challenges in implementation of wind turbines, to alleviate the difficulty in LVRT testing procedures.