Till Huelnhagen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Till Huelnhagen has a total of 97 co-authors. Here are the top co-authors by number of shared publications:
- Thoralf Niendorf
Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
9 shared publications Andreas Graessl
Berlin Ultrahigh Field Facility (B.U.F.F.), Max-Delbrueck Center for Molecular Medicine, Berlin, Germany
6 shared publicationsJan Rieger
MRI.TOOLS GmbH, Berlin, Germany
6 shared publications- Andreas Pohlmann
Max Delbrück Center for Molecular Medicine (MDC) in the Helmholtz Association
5 shared publications Celal Oezerdem
Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
5 shared publicationsJeanette Schulz-Menger
DZHK (German Centre for Cardiovascular Research), Partner Site, Berlin, Germany
5 shared publications
Latest Publications
- 10 June 2023
- Published by Elsevier in Journal Of Neuroradiology
- Vol. 51 (1) , 16-23
Evaluation of a nnU-Net type automated clinical volumetric tumor segmentation tool for diffuse low-grade glioma follow-up
- 10 June 2023
- Published by Elsevier in Journal Of Neuroradiology
- Vol. 51 (1) , 16-23
Evaluation of a nnU-Net type automated clinical volumetric tumor segmentation tool for diffuse low-grade glioma follow-up
- Open Access
- 5 March 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-9
Myocardial Effective Transverse Relaxation Time T 2 * is Elevated in Hypertrophic Cardiomyopathy: A 7.0 T Magnetic Resonance Imaging Study
Hypertrophic cardiomyopathy (HCM) is the most common genetic disease of the myocardium and bares the risk of progression to heart failure or sudden cardiac death. Identifying patients at risk remains an unmet need. Recognizing the dependence of microscopic susceptibility on tissue microstructure and on cardiac macromorphology we hypothesized that myocardial T2*might be altered in HCM patients compared to healthy controls. To test this hypothesis, myocardial T2*-mapping was conducted at 7.0 Tesla to enhance T2*-contrast. 2D CINE T2*-mapping was performed in healthy controls and HCM patients. To ensure that T2*is not dominated by macroscopic magnetic field inhomogeneities, volume selective B0shimming was applied. T2*changes in the interventricular septum across the cardiac cycle were analyzed together with left ventricular radius and ventricular septal wall thickness. The results show that myocardial T2*is elevated throughout the cardiac cycle in HCM patients compared to healthy controls. A mean septal T2* = 13.7 ± 1.1 ms (end-systole: T2*,systole = 15.0 ± 2.1, end-diastole: T2*,diastole = 13.4 ± 1.3 ms, T2*,systole/T2*,diastoleratio = 1.12) was observed in healthy controls. For HCM patients a mean septal T2* = 17.4 ± 1.4 ms (end-systole: T2*,systole = 17.7 ± 1.2 ms, end-diastole: T2*,diastole = 16.2 ± 2.5 ms, T2*,systole/T2*,diastoleratio = 1.09) was found. Our preliminary results provide encouragement that assessment of T2*and its changes across the cardiac cycle may benefit myocardial tissue characterization in HCM.
- 5 March 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-9
Open AccessMyocardial Effective Transverse Relaxation Time T 2 * is Elevated in Hypertrophic Cardiomyopathy: A 7.0 T Magnetic Resonance Imaging Study
Hypertrophic cardiomyopathy (HCM) is the most common genetic disease of the myocardium and bares the risk of progression to heart failure or sudden cardiac death. Identifying patients at risk remains an unmet need. Recognizing the dependence of microscopic susceptibility on tissue microstructure and on cardiac macromorphology we hypothesized that myocardial T2*might be altered in HCM patients compared to healthy controls. To test this hypothesis, myocardial T2*-mapping was conducted at 7.0 Tesla to enhance T2*-contrast. 2D CINE T2*-mapping was performed in healthy controls and HCM patients. To ensure that T2*is not dominated by macroscopic magnetic field inhomogeneities, volume selective B0shimming was applied. T2*changes in the interventricular septum across the cardiac cycle were analyzed together with left ventricular radius and ventricular septal wall thickness. The results show that myocardial T2*is elevated throughout the cardiac cycle in HCM patients compared to healthy controls. A mean septal T2* = 13.7 ± 1.1 ms (end-systole: T2*,systole = 15.0 ± 2.1, end-diastole: T2*,diastole = 13.4 ± 1.3 ms, T2*,systole/T2*,diastoleratio = 1.12) was observed in healthy controls. For HCM patients a mean septal T2* = 17.4 ± 1.4 ms (end-systole: T2*,systole = 17.7 ± 1.2 ms, end-diastole: T2*,diastole = 16.2 ± 2.5 ms, T2*,systole/T2*,diastoleratio = 1.09) was found. Our preliminary results provide encouragement that assessment of T2*and its changes across the cardiac cycle may benefit myocardial tissue characterization in HCM.
- Open Access
- 7 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 433-436
Myocardial T2* mapping at ultrahigh magnetic fields: in vivo myocardial tissue characteri-zation and assessment of cardiac physiology with magnetic resonance imaging
Mapping the effective transverse relaxation time T2* represents an emerging MRI tool for non-invasive myocardial tissue characterization and holds the promise to provide means for assessing myocardial (patho)physiology in vivo. This work takes advantage of the linear increase of susceptibility effects with magnetic field strength which renders it appealing to perform T2* mapping at ultrahigh magnetic fields and enables temporally resolved T2* mapping. Recognizing this potential this study examines the applicability of myocardial CINE T2* mapping in healthy volunteers and hypertrophic cardiomyopathy (HCM) patients at 7.0 Tesla and investigates its capability to distinguish between healthy myocardium and myocardium affected by HCM.
- 7 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 433-436
Open AccessMyocardial T2* mapping at ultrahigh magnetic fields: in vivo myocardial tissue characteri-zation and assessment of cardiac physiology with magnetic resonance imaging
Mapping the effective transverse relaxation time T2* represents an emerging MRI tool for non-invasive myocardial tissue characterization and holds the promise to provide means for assessing myocardial (patho)physiology in vivo. This work takes advantage of the linear increase of susceptibility effects with magnetic field strength which renders it appealing to perform T2* mapping at ultrahigh magnetic fields and enables temporally resolved T2* mapping. Recognizing this potential this study examines the applicability of myocardial CINE T2* mapping in healthy volunteers and hypertrophic cardiomyopathy (HCM) patients at 7.0 Tesla and investigates its capability to distinguish between healthy myocardium and myocardium affected by HCM.
- Open Access
- 4 April 2017
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 47 (1) , 282-285
Brain iron accumulation in Wilson's disease: A longitudinal imaging case study during anticopper treatment using 7.0T MRI and transcranial sonography
Level of Evidence: 5Technical Efficacy: Stage 3J. Magn. Reson. Imaging 2018;47:282–285.
- 4 April 2017
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 47 (1) , 282-285
Open AccessBrain iron accumulation in Wilson's disease: A longitudinal imaging case study during anticopper treatment using 7.0T MRI and transcranial sonography
Level of Evidence: 5Technical Efficacy: Stage 3J. Magn. Reson. Imaging 2018;47:282–285.
- 10 November 2016
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 78 (4) , 1533-1546
Magnetic resonance safety and compatibility of tantalum markers used in proton beam therapy for intraocular tumors: A 7.0 Tesla study
Purpose: Proton radiation therapy (PRT) is a standard treatment of uveal melanoma. PRT patients undergo implantation of ocular tantalum markers (OTMs) for treatment planning. Ultra‐high‐field MRI is a promising technique for 3D tumor visualization and PRT planning. This work examines MR safety and compatibility of OTMs at 7.0 Tesla.Methods: MR safety assessment included deflection angle measurements (DAMs), electromagnetic field (EMF) simulations for specific absorption rate (SAR) estimation, and temperature simulations for examining radiofrequency heating using a bow‐tie dipole antenna for transmission. MR compatibility was assessed by susceptibility artifacts in agarose, ex vivo pig eyes, and in an ex vivo tumor eye using gradient echo and fast spin‐echo imaging.Results: DAM (α < 1 °) demonstrated no risk attributed to magnetically induced OTM deflection. EMF simulations showed that an OTM can be approximated by a disk, demonstrated the need for averaging masses of mave = 0.01 g to accommodate the OTM, and provided SAR0.01g,maximum = 2.64 W/kg (Pin = 1W) in OTM presence. A transfer function was derived, enabling SAR0.01g estimation for individual patient scenarios without the OTM being integrated. Thermal simulations revealed minor OTM‐related temperature increase (δT < 15 mK). Susceptibility artifact size (<8 mm) and location suggest no restrictions for MRI of the nervus opticus.Conclusion: OTMs are not a per se contraindication for MRI. Magn Reson Med 78:1533–1546, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
- 10 November 2016
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 78 (4) , 1533-1546
Magnetic resonance safety and compatibility of tantalum markers used in proton beam therapy for intraocular tumors: A 7.0 Tesla study
Purpose: Proton radiation therapy (PRT) is a standard treatment of uveal melanoma. PRT patients undergo implantation of ocular tantalum markers (OTMs) for treatment planning. Ultra‐high‐field MRI is a promising technique for 3D tumor visualization and PRT planning. This work examines MR safety and compatibility of OTMs at 7.0 Tesla.Methods: MR safety assessment included deflection angle measurements (DAMs), electromagnetic field (EMF) simulations for specific absorption rate (SAR) estimation, and temperature simulations for examining radiofrequency heating using a bow‐tie dipole antenna for transmission. MR compatibility was assessed by susceptibility artifacts in agarose, ex vivo pig eyes, and in an ex vivo tumor eye using gradient echo and fast spin‐echo imaging.Results: DAM (α < 1 °) demonstrated no risk attributed to magnetically induced OTM deflection. EMF simulations showed that an OTM can be approximated by a disk, demonstrated the need for averaging masses of mave = 0.01 g to accommodate the OTM, and provided SAR0.01g,maximum = 2.64 W/kg (Pin = 1W) in OTM presence. A transfer function was derived, enabling SAR0.01g estimation for individual patient scenarios without the OTM being integrated. Thermal simulations revealed minor OTM‐related temperature increase (δT < 15 mK). Susceptibility artifact size (<8 mm) and location suggest no restrictions for MRI of the nervus opticus.Conclusion: OTMs are not a per se contraindication for MRI. Magn Reson Med 78:1533–1546, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
- 4 October 2016
- Published by Wiley in Neuropathology and Applied Neurobiology
- Vol. 43 (6) , 514-532
Brain iron accumulation in Wilson disease: a post mortem 7 Tesla MRI – histopathological study
Aims: In Wilson disease (WD), T2/T2*‐weighted (T2*w) MRI frequently shows hypointensity in the basal ganglia that is suggestive of paramagnetic deposits. It is currently unknown whether this hypointensity is related to copper or iron deposition. We examined the neuropathological correlates of this MRI pattern, particularly in relation to iron and copper concentrations.Methods: Brain slices from nine WD and six control cases were investigated using a 7T‐MRI system. High‐resolution T2*w images were acquired and R2* parametric maps were reconstructed using a multigradient recalled echo sequence. R2* was measured in the globus pallidus (GP) and the putamen. Corresponding histopathological sections containing the lentiform nucleus were examined using Turnbull iron staining, and double staining combining Turnbull with immunohistochemistry for macrophages or astrocytes. Quantitative densitometry of the iron staining as well as copper and iron concentrations were measured in the GP and putamen and correlated with R2* values.Results: T2*w hypointensity in the GP and/or putamen was apparent in WD cases and R2* values correlated with quantitative densitometry of iron staining. In WD, iron and copper concentrations were increased in the putamen compared to controls. R2* was correlated with the iron concentration in the GP and putamen, whereas no correlation was observed for the copper concentration. Patients with more pronounced pathological severity in the putamen displayed increased iron concentration, which correlated with an elevated number of iron‐containing macrophages.Conclusions: T2/T2*w hypointensity observed in vivo in the basal ganglia of WD patients is related to iron rather than copper deposits.
- 4 October 2016
- Published by Wiley in Neuropathology and Applied Neurobiology
- Vol. 43 (6) , 514-532
Brain iron accumulation in Wilson disease: a post mortem 7 Tesla MRI – histopathological study
Aims: In Wilson disease (WD), T2/T2*‐weighted (T2*w) MRI frequently shows hypointensity in the basal ganglia that is suggestive of paramagnetic deposits. It is currently unknown whether this hypointensity is related to copper or iron deposition. We examined the neuropathological correlates of this MRI pattern, particularly in relation to iron and copper concentrations.Methods: Brain slices from nine WD and six control cases were investigated using a 7T‐MRI system. High‐resolution T2*w images were acquired and R2* parametric maps were reconstructed using a multigradient recalled echo sequence. R2* was measured in the globus pallidus (GP) and the putamen. Corresponding histopathological sections containing the lentiform nucleus were examined using Turnbull iron staining, and double staining combining Turnbull with immunohistochemistry for macrophages or astrocytes. Quantitative densitometry of the iron staining as well as copper and iron concentrations were measured in the GP and putamen and correlated with R2* values.Results: T2*w hypointensity in the GP and/or putamen was apparent in WD cases and R2* values correlated with quantitative densitometry of iron staining. In WD, iron and copper concentrations were increased in the putamen compared to controls. R2* was correlated with the iron concentration in the GP and putamen, whereas no correlation was observed for the copper concentration. Patients with more pronounced pathological severity in the putamen displayed increased iron concentration, which correlated with an elevated number of iron‐containing macrophages.Conclusions: T2/T2*w hypointensity observed in vivo in the basal ganglia of WD patients is related to iron rather than copper deposits.
- 25 June 2016
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 77 (6) , 2381-2389
Myocardial effective transverse relaxation time T2* Correlates with left ventricular wall thickness: A 7.0 T MRI study
Purpose Myocardial effective relaxation time is commonly regarded as a surrogate for myocardial tissue oxygenation. However, it is legitimate to assume that there are multiple factors that influence . To this end, this study investigates the relationship between and cardiac macromorphology given by left ventricular (LV) wall thickness and left ventricular radius, and provides interpretation of the results in the physiological context. Methods High spatio‐temporally resolved myocardial CINE mapping was performed in 10 healthy volunteers using a 7.0 Tesla (T) full‐body MRI system. Ventricular septal wall thickness, left ventricular inner radius, and were analyzed. Macroscopic magnetic field changes were elucidated using cardiac phase–resolved magnetic field maps. Results Ventricular septal changes periodically over the cardiac cycle, increasing in systole and decreasing in diastole. Ventricular septal wall thickness and showed a significant positive correlation, whereas the inner LV radius and were negatively correlated. The effect of macroscopic magnetic field gradients on can be considered minor in the ventricular septum. Conclusion Our findings suggest that myocardial is related to tissue blood volume fraction. Temporally resolved mapping could be beneficial for myocardial tissue characterization and for understanding cardiac (patho)physiology in vivo. Magn Reson Med 77:2381–2389, 2017. © 2016 International Society for Magnetic Resonance in Medicine
- 25 June 2016
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 77 (6) , 2381-2389
Myocardial effective transverse relaxation time T2* Correlates with left ventricular wall thickness: A 7.0 T MRI study
Purpose Myocardial effective relaxation time is commonly regarded as a surrogate for myocardial tissue oxygenation. However, it is legitimate to assume that there are multiple factors that influence . To this end, this study investigates the relationship between and cardiac macromorphology given by left ventricular (LV) wall thickness and left ventricular radius, and provides interpretation of the results in the physiological context. Methods High spatio‐temporally resolved myocardial CINE mapping was performed in 10 healthy volunteers using a 7.0 Tesla (T) full‐body MRI system. Ventricular septal wall thickness, left ventricular inner radius, and were analyzed. Macroscopic magnetic field changes were elucidated using cardiac phase–resolved magnetic field maps. Results Ventricular septal changes periodically over the cardiac cycle, increasing in systole and decreasing in diastole. Ventricular septal wall thickness and showed a significant positive correlation, whereas the inner LV radius and were negatively correlated. The effect of macroscopic magnetic field gradients on can be considered minor in the ventricular septum. Conclusion Our findings suggest that myocardial is related to tissue blood volume fraction. Temporally resolved mapping could be beneficial for myocardial tissue characterization and for understanding cardiac (patho)physiology in vivo. Magn Reson Med 77:2381–2389, 2017. © 2016 International Society for Magnetic Resonance in Medicine
- Open Access
- 10 February 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (2) , e0148066
High Spatial Resolution Cardiovascular Magnetic Resonance at 7.0 Tesla in Patients with Hypertrophic Cardiomyopathy – First Experiences: Lesson Learned from 7.0 Tesla
Cardiovascular Magnetic Resonance (CMR) provides valuable information in patients with hypertrophic cardiomyopathy (HCM) based on myocardial tissue differentiation and the detection of small morphological details. CMR at 7.0T improves spatial resolution versus today’s clinical protocols. This capability is as yet untapped in HCM patients. We aimed to examine the feasibility of CMR at 7.0T in HCM patients and to demonstrate its capability for the visualization of subtle morphological details. We screened 131 patients with HCM. 13 patients (9 males, 56 ±31 years) and 13 healthy age- and gender-matched subjects (9 males, 55 ±31years) underwent CMR at 7.0T and 3.0T (Siemens, Erlangen, Germany). For the assessment of cardiac function and morphology, 2D CINE imaging was performed (voxel size at 7.0T: (1.4x1.4x2.5) mm3 and (1.4x1.4x4.0) mm3; at 3.0T: (1.8x1.8x6.0) mm3). Late gadolinium enhancement (LGE) was performed at 3.0T for detection of fibrosis. All scans were successful and evaluable. At 3.0T, quantification of the left ventricle (LV) showed similar results in short axis view vs. the biplane approach (LVEDV, LVESV, LVMASS, LVEF) (p = 0.286; p = 0.534; p = 0.155; p = 0.131). The LV-parameters obtained at 7.0T where in accordance with the 3.0T data (pLVEDV = 0.110; pLVESV = 0.091; pLVMASS = 0.131; pLVEF = 0.182). LGE was detectable in 12/13 (92%) of the HCM patients. High spatial resolution CINE imaging at 7.0T revealed hyperintense regions, identifying myocardial crypts in 7/13 (54%) of the HCM patients. All crypts were located in the LGE-positive regions. The crypts were not detectable at 3.0T using a clinical protocol. CMR at 7.0T is feasible in patients with HCM. High spatial resolution gradient echo 2D CINE imaging at 7.0T allowed the detection of subtle morphological details in regions of extended hypertrophy and LGE.
- 10 February 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (2) , e0148066
Open AccessHigh Spatial Resolution Cardiovascular Magnetic Resonance at 7.0 Tesla in Patients with Hypertrophic Cardiomyopathy – First Experiences: Lesson Learned from 7.0 Tesla
Cardiovascular Magnetic Resonance (CMR) provides valuable information in patients with hypertrophic cardiomyopathy (HCM) based on myocardial tissue differentiation and the detection of small morphological details. CMR at 7.0T improves spatial resolution versus today’s clinical protocols. This capability is as yet untapped in HCM patients. We aimed to examine the feasibility of CMR at 7.0T in HCM patients and to demonstrate its capability for the visualization of subtle morphological details. We screened 131 patients with HCM. 13 patients (9 males, 56 ±31 years) and 13 healthy age- and gender-matched subjects (9 males, 55 ±31years) underwent CMR at 7.0T and 3.0T (Siemens, Erlangen, Germany). For the assessment of cardiac function and morphology, 2D CINE imaging was performed (voxel size at 7.0T: (1.4x1.4x2.5) mm3 and (1.4x1.4x4.0) mm3; at 3.0T: (1.8x1.8x6.0) mm3). Late gadolinium enhancement (LGE) was performed at 3.0T for detection of fibrosis. All scans were successful and evaluable. At 3.0T, quantification of the left ventricle (LV) showed similar results in short axis view vs. the biplane approach (LVEDV, LVESV, LVMASS, LVEF) (p = 0.286; p = 0.534; p = 0.155; p = 0.131). The LV-parameters obtained at 7.0T where in accordance with the 3.0T data (pLVEDV = 0.110; pLVESV = 0.091; pLVMASS = 0.131; pLVEF = 0.182). LGE was detectable in 12/13 (92%) of the HCM patients. High spatial resolution CINE imaging at 7.0T revealed hyperintense regions, identifying myocardial crypts in 7/13 (54%) of the HCM patients. All crypts were located in the LGE-positive regions. The crypts were not detectable at 3.0T using a clinical protocol. CMR at 7.0T is feasible in patients with HCM. High spatial resolution gradient echo 2D CINE imaging at 7.0T allowed the detection of subtle morphological details in regions of extended hypertrophy and LGE.
- Open Access
- 29 January 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , srep17230-17230
Normothermic Mouse Functional MRI of Acute Focal Thermostimulation for Probing Nociception
Combining mouse genomics and functional magnetic resonance imaging (fMRI) provides a promising tool to unravel the molecular mechanisms of chronic pain. Probing murine nociception via the blood oxygenation level-dependent (BOLD) effect is still challenging due to methodological constraints. Here we report on the reproducible application of acute noxious heat stimuli to examine the feasibility and limitations of functional brain mapping for central pain processing in mice. Recent technical and procedural advances were applied for enhanced BOLD signal detection and a tight control of physiological parameters. The latter includes the development of a novel mouse cradle designed to maintain whole-body normothermia in anesthetized mice during fMRI in a way that reflects the thermal status of awake, resting mice. Applying mild noxious heat stimuli to wildtype mice resulted in highly significant BOLD patterns in anatomical brain structures forming the pain matrix, which comprise temporal signal intensity changes of up to 6% magnitude. We also observed sub-threshold correlation patterns in large areas of the brain, as well as alterations in mean arterial blood pressure (MABP) in response to the applied stimulus.
- 29 January 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , srep17230-17230
Open AccessNormothermic Mouse Functional MRI of Acute Focal Thermostimulation for Probing Nociception
Combining mouse genomics and functional magnetic resonance imaging (fMRI) provides a promising tool to unravel the molecular mechanisms of chronic pain. Probing murine nociception via the blood oxygenation level-dependent (BOLD) effect is still challenging due to methodological constraints. Here we report on the reproducible application of acute noxious heat stimuli to examine the feasibility and limitations of functional brain mapping for central pain processing in mice. Recent technical and procedural advances were applied for enhanced BOLD signal detection and a tight control of physiological parameters. The latter includes the development of a novel mouse cradle designed to maintain whole-body normothermia in anesthetized mice during fMRI in a way that reflects the thermal status of awake, resting mice. Applying mild noxious heat stimuli to wildtype mice resulted in highly significant BOLD patterns in anatomical brain structures forming the pain matrix, which comprise temporal signal intensity changes of up to 6% magnitude. We also observed sub-threshold correlation patterns in large areas of the brain, as well as alterations in mean arterial blood pressure (MABP) in response to the applied stimulus.
- Open Access
- 12 November 2015
- Published by Frontiers Media SA in Frontiers in Pharmacology
- Vol. 6, 255
Advancing Cardiovascular, Neurovascular, and Renal Magnetic Resonance Imaging in Small Rodents Using Cryogenic Radiofrequency Coil Technology
Research in pathologies of the brain, heart and kidney have gained immensely from the plethora of studies that have helped shape new methods in magnetic resonance (MR) for characterizing preclinical disease models. Methodical probing into preclinical animal models by MR is invaluable since it allows a careful interpretation and extrapolation of data derived from these models to human disease. In this review we will focus on the applications of cryogenic radiofrequency (RF) coils in small animal MR as a means of boosting image quality (e.g. by supporting MR microscopy) and making data acquisition more efficient (e.g. by reducing measuring time); both being important constituents for thorough investigational studies on animal models of disease. This review attempts to make the (bio)medical imaging, molecular medicine and pharmaceutical communities aware of this productive ferment and its outstanding significance for anatomical and functional MR in small rodents. The goal is to inspire a more intense interdisciplinary collaboration across the fields to further advance and progress non-invasive MR methods that ultimately support thorough (patho)physiological characterization of animal disease models. In this review, current and potential future applications for the RF coil technology in cardiovascular, neurovascular and renal disease will be discussed.
- 12 November 2015
- Published by Frontiers Media SA in Frontiers in Pharmacology
- Vol. 6, 255
Open AccessAdvancing Cardiovascular, Neurovascular, and Renal Magnetic Resonance Imaging in Small Rodents Using Cryogenic Radiofrequency Coil Technology
Research in pathologies of the brain, heart and kidney have gained immensely from the plethora of studies that have helped shape new methods in magnetic resonance (MR) for characterizing preclinical disease models. Methodical probing into preclinical animal models by MR is invaluable since it allows a careful interpretation and extrapolation of data derived from these models to human disease. In this review we will focus on the applications of cryogenic radiofrequency (RF) coils in small animal MR as a means of boosting image quality (e.g. by supporting MR microscopy) and making data acquisition more efficient (e.g. by reducing measuring time); both being important constituents for thorough investigational studies on animal models of disease. This review attempts to make the (bio)medical imaging, molecular medicine and pharmaceutical communities aware of this productive ferment and its outstanding significance for anatomical and functional MR in small rodents. The goal is to inspire a more intense interdisciplinary collaboration across the fields to further advance and progress non-invasive MR methods that ultimately support thorough (patho)physiological characterization of animal disease models. In this review, current and potential future applications for the RF coil technology in cardiovascular, neurovascular and renal disease will be discussed.