High Spatial Resolution Cardiovascular Magnetic Resonance at 7.0 Tesla in Patients with Hypertrophic Cardiomyopathy – First Experiences: Lesson Learned from 7.0 Tesla
Open Access
- 10 February 2016
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (2) , e0148066
Abstract
Cardiovascular Magnetic Resonance (CMR) provides valuable information in patients with hypertrophic cardiomyopathy (HCM) based on myocardial tissue differentiation and the detection of small morphological details. CMR at 7.0T improves spatial resolution versus today’s clinical protocols. This capability is as yet untapped in HCM patients. We aimed to examine the feasibility of CMR at 7.0T in HCM patients and to demonstrate its capability for the visualization of subtle morphological details. We screened 131 patients with HCM. 13 patients (9 males, 56 ±31 years) and 13 healthy age- and gender-matched subjects (9 males, 55 ±31years) underwent CMR at 7.0T and 3.0T (Siemens, Erlangen, Germany). For the assessment of cardiac function and morphology, 2D CINE imaging was performed (voxel size at 7.0T: (1.4x1.4x2.5) mm3 and (1.4x1.4x4.0) mm3; at 3.0T: (1.8x1.8x6.0) mm3). Late gadolinium enhancement (LGE) was performed at 3.0T for detection of fibrosis. All scans were successful and evaluable. At 3.0T, quantification of the left ventricle (LV) showed similar results in short axis view vs. the biplane approach (LVEDV, LVESV, LVMASS, LVEF) (p = 0.286; p = 0.534; p = 0.155; p = 0.131). The LV-parameters obtained at 7.0T where in accordance with the 3.0T data (pLVEDV = 0.110; pLVESV = 0.091; pLVMASS = 0.131; pLVEF = 0.182). LGE was detectable in 12/13 (92%) of the HCM patients. High spatial resolution CINE imaging at 7.0T revealed hyperintense regions, identifying myocardial crypts in 7/13 (54%) of the HCM patients. All crypts were located in the LGE-positive regions. The crypts were not detectable at 3.0T using a clinical protocol. CMR at 7.0T is feasible in patients with HCM. High spatial resolution gradient echo 2D CINE imaging at 7.0T allowed the detection of subtle morphological details in regions of extended hypertrophy and LGE.Keywords
This publication has 30 references indexed in Scilit:
- Myocardial T1 and T2 mapping at 3 T: reference values, influencing factors and implicationsJournal of Cardiovascular Magnetic Resonance, 2013
- Standardized image interpretation and post processing in cardiovascular magnetic resonance: Society for Cardiovascular Magnetic Resonance (SCMR) Board of Trustees Task Force on Standardized Post ProcessingJournal of Cardiovascular Magnetic Resonance, 2013
- Assessment of the right ventricle with cardiovascular magnetic resonance at 7 TeslaJournal of Cardiovascular Magnetic Resonance, 2013
- High Spatial Resolution and Temporally Resolved T2* Mapping of Normal Human Myocardium at 7.0 Tesla: An Ultrahigh Field Magnetic Resonance Feasibility StudyPLOS ONE, 2012
- Detailing Radio Frequency Heating Induced by Coronary Stents: A 7.0 Tesla Magnetic Resonance StudyPLOS ONE, 2012
- Multiple Sclerosis Lesions and Irreversible Brain Tissue DamageArchives of Neurology, 2012
- 2011 ACCF/AHA Guideline for the Diagnosis and Treatment of Hypertrophic CardiomyopathyJACC, 2011
- Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 TeslaJournal of Cardiovascular Magnetic Resonance, 2010
- In vivo imaging of cortical pathology in multiple sclerosis using ultra-high field MRINeurology, 2009
- Multiecho dixon fat and water separation method for detecting fibrofatty infiltration in the myocardiumMagnetic Resonance in Medicine, 2008