Hung-Ju Lin
Hung-Ju Lin has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Benedikt Herzog
High Frequency Laboratory, Federal Institute of Metrology METAS, Bern-Wabern 3003, Switzerland
2 shared publications - Bruno Eckmann
Federal Institute of Metrology METAS, Bern-Wabern, SWITZERLAND
2 shared publications - Sophie de Préville
Federal Institute of Metrology METAS Lindenweg 50 3003 Bern‐Wabern Switzerland
2 shared publications - Zhuoying Chen
Laboratoire de Physique et d'Etude des Matériaux (LPEM) ESPCI Paris PSL University Sorbonne Université CNRS UMR 8213, 10 Rue Vauquelin Paris F‐75005 France
2 shared publications - Damien Richert
Lab Natl Metrol & Essais LNE, Trappes, France
1 shared publication - Didier Theron
IEMN, (DHS), Avenue Poincaré, B.P. 69, Villeneuve d'Ascq Cedex, 59652, France
1 shared publication
Latest Publications
- Open Access
- 16 May 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (8) , 085010
Coaxial tips for a scanning microwave microscope and its calibration with dielectric references
Scanning microwave microscopy (SMM) is a combination of an atomic force microscope with a vector network analyzer (VNA) to measure locally resolved impedances. The technique finds application in the realms of semiconductor industries, material sciences, or biology. To determine quantitative material properties from the measured impedances, the system must be calibrated. Transferring the calibration from the calibration substrate onto the material under test is strongly limited when using unshielded probes, as the electromagnetic coupling to the surroundings can reach several centimeters. This work reports the fabrication of coaxially shielded probes for a scanning microwave microscope and their integration into such an instrument. We discuss a calibration method with dielectric references, using a simulation-assisted 1-port VNA calibration algorithm. Uncertainty considerations of the measurement process are included and propagation throughout the algorithm is performed. The calibration is verified with an additional dielectric reference. As an application example, the results for a static-random-access memory sample are presented. We identified system-related drift and trace noise as the dominant contributors to the uncertainties of the calibrated results. The here presented shielded tips can broaden the application scope of SMM, as they are door-openers for measurements in liquids.
- 16 May 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (8) , 085010
Open AccessCoaxial tips for a scanning microwave microscope and its calibration with dielectric references
Scanning microwave microscopy (SMM) is a combination of an atomic force microscope with a vector network analyzer (VNA) to measure locally resolved impedances. The technique finds application in the realms of semiconductor industries, material sciences, or biology. To determine quantitative material properties from the measured impedances, the system must be calibrated. Transferring the calibration from the calibration substrate onto the material under test is strongly limited when using unshielded probes, as the electromagnetic coupling to the surroundings can reach several centimeters. This work reports the fabrication of coaxially shielded probes for a scanning microwave microscope and their integration into such an instrument. We discuss a calibration method with dielectric references, using a simulation-assisted 1-port VNA calibration algorithm. Uncertainty considerations of the measurement process are included and propagation throughout the algorithm is performed. The calibration is verified with an additional dielectric reference. As an application example, the results for a static-random-access memory sample are presented. We identified system-related drift and trace noise as the dominant contributors to the uncertainties of the calibrated results. The here presented shielded tips can broaden the application scope of SMM, as they are door-openers for measurements in liquids.
- 20 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Comparison of Impedance Matching Networks for Scanning Microwave Microscopy
In this paper, a definition of the gain and added noise of impedance matching networks for scanning microwave microscopy is given. This definition can be used to compare different impedance matching techniques independently of the instrument used to measure the S-parameter. As a demonstration, impedance matching devices consisting of a Beatty line, a tuner, and interferometric setups with and without amplifiers have been investigated. Measurement frequencies up to 28 GHz are used, and the maximal resulting gain found was 9504.7 per Siemens.
- 20 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Comparison of Impedance Matching Networks for Scanning Microwave Microscopy
In this paper, a definition of the gain and added noise of impedance matching networks for scanning microwave microscopy is given. This definition can be used to compare different impedance matching techniques independently of the instrument used to measure the S-parameter. As a demonstration, impedance matching devices consisting of a Beatty line, a tuner, and interferometric setups with and without amplifiers have been investigated. Measurement frequencies up to 28 GHz are used, and the maximal resulting gain found was 9504.7 per Siemens.
- Open Access
- 22 April 2019
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 125 (16) , 163101
Nanoscale thermal characterization of high aspect ratio gold nanorods for photothermal applications at λ = 1.5 μm
We synthetized gold nanorods that present a high aspect ratio (>10) and possess a surface plasmon resonance in the near-infrared, in the 1300–1600 nm spectral range. Using a single Er3+-doped NaYF4 nanocrystal deposited on their surface, we measured the temperature increase of a few nanorods excited at their surface plasmon resonance wavelength. We observed a temperature increase of more than 30 °C for an excitation power density of 3 mW/μm2. This experiment shows that a very small amount of nanorods can be used for obtaining an intense and localized photothermal effect. Applications can be found in the design of inexpensive infrared photodetectors and photothermal therapy in the third biological window. In addition, the association of gold nanorods with an Er3+ doped nanocrystal constitutes a very interesting hybrid heater/temperature sensor.
- 22 April 2019
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 125 (16) , 163101
Open AccessNanoscale thermal characterization of high aspect ratio gold nanorods for photothermal applications at λ = 1.5 μm
We synthetized gold nanorods that present a high aspect ratio (>10) and possess a surface plasmon resonance in the near-infrared, in the 1300–1600 nm spectral range. Using a single Er3+-doped NaYF4 nanocrystal deposited on their surface, we measured the temperature increase of a few nanorods excited at their surface plasmon resonance wavelength. We observed a temperature increase of more than 30 °C for an excitation power density of 3 mW/μm2. This experiment shows that a very small amount of nanorods can be used for obtaining an intense and localized photothermal effect. Applications can be found in the design of inexpensive infrared photodetectors and photothermal therapy in the third biological window. In addition, the association of gold nanorods with an Er3+ doped nanocrystal constitutes a very interesting hybrid heater/temperature sensor.
- 18 December 2017
- Published by AIP Publishing in Applied Physics Letters
- Vol. 111 (25) , 251109
Fluorescence enhancement near single TiO2 nanodisks
We present a near-field optical study of TiO2 nanodisks by fluorescence scanning near-field optical microscopy. The localization of light and the fluorescence enhancement near the dielectric structures are visualized with a lateral resolution of ∼λ/5 using an Er/Yb-codoped fluorescent nanocrystal glued at the end of a sharp scanning tip. We observed that the intensity patterns strongly depend on the disk size, forming lobes for a diameter close to the wavelength and a single bright spot for smaller structures. Although the experiments were performed out of resonance, a maximum fluorescence enhancement of 2.3 was observed near 700 nm-wide disks. The evolution of the fluorescence pattern as a function of the disk size is in good agreement with the near-field maps calculated by the finite-difference time-domain method, in both two and three dimensions above the structures.
- 18 December 2017
- Published by AIP Publishing in Applied Physics Letters
- Vol. 111 (25) , 251109
Fluorescence enhancement near single TiO2 nanodisks
We present a near-field optical study of TiO2 nanodisks by fluorescence scanning near-field optical microscopy. The localization of light and the fluorescence enhancement near the dielectric structures are visualized with a lateral resolution of ∼λ/5 using an Er/Yb-codoped fluorescent nanocrystal glued at the end of a sharp scanning tip. We observed that the intensity patterns strongly depend on the disk size, forming lobes for a diameter close to the wavelength and a single bright spot for smaller structures. Although the experiments were performed out of resonance, a maximum fluorescence enhancement of 2.3 was observed near 700 nm-wide disks. The evolution of the fluorescence pattern as a function of the disk size is in good agreement with the near-field maps calculated by the finite-difference time-domain method, in both two and three dimensions above the structures.