Benedikt Herzog
Benedikt Herzog has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Bruno Eckmann
Federal Institute of Metrology METAS, Bern-Wabern, SWITZERLAND
2 shared publications - Hung-Ju Lin
High Frequency Laboratory, Federal Institute of Metrology METAS, Bern-Wabern 3003, Switzerland
2 shared publications - Sophie de Préville
Federal Institute of Metrology METAS Lindenweg 50 3003 Bern‐Wabern Switzerland
2 shared publications - Damien Richert
Lab Natl Metrol & Essais LNE, Trappes, France
1 shared publication - Didier Theron
IEMN, (DHS), Avenue Poincaré, B.P. 69, Villeneuve d'Ascq Cedex, 59652, France
1 shared publication - François Piquemal
Laboratoire national de métrologie et d'essai (LNE), FR-78197 Trappes Cedex, France
1 shared publication
Latest Publications
- Open Access
- 16 May 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (8) , 085010
Coaxial tips for a scanning microwave microscope and its calibration with dielectric references
Scanning microwave microscopy (SMM) is a combination of an atomic force microscope with a vector network analyzer (VNA) to measure locally resolved impedances. The technique finds application in the realms of semiconductor industries, material sciences, or biology. To determine quantitative material properties from the measured impedances, the system must be calibrated. Transferring the calibration from the calibration substrate onto the material under test is strongly limited when using unshielded probes, as the electromagnetic coupling to the surroundings can reach several centimeters. This work reports the fabrication of coaxially shielded probes for a scanning microwave microscope and their integration into such an instrument. We discuss a calibration method with dielectric references, using a simulation-assisted 1-port VNA calibration algorithm. Uncertainty considerations of the measurement process are included and propagation throughout the algorithm is performed. The calibration is verified with an additional dielectric reference. As an application example, the results for a static-random-access memory sample are presented. We identified system-related drift and trace noise as the dominant contributors to the uncertainties of the calibrated results. The here presented shielded tips can broaden the application scope of SMM, as they are door-openers for measurements in liquids.
- 16 May 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (8) , 085010
Open AccessCoaxial tips for a scanning microwave microscope and its calibration with dielectric references
Scanning microwave microscopy (SMM) is a combination of an atomic force microscope with a vector network analyzer (VNA) to measure locally resolved impedances. The technique finds application in the realms of semiconductor industries, material sciences, or biology. To determine quantitative material properties from the measured impedances, the system must be calibrated. Transferring the calibration from the calibration substrate onto the material under test is strongly limited when using unshielded probes, as the electromagnetic coupling to the surroundings can reach several centimeters. This work reports the fabrication of coaxially shielded probes for a scanning microwave microscope and their integration into such an instrument. We discuss a calibration method with dielectric references, using a simulation-assisted 1-port VNA calibration algorithm. Uncertainty considerations of the measurement process are included and propagation throughout the algorithm is performed. The calibration is verified with an additional dielectric reference. As an application example, the results for a static-random-access memory sample are presented. We identified system-related drift and trace noise as the dominant contributors to the uncertainties of the calibrated results. The here presented shielded tips can broaden the application scope of SMM, as they are door-openers for measurements in liquids.
- 20 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Comparison of Impedance Matching Networks for Scanning Microwave Microscopy
In this paper, a definition of the gain and added noise of impedance matching networks for scanning microwave microscopy is given. This definition can be used to compare different impedance matching techniques independently of the instrument used to measure the S-parameter. As a demonstration, impedance matching devices consisting of a Beatty line, a tuner, and interferometric setups with and without amplifiers have been investigated. Measurement frequencies up to 28 GHz are used, and the maximal resulting gain found was 9504.7 per Siemens.
- 20 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Comparison of Impedance Matching Networks for Scanning Microwave Microscopy
In this paper, a definition of the gain and added noise of impedance matching networks for scanning microwave microscopy is given. This definition can be used to compare different impedance matching techniques independently of the instrument used to measure the S-parameter. As a demonstration, impedance matching devices consisting of a Beatty line, a tuner, and interferometric setups with and without amplifiers have been investigated. Measurement frequencies up to 28 GHz are used, and the maximal resulting gain found was 9504.7 per Siemens.