Matthew T. Cook
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Matthew T. Cook has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Howard L. Hall
University of Tennessee, Knoxville
7 shared publications Andrew V. Giminaro
University of Tennessee
3 shared publicationsJohn D. Auxier
Department of Nuclear Engineering, University of Tennessee, Knoxville, USA
3 shared publications- Michael B. Shattan
National Nuclear Security Administration
3 shared publications - Ashwin P. Rao
Air Force Research Laboratory
2 shared publications C. J. Oldham
University of Tennessee
2 shared publications
Latest Publications
- Open Access
Quantitative Analysis of Cerium-Gallium Alloys Using a Hand-Held Laser Induced Breakdown Spectroscopy Device
A hand-held laser-induced breakdown spectroscopy device was used to acquire spectral emission data from laser-induced plasmas created on the surface of cerium-gallium alloy samples with Ga concentrations ranging from 0–3 weight percent. Ionic and neutral emission lines of the two constituent elements were then extracted and used to generate calibration curves relating the emission line intensity ratios to the gallium concentration of the alloy. The Ga I 287.4-nm emission line was determined to be superior for the purposes of Ga detection and concentration determination. A limit of detection below 0.25% was achieved using a multivariate regression model of the Ga I 287.4-nm line ratio versus two separate Ce II emission lines. This LOD is considered a conservative estimation of the technique’s capability given the type of the calibration samples available and the low power (5 mJ per 1-ns pulse) and resolving power ( / = 4000) of this hand-held device. Nonetheless, the utility of the technique is demonstrated via a detailed mapping analysis of the surface Ga distribution of a Ce-Ga sample, which reveals significant heterogeneity resulting from the sample production process.Open AccessQuantitative Analysis of Cerium-Gallium Alloys Using a Hand-Held Laser Induced Breakdown Spectroscopy Device
A hand-held laser-induced breakdown spectroscopy device was used to acquire spectral emission data from laser-induced plasmas created on the surface of cerium-gallium alloy samples with Ga concentrations ranging from 0–3 weight percent. Ionic and neutral emission lines of the two constituent elements were then extracted and used to generate calibration curves relating the emission line intensity ratios to the gallium concentration of the alloy. The Ga I 287.4-nm emission line was determined to be superior for the purposes of Ga detection and concentration determination. A limit of detection below 0.25% was achieved using a multivariate regression model of the Ga I 287.4-nm line ratio versus two separate Ce II emission lines. This LOD is considered a conservative estimation of the technique’s capability given the type of the calibration samples available and the low power (5 mJ per 1-ns pulse) and resolving power ( / = 4000) of this hand-held device. Nonetheless, the utility of the technique is demonstrated via a detailed mapping analysis of the surface Ga distribution of a Ce-Ga sample, which reveals significant heterogeneity resulting from the sample production process. - Open Access
- 29 July 2019
- Published by MDPI AG in Preprints.org
Quantitative Analysis of Cerium-Gallium Alloys Using a Hand-Held Laser Induced Breakdown Spectroscopy Device
A hand-held laser-induced breakdown spectroscopy device was used to acquire spectral emission data from laser-induced plasmas created on the surface of cerium-gallium alloy samples with Ga concentrations ranging from 0 to 3 weight percent. Ionic and neutral emission lines of the two constituent elements were then extracted and used to generate calibration curves relating the emission line intensity ratios to the gallium concentration of the alloy. The Ga I 287.4 nm emission line was determined to be superior for the purposes of Ga detection and concentration determination.A limit of detection below 0.25% was achieved using a multivariate regression model of the Ga I287.4 nm line ratio versus two separate Ce II emission lines. This LOD is considered a conservative estimation of technique’s capability given the type of the calibration samples available and low power( 5 mJ per 1 ns pulse) and resolving power (λ/∆λ= 4000) of this handheld device. Nonetheless, the utility of the technique is demonstrated via a detailed mapping analysis of the surface Ga distribution of a Ce-Ga sample which reveals significant heterogeneity resulting from the sample production process.
- 29 July 2019
- Published by MDPI AG in Preprints.org
Open AccessQuantitative Analysis of Cerium-Gallium Alloys Using a Hand-Held Laser Induced Breakdown Spectroscopy Device
A hand-held laser-induced breakdown spectroscopy device was used to acquire spectral emission data from laser-induced plasmas created on the surface of cerium-gallium alloy samples with Ga concentrations ranging from 0 to 3 weight percent. Ionic and neutral emission lines of the two constituent elements were then extracted and used to generate calibration curves relating the emission line intensity ratios to the gallium concentration of the alloy. The Ga I 287.4 nm emission line was determined to be superior for the purposes of Ga detection and concentration determination.A limit of detection below 0.25% was achieved using a multivariate regression model of the Ga I287.4 nm line ratio versus two separate Ce II emission lines. This LOD is considered a conservative estimation of technique’s capability given the type of the calibration samples available and low power( 5 mJ per 1 ns pulse) and resolving power (λ/∆λ= 4000) of this handheld device. Nonetheless, the utility of the technique is demonstrated via a detailed mapping analysis of the surface Ga distribution of a Ce-Ga sample which reveals significant heterogeneity resulting from the sample production process.
- Open Access
- 12 December 2017
- Published by Optica Publishing Group in Applied Optics
- Vol. 56 (36) , 9868-9875
Detection of uranyl fluoride and sand surface contamination on metal substrates by hand-held laser-induced breakdown spectroscopy
A hand-held device for laser-induced breakdown spectroscopy has been investigated for the determination of uranyl fluoride surface contamination. This research demonstrates the ability to successfully detect uranium on surfaces when using a low resolving power (λ/Δλ=4000) spectrograph, with a 5 mJ energy per 1 ns pulsed laser radiation, available as a commercially packaged hand-held system. Sand/uranyl fluoride mixtures are prepared to simulate residue likely encountered during decontamination efforts at facilities that handle uranium hexafluoride. Detection limits are described for four uranium lines with one revealing the capability to detect uranium at a level of 250 parts per million. Advantages of the studied compact device include that location specific information can be obtained on-site to augment contamination identification.
- 12 December 2017
- Published by Optica Publishing Group in Applied Optics
- Vol. 56 (36) , 9868-9875
Open AccessDetection of uranyl fluoride and sand surface contamination on metal substrates by hand-held laser-induced breakdown spectroscopy
A hand-held device for laser-induced breakdown spectroscopy has been investigated for the determination of uranyl fluoride surface contamination. This research demonstrates the ability to successfully detect uranium on surfaces when using a low resolving power (λ/Δλ=4000) spectrograph, with a 5 mJ energy per 1 ns pulsed laser radiation, available as a commercially packaged hand-held system. Sand/uranyl fluoride mixtures are prepared to simulate residue likely encountered during decontamination efforts at facilities that handle uranium hexafluoride. Detection limits are described for four uranium lines with one revealing the capability to detect uranium at a level of 250 parts per million. Advantages of the studied compact device include that location specific information can be obtained on-site to augment contamination identification.
- 7 October 2017
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 314 (3) , 2349-2355
Production and characterization of synthetic urban nuclear melt glass
- 7 October 2017
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 314 (3) , 2349-2355
Production and characterization of synthetic urban nuclear melt glass
- 1 May 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (05) , C05014
Germanium CCDs for large-format SWIR and X-ray imaging
- 1 May 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (05) , C05014
Germanium CCDs for large-format SWIR and X-ray imaging
- 20 June 2015
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 307 (1) , 259-267
A comparison of gamma spectra from trinitite versus irradiated synthetic nuclear melt glass
- 20 June 2015
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 307 (1) , 259-267
A comparison of gamma spectra from trinitite versus irradiated synthetic nuclear melt glass
- 21 March 2015
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 306 (1) , 175-181
Compositional planning for development of synthetic urban nuclear melt glass
- 21 March 2015
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 306 (1) , 175-181
Compositional planning for development of synthetic urban nuclear melt glass
- Open Access
- 20 January 2015
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 304 (3) , 1293-1301
Development of synthetic nuclear melt glass for forensic analysis
A method for producing synthetic debris similar to the melt glass produced by nuclear surface testing is demonstrated. Melt glass from the first nuclear weapon test (commonly referred to as trinitite) is used as the benchmark for this study. These surrogates can be used to simulate a variety of scenarios and will serve as a tool for developing and validating forensic analysis methods.
- 20 January 2015
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 304 (3) , 1293-1301
Open AccessDevelopment of synthetic nuclear melt glass for forensic analysis
A method for producing synthetic debris similar to the melt glass produced by nuclear surface testing is demonstrated. Melt glass from the first nuclear weapon test (commonly referred to as trinitite) is used as the benchmark for this study. These surrogates can be used to simulate a variety of scenarios and will serve as a tool for developing and validating forensic analysis methods.