Matthew B. Crist
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Matthew B. Crist has a total of 93 co-authors. Here are the top co-authors by number of shared publications:
Kiran M. Perkins
Division of Healthcare Quality Promotion, National Center for Emerging and Zoonotic Infectious Diseases, CDC, Atlanta, GA
3 shared publications- Azaibi Tamin
COVID-19 Response, Centers for Disease Control and Prevention, Atlanta, Georgia, USA
2 shared publications - Cara Bicking Kinsey
Bureau of Epidemiology, Pennsylvania Department of Health, Harrisburg, Pennsylvania
2 shared publications Channyn Williams
DC Public Health Laboratory, Washington, DC
2 shared publicationsGemma Parra
Division of Healthcare Quality Promotion, Centers for Disease Control and Prevention (CDC), Atlanta, GA
2 shared publicationsHeather Moulton-Meissner
Division of Healthcare Quality Promotion, Centers for Disease Control and Prevention, Atlanta, Georgia
2 shared publications
Latest Publications
- 5 August 2024
- Published by Elsevier in American Journal of Infection Control
- Vol. 53 (2) , 277-278
Oral care in nonventilated hospitalized patients
- 5 August 2024
- Published by Elsevier in American Journal of Infection Control
- Vol. 53 (2) , 277-278
Oral care in nonventilated hospitalized patients
- 8 September 2022
- Published by Wolters Kluwer Health in Journal of Public Health Management & Practice
- Vol. 28 (6) , 682-692
Evaluation of a Virtual Training to Enhance Public Health Capacity for COVID-19 Infection Prevention and Control in Nursing Homes
Context: Between April 2020 and May 2021, the Centers for Disease Control and Prevention (CDC) awarded more than $40 billion to health departments nationwide for COVID-19 prevention and response activities. One of the identified priorities for this investment was improving infection prevention and control (IPC) in nursing homes. Program: CDC developed a virtual course to train new and less experienced public health staff in core healthcare IPC principles and in the application of CDC COVID-19 healthcare IPC guidance for nursing homes. Implementation: From October 2020 to August 2021, the CDC led training sessions for 12 cohorts of public health staff using pretraining reading materials, case-based scenarios, didactic presentations, peer-learning opportunities, and subject matter expert–led discussions. Multiple electronic assessments were distributed to learners over time to measure changes in self-reported knowledge and confidence and to collect feedback on the course. Participating public health programs were also assessed to measure overall course impact. Evaluation: Among 182 enrolled learners, 94% completed the training. Most learners were infection preventionists (42%) or epidemiologists (38%), had less than 1 year of experience in their health department role (75%), and had less than 1 year of subject matter experience (54%). After training, learners reported increased knowledge and confidence in applying the CDC COVID-19 healthcare IPC guidance for nursing homes (≥81%) with the greatest increase in performing COVID-19 IPC consultations and assessments (87%). The majority of participating programs agreed that the course provided an overall benefit (88%) and reduced training burden (72%). Discussion: The CDC's virtual course was effective in increasing public health capacity for COVID-19 healthcare IPC in nursing homes and provides a possible model to increase IPC capacity for other infectious diseases and other healthcare settings. Future virtual healthcare IPC courses could be enhanced by tailoring materials to health department needs, reinforcing training through applied learning experiences, and supporting mechanisms to retain trained staff.
- 8 September 2022
- Published by Wolters Kluwer Health in Journal of Public Health Management & Practice
- Vol. 28 (6) , 682-692
Evaluation of a Virtual Training to Enhance Public Health Capacity for COVID-19 Infection Prevention and Control in Nursing Homes
Context: Between April 2020 and May 2021, the Centers for Disease Control and Prevention (CDC) awarded more than $40 billion to health departments nationwide for COVID-19 prevention and response activities. One of the identified priorities for this investment was improving infection prevention and control (IPC) in nursing homes. Program: CDC developed a virtual course to train new and less experienced public health staff in core healthcare IPC principles and in the application of CDC COVID-19 healthcare IPC guidance for nursing homes. Implementation: From October 2020 to August 2021, the CDC led training sessions for 12 cohorts of public health staff using pretraining reading materials, case-based scenarios, didactic presentations, peer-learning opportunities, and subject matter expert–led discussions. Multiple electronic assessments were distributed to learners over time to measure changes in self-reported knowledge and confidence and to collect feedback on the course. Participating public health programs were also assessed to measure overall course impact. Evaluation: Among 182 enrolled learners, 94% completed the training. Most learners were infection preventionists (42%) or epidemiologists (38%), had less than 1 year of experience in their health department role (75%), and had less than 1 year of subject matter experience (54%). After training, learners reported increased knowledge and confidence in applying the CDC COVID-19 healthcare IPC guidance for nursing homes (≥81%) with the greatest increase in performing COVID-19 IPC consultations and assessments (87%). The majority of participating programs agreed that the course provided an overall benefit (88%) and reduced training burden (72%). Discussion: The CDC's virtual course was effective in increasing public health capacity for COVID-19 healthcare IPC in nursing homes and provides a possible model to increase IPC capacity for other infectious diseases and other healthcare settings. Future virtual healthcare IPC courses could be enhanced by tailoring materials to health department needs, reinforcing training through applied learning experiences, and supporting mechanisms to retain trained staff.
- Top Cited PapersOpen Access
- 20 May 2022
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 43 (6) , 687-713
Strategies to prevent ventilator-associated pneumonia, ventilator-associated events, and nonventilator hospital-acquired pneumonia in acute-care hospitals: 2022 Update
The purpose of this document is to highlight practical recommendations to assist acute care hospitals to prioritize and implement strategies to prevent ventilator-associated pneumonia (VAP), ventilator-associated events (VAE), and non-ventilator hospital-acquired pneumonia (NV-HAP) in adults, children, and neonates. This document updates the Strategies to Prevent Ventilator-Associated Pneumonia in Acute Care Hospitals published in 2014. This expert guidance document is sponsored by the Society for Healthcare Epidemiology (SHEA), and is the product of a collaborative effort led by SHEA, the Infectious Diseases Society of America, the American Hospital Association, the Association for Professionals in Infection Control and Epidemiology, and The Joint Commission, with major contributions from representatives of a number of organizations and societies with content expertise.
- 20 May 2022
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 43 (6) , 687-713
Top Cited PapersOpen AccessStrategies to prevent ventilator-associated pneumonia, ventilator-associated events, and nonventilator hospital-acquired pneumonia in acute-care hospitals: 2022 Update
The purpose of this document is to highlight practical recommendations to assist acute care hospitals to prioritize and implement strategies to prevent ventilator-associated pneumonia (VAP), ventilator-associated events (VAE), and non-ventilator hospital-acquired pneumonia (NV-HAP) in adults, children, and neonates. This document updates the Strategies to Prevent Ventilator-Associated Pneumonia in Acute Care Hospitals published in 2014. This expert guidance document is sponsored by the Society for Healthcare Epidemiology (SHEA), and is the product of a collaborative effort led by SHEA, the Infectious Diseases Society of America, the American Hospital Association, the Association for Professionals in Infection Control and Epidemiology, and The Joint Commission, with major contributions from representatives of a number of organizations and societies with content expertise.
- 20 May 2022
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 44 (5) , 809-812
Characteristics of nursing home residents and healthcare personnel with repeated severe acute respiratory coronavirus virus 2 (SARS-CoV-2) tests positive ≥90 days after initial infection: Four US jurisdictions, July 2020–March 2021
One in six nursing home residents and staff with positive SARS-CoV-2 tests ≥90 days after initial infection had specimen cycle thresholds (Ct) <30. Individuals with specimen Ct<30 were more likely to report symptoms but were not different from individuals with high Ct value specimens by other clinical and testing data.
- 20 May 2022
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 44 (5) , 809-812
Characteristics of nursing home residents and healthcare personnel with repeated severe acute respiratory coronavirus virus 2 (SARS-CoV-2) tests positive ≥90 days after initial infection: Four US jurisdictions, July 2020–March 2021
One in six nursing home residents and staff with positive SARS-CoV-2 tests ≥90 days after initial infection had specimen cycle thresholds (Ct) <30. Individuals with specimen Ct<30 were more likely to report symptoms but were not different from individuals with high Ct value specimens by other clinical and testing data.
- Open Access
- 4 December 2021
- Published by Oxford University Press (OUP) in Open Forum Infectious Diseases
- Vol. 8 (Supplement) , S298-S299
393. Characteristics of SARS-CoV-2 RNA Viral Loads among Nursing Home Residents and Staff with Repeat Positive Tests ≥ 90 Days After Initial Infection: 5 US Jurisdictions, July 2020–March 2021
Background. Understanding the viral load and potential infectivity of individuals in nursing homes (NH) with repeat positive SARS-CoV-2 tests ≥ 90 days after initial infection has important implications for safety related to transmission in this high-risk setting. Methods. We collected epidemiologic data by reviewing records of a convenience sample of NH residents and staff with respiratory specimens who had positive SARS-CoV-2 rRT-PCR test results from July 2020 through March 2021 and had a SARS-CoV-2 infection diagnosed ≥ 90 days prior. No fully vaccinated individuals were included. Each contributed one repeat positive specimen ≥ 90 days after initial, which was sent to CDC and retested using rRT-PCR. Specimens were assessed for replication-competent virus in cell culture if Cycle threshold (Ct) < 34 and sequenced if Ct < 30. Using Ct values as a proxy for viral RNA load, specimens were categorized as high (Ct < 30) or low (if Ct ≥ 30 or rRT-PCR negative at retesting). Continuous variables were compared using Wilcoxon signed-rank tests. Proportions were compared using Chi-squared or Fisher’s exact tests. Results. Of 64 unvaccinated individuals with specimens from 61 unique NHs, 14 (22%) were sent for culture and sequencing. Ten of 64 (16%) had a high viral RNA load, of which four (6%) were culture positive and none were known variants of interest or concern (Figure 1). Median days to repeat positive test result were 122 (Interquartile range (IQR): 103–229) and 201 (IQR: 139–254), respectively, for high versus low viral load specimens (p=0.13). More individuals with high viral loads (5/10, 50%) reported COVID-19 symptoms than with a low viral load (1/27, 4%, p=0.003). Most individuals (46/58, 79%) were tested following known or suspected exposures, with no significant differences between high and low viral load (p=0.18). In this study, nearly 1 in 6 NH residents and staff with repeat positive tests after 90 days demonstrated high viral RNA loads and viable virus, indicating possible infectivity. While individuals with high RNA viral load may be more likely to be symptomatic, distinguishing asymptomatic individuals who have high viral loads may be difficult with timing since initial infection, other test results, or exposure history alone. John A. Jernigan, MD, MS, Nothing to disclose.
- 4 December 2021
- Published by Oxford University Press (OUP) in Open Forum Infectious Diseases
- Vol. 8 (Supplement) , S298-S299
Open Access393. Characteristics of SARS-CoV-2 RNA Viral Loads among Nursing Home Residents and Staff with Repeat Positive Tests ≥ 90 Days After Initial Infection: 5 US Jurisdictions, July 2020–March 2021
Background. Understanding the viral load and potential infectivity of individuals in nursing homes (NH) with repeat positive SARS-CoV-2 tests ≥ 90 days after initial infection has important implications for safety related to transmission in this high-risk setting. Methods. We collected epidemiologic data by reviewing records of a convenience sample of NH residents and staff with respiratory specimens who had positive SARS-CoV-2 rRT-PCR test results from July 2020 through March 2021 and had a SARS-CoV-2 infection diagnosed ≥ 90 days prior. No fully vaccinated individuals were included. Each contributed one repeat positive specimen ≥ 90 days after initial, which was sent to CDC and retested using rRT-PCR. Specimens were assessed for replication-competent virus in cell culture if Cycle threshold (Ct) < 34 and sequenced if Ct < 30. Using Ct values as a proxy for viral RNA load, specimens were categorized as high (Ct < 30) or low (if Ct ≥ 30 or rRT-PCR negative at retesting). Continuous variables were compared using Wilcoxon signed-rank tests. Proportions were compared using Chi-squared or Fisher’s exact tests. Results. Of 64 unvaccinated individuals with specimens from 61 unique NHs, 14 (22%) were sent for culture and sequencing. Ten of 64 (16%) had a high viral RNA load, of which four (6%) were culture positive and none were known variants of interest or concern (Figure 1). Median days to repeat positive test result were 122 (Interquartile range (IQR): 103–229) and 201 (IQR: 139–254), respectively, for high versus low viral load specimens (p=0.13). More individuals with high viral loads (5/10, 50%) reported COVID-19 symptoms than with a low viral load (1/27, 4%, p=0.003). Most individuals (46/58, 79%) were tested following known or suspected exposures, with no significant differences between high and low viral load (p=0.18). In this study, nearly 1 in 6 NH residents and staff with repeat positive tests after 90 days demonstrated high viral RNA loads and viable virus, indicating possible infectivity. While individuals with high RNA viral load may be more likely to be symptomatic, distinguishing asymptomatic individuals who have high viral loads may be difficult with timing since initial infection, other test results, or exposure history alone. John A. Jernigan, MD, MS, Nothing to disclose.
- 6 October 2021
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 43 (10) , 1333-1338
Mycobacterium chimaera infections among cardiothoracic surgery patients associated with heater-cooler devices—Kansas and California, 2019
Background: In 2015, an international outbreak of Mycobacterium chimaera infections among patients undergoing cardiothoracic surgeries was associated with exposure to contaminated LivaNova 3T heater-cooler devices (HCDs). From June 2017 to October 2020, the Centers for Disease Control and Prevention was notified of 18 patients with M. chimaera infections who had undergone cardiothoracic surgeries at 2 hospitals in Kansas (14 patients) and California (4 patients); 17 had exposure to 3T HCDs. Whole-genome sequencing of the clinical and environmental isolates matched the global outbreak strain identified in 2015.Methods: Investigations were conducted at each hospital to determine the cause of ongoing infections. Investigative methods included query of microbiologic records to identify additional cases, medical chart review, observations of operating room setup, HCD use and maintenance practices, and collection of HCD and environmental samples.Results: Onsite observations identified deviations in the positioning and maintenance of the 3T HCDs from the US Food and Drug Administration (FDA) recommendations and the manufacturer’s updated cleaning and disinfection protocols. Additionally, most 3T HCDs had not undergone the recommended vacuum and sealing upgrades by the manufacturer to decrease the dispersal of M. chimaera–containing aerosols into the operating room, despite hospital requests to the manufacturer.Conclusions: These findings highlight the need for continued awareness of the risk of M. chimaera infections associated with 3T HCDs, even if the devices are newly manufactured. Hospitals should maintain vigilance in adhering to FDA recommendations and the manufacturer’s protocols and in identifying patients with potential M. chimaera infections with exposure to these devices.
- 6 October 2021
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 43 (10) , 1333-1338
Mycobacterium chimaera infections among cardiothoracic surgery patients associated with heater-cooler devices—Kansas and California, 2019
Background: In 2015, an international outbreak of Mycobacterium chimaera infections among patients undergoing cardiothoracic surgeries was associated with exposure to contaminated LivaNova 3T heater-cooler devices (HCDs). From June 2017 to October 2020, the Centers for Disease Control and Prevention was notified of 18 patients with M. chimaera infections who had undergone cardiothoracic surgeries at 2 hospitals in Kansas (14 patients) and California (4 patients); 17 had exposure to 3T HCDs. Whole-genome sequencing of the clinical and environmental isolates matched the global outbreak strain identified in 2015.Methods: Investigations were conducted at each hospital to determine the cause of ongoing infections. Investigative methods included query of microbiologic records to identify additional cases, medical chart review, observations of operating room setup, HCD use and maintenance practices, and collection of HCD and environmental samples.Results: Onsite observations identified deviations in the positioning and maintenance of the 3T HCDs from the US Food and Drug Administration (FDA) recommendations and the manufacturer’s updated cleaning and disinfection protocols. Additionally, most 3T HCDs had not undergone the recommended vacuum and sealing upgrades by the manufacturer to decrease the dispersal of M. chimaera–containing aerosols into the operating room, despite hospital requests to the manufacturer.Conclusions: These findings highlight the need for continued awareness of the risk of M. chimaera infections associated with 3T HCDs, even if the devices are newly manufactured. Hospitals should maintain vigilance in adhering to FDA recommendations and the manufacturer’s protocols and in identifying patients with potential M. chimaera infections with exposure to these devices.
- Open Access
- 10 March 2017
- Published by Centers for Disease Control MMWR Office in MMWR. Morbidity and Mortality Weekly Report
- Vol. 66 (9) , 258-260
Notes from the Field: Hepatitis C Transmission from Inappropriate Reuse of Saline Flush Syringes for Multiple Patients in an Acute Care General Hospital — Texas, 2015
- 10 March 2017
- Published by Centers for Disease Control MMWR Office in MMWR. Morbidity and Mortality Weekly Report
- Vol. 66 (9) , 258-260
Open AccessNotes from the Field: Hepatitis C Transmission from Inappropriate Reuse of Saline Flush Syringes for Multiple Patients in an Acute Care General Hospital — Texas, 2015