RARochelle Ade

Rochelle Ade

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rochelle Ade has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Thermal Comfort, Overheating, and Health in Residential Buildings

    by Rochelle Ade, Michael Rehm

    Thermal comfort, overheating, underheating, and indoor humidity are critical determinants of health and wellbeing in residential buildings, particularly for older adults who exhibit heightened vulnerability to thermal extremes. This study develops and applies an integrated post-occupancy evaluation framework combining adaptive comfort modelling (EN 16798-1 [5]), overheating assessment (CIBSE TM59 [6] and Passivhaus criteria), health-based temperature thresholds, and humidity risk screening in a 40-unit apartment building for residents aged 65 and older in Auckland, New Zealand. Indoor environmental monitoring and comfort surveys were analysed across two consecutive summers and a winter period. The analysis identified widespread summertime overheating, particularly at night; extensive winter cold exposure below health thresholds; persistent high indoor humidity; and a systematic divergence between modelled compliance and subjective thermal perception. Across 2,083 matched survey–environment records, 52.4% of occupants reported hot thermal sensation while the EN 16798-1 [5] Category I adaptive model classified only 0.8% of the same hours as exceeding the upper comfort limit. The divergence persisted across seasons: in two summers, reported overheating exceeded modelled overheating by 72.2 and 63.5 percentage points respectively; in winter, 26.5% of occupants reported hot sensation against 0.2% of matched hours classified as hot. Running mean outdoor temperature was the dominant predictor of overheating risk. Current assessment frameworks inadequately capture the combined thermal exposure and health risks of older occupants; adaptive comfort models systematically underestimate heat-related discomfort in populations with limited thermoregulatory capacity, highlighting the need for population-specific thresholds in later-life housing.

  • Open Access

    What is drier? Understanding humidity in green‐certified dwellings: a winter case study from Auckland, New Zealand

    by Rochelle Ade, Michael Rehm, Vishnupriya Vishnupriya

    Despite the growing emphasis on green‐certified buildings, there remains a notable gap in understanding their humidity performance, particularly in residential settings. This study addresses this gap by evaluating the wintertime humidity performance of 40 subsidised, 7‐Homestar certified apartments for older residents in Auckland, New Zealand. While current building science guidelines recommend an optimal relative humidity (RH) range of 40% to 60%, our results show frequent exceedances of this range. However, when assessed using absolute humidity (AH), the apartments consistently fell within the epidemiologically acceptable range of 8–14 g/kg. This discrepancy highlights the need to reconsider which humidity metric—RH or AH—better reflects acceptable indoor environmental quality for health and comfort. Resident feedback indicated satisfaction with indoor humidity levels, despite elevated RH. This study calls for a reassessment of humidity guidelines in green‐certified buildings to better balance occupant health, comfort, and energy efficiency.


  • Open Access

    How cold is too cold? Getting home temperatures right

    by Rochelle Ade

    Policies worldwide focus on heating homes to a minimum temperature that has no evidence to support it. They cause vulnerable people needless distress. When the World Health Organization (WHO) set out to review what living in a cold building meant for our health its researchers were perplexed. Back in 1987, the WHO recommended indoor temperatures […]

  • A summertime thermal analysis of New Zealand Homestar certified apartments for older people

    by Rochelle Ade, Michael Rehm

    It is recognized that as humans age, their ability to withstand high or low temperatures reduces. Temperature extremes can also worsen chronic conditions, including cardiovascular, respiratory and other health issues. This study analyses 40 apartments in a single building in Auckland, New Zealand to determine whether the newly designed and constructed apartment, specifically for retirees, is delivering a suitable thermal interior environment during the warmest months of the year. Despite holding this green certification and meeting specific requirements to achieve cooling points that are meant to reduce the likelihood of overheating, the building exhibits significant signs of overheating in the two warmest months of the year (January and February) with two-thirds of apartments failing the CIBSE TM59 overheating criteria. The summertime performance of this green-rated building crucial insights for design professionals policymakers and developers of green building rating tools.


  • Retracted

    RETRACTED ARTICLE: A summertime thermal analysis of certified green apartments for older people

    by Rochelle Ade, Michael Rehm

    It is recognized that as humans age, their ability to withstand high or low temperatures reduces. Temperature extremes can also worsen chronic conditions, including cardiovascular, respiratory, and other health issues. This study analyses 40 apartments in a single building in Auckland, New Zealand to determine whether the newly designed and constructed apartment, specifically for retirees, is delivering a suitable thermal interior environment during the warmest months of the year. Despite holding this green certification and meeting specific requirements to achieve cooling points that are meant to reduce the likelihood of overheating, the building exhibits significant signs of overheating in the two warmest months of the year (January and February) with two-thirds of apartments failing the CIBSE TM59 overheating criteria. The summertime performance of this green-rated building crucial insights for design professionals policymakers and developers of green building rating tools.

  • Is green certification the solution to substandard indoor air quality (humidity)? A case study of old, new and green-certified dwellings

    by Rochelle Ade, Michael Rehm

    New Zealand is hamstrung by a housing crisis. Although the discourse primarily focuses on housing affordability and homelessness, there is a more pervasive problem afflicting New Zealanders: that New Zealand homes are substandard, being cold, damp and difficult to heat. This article reviews the moisture levels of three categories of housing (older vintage, newly constructed and newly constructed green certified) in Auckland, New Zealand, to determine whether the pervasive issue of high internal humidity in housing can be successfully rectified through using a green building certification. The results show that newly constructed 6-Homestar dwellings are in the optimal relative humidity range mean 14 per cent of time in contrast to 17 per cent for new code-compliant dwellings (and six per cent for older vintage dwellings) in the damp winter months of June through August. This research documents that a particular green certification – 6-Homestar – may not deliver suitable humidity control, and that alternative certifications that stipulate airtightness levels and require active ventilation – such as Passive House – could be considered by policy makers interested in delivering low-carbon, warm, dry houses in New Zealand.


  • Open Access

    AT WHAT COST? AN ANALYSIS OF THE GREEN COST PREMIUM TO ACHIEVE 6-HOMESTAR IN NEW ZEALAND

    by Rochelle Ade, Michael Rehm

    In the green building industry there is an implicit understanding that the use of a green building rating tool will attract additional capital cost. This phenomenon has been well studied in commercial buildings, with mixed results, but has received little focus in the residential, single family context. In New Zealand the local green building council advises the market that they have reduced the time and cost to implement their green building rating tool, Homestar, through modifications to version 4 of the rating tool, which include the use of a new 6-Homestar checklist. This research investigates this claim using a comparative cost methodology to determine the potential additional capital cost commitment that would be required to achieve a 6-Homestar certification, utilising ten standalone and terraced house designs from the Hobsonville Point development in Auckland, NZ. This research determines that there is an additional cost to achieve 6-Homestar of 3–5%. This is nearly double compared to previous research into Homestar and also finds that, for the houses reviewed, the use of the 6-Homestar checklist is less cost effective than other options. Therefore, in this instance the advice and guidance of the green building council is erroneous and misleading to the market.


  • Summertime comparative evaluation of indoor temperature and comfort in Auckland New Zealand: a survey of green certified, code and older homes

    by Rochelle Ade, Michael Rehm

    A frequently stated hallmark of certified green homes is that they are ‘healthier’ and provide superior thermal comfort. This usually requires increasing insulation levels from code requirements on the understanding that this will provide a warmer, drier internal environment. However this solution to ‘cold and damp’ housing may have unintended consequences; while highly insulated dwellings may be warm over the winter, are they still comfortable during warmest months? This study analyses 29 dwellings in Auckland, New Zealand to determine if there is any difference in the temperature and thermal comfort between three types of dwellings: newly built green certified (6-Homestar), newly built non-certified and old dwellings (pre-1978). The results show large differences between dwelling categories with the certified 6-Homestar dwellings exceeding the World Health Organisation (WHO) healthy temperature threshold 75% of the time during the warmest months of the year, resulting in predicted occupant discomfort 16% of the time. These results have significant policy implications with it apparent that not only under-heating but also overheating require specific attention in government legislation, green building rating tools and building codes.