Jovica Atanackovic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jovica Atanackovic has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Witold Matysiak
Ohio State University Health System
4 shared publications J. Dubeau
DETEC, Gatineau, QC, Canada J8 T 4J1
3 shared publications- Jacques Dubeau
DETEC, Gatineau, QC, Canada
3 shared publications A. J. Waker
University of Ontario Institute of Technology, Oshawa, ON, Canada L1H 7K4
2 shared publicationsA. Yonkeu
Atomic Energy of Canada Limited, Chalk River Laboratories, Chalk River, ONT, Canada K0J 1J0
2 shared publicationsA.R. Hanu
Bruce Power, Tiverton, ON, N0G 2T0, Canada; McMaster University, Department of Physics and Astronomy, Hamilton, ON, L8S 4L8, Canada
2 shared publications
Latest Publications
- Open Access
- 1 November 2021
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 177, 109902
Eye lens dosimetry in Canadian CANDU nuclear power plants based on operational dosimetric quantities H(10) and H(0.07)- 1 November 2021
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 177, 109902
Open AccessEye lens dosimetry in Canadian CANDU nuclear power plants based on operational dosimetric quantities H(10) and H(0.07) - 1 August 2021
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 174, 109746
Quantification of pure beta spectra in mixed beta gamma fields as part of eye lens dosimetry at CANDU power plants
- 1 August 2021
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 174, 109746
Quantification of pure beta spectra in mixed beta gamma fields as part of eye lens dosimetry at CANDU power plants
- 1 January 2021
- Published by Elsevier in Radiation Measurements
- Vol. 140
A study on the use of modified extremity dosemeters for the measurement of H(3,α)
- 1 January 2021
- Published by Elsevier in Radiation Measurements
- Vol. 140
A study on the use of modified extremity dosemeters for the measurement of H(3,α)
- 15 December 2020
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 192 (3) , 309-320
CHARACTERIZATION OF A LANTHANUM BROMIDE DETECTOR FOR EYE LENS DOSIMETRY AT THE CANDU NUCLEAR POWER PLANTS BASED ON DIRECT MEASUREMENTS OF THE GAMMA-RAY SPECTRA
Gamma-ray spectra were measured using a LaBr$_{3}$(Ce) spectrometer during the outage periods, aiming at quantifying the gamma source term of radiation workers’ exposure, at the CANDU nuclear power reactors, for the purposes of eye lens dosimetry. The spectra were measured inside the boiler rooms, of the Bruce Power and Ontario Power Generation (OPG) CANDU nuclear power plants, where workers are exposed to relatively high dose rates radiation fields during the maintenance work. Prior to measurements at the CANDU reactors, the pulse shaping parameters of the gamma spectrometer were optimised for high rates gamma fields, up to an input rates of 120 kcps, in order to accomplish a high output rate with a reasonable energy resolution. In parallel, the response of the LaBr$_{3}$(Ce) detector was characterized by experiments and Monte Carlo simulations. The gamma spectra measured at the CANDU reactors were reported in terms of the gamma-ray fluence rate spectrum. In all measured data, $^{60}$Co and $^{95}$Nb were main contributors of the gamma fields. The measured spectra have been used to calculate the dosimetric quantities of interest: personal dose equivalents H$_{p}$(10) and H$_{p}$(0.07) and eye lens absorbed dose.
- 15 December 2020
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 192 (3) , 309-320
CHARACTERIZATION OF A LANTHANUM BROMIDE DETECTOR FOR EYE LENS DOSIMETRY AT THE CANDU NUCLEAR POWER PLANTS BASED ON DIRECT MEASUREMENTS OF THE GAMMA-RAY SPECTRA
Gamma-ray spectra were measured using a LaBr$_{3}$(Ce) spectrometer during the outage periods, aiming at quantifying the gamma source term of radiation workers’ exposure, at the CANDU nuclear power reactors, for the purposes of eye lens dosimetry. The spectra were measured inside the boiler rooms, of the Bruce Power and Ontario Power Generation (OPG) CANDU nuclear power plants, where workers are exposed to relatively high dose rates radiation fields during the maintenance work. Prior to measurements at the CANDU reactors, the pulse shaping parameters of the gamma spectrometer were optimised for high rates gamma fields, up to an input rates of 120 kcps, in order to accomplish a high output rate with a reasonable energy resolution. In parallel, the response of the LaBr$_{3}$(Ce) detector was characterized by experiments and Monte Carlo simulations. The gamma spectra measured at the CANDU reactors were reported in terms of the gamma-ray fluence rate spectrum. In all measured data, $^{60}$Co and $^{95}$Nb were main contributors of the gamma fields. The measured spectra have been used to calculate the dosimetric quantities of interest: personal dose equivalents H$_{p}$(10) and H$_{p}$(0.07) and eye lens absorbed dose.
- Open Access
- 1 June 2016
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 820, 40-47
Use of GEANT4 vs. MCNPX for the characterization of a boron-lined neutron detector
- 1 June 2016
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 820, 40-47
Open AccessUse of GEANT4 vs. MCNPX for the characterization of a boron-lined neutron detector
- 1 May 2015
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 99, 122-132
Characterization of neutron fields from bare and heavy water moderated 252Cf spontaneous fission source using Bonner Sphere Spectrometer
- 1 May 2015
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 99, 122-132
Characterization of neutron fields from bare and heavy water moderated 252Cf spontaneous fission source using Bonner Sphere Spectrometer
- 16 January 2014
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 161 (1-4) , 269-273
Monte Carlo calculations of lung dose in ORNL phantom for boron neutron capture therapy
Monte Carlo simulations were performed to evaluate dose for possible treatment of cancers by boron neutron capture therapy (BNCT). The computational model of male Oak Ridge National Laboratory (ORNL) phantom was used to simulate tumours in the lung. Calculations have been performed by means of the MCNP5/X code. In this simulation, two opposite neutron beams were considered, in order to obtain uniform neutron flux distribution inside the lung. The obtained results indicate that the lung cancer could be treated by BNCT under the assumptions of calculations.
- 16 January 2014
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 161 (1-4) , 269-273
Monte Carlo calculations of lung dose in ORNL phantom for boron neutron capture therapy
Monte Carlo simulations were performed to evaluate dose for possible treatment of cancers by boron neutron capture therapy (BNCT). The computational model of male Oak Ridge National Laboratory (ORNL) phantom was used to simulate tumours in the lung. Calculations have been performed by means of the MCNP5/X code. In this simulation, two opposite neutron beams were considered, in order to obtain uniform neutron flux distribution inside the lung. The obtained results indicate that the lung cancer could be treated by BNCT under the assumptions of calculations.
- 6 December 2013
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 161 (1-4) , 216-220
Correction and verification of AECL Bonner Sphere response matrix based on mono-energetic neutron calibration performed at NPL
The AECL Bonner Sphere Spectrometer (BSS) was taken to National Physical Laboratory (NPL) for calibration in mono-energetic neutron fields and bare 252Cf neutron fields. The mono-energetic radiations were performed using ISO-8529 prescribed neutron energies: 0.071, 0.144, 0.565, 1.2, 5 and 17 MeV. A central SP9 proportional counter was also evaluated at the NPL thermal neutron calibration facility in order to assess an effective pressure of 3He inside the counter, i.e. number density of 3He atoms. Based on these measurements and methods outlined by Thomas and Soochak, a new BSS response matrix was generated. The response matrix is then verified by unfolding spectra corresponding to various neutron fields. Those are NPL bare 252Cf source, National Institute of Standards and Technology bare and heavy water moderated 252Cf source and 241AmBe calibration source located at National Research Council. A good agreement was observed with expected neutron fluence rates, as well as derived dosimetric quantities, such as International Commission on Radiological Protection-74 ambient dose equivalent.
- 6 December 2013
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 161 (1-4) , 216-220
Correction and verification of AECL Bonner Sphere response matrix based on mono-energetic neutron calibration performed at NPL
The AECL Bonner Sphere Spectrometer (BSS) was taken to National Physical Laboratory (NPL) for calibration in mono-energetic neutron fields and bare 252Cf neutron fields. The mono-energetic radiations were performed using ISO-8529 prescribed neutron energies: 0.071, 0.144, 0.565, 1.2, 5 and 17 MeV. A central SP9 proportional counter was also evaluated at the NPL thermal neutron calibration facility in order to assess an effective pressure of 3He inside the counter, i.e. number density of 3He atoms. Based on these measurements and methods outlined by Thomas and Soochak, a new BSS response matrix was generated. The response matrix is then verified by unfolding spectra corresponding to various neutron fields. Those are NPL bare 252Cf source, National Institute of Standards and Technology bare and heavy water moderated 252Cf source and 241AmBe calibration source located at National Research Council. A good agreement was observed with expected neutron fluence rates, as well as derived dosimetric quantities, such as International Commission on Radiological Protection-74 ambient dose equivalent.
- 1 December 2013
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 161 (1-4) , 221-224
Measurements of neutron energy spectra from 7Li(p,n)7Be reaction with Bonner sphere spectrometer, Nested Neutron Spectrometer and ROSPEC
Neutron spectrometry measurements were carried out at the McMaster Accelerator Laboratory (MAL), which is equipped with a 3-MV Van de Graaff-type accelerator. Protons were accelerated onto a thick natural lithium target inducing the 7Li(p,n)7Be threshold reaction. Depending on the proton energy, slightly different poly-energetic neutron fields were produced. Neutron spectra were measured at two incident proton energies: 2.15 and 2.24 MeV, which produced poly-energetic neutrons with maximum kinetic energies of 401 and 511 keV, respectively. Measurements were performed at a distance of 1.5 m from the target in the forward direction with three different instruments: Bonner sphere spectrometer, Nested Neutron Spectrometer and ROtational proton recoil SPECtrometer.
- 1 December 2013
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 161 (1-4) , 221-224
Measurements of neutron energy spectra from 7Li(p,n)7Be reaction with Bonner sphere spectrometer, Nested Neutron Spectrometer and ROSPEC
Neutron spectrometry measurements were carried out at the McMaster Accelerator Laboratory (MAL), which is equipped with a 3-MV Van de Graaff-type accelerator. Protons were accelerated onto a thick natural lithium target inducing the 7Li(p,n)7Be threshold reaction. Depending on the proton energy, slightly different poly-energetic neutron fields were produced. Neutron spectra were measured at two incident proton energies: 2.15 and 2.24 MeV, which produced poly-energetic neutrons with maximum kinetic energies of 401 and 511 keV, respectively. Measurements were performed at a distance of 1.5 m from the target in the forward direction with three different instruments: Bonner sphere spectrometer, Nested Neutron Spectrometer and ROtational proton recoil SPECtrometer.