CHARACTERIZATION OF A LANTHANUM BROMIDE DETECTOR FOR EYE LENS DOSIMETRY AT THE CANDU NUCLEAR POWER PLANTS BASED ON DIRECT MEASUREMENTS OF THE GAMMA-RAY SPECTRA
Authors:
- 15 December 2020
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 192 (3) , 309-320
Abstract
Gamma-ray spectra were measured using a LaBr$_{3}$(Ce) spectrometer during the outage periods, aiming at quantifying the gamma source term of radiation workers’ exposure, at the CANDU nuclear power reactors, for the purposes of eye lens dosimetry. The spectra were measured inside the boiler rooms, of the Bruce Power and Ontario Power Generation (OPG) CANDU nuclear power plants, where workers are exposed to relatively high dose rates radiation fields during the maintenance work. Prior to measurements at the CANDU reactors, the pulse shaping parameters of the gamma spectrometer were optimised for high rates gamma fields, up to an input rates of 120 kcps, in order to accomplish a high output rate with a reasonable energy resolution. In parallel, the response of the LaBr$_{3}$(Ce) detector was characterized by experiments and Monte Carlo simulations. The gamma spectra measured at the CANDU reactors were reported in terms of the gamma-ray fluence rate spectrum. In all measured data, $^{60}$Co and $^{95}$Nb were main contributors of the gamma fields. The measured spectra have been used to calculate the dosimetric quantities of interest: personal dose equivalents H$_{p}$(10) and H$_{p}$(0.07) and eye lens absorbed dose.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada
This publication has 14 references indexed in Scilit:
- Characterization of a LaBr3(Ce) detector for gamma-ray spectrometry for CANDU power reactorsRadiation Measurements, 2017
- Real-Time data acquisition Prototype proposal of the ITER radial neutron camera and gamma-ray spectrometerFusion Engineering and Design, 2017
- Gamma-gamma coincidence performance of LaBr3:Ce scintillation detectors vs HPGe detectors in high count-rate scenariosApplied Radiation and Isotopes, 2017
- INFLUENCE OF DIFFERENT TYPES OF PHANTOMS ON THE CALIBRATION OF DOSEMETERS FOR EYE LENS DOSIMETRYRadiation Protection Dosimetry, 2016
- Balloon flight test of a Compton telescope based on scintillators with silicon photomultiplier readoutsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- EYE LENS DOSIMETRY FOR FLUOROSCOPICALLY GUIDED CLINICAL PROCEDURES: PRACTICAL APPROACHES TO PROTECTION AND DOSE MONITORINGRadiation Protection Dosimetry, 2015
- Study on a digital pulse processing algorithm based on template-matching for high-throughput spectroscopyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015
- Assessment of eye and body dose for interventional radiologists, cardiologists, and other interventional staffJournal of Radiological Protection, 2013
- Radiation-induced cataracts: the Health Protection Agency’s response to the ICRP statement on tissue reactions and recommendation on the dose limit for the eye lensJournal of Radiological Protection, 2012
- On the operational quantityHp(3) for eye lens dosimetryJournal of Radiological Protection, 2012