S. Mehdi Hosseini Pooya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
S. Mehdi Hosseini Pooya has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
M. Taheri
Iran Nuclear Regulatory Authority, P.O. Box 14155-1339, Tehran, Iran
5 shared publications- Mohammad Reza Kardan
Nuclear Science and Technology Research Institute, Tehran, Iran
5 shared publications H. Afarideh
Amirkabir University of Technology
4 shared publicationsT. Orouji
Iran Nuclear Regulatory Authority, Tehran, Iran
3 shared publicationsA. Enferadi
Iran Nuclear Regulatory Authority, Tehran, Iran
2 shared publicationsB. Pourshahab
Nuclear Science & Technology Research Institute, AEOI, Tehran, Iran
2 shared publications
Latest Publications
- 8 April 2022
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 42  (2) , 021519
Occupational external exposure to ionizing radiation in research-associated activities in Iran (2015-2020)
Research is an integral part of radiological and nuclear activities; thus, workers may receive different levels of occupational exposure. In the present study, occupational external exposure of workers was studied at the largest radiological and nuclear research institute of Iran from 2015–2020. The activities included research reactors, nuclear fuel cycle, development on radiopharmaceuticals and radioisotopes, particle accelerators, plasma and fusion, and nuclear agriculture. The average doses of the monitored and exposed workers were calculated to be 0.095 and 0.575 mSv, respectively, which were around their corresponding worldwide values. Moreover, the results showed that in comparison with other research activities, the workers in research reactors, nuclear fuel cycle, and development of radiopharmaceuticals and radioisotopes may face higher occupational risks. It could be, therefore, concluded that all the radiation protection measures have been effective at achieving safe research activities in Iran.
- 8 April 2022
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 42  (2) , 021519
Occupational external exposure to ionizing radiation in research-associated activities in Iran (2015-2020)
Research is an integral part of radiological and nuclear activities; thus, workers may receive different levels of occupational exposure. In the present study, occupational external exposure of workers was studied at the largest radiological and nuclear research institute of Iran from 2015–2020. The activities included research reactors, nuclear fuel cycle, development on radiopharmaceuticals and radioisotopes, particle accelerators, plasma and fusion, and nuclear agriculture. The average doses of the monitored and exposed workers were calculated to be 0.095 and 0.575 mSv, respectively, which were around their corresponding worldwide values. Moreover, the results showed that in comparison with other research activities, the workers in research reactors, nuclear fuel cycle, and development of radiopharmaceuticals and radioisotopes may face higher occupational risks. It could be, therefore, concluded that all the radiation protection measures have been effective at achieving safe research activities in Iran.
- 8 January 2022
- Published by SCI AND TECH UNIVERSAL INC in Journal of Nuclear Research and Applications
- Vol. 2  (1) , 64-70
Study on type-testing of a manual TLD-reader for dosimetry programs
In a radiation individual monitoring program, the type testing of measuring devices is a great important part of the quality management system. The IEC-62387 standard applies to dosimetry systems that measure external photon and/or beta radiation within limited ranges of the associated physical parameters. In this work, a type-testing program was conducted for a manual thermoluminescence dosimetry (TLD) reader employing the IEC-62387 radiation and environmental performance criteria. The uncertainty of non-linearity of the response of the dosimetry system in a range of 0.7-850 mSv was obtained between -15% and + 17%, which fulfilled the IEC standard range of -16% to +18%. Furthermore, the total uncertainty of all reader tests was measured to be 12%, which was less than the criteria of 20% in the IEC standard. Thus, it can be concluded that the TLD reader met all requirements of the IEC standard for the reader-tests by an appropriate margin.
- 8 January 2022
- Published by SCI AND TECH UNIVERSAL INC in Journal of Nuclear Research and Applications
- Vol. 2  (1) , 64-70
Study on type-testing of a manual TLD-reader for dosimetry programs
In a radiation individual monitoring program, the type testing of measuring devices is a great important part of the quality management system. The IEC-62387 standard applies to dosimetry systems that measure external photon and/or beta radiation within limited ranges of the associated physical parameters. In this work, a type-testing program was conducted for a manual thermoluminescence dosimetry (TLD) reader employing the IEC-62387 radiation and environmental performance criteria. The uncertainty of non-linearity of the response of the dosimetry system in a range of 0.7-850 mSv was obtained between -15% and + 17%, which fulfilled the IEC standard range of -16% to +18%. Furthermore, the total uncertainty of all reader tests was measured to be 12%, which was less than the criteria of 20% in the IEC standard. Thus, it can be concluded that the TLD reader met all requirements of the IEC standard for the reader-tests by an appropriate margin.
- 20 November 2021
- Published by Elsevier in Progress in Nuclear Energy
- Vol. 143, 104053
Effect of certain metrological parameters on the extension of urgent protective action zone in Tehran research reactor accidents
- 20 November 2021
- Published by Elsevier in Progress in Nuclear Energy
- Vol. 143, 104053
Effect of certain metrological parameters on the extension of urgent protective action zone in Tehran research reactor accidents
- 30 June 2021
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 381, 111356
Determination of urgent protective action zone in Tehran research reactors-associated accidents
- 30 June 2021
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 381, 111356
Determination of urgent protective action zone in Tehran research reactors-associated accidents
- 1 March 2021
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 193  (3-4) , 170-175
ASSESSMENT OF WHOLE BODY, SKIN AND EYE LENS DOSES OF THE INTERVENTIONAL RADIOLOGISTS AT SELECTED HOSPITALS IN IRAN
High radiation doses to the body may lead to the stochastic/deterministic effects of ionizing radiation on the critical organs as well as causing the cataract in eye lens of the clinical staff in interventional radiology. In this study, the received doses of the eyes, skin and whole body of 38 clinical staff including physicians, residents, nurses and radiotechnologists in cardiac angiography departments in three selected hospitals were assessed using personal dosemeters during two bimonthly dosimetry periods. Moreover, the correlation coefficients among the measured dose components including eye lens dose, skin dose and whole body dose equivalent in both area of under and over their lead-apron were calculated for all these occupational groups. The results show that the occupational annual dose values of the clinical staff are below the annual dose limits recommended by International Commission on Radiation Protection. Furthermore, among the measured dose components, the highest correlation coefficient value was obtained between the eye lens dose and personal dose equivalent measured over the lead apron for all the occupational groups.
- 1 March 2021
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 193  (3-4) , 170-175
ASSESSMENT OF WHOLE BODY, SKIN AND EYE LENS DOSES OF THE INTERVENTIONAL RADIOLOGISTS AT SELECTED HOSPITALS IN IRAN
High radiation doses to the body may lead to the stochastic/deterministic effects of ionizing radiation on the critical organs as well as causing the cataract in eye lens of the clinical staff in interventional radiology. In this study, the received doses of the eyes, skin and whole body of 38 clinical staff including physicians, residents, nurses and radiotechnologists in cardiac angiography departments in three selected hospitals were assessed using personal dosemeters during two bimonthly dosimetry periods. Moreover, the correlation coefficients among the measured dose components including eye lens dose, skin dose and whole body dose equivalent in both area of under and over their lead-apron were calculated for all these occupational groups. The results show that the occupational annual dose values of the clinical staff are below the annual dose limits recommended by International Commission on Radiation Protection. Furthermore, among the measured dose components, the highest correlation coefficient value was obtained between the eye lens dose and personal dose equivalent measured over the lead apron for all the occupational groups.
- 9 February 2018
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 181  (3) , 255-260
DOSIMETRIC ASPECTS OF OPTIMIZATION OF PROTECTION IN IRAN INDUSTRIAL RADIOGRAPHY PRACTICE
According to the worldwide reports, industrial radiography is one of the highest risk radiation practices due to handling high activity sources. Therefore, an optimization of protection along with appropriate investigation level and/or dose constraint is required to achieve appropriate radiological safety. This research, presents some statistical aspects of this optimization using frequency distributions and percentiles of individual recorded dose of industrial radiographers from the years 2002 to 2016 in Iran. The results show that, considering an investigation level of 4 mSv for bimonthly monitoring periods, 3-7% of population of workers has been investigated during these years. Moreover, an overall reduction on average annual and collective doses is observed, despite of the relative increasing in the number of workers. Since the frequency of periodical recorded dose at lower dose range (e.g. <4 mSv) causes greater impacts on the reduction of collective dose than the higher ranges, a retrospective average dose of non-investigated workers can also be substitute with a constant value as a dose constraint. It can be concluded that all the past measures of regulatory body and attempts of the employers have been effective improving the radiological protection in this practice in Iran. However, establishing a dose constraint seems to be essential to continue and improve this optimization of protection.
- 9 February 2018
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 181  (3) , 255-260
DOSIMETRIC ASPECTS OF OPTIMIZATION OF PROTECTION IN IRAN INDUSTRIAL RADIOGRAPHY PRACTICE
According to the worldwide reports, industrial radiography is one of the highest risk radiation practices due to handling high activity sources. Therefore, an optimization of protection along with appropriate investigation level and/or dose constraint is required to achieve appropriate radiological safety. This research, presents some statistical aspects of this optimization using frequency distributions and percentiles of individual recorded dose of industrial radiographers from the years 2002 to 2016 in Iran. The results show that, considering an investigation level of 4 mSv for bimonthly monitoring periods, 3-7% of population of workers has been investigated during these years. Moreover, an overall reduction on average annual and collective doses is observed, despite of the relative increasing in the number of workers. Since the frequency of periodical recorded dose at lower dose range (e.g. <4 mSv) causes greater impacts on the reduction of collective dose than the higher ranges, a retrospective average dose of non-investigated workers can also be substitute with a constant value as a dose constraint. It can be concluded that all the past measures of regulatory body and attempts of the employers have been effective improving the radiological protection in this practice in Iran. However, establishing a dose constraint seems to be essential to continue and improve this optimization of protection.
- 4 September 2017
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 40  (3) , 611-616
A comprehensive dose assessment of irradiated hand by iridium-192 source in industrial radiography
Among the various incidents in industrial radiography, inadvertent handling of sources by hands is one of the most frequent incidents in which some parts of the hands may be locally exposed to high doses. An accurate assessment of extremity dose assists medical doctors in selecting appropriate treatments, preventing the injury expansion in the region. In this study, a phantom was designed to simulate a fisted hand of a radiographer when the worker holds a radioactive source in their hands. The local doses were measured using implanted TLDs in the phantom at different distances from a source. Furthermore, skin dose distribution was measured by Gaf-chromic films in the palm region of the phantom. The reliability of the measurements has been studied via analytical as well as Monte-Carlo simulation methods. The results showed that the new phantom design can be used reliably in extremity dose assessments, particularly at the points next to the source.
- 4 September 2017
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 40  (3) , 611-616
A comprehensive dose assessment of irradiated hand by iridium-192 source in industrial radiography
Among the various incidents in industrial radiography, inadvertent handling of sources by hands is one of the most frequent incidents in which some parts of the hands may be locally exposed to high doses. An accurate assessment of extremity dose assists medical doctors in selecting appropriate treatments, preventing the injury expansion in the region. In this study, a phantom was designed to simulate a fisted hand of a radiographer when the worker holds a radioactive source in their hands. The local doses were measured using implanted TLDs in the phantom at different distances from a source. Furthermore, skin dose distribution was measured by Gaf-chromic films in the palm region of the phantom. The reliability of the measurements has been studied via analytical as well as Monte-Carlo simulation methods. The results showed that the new phantom design can be used reliably in extremity dose assessments, particularly at the points next to the source.
- Open Access
- 1 March 2017
- Vol. 7  (1) , 51-58
Comparative Analysis of Neural Network Training Methods in Real-time Radiotherapy
The motions of body and tumor in some regions such as chest during radiotherapy treatments are one of the major concerns protecting normal tissues against high doses. By using real-time radiotherapy technique, it is possible to increase the accuracy of delivered dose to the tumor region by means of tracing markers on the body of patients. This study evaluates the accuracy of some artificial intelligence methods including neural network and those of combination with genetic algorithm as well as particle swarm optimization (PSO) estimating tumor positions in real-time radiotherapy. One hundred recorded signals of three external markers were used as input data. The signals from 3 markers thorough 10 breathing cycles of a patient treated via a cyber-knife for a lung tumor were used as data input. Then, neural network method and its combination with genetic or PSO algorithms were applied determining the tumor locations using MATLAB© software program. The accuracies were obtained 0.8%, 12% and 14% in neural network, genetic and particle swarm optimization algorithms, respectively. The internal target volume (ITV) should be determined based on the applied neural network algorithm on training steps.
- 1 March 2017
- Vol. 7  (1) , 51-58
Open AccessComparative Analysis of Neural Network Training Methods in Real-time Radiotherapy
The motions of body and tumor in some regions such as chest during radiotherapy treatments are one of the major concerns protecting normal tissues against high doses. By using real-time radiotherapy technique, it is possible to increase the accuracy of delivered dose to the tumor region by means of tracing markers on the body of patients. This study evaluates the accuracy of some artificial intelligence methods including neural network and those of combination with genetic algorithm as well as particle swarm optimization (PSO) estimating tumor positions in real-time radiotherapy. One hundred recorded signals of three external markers were used as input data. The signals from 3 markers thorough 10 breathing cycles of a patient treated via a cyber-knife for a lung tumor were used as data input. Then, neural network method and its combination with genetic or PSO algorithms were applied determining the tumor locations using MATLAB© software program. The accuracies were obtained 0.8%, 12% and 14% in neural network, genetic and particle swarm optimization algorithms, respectively. The internal target volume (ITV) should be determined based on the applied neural network algorithm on training steps.
- 15 April 2016
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 174  (1) , 68-73
Type Testing of Model 7200 Automatic TLD Reader
The type testing of measuring devices is one of the most important parts of a quality management system in a personal dosimetry services program. In this study, based upon the International Electrotechnical Commission (IEC) 62387 criteria, a reader-testing program was performed for a home-made personal thermoluminescent dosimetry (TLD) reader. The stability of the reader, the effects of light exposure, temperature and fluctuations of primary power supply on TLD read-outs as the main parameters were investigated in this program. Moreover, this study assesses some important criteria of dosimetry system including the non-linearity of response, reusability, after effect and overload that may include significant contribution in the performance of a reader. The results showed that the TLD reader met all requirements of the IEC for the reader tests by a large margin.
- 15 April 2016
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 174  (1) , 68-73
Type Testing of Model 7200 Automatic TLD Reader
The type testing of measuring devices is one of the most important parts of a quality management system in a personal dosimetry services program. In this study, based upon the International Electrotechnical Commission (IEC) 62387 criteria, a reader-testing program was performed for a home-made personal thermoluminescent dosimetry (TLD) reader. The stability of the reader, the effects of light exposure, temperature and fluctuations of primary power supply on TLD read-outs as the main parameters were investigated in this program. Moreover, this study assesses some important criteria of dosimetry system including the non-linearity of response, reusability, after effect and overload that may include significant contribution in the performance of a reader. The results showed that the TLD reader met all requirements of the IEC for the reader tests by a large margin.
- 24 February 2016
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 36  (1) , 184-194
A root cause analysis of the high occupational doses of industrial radiographers in Iran
The Iran Nuclear Regulatory Authority has investigated overexposure cases in industrial radiography over a period of three years. Radiographers with thermoluminescence dosimeter (TLD) records of more than 4 mSv in any 2 month routine monitoring period were asked to fill in a questionnaire explaining their points of view of the reasons for such relatively high doses. The responses showed that more than 50% of the radiographers did not agree with their recorded TLD doses, although the majority of the alternative explanations were weak. The main causes of overexposures were found to be difficult working conditions and ignoring safety principles while accidents or device failures were a minor contribution. Also, there was poor correlation between the TLDs and direct reading dosimeters worn by the radiographers, indicating that personal monitoring instructions were not being implemented appropriately.
- 24 February 2016
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 36  (1) , 184-194
A root cause analysis of the high occupational doses of industrial radiographers in Iran
The Iran Nuclear Regulatory Authority has investigated overexposure cases in industrial radiography over a period of three years. Radiographers with thermoluminescence dosimeter (TLD) records of more than 4 mSv in any 2 month routine monitoring period were asked to fill in a questionnaire explaining their points of view of the reasons for such relatively high doses. The responses showed that more than 50% of the radiographers did not agree with their recorded TLD doses, although the majority of the alternative explanations were weak. The main causes of overexposures were found to be difficult working conditions and ignoring safety principles while accidents or device failures were a minor contribution. Also, there was poor correlation between the TLDs and direct reading dosimeters worn by the radiographers, indicating that personal monitoring instructions were not being implemented appropriately.