Eduardo Alberto Fancello
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Eduardo Alberto Fancello has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
Thiago André Carniel
Polytechnic School, Community University of Chapecó Region, Chapecó, Brazil
10 shared publications- Thiago André Carniel
Graduate Program in Health Sciences, Community University of Chapecó Region, Chapecó, SC, Brazil
9 shared publications - Bruno Klahr
GRANTE - Department of Mechanical Engineering, Federal University of Santa Catarina, Florianópolis, SC, Brazil
8 shared publications - José Luís Medeiros Thiesen
GRANTE ‐ Mechanical and Analysis Design Group, Department of Mechanical Engineering Federal University of Santa Catarina (UFSC) Florianópolis SC Brazil
8 shared publications Bruno Klahr
Department of Mechanical Engineering, Federal University of Santa Catarina, Florianopolis, Brazil
6 shared publicationsCarlos Rodrigo de Mello Roesler
Biomechanical Engineering Laboratory—LEBm, Department of Mechanical Engineering Federal University of Santa Catarina Florianópolis Brazil
6 shared publications
Latest Publications
- Open Access
- 20 October 2026
- Published by Elsevier in Computer Methods in Applied Mechanics and Engineering
- Vol. 464
A micromechanical perspective on ascending aortic dissection: A multiscale computational framework
- 20 October 2026
- Published by Elsevier in Computer Methods in Applied Mechanics and Engineering
- Vol. 464
Open AccessA micromechanical perspective on ascending aortic dissection: A multiscale computational framework
- Open Access
- 7 March 2026
- Published by Elsevier in International Journal of Solids and Structures
- Vol. 332
Towards hierarchical micropolar composites: A computational homogenization model of heterogeneous Cosserat media
- 7 March 2026
- Published by Elsevier in International Journal of Solids and Structures
- Vol. 332
Open AccessTowards hierarchical micropolar composites: A computational homogenization model of heterogeneous Cosserat media
- Open Access
- 16 December 2025
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (1) , e70102
Load Transfer in Tibial Intramedullary Nailing: Effects of Fracture Level, Screw Configuration and Nail‐Canal Clearance
Intramedullary nails are widely recognized for their high stabilization capacity and are considered the gold standard for tibial fracture treatment. However, hardware failure, especially of distal screws, is frequently reported, especially in cases involving distal fractures. Although various experimental studies explore screw configurations, few quantify the mechanical loads acting on individual screws at different fracture locations. This study numerically evaluates two fixation systems: one with four screws and another with five, including an additional distal screw (DS3). The results show that the fifth screw significantly reduces von Mises stress, especially in distal fractures, though the improvements in overall stability are less pronounced. The mechanical implications on the inclusion of a clearance between the nail and endosteal surface are assessed. The stresses in the locking screws are significantly higher when the reaming clearance is included in the simulation. Despite mechanical advantages, clinical trade‐offs such as increased surgical complexity and radiation exposure must be considered.
- 16 December 2025
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (1) , e70102
Open AccessLoad Transfer in Tibial Intramedullary Nailing: Effects of Fracture Level, Screw Configuration and Nail‐Canal Clearance
Intramedullary nails are widely recognized for their high stabilization capacity and are considered the gold standard for tibial fracture treatment. However, hardware failure, especially of distal screws, is frequently reported, especially in cases involving distal fractures. Although various experimental studies explore screw configurations, few quantify the mechanical loads acting on individual screws at different fracture locations. This study numerically evaluates two fixation systems: one with four screws and another with five, including an additional distal screw (DS3). The results show that the fifth screw significantly reduces von Mises stress, especially in distal fractures, though the improvements in overall stability are less pronounced. The mechanical implications on the inclusion of a clearance between the nail and endosteal surface are assessed. The stresses in the locking screws are significantly higher when the reaming clearance is included in the simulation. Despite mechanical advantages, clinical trade‐offs such as increased surgical complexity and radiation exposure must be considered.
- Open Access
- 11 August 2025
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 41 (8) , e70084
The Effects of Vertebral Body Tethering on the Intervertebral Discs and Facet Joints: A Numerical Analysis
Anterior vertebral body tethering (VBT) is a promising technique for the treatment of adolescent idiopathic scoliosis. However, the segments directly treated with VBT can experience substantial loads resulting from the tether pretension, which may alter internal stresses and potentially compromise structures such as the intervertebral discs (IVDs) and facet joints. We aim to investigate the effects of tether within the VBT on the L1–L2 IVD stresses and contact forces of the facet joints, using an extensively calibrated and validated finite element model of the T10–S1 spine. The implant was inserted on the left side of the T10–L3 and tensioned up to 300 N representing the tether pretension applied during surgery and the case of the postoperative neutral position. Subsequently, the spine was tested under an external pure moment of 8 Nm. The tether pretension resulted in a significant increase in the IVD stresses. In the neutral position, a gradual increase in intervertebral pressure (IDP) at the center of the IVD of 0.094, 0.181, and 0.267 MPa was observed after applying forces of 100, 200, and 300 N to the tether, respectively. The contact force of the left facet joint also increased with pretension. It was 12.5 N for the native spine and gradually increased to 49.5, 82.0, and 100.9 N for tether pretensions of 100, 200, and 300 N, respectively, during extension. These results indicate that tether pretension is a key parameter that increases the internal stresses of the IVD and the contact forces of the facet joints at the implant side.
- 11 August 2025
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 41 (8) , e70084
Open AccessThe Effects of Vertebral Body Tethering on the Intervertebral Discs and Facet Joints: A Numerical Analysis
Anterior vertebral body tethering (VBT) is a promising technique for the treatment of adolescent idiopathic scoliosis. However, the segments directly treated with VBT can experience substantial loads resulting from the tether pretension, which may alter internal stresses and potentially compromise structures such as the intervertebral discs (IVDs) and facet joints. We aim to investigate the effects of tether within the VBT on the L1–L2 IVD stresses and contact forces of the facet joints, using an extensively calibrated and validated finite element model of the T10–S1 spine. The implant was inserted on the left side of the T10–L3 and tensioned up to 300 N representing the tether pretension applied during surgery and the case of the postoperative neutral position. Subsequently, the spine was tested under an external pure moment of 8 Nm. The tether pretension resulted in a significant increase in the IVD stresses. In the neutral position, a gradual increase in intervertebral pressure (IDP) at the center of the IVD of 0.094, 0.181, and 0.267 MPa was observed after applying forces of 100, 200, and 300 N to the tether, respectively. The contact force of the left facet joint also increased with pretension. It was 12.5 N for the native spine and gradually increased to 49.5, 82.0, and 100.9 N for tether pretensions of 100, 200, and 300 N, respectively, during extension. These results indicate that tether pretension is a key parameter that increases the internal stresses of the IVD and the contact forces of the facet joints at the implant side.
- 25 April 2025
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 47 (6) , 1-15
The lower shear modulus of younger subjects can result in stronger Achilles tendons: an in silico analysis
- 25 April 2025
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 47 (6) , 1-15
The lower shear modulus of younger subjects can result in stronger Achilles tendons: an in silico analysis
- 20 February 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (10) , 3562-3570
Deep medial collateral ligament plays a stabilising role under degenerative medial meniscus root tears
Purpose: Several posterior medial meniscal root (PMMR) repair techniques have been developed to restore the load‐bearing function of the meniscus and reduce extrusion. The medial meniscotibial ligament (MMTL) has been shown to play a significant role in meniscal stability. This study evaluates the stabilising function of the MMTL by directly influencing the force exerted on the PMMR during weight‐bearing and valgus motion of the knee. Our aim is to investigate whether loss of MMTL integrity is a determining factor in PMMR subluxation.Methods: Using a 3D model of the knee with parameters from experimental studies, compressive and valgus loading scenarios were simulated using the finite element method to analyse the mechanical response of different knee structures. To investigate the correlation between the integrity of the MMTL and the force acting on the PMMR, different degrees and types of injuries to both structures were modelled for comparison with the healthy joint, providing insights into their importance in preventing or correcting extrusion.Results: During compressive loading, tears in the MMTL and PMMR result in a 5.8% and 30.9% increase in meniscal extrusion, respectively, while a combined injury results in a 43.9% increase, indicating that the MMTL provides a secondary constraint against extrusion. Moreover, the importance of the MMTL in restraining extrusion becomes more pronounced as the PMMR weakens, as is typical in degenerative tears. Finally, during valgus motion, the MMTL prevents separation of the meniscus from the tibial plateau and reduces strain/stress on the PMMR.Conclusion: The integrity of the MMTL plays a crucial role in reducing meniscal extrusion and PMMR overload, particularly when the root is affected by degenerative tears. Therefore, surgical repair of the MMTL can improve meniscal function, potentially reducing the risk of osteoarthritis and should be considered as a better treatment strategy for PMMR tears.Level of Evidence: Level III.
- 20 February 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (10) , 3562-3570
Deep medial collateral ligament plays a stabilising role under degenerative medial meniscus root tears
Purpose: Several posterior medial meniscal root (PMMR) repair techniques have been developed to restore the load‐bearing function of the meniscus and reduce extrusion. The medial meniscotibial ligament (MMTL) has been shown to play a significant role in meniscal stability. This study evaluates the stabilising function of the MMTL by directly influencing the force exerted on the PMMR during weight‐bearing and valgus motion of the knee. Our aim is to investigate whether loss of MMTL integrity is a determining factor in PMMR subluxation.Methods: Using a 3D model of the knee with parameters from experimental studies, compressive and valgus loading scenarios were simulated using the finite element method to analyse the mechanical response of different knee structures. To investigate the correlation between the integrity of the MMTL and the force acting on the PMMR, different degrees and types of injuries to both structures were modelled for comparison with the healthy joint, providing insights into their importance in preventing or correcting extrusion.Results: During compressive loading, tears in the MMTL and PMMR result in a 5.8% and 30.9% increase in meniscal extrusion, respectively, while a combined injury results in a 43.9% increase, indicating that the MMTL provides a secondary constraint against extrusion. Moreover, the importance of the MMTL in restraining extrusion becomes more pronounced as the PMMR weakens, as is typical in degenerative tears. Finally, during valgus motion, the MMTL prevents separation of the meniscus from the tibial plateau and reduces strain/stress on the PMMR.Conclusion: The integrity of the MMTL plays a crucial role in reducing meniscal extrusion and PMMR overload, particularly when the root is affected by degenerative tears. Therefore, surgical repair of the MMTL can improve meniscal function, potentially reducing the risk of osteoarthritis and should be considered as a better treatment strategy for PMMR tears.Level of Evidence: Level III.
- 31 October 2024
- Published by Elsevier in Computer Methods in Applied Mechanics and Engineering
- Vol. 433
Second-order computational homogenization for bridging poromechanical scales under large deformations
- 31 October 2024
- Published by Elsevier in Computer Methods in Applied Mechanics and Engineering
- Vol. 433
Second-order computational homogenization for bridging poromechanical scales under large deformations
- 10 July 2024
- Published by Springer Nature in Journal of Elasticity
- Vol. 156 (3) , 917-954
A Second-Order Multiscale Model for Finite-Strain Poromechanics Based on the Method of Multiscale Virtual Power
- 10 July 2024
- Published by Springer Nature in Journal of Elasticity
- Vol. 156 (3) , 917-954
A Second-Order Multiscale Model for Finite-Strain Poromechanics Based on the Method of Multiscale Virtual Power
- 19 March 2024
- Published by IOP Publishing in Inverse Problems
- Vol. 40 (5) , 055002
A single level set function approach for multiple material-phases applied to full-waveform inversion in the time domain
This paper presents a multiple material-phase level-set approach for acoustic full-waveform inversion in the time domain. By using a single level set (LS) function, several level values are used to define virtual boundaries between material phases with different (and known) wave propagation velocities. The aim of the proposed approach is to provide a suitable framework to identify multiple/nested inclusions or a finite number of almost homogeneous sedimentary layers with sharp interfaces between them. The use of a single LS function provides a significant reduction in the number of variables to be identified, when compared with the usual multi-material phase approaches defined by multiple functions, especially for problems with a high number of degrees of freedom. Numerical experiments show satisfactory results in identifying simultaneously different interfaces. Cases with and without inverse crime are evaluated, showing that the approach is reasonably robust in dealing with such a condition.
- 19 March 2024
- Published by IOP Publishing in Inverse Problems
- Vol. 40 (5) , 055002
A single level set function approach for multiple material-phases applied to full-waveform inversion in the time domain
This paper presents a multiple material-phase level-set approach for acoustic full-waveform inversion in the time domain. By using a single level set (LS) function, several level values are used to define virtual boundaries between material phases with different (and known) wave propagation velocities. The aim of the proposed approach is to provide a suitable framework to identify multiple/nested inclusions or a finite number of almost homogeneous sedimentary layers with sharp interfaces between them. The use of a single LS function provides a significant reduction in the number of variables to be identified, when compared with the usual multi-material phase approaches defined by multiple functions, especially for problems with a high number of degrees of freedom. Numerical experiments show satisfactory results in identifying simultaneously different interfaces. Cases with and without inverse crime are evaluated, showing that the approach is reasonably robust in dealing with such a condition.