VRV. Karthik Raj

V. Karthik Raj

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


V. Karthik Raj has a total of 39 co-authors. Here are the top co-authors by number of shared publications:

  • Oinam Robita Chanu

    Department of Biomedical Engineering, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India

    2 shared publications
  • Oinam Robita Chanu

    Department of Biomedical Engineering, SRM Institute of Science and Technology, Kattankulathur-603203, Tamil Nadu, India

    2 shared publications
  • S. Tarunkumar

    Department of Biomedical Engineering, SRM Institute of Science and Technology, (Deemed to be University under section 3 of UGC Act 1956), Kattankulathur, Kancheepuram District, Tamilnadu 603203, India

    2 shared publications
  • S. Uthvag

    Department of Biomedical Engineering, SRM Institute of Science and Technology, Kattankulathur 603203, Tamilnadu, India

    2 shared publications
  • A Gautham

    Department of Biomedical Engineering, SRM University, Chennai, India

    1 shared publication
  • A. Gautham

    Department of Biomedical Engineering, SRM University, Kattankulathur, Kancheepuram District, Tamilnadu 603203, India

    1 shared publication

Latest Publications

  • Open Access

    Deep Learning for Automatic Diagnosis of Skin Cancer Using Dermoscopic Images

    by S. Rama Krishna, Karthik Raj V, Anand Gudur, Siddharth Jain, Shanmugavel Deivasigamani, Mohit Tiwari, K. G. S. Venkatesan

    Over the past few years, the healthcare industry has seen a dramatic increase in the use of intelligent automation enabled by AI technology. These developments are made to better the standard of medical decision making and the standard of treatment given to patients. Fuzzy boundaries, shifting sizes, and aberrations like hair or ruler lines all provide difficulties for automatic detection of skin lesions in dermoscopic images, slowing down the otherwise efficient process of diagnosing skin cancer. However, these difficulties may be conquered by employing image processing software. To address these issues, the authors of this paper provide a novel IMLT-DL model for intelligent dermoscopic image processing. Multi-level thresholding and deep learning are brought together in this model. Top hat filtering and inpainting have been included into IMLT-DL for use in image processing. In addition, Mayfly Optimization has been used in tandem with multilayer Kapur's thresholding to identify specific trouble spots. For further investigation, it uses an Inception v3-based feature extractor, and for data classification, it makes use of gradient boosting trees (GBTs). On the ISIC dataset, this model was shown to outperform state-of-the-art alternatives by a margin of 0.992% over the duration of trial iterations. These advances are a major step forwards in the quest for faster and more accurate skin lesion detection.


  • Open Access

    Design of a Wireless Single Arm Electrocardiograph System

    by Karthik Raj. V, Tushar Sankaran J, Soumya Samantaray, Sayan Chakraborty, Srishti Saxena

    Electrocardiograms (ECGs) are a method of assessment of cardiac electrical activity. It is the heart’s electrophysiological activity which occurs by the conduction of electrical impulses from the Sinoatrial (SA) node and the Atrioventricular (AV) node across the cardiac muscles and is displayed as a voltage-time graph. Conventionally, they have been acquired using a system of ten surface electrodes placed in different locations throughout the body in a 12-lead system. Single Arm ECG systems, where the ECG rhythm is obtained from only a single part of the body, replace the need for ten different electrodes to detect the heart's activity. Three pre-gelled electrodes are applied in different locations of the left arm to derive the sinus rhythm signal of a subject. An op-amp based hardware instrument has been developed for this purpose with active filters and amplifiers to perform signal conditioning. This paper demonstrates the implementation of a single arm hardware system of small size to improve portability, used as an ECG detection method and the results from various subjects taken at different gain values to improve the view of the signal, while also presenting a method to transmit the data of the signals wirelessly through an Internet-of-things (IoT) platform.


  • Development of a Hardware Circuit for Real-Time Acquisition of Brain Activity Using NI myDAQ

    by Oinam Robita Chanu, R. Kalpana, B. Soorya, R. Santhosh, V. Karthik Raj

    Electroencephalography (EEG) is the recording of electrical activity of the brain. The 10–20 system is the standard electrode location method used to acquire EEG data, which uses 21 electrodes to record the electrical activity of the brain. Patient preparation and correct electrode placement are important to obtain reliable outputs. The current 10–20 system consumes greater time for patient preparation and also causes discomfort due to a higher number of electrodes being used or wearing an uncomfortable cap. This paper focuses on reducing the number of electrodes, thus reducing patient discomfort as well as preparation time. Advancement in the field of hardware and software processing has led to the utilization of brain waves for communication between human and the computer. This work deals with EEG-based Brain–Machine Interface (BMI) intended for designing a portable single-channel EEG signal acquisition system. EEG signal was acquired using the data acquisition module [National Instruments (NI) myDAQ] and the signal was viewed in the NI Laboratory Virtual Instrument Engineering Workbench (LabVIEW) environment. It was observed that the peak-to-peak amplitude of alpha, beta and theta waves changes in accordance with the activity the subjects performed. Thus, the developed instrument was tested on 10 different subjects to acquire the alpha, beta and theta waves by performing different activities. From the results, it can be concluded that the developed system can be used for studying a person’s brain waves (alpha, beta and theta) based on the activity performed by the subject with a limited number of electrodes.


  • REAL-TIME EMG ACQUISITION AND FEATURE EXTRACTION FOR REHABILITATION AND PROSTHESIS

    by S. Uthvag, P. Vijay Sai, S. Dheeraj Kumar, Hariharan Muthusamy, Oinam Robita Chanu, V. Karthik Raj

    Electromyogram signals have been used for various applications in the healthcare sector for developing various methodologies and techniques in rehabilitation and prosthetics. This paper focuses on the use of EMG signals of trans-radial amputees for developing a myoelectric lower limb prosthesis capable of individual finger movement. The aim of this work is to develop proper hardware and software systems for real-time EMG classification. An improved double thresholding method for onset and offset detections has been developed to ensure its applicability in real-time. The proposed algorithm has been tested with real-time patient EMG signals using a three-lead electrode system from flexor digitalis region of the hand. Around 3000 samples of usable data corresponding to the flexion of each finger (Thumb-553, Index-655, Middle-723, Ring-720, Little-655) were acquired from 10 healthy subjects. The resultant extracted features were classified using various classifiers (KNN, KNN with PCA and LDA) and a comparison was done between the accuracies acquired from a commonly shared dataset against a subject-specific dataset. A robust onset signal processing algorithm enabled the real-time classification of EMG in noisy environments.


  • LOW-COST AUTOMATED NURSE CALL SYSTEM FOR IMPROVING PATIENT CARE USING LabVIEW

    by K. S. Arjun Subramaniyan, S. Tarunkumar, Y. Vinish, K. Sanchana, Oinam Robita Chanu, S. Gnanavel, P. Muthu, D. Ashokkumar, V. Karthik Raj

    Nurse Call systems are used to signal nurses for medical assistance. Present day technology uses push buttons and room lamps integrated with liquid crystal displays (LCDs) at the nurse station in most hospitals in India. Such systems are not automated and also have the risk of false alarms due to mishandling by caretakers. This prototype uses an automated technology, when implemented monitors patients in critical care units continuously and detects specific arrhythmia conditions with the help of thresholds based on pre-set standards and the information is passed on to the nurse station only in case of an emergency thus allowing continuous monitoring of the patient. Since the system is centralized, the CODE BLUE team (Dedicated team in every hospital to attend patients during a cardiac emergency) is also alerted at the same time minimizing the delay in medical assistance. This system would be most useful in emergency conditions such as Cardiac arrest, thus increasing the chances of survival of a patient. For this project, LabVIEW (Laboratory Virtual Instrument Engineering Workbench) 2014 version (software) and National Instruments MyRIO (NI Reconfigurable Input/Output) hardware are used. On comparison with some of the present day nurse call systems, the proposed system is also economical in most of the developing countries such as in India.


  • ACQUISITION AND CHARACTERIZATION OF BOWEL SOUNDS USING LabVIEW SOFTWARE

    by Oinam Robita Chanu, V. Karthik Raj

    Bowel sounds (BSs) are defined as the sounds when contractions of the lower intestines propel forward. It is simple, but empirical and too subjective. Auscultation is the traditional technique for determining gastrointestinal functioning. The most physicians and nurses carry out a cursory listen for BS resulting in misinterpretation. The aim and objective of this project are to design a low-cost prototype of an electronic stethoscope to acquire the BSs and analyzing its characteristics using LabVIEW software. The developed prototype is interfaced with the software, and the BSs are recorded from the epigastric region and the umbilical region. The characteristics of recorded BSs are analyzed in the LabVIEW software with the available tool like signal analysis and sound analysis. For this study, a total number of 17 subjects are included. Around 1min BS recordings are performed on 12 healthy subjects and 5 abnormal subjects. The result showed that the BSs are recorded from the designed prototype. The frequen...


  • DRY ELECTRODE MATERIAL TESTING AND GAIN ANALYSIS FOR SINGLE ARM ECG SYSTEM

    by V. Karthik Raj, J. Abdul Kader Naseem, S. Devapriya, A. Gautham, S. Uthvag, Parveen Sultana, S. Anand, M. Hari Krishna, Sara Ghosh, K. Srivishnuprasath

    Electrocardiography (ECG) is a medical diagnostic procedure used to record the electrical activity of the heart and display it as a waveform. For picking the ECG waveform, wet and dry electrodes can be utilized. Lots of dry electrode related studies have been carried out in different parts of the world. This paper focuses on the acquisition of ECG from the left arm and right arm separately and comparing the waveforms and gain required for the system. In addition to that, different dry electrode materials and dimensions are used to check the acquisition of ECG waveform from the single arm. Dry electrodes employed in this study include copper, brass, phosphor bronze and nickel silver. The various dimensions used in this study are 3cm×3cm×0.5mm, 2.5cm×2.7cm×0.5mm, 2.5cm×2.5cm×0.5mm, 2cm×3cm×0.5mm, 2cm×2cm×0.5mm and 1cm×3cm×0.5mm. A total of five healthy subjects are used in this study for the acquisition of ECG. The results are very much promising in that the gain required for the left arm ECG system is less...


  • AN ASSISTIVE DEVICE FOR QUADRIPLEGIC PATIENTS USING NI-MyRIO

    by S. Tarunkumar, S. S. P. Raghul, V. Karthik Raj, Vetrivel Pon

    One of the primary neural disorders is Paralysis, which causes loss of motion in one or more parts of the body muscles. Quadriplegia is a condition, where both the arms and the legs are paralyzed; as a result, the person is entirely dependent on the caretakers. To help them overcome their difficulties, we proposed a system which can control the house appliances, to communicate, monitor and alert the caregivers or the doctors in the case of an emergency by using his/her eye movements. These eye movements can be recorded using Electrooculography (EOG) that can be used to perform these simple tasks. EOG is the measurement of the corneo-retinal standing potential of the eye. This paper describes how the acquisition of EOG signals is made which can be used to control the home appliances. Also, a communication method for the quadriplegic patients to interact with the caregivers and the designing of a monitoring system which can be used for monitoring the quadriplegic patients and an alarm with pop-up message that can be used to alert the caretakers. The proposed work also describes the electrode placements so as to reduce the artifacts, the types of electrodes used, simple circuits and the programming that are used to control the house appliances using EOG signals. The picked up EOG signal from the subject is given to the processing block which suitably provides an output which can be utilized as an input to the NI MyRIO where the programming is done to control the household appliances and for communication.


  • DESIGNING OF A SINGLE ARM SINGLE LEAD ECG SYSTEM FOR WET AND DRY ELECTRODE: A COMPARISON WITH TRADITIONAL SYSTEM

    by A Gautham, V Karthik Raj

    Electrocardiography is a non-invasive medical diagnostic procedure used to record the electrical activity of the heart as a waveform. An electrocardiogram (ECG) can be utilized to evaluate the electrical activity of the heart, also the rate and regularity of the heart beat and other related diagnoses. ECG systems have evolved along since its invention and researches are going on continuously to decrease the complexity of ECG systems. This paper discusses the designing of a single arm single lead ECG system to acquire ECG signals from areas of left arm alone. The proposed system uses pre-gelled disposable surface electrodes and dry copper electrodes. The single arm approach in ECG acquisition reduces the complexity of the system to a greater extent and also improves the ease of use and patient comfort. The paper discusses the various designing aspects and the working of the single arm single lead ECG system. A hardware only approach has been used here in the design of the ECG system. ECGs were obtained from 10 healthy subjects using the proposed system, which were compared along with ECG acquired from a commercially used system. The obtained ECG had morphological features similar to a normal ECG waveform. The results of the comparison were very promising and all the values recorded were in the normal range of values for the respective parameters in comparison.


  • Analysis of structural mechanics of solid microneedle using COMSOL software

    by Urvi Kanakaraj, Tshewang Lhaden, Karthik Raj V.

    Microneedles are currently being extensively researched for therapeutic and diagnostic applications, as they are painless, cheaper than conventional needles, and reduce risk of infection. In this paper, we have selected 10 materials for solid microneedle and have performed the structural analysis of each material using COMSOL Multiphysics 4.3. The study was based on the factors affecting microneedle strength such as buckling and bending forces. The result indicated that the microneedle made of Silicon carbide was superior to the other selected materials and while considering the property of biodegradability for the same study, Silk was preferred. PLA and Polycarbonate experienced buckling and thus were not preferred from the selected materials.