MTMark L. Trew

Mark L. Trew

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mark L. Trew has a total of 65 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Continuously‐Resolved 3D Organisation of the Rat Stomach

    by Savindi Wijenayaka, Mark L. Trew, Alys R. Clark, Recep Avci, Leo K. Cheng, Peng Du

    The anatomy of the stomach informs about the specific inter‐regional functions of the digestive process. Eight whole stomachs from Sprague–Dawley rats were stained with phosphotungstic acid (PTA) and imaged using a SkyScan 1172 CT scanner. Following segmentation of the mucosal‐submucosal and muscle‐serosal layers, thickness, fractional anisotropy, and muscle fibre orientation were calculated and reconstructed over three‐dimensional anatomies. In the mucosal‐submucosal layers, thickness increased from the forestomach through the glandular corpus to the antrum, with characteristic transitions at both sphincters and into the duodenum. In the muscle‐serosal layers, thickness was greatest at the lower oesophageal sphincter and consistently greater along the lesser curvature than the greater curvature. Smooth muscles exhibited a bimodal orientation distribution, with circumferential fibres more prominent in the corpus and antrum and longitudinal fibres more prominent in the forestomach. Fractional anisotropy further reflected regional functional differentiation, with denser fibre convergence and lower directional coherence near the lower oesophageal junction. The findings revealed continuous structural transitions between gastric regions, regional gradients in fibre density and organisation, and provide an anatomical basis for the motility of the rat stomach during digestion.

  • Open Access

    Structural determinants of re‐entrant drivers in atrial fibrillation: insights from digital twins derived from 3D micrometre‐resolution imaging of human heart

    by Anuradha Kulathilaka, Roshan Sharma, James Kennelly, Ning Li, Jieyun Bai, Bruce H. Smaill, Mark L. Trew, Vadim V. Fedorov, Jichao Zhao

    Atrial fibrillation (AF) affects over 45 million people worldwide. Although catheter ablation is the most promising treatment, its outcomes in patients with persistent AF remain suboptimal. This is attributed to insufficient insights into how structural substrates in human atria sustain AF and the lack of precise methods to identify ablation targets. Here, we investigate how atrial wall thickness (AWT), myofibre organisation and fibrosis govern the stability and localisation of re‐entrant drivers (RDs). Five human donor atria from individuals with cardiac co‐morbidities were functionally characterised using optical mapping and structurally imaged at an isotropic resolution of 170–180 µm via 9.4T gadolinium‐enhanced magnetic resonance imaging. Heart‐specific digital twins with and without specific structural components were developed to evaluate their effects on RD stability and localisation. Simulations revealed that AWT variations had a global influence on RD dynamics, with RDs preferentially drifting toward and stabilising in atrial regions with smaller AWT values, more prominently in the right atrium (RA) than the left atrium (LA). Incorporating myofibre orientation further constrained RD localisation, particularly in the posterior LA and lateral RA, where well‐aligned myofibres bordered regions of disorganised fibres. This effect was more pronounced in the RA than in the LA. In contrast, fibrosis had the most significant influence on RD localisation in the LA, with RDs anchoring at fibrotic border zones. This study highlights AWT as a key determinant of AF maintenance, with 3D myofibre orientation and fibrosis holding region‐specific influences on RD localisation and stability. RDs were consistently localised in regions with smaller AWT, aligned myofibres adjacent to disorganised structures and/or fibrotic border zones. These findings provide mechanistic insights into human AF maintenance and potential structural substrate targets for mechanism‐based improved ablation strategies. image Key points: Digital twins of human atria ex vivo revealed that atrial wall thickness (AWT) has a global impact on re‐entrant driver (RD) dynamics. RDs drifted toward and along AWT gradients, and tended to localise in regions with smaller AWT. This effect was more pronounced in the right atrium (RA) than in the left atrium (LA). Incorporating myofibre orientation into heart‐specific AWT models further constrained RD localisation, particularly in the posterior LA and the lateral RA, where well‐aligned myofibres bordered disorganised regions. This effect was most substantial in the RA due to the prominent myofibre bundle architecture in the lateral RA. Fibrosis had a lesser impact on RDs in the RA compared to the LA. Specifically, RD locations remain relatively stable in the RA, regardless of the presence or absence of fibrosis. In contrast, fibrosis in the LA significantly altered RD distribution, with RDs clustering near fibrotic border zones.


  • Open Access

    Multimodal imaging shows fibrosis architecture and action potential dispersion are predictors of arrhythmic risk in spontaneous hypertensive rats

    by Prashanna Khwaounjoo, Gregory B. Sands, Ian J. LeGrice, Girish Ramulgun, Jesse L. Ashton, Johanna M. Montgomery, Anne M. Gillis, Bruce H. Smaill, Mark L. Trew

    Hypertensive heart disease (HHD) increases risk of ventricular tachycardia(VT) and ventricular fibrillation (VF). The roles of structural vs. electrophysiological remodelling and age vs. disease progression arc not fully understood. This cross-sectional study of cardiac alterations through HHD investigates mechanistic contributions to VT/VF risk. Risk was electrically assessed in Langendorff-perfused, spontaneously hypertensive rat hearts at 6, 12 and 18 months, and paced optical membrane voltage maps were acquired from the left ventricular (LV) free wall epicardium. Distributions of IN patchy fibrosis and 3D cellular architecture in representative anterior LV mid-wall regions were quantified from macroscopic and microscopic fluorescence images of optically cleared tissue. Imaging showed increased fibrosis from 6 months, particularly in the inner LV free wall. Myocyte cross-section increased at 12 months, while inter-myocyte connections reduced markedly with fibrosis. Conduction velocity decreased from 12 months, especially transverse to the myofibre direction, with rate-dependent anisotropy at 12 and 18 months, but not earlier. Action potential duration (APD) increased when clustered by age, as did API) dispersion at 12 and 18 months. Among 10 structural, functional and age variables, the most reliably linked were VT/VF risk, general LV fibrosis, a measure quantifying patchy fibrosis, and non-age clustered API) dispersion. VT/VF risk related to a quantified measure of patchy fibrosis, but age did not factor strongly. The findings are consistent with the notion that VT/VF risk is associated with rate-dependent repolarization heterogeneity caused by structural remodelling and reduced lateral electrical coupling between LV myocytes, providing a substrate for heterogeneous intramural activation as HHD progresses.


  • It's clearly the heart! Optical transparency, cardiac tissue imaging, and computer modelling

    by Gregory B. Sands, Jesse L. Ashton, Mark L. Trew, David Baddeley, Richard D. Walton, David Benoist, Igor R. Efimov, Nicolas P. Smith, Olivier Bernus, Bruce H. Smaill


  • Open Access

    Cardiac Conduction Velocity, Remodeling and Arrhythmogenesis

    by Bo Han, Mark L. Trew, Callum M. Zgierski-Johnston

    Cardiac electrophysiological disorders, in particular arrhythmias, are a key cause of morbidity and mortality throughout the world. There are two basic requirements for arrhythmogenesis: an underlying substrate and a trigger. Altered conduction velocity (CV) provides a key substrate for arrhythmogenesis, with slowed CV increasing the probability of re-entrant arrhythmias by reducing the length scale over which re-entry can occur. In this review, we examine methods to measure cardiac CV in vivo and ex vivo, discuss underlying determinants of CV, and address how pathological variations alter CV, potentially increasing arrhythmogenic risk. Finally, we will highlight future directions both for methodologies to measure CV and for possible treatments to restore normal CV.


  • Impulse Data Models for the Inverse Problem of Electrocardiography

    by Tommy Peng, Avinash Malik, Laura R. Bear, Mark L. Trew

    Objective: To develop, train and test neural networks for predicting heart surface potentials (HSPs) from body surface potentials (BSPs). The method re-frames traditional inverse problems of electrocardiography into regression problems, constraining the solution space by decomposing signals with multidimensional Gaussian impulse basis functions. Methods: Impulse HSPs were generated with single Gaussian basis functions at discrete heart surface locations and projected to corresponding BSPs using a volume conductor torso model. Both BSP (inputs) and HSP (outputs) were mapped to regular 2D surface meshes and used to train a neural network. Predictive capabilities of the network were tested with unseen synthetic and experimental data. Results: A dense full connected single hidden layer neural network was trained to map body surface impulses to heart surface Gaussian basis functions for reconstructing HSP. Synthetic pulses moving across the heart surface were predicted from the neural network with root mean squared error of $9.1\pm 1.4$ %. Predicted signals were robust to noise up to 20 dB and errors due to displacement and rotation of the heart within the torso were bounded and predictable. A shift of the heart 40 mm toward the spine resulted in a 4% increase in signal feature localization error. The set of training impulse function data could be reduced, and prediction error remained bounded. Recorded HSPs from in-vitro pig hearts were reliably decomposed using space-time Gaussian basis functions. Activation times calculated from predicted HSPs for left-ventricular pacing had a mean absolute error of $10.4\pm 11.4$ ms. Other pacing scenarios were analyzed with similar success. Conclusion: Impulses from Gaussian basis functions are potentially an effective and robust way to train simple neural network data models for reconstructing HSPs from decomposed BSPs. Significance: The HSPs predicted by the neural network can be used to generate activation maps that non-invasively identify features of cardiac electrical dysfunction and can guide subsequent treatment options.


  • Closing the Loop: Validation of Implantable Cardiac Devices With Computational Heart Models

    by Weiwei Ai, Nitish D. Patel, Partha S. Roop, Avinash Malik, Mark L. Trew

    Cardiovascular Implantable Electronic Devices (CIEDs) are used extensively for treating life-threatening conditions such as bradycardia, atrioventricular block and heart failure. The complicated heterogeneous physical dynamics of patients provide distinct challenges to device development and validation. We address this problem by proposing a device testing framework within the in-silico closed-loop context of patient physiology. We develop an automated framework to validate CIEDs in closed-loop with a high-level physiologically based computational heart model. The framework includes test generation, execution and evaluation, which automatically guides an integrated stochastic optimization algorithm for exploration of physiological conditions. The results show that using a closed loop device-heart model framework can achieve high system test coverage, while the heart model provides clinically relevant responses. The simulated findings of pacemaker mediated tachycardia risk evaluation agree well with the clinical observations. Furthermore, we illustrate how device programming parameter selection affects the treatment efficacy for specific physiological conditions. This work demonstrates that incorporating model based closed-loop testing of CIEDs into their design provides important indications of safety and efficacy under constrained physiological conditions.


  • Shift of leading pacemaker site during reflex vagal stimulation and altered electrical source‐to‐sink balance

    by Jesse L. Ashton, Mark L. Trew, Ian J. LeGrice, David J. Paterson, Julian Fr. Paton, Anne M. Gillis, Bruce H. Smaill

    Key points: Vagal reflexes slow heart rate and can change where the heartbeat originates within the sinoatrial node (SAN). The mechanisms responsible for this process – termed leading pacemaker (LP) shift – have not been investigated fully. We used optical mapping to measure the effects of baroreflex, chemoreflex and carbachol on pacemaker entrainment and electrical conduction across the SAN. All methods of stimulation triggered shifts in LP site from the central SAN to one or two caudal pacemaker regions. These shifts were associated with reduced current generation capacity centrally and increased electrical load caudally. Previous studies suggest LP shift is a rate‐dependent phenomenon whereby acetylcholine slows central pacemaker rate disproportionately, enabling caudal cells that are less acetylcholine sensitive to assume control. However, our findings indicate the LP region is defined by both pacemaker rate and capacity to drive activation. Shifts in LP site provide an important homeostatic mechanism for rapid switches in heart rate. Reflex vagal activity causes abrupt heart rate slowing with concomitant caudal shifts of the leading pacemaker (LP) site within the sinoatrial node (SAN). However, neither the mechanisms responsible nor their dynamics have been investigated fully. Therefore, the objective of this study was to elucidate the mechanisms driving cholinergic LP shift. Optical maps of right atrial activation were acquired in a rat working heart–brainstem preparation during baroreflex and chemoreflex stimulation or with carbachol. All methods of stimulation triggered shifts in LP site from the central SAN to caudal pacemaker regions, which were positive for HCN4 and received uniform cholinergic innervation. During baroreflex onset, the capacity of the central region to drive activation declined with a decrease in amplitude and gradient of optical action potentials (OAPs) in the surrounding myocardium. Accompanying this decline, there was altered entrainment in the caudal SAN as shown by decreased conduction velocity, OAP amplitude, gradient and activation time. Atropine abolished these responses. Chemoreflex stimulation produced similar effects but central capacity to drive activation was preserved before the LP shift. In contrast, carbachol produced a prolonged period of reduced capacity to drive and altered entrainment. Previous studies suggest LP shift is a rate‐dependent phenomenon whereby acetylcholine slows central pacemaker rate disproportionately, enabling caudal cells that are less acetylcholine sensitive to assume control. Our findings indicate that cholinergic LP shifts are also determined by altered electrical source‐to‐sink balance in the SAN. We conclude that the LP region is defined by both rate and capacity to drive atrial activation.


  • Cardiac Electrical Modeling for Closed-Loop Validation of Implantable Devices

    by Weiwei Ai, Nitish Dhirubhai Patel, Partha S. Roop, Avinash Malik, Mark L. Trew

    Objective: Evaluating and testing cardiac electrical devices in a closed-physiologic-loop can help design safety, but this is rarely practical or comprehensive. Furthermore, in-silico closed-loop testing with biophysical computer models cannot meet the requirements of time-critical cardiac device systems, while simplified models meeting time-critical requirements may not have the necessary dynamic features. We propose a new high-level (abstracted) physiologically-based computational heart model that is time-critical and dynamic. Methods: The model comprises cardiac regional cellular-electrophysiology types connected by a path model along a conduction network. The regional electrophysiology and paths are modeled with hybrid automata that capture non-linear dynamics, such as action potential and conduction velocity restitution and overdrive suppression. The hierarchy of pacemaker functions is incorporated to generate sinus rhythms, while abnormal automaticity can be introduced to form a variety of arrhythmias such as escape ectopic rhythms. Model parameters are calibrated using experimental data and prior model simulations. Conclusion: Regional electrophysiology and paths in the model match human action potentials, dynamic behavior and cardiac activation sequences. Connected in closed-loop with a pacing device in DDD mode, the model generates complex arrhythmia such as atrioventricular nodal reentry tachycardia. Such device-induced outcomes have been observed clinically and we can establish the key physiological features of the heart model that influence the device operation. Significance: These findings demonstrate how an abstract heart model can be used for device validation and to design personalized treatment.