Mehmet Çayören
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mehmet Çayören has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
- Ibrahim Akduman
Electronics and Communication Engineering Department, Istanbul Technical University, 34469 Istanbul, Turkey
10 shared publications Ibrahim Akduman
Department of Electronics and Communication Engineering Istanbul Technical University Maslak Istanbul Turkey
8 shared publications- Mehmet Nuri Akinci
Istanbul Technical University
8 shared publications - Ismail Dilman
Department of Electronics and Communication Engineering, Istanbul Technical University, Istanbul, Turkey
5 shared publications Egemen Bilgin
Department of Electrical and Electronics Engineering MEF University Maslak Istanbul Turkey
4 shared publications- Lorenzo Crocco
Institute for the Electromagnetic Sensing of the Environment, National Research Council of Italy, Naples, Italy
4 shared publications
Latest Publications
- 30 June 2023
- Published by Springer Nature
- p. 273-292
SAFE—Microwave Imaging Device for Breast Cancer Early Screening and Diagnostics
- 30 June 2023
- Published by Springer Nature
- p. 273-292
SAFE—Microwave Imaging Device for Breast Cancer Early Screening and Diagnostics
- 14 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-8
Maximum Likelihood Estimation of Debye Relaxation Parameters With Open-Ended Coaxial Probes
In this paper, we present a new method to measure the complex dielectric permittivity of materials-under-test with an open-ended coaxial probe. The method, which explicitly takes measurement noise into account to enhance the stability of the measurements, is formulated based on the maximum likelihood estimation of the Debye parameters from calibrated reflection measurements performed at the aperture of the probe. In particular, the measurement noises at different frequencies are approximated with independent Gaussian distributions. To estimate the mean and the standard deviation of the mentioned probability distributions at each frequency, the differences among repetitive measurements of a reference sample are analyzed. Later, these statistical distributions are enforced into a cost functional to derive an optimization scheme based on the maximum likelihood estimation. Finally, the cost functional is iteratively minimized with a second-order Newton-based technique to retrieve the Debye relaxation parameters of a material. We further experimentally verified the method with various liquid samples and the accuracy of the obtained results is compared with the previous works.
- 14 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-8
Maximum Likelihood Estimation of Debye Relaxation Parameters With Open-Ended Coaxial Probes
In this paper, we present a new method to measure the complex dielectric permittivity of materials-under-test with an open-ended coaxial probe. The method, which explicitly takes measurement noise into account to enhance the stability of the measurements, is formulated based on the maximum likelihood estimation of the Debye parameters from calibrated reflection measurements performed at the aperture of the probe. In particular, the measurement noises at different frequencies are approximated with independent Gaussian distributions. To estimate the mean and the standard deviation of the mentioned probability distributions at each frequency, the differences among repetitive measurements of a reference sample are analyzed. Later, these statistical distributions are enforced into a cost functional to derive an optimization scheme based on the maximum likelihood estimation. Finally, the cost functional is iteratively minimized with a second-order Newton-based technique to retrieve the Debye relaxation parameters of a material. We further experimentally verified the method with various liquid samples and the accuracy of the obtained results is compared with the previous works.
- Open Access
- 13 December 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (12) , 3151
Gradient-Boosting Algorithm for Microwave Breast Lesion Classification—SAFE Clinical Investigation
(1) Background: Microwave breast imaging (MBI) is a promising breast-imaging technology that uses harmless electromagnetic waves to radiate the breast and assess its internal structure. It utilizes the difference in dielectric properties of healthy and cancerous tissue, as well as the dielectric difference between different cancerous tissue types to identify anomalies inside the breast and make further clinical predictions. In this study, we evaluate the capability of our upgraded MBI device to provide breast tissue pathology. (2) Methods: Only patients who were due to undergo biopsy were included in the study. A machine learning (ML) approach, namely Gradient Boosting, was used to understand information from the frequency spectrum, collected via SAFE, and provide breast tissue pathology. (3) Results: A total of 54 patients were involved in the study: 29 of them had benign and 25 had malignant findings. SAFE acquired 20 true-positive, 24 true-negative, 4 false-positive and 4 false-negative findings, achieving the sensitivity, specificity and accuracy of 80%, 83% and 81%, respectively. (4) Conclusions: The use of harmless tissue radiation indicates that SAFE can be used to provide the breast pathology of women of any age without safety restrictions. Results indicate that SAFE is capable of providing breast pathology at a high rate, encouraging further clinical investigations.
- 13 December 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (12) , 3151
Open AccessGradient-Boosting Algorithm for Microwave Breast Lesion Classification—SAFE Clinical Investigation
(1) Background: Microwave breast imaging (MBI) is a promising breast-imaging technology that uses harmless electromagnetic waves to radiate the breast and assess its internal structure. It utilizes the difference in dielectric properties of healthy and cancerous tissue, as well as the dielectric difference between different cancerous tissue types to identify anomalies inside the breast and make further clinical predictions. In this study, we evaluate the capability of our upgraded MBI device to provide breast tissue pathology. (2) Methods: Only patients who were due to undergo biopsy were included in the study. A machine learning (ML) approach, namely Gradient Boosting, was used to understand information from the frequency spectrum, collected via SAFE, and provide breast tissue pathology. (3) Results: A total of 54 patients were involved in the study: 29 of them had benign and 25 had malignant findings. SAFE acquired 20 true-positive, 24 true-negative, 4 false-positive and 4 false-negative findings, achieving the sensitivity, specificity and accuracy of 80%, 83% and 81%, respectively. (4) Conclusions: The use of harmless tissue radiation indicates that SAFE can be used to provide the breast pathology of women of any age without safety restrictions. Results indicate that SAFE is capable of providing breast pathology at a high rate, encouraging further clinical investigations.
- 29 October 2022
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 61 (1) , 33-43
Monitoring of intracerebral hemorrhage with a linear microwave imaging algorithm
Intracerebral hemorrhage is a life-threatening condition where conventional imaging modalities such as CT and MRI are indispensable in diagnosing. Neverthe
- 29 October 2022
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 61 (1) , 33-43
Monitoring of intracerebral hemorrhage with a linear microwave imaging algorithm
Intracerebral hemorrhage is a life-threatening condition where conventional imaging modalities such as CT and MRI are indispensable in diagnosing. Neverthe
- 6 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 70 (11) , 5105-5115
A Guideline for Complex Permittivity Retrieval of Tissue-Mimicking Phantoms From Open-Ended Coaxial Probe Response With Deep Learning
In this work, we proposed a general guideline and a technique for retrieving the complex permittivities (CPs) of material under test (MUT) from the measured reflection coefficients (RCs) obtained with the openended coaxial probe (OECP) through a deep learning model (DLM). Particularly, lossy materials such as phantoms mimicking the biological tissues are considered as MUT in this study. The dataset used to design (train, validate, and test) the DLM is synthetically generated using the relationship between the CPs of the MUT, namely, admittance model, and the fourpole Cole–Cole relaxation model. Moreover, the technique is implemented to accurately predict the CPs of biological tissues with real measured RCs’ data from 0.5 to 20 GHz with a 50-MHz resolution. This technique eliminates the need to physically perform measurements required to create the dataset for DLM and it can be easily implemented for realtime CPs’ measurement of biological tissues. The designed DLM is initially trained, validated, and tested with 80%, 10%, and 10% of the total generated synthetic dataset, respectively. A percent relative error of 1.5 $\pm$ 0.88% is obtained for CPs’ prediction at the test stage. Furthermore, DLM is tested with real RCs’ data measured from four different tissuemimicking phantoms: skin, muscle, blood, and fat. Predicted CPs from DLM are compared with the CPs’ results obtained from a commercially available OECP measurement kit. A (mean) $\pm$ (std.dev) percent relative error ranging from 2.08 $\pm$ 0.4 to 10.84 $\pm$ 2.43 within the frequency band of interest was obtained after comparison.
- 6 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 70 (11) , 5105-5115
A Guideline for Complex Permittivity Retrieval of Tissue-Mimicking Phantoms From Open-Ended Coaxial Probe Response With Deep Learning
In this work, we proposed a general guideline and a technique for retrieving the complex permittivities (CPs) of material under test (MUT) from the measured reflection coefficients (RCs) obtained with the openended coaxial probe (OECP) through a deep learning model (DLM). Particularly, lossy materials such as phantoms mimicking the biological tissues are considered as MUT in this study. The dataset used to design (train, validate, and test) the DLM is synthetically generated using the relationship between the CPs of the MUT, namely, admittance model, and the fourpole Cole–Cole relaxation model. Moreover, the technique is implemented to accurately predict the CPs of biological tissues with real measured RCs’ data from 0.5 to 20 GHz with a 50-MHz resolution. This technique eliminates the need to physically perform measurements required to create the dataset for DLM and it can be easily implemented for realtime CPs’ measurement of biological tissues. The designed DLM is initially trained, validated, and tested with 80%, 10%, and 10% of the total generated synthetic dataset, respectively. A percent relative error of 1.5 $\pm$ 0.88% is obtained for CPs’ prediction at the test stage. Furthermore, DLM is tested with real RCs’ data measured from four different tissuemimicking phantoms: skin, muscle, blood, and fat. Predicted CPs from DLM are compared with the CPs’ results obtained from a commercially available OECP measurement kit. A (mean) $\pm$ (std.dev) percent relative error ranging from 2.08 $\pm$ 0.4 to 10.84 $\pm$ 2.43 within the frequency band of interest was obtained after comparison.
- 18 August 2022
- Published by Wiley in Medical Physics
- Vol. 49 (10) , 6599-6608
Single‐slice microwave imaging of breast cancer by reverse time migration
Purpose Microwave imaging of breast cancer is considered and a new microwave imaging prototype including the imaging algorithm, the antenna array, and the measurement configuration is presented. The prototype aims to project the geometrical features of the anomalies inside the breast to a single-slice image at the coronal plane depending on the complex dielectric permittivity variation among the tissues to aid the diagnosis . Methods The imaging prototype uses a solid cylindrical dielectric platform, where a total of 24 optimized Vivaldi antennas are embedded inside to form a uniform circular antenna array. The center of the platform is carved to create a hollow part for placement of the breast and the multistatic, microwave scattering parameters are collected with the antenna array around the hollow center. The dielectric platform further enhances the microwave impedance matching against the breast fat tissue and preserves the vertical polarization during the measurements. In the imaging phase, a computationally efficient inverse electromagnetic scattering method-reverse time migration (RTM)-is considered and adapted in terms of scattering parameters to comply with the actual measurements. Results The prototype system is experimentally tested against tissue-mimicking breast phantoms with realistic dielectric permittivity profiles. The reconstructed single-slice images accurately determined the locations and the geometrical extents of the tumor phantoms. These experiments not only verified the microwave imaging prototype but also provided the first experimental results of the imaging algorithm. Conclusions The presented prototype system implementing the RTM method is capable of reconstructing single-slice, nonanatomical images, where the hotspots correspond to the geometrical projections of the anomalies inside the breast.
- 18 August 2022
- Published by Wiley in Medical Physics
- Vol. 49 (10) , 6599-6608
Single‐slice microwave imaging of breast cancer by reverse time migration
Purpose Microwave imaging of breast cancer is considered and a new microwave imaging prototype including the imaging algorithm, the antenna array, and the measurement configuration is presented. The prototype aims to project the geometrical features of the anomalies inside the breast to a single-slice image at the coronal plane depending on the complex dielectric permittivity variation among the tissues to aid the diagnosis . Methods The imaging prototype uses a solid cylindrical dielectric platform, where a total of 24 optimized Vivaldi antennas are embedded inside to form a uniform circular antenna array. The center of the platform is carved to create a hollow part for placement of the breast and the multistatic, microwave scattering parameters are collected with the antenna array around the hollow center. The dielectric platform further enhances the microwave impedance matching against the breast fat tissue and preserves the vertical polarization during the measurements. In the imaging phase, a computationally efficient inverse electromagnetic scattering method-reverse time migration (RTM)-is considered and adapted in terms of scattering parameters to comply with the actual measurements. Results The prototype system is experimentally tested against tissue-mimicking breast phantoms with realistic dielectric permittivity profiles. The reconstructed single-slice images accurately determined the locations and the geometrical extents of the tumor phantoms. These experiments not only verified the microwave imaging prototype but also provided the first experimental results of the imaging algorithm. Conclusions The presented prototype system implementing the RTM method is capable of reconstructing single-slice, nonanatomical images, where the hotspots correspond to the geometrical projections of the anomalies inside the breast.
- 31 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-7
A Method to Measure Complex Dielectric Permittivity With Open-Ended Coaxial Probes
This work presents a new method to measure the complex dielectric permittivity (CDP) variation of materials under test (MUTs) with open-ended coaxial probes. The CDP variation of an MUT is a continuous function of frequency as modeled with various dielectric relaxation models. Hence, the accuracy and the repeatability of CDP measurements can be improved by enforcing such spectral continuity. Here, we derive a new formulation that explicitly enforces the spectral continuity via the Debye relaxation model. In particular, we construct a cost functional based on an admittance integral at the tip of an open-ended coaxial probe. The Debye model parameters are substituted into the admittance integral to form a set of nonlinear equations. Later, these equations are iteratively minimized by a Gauss–Newton-based minimization scheme, for measured reflection coefficients when the tip of the probe is in contact with the MUT. The presented method differs from the conventional CDP measurement techniques in two aspects. First, the method looks for a global solution across the investigated frequency spectrum instead of solving CDP values individually at each frequency step. Second, the Debye parameters are directly retrieved without any data-fitting. The presented method is experimentally verified with various liquid samples, and the accuracy of obtained results is compared against the literature.
- 31 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-7
A Method to Measure Complex Dielectric Permittivity With Open-Ended Coaxial Probes
This work presents a new method to measure the complex dielectric permittivity (CDP) variation of materials under test (MUTs) with open-ended coaxial probes. The CDP variation of an MUT is a continuous function of frequency as modeled with various dielectric relaxation models. Hence, the accuracy and the repeatability of CDP measurements can be improved by enforcing such spectral continuity. Here, we derive a new formulation that explicitly enforces the spectral continuity via the Debye relaxation model. In particular, we construct a cost functional based on an admittance integral at the tip of an open-ended coaxial probe. The Debye model parameters are substituted into the admittance integral to form a set of nonlinear equations. Later, these equations are iteratively minimized by a Gauss–Newton-based minimization scheme, for measured reflection coefficients when the tip of the probe is in contact with the MUT. The presented method differs from the conventional CDP measurement techniques in two aspects. First, the method looks for a global solution across the investigated frequency spectrum instead of solving CDP values individually at each frequency step. Second, the Debye parameters are directly retrieved without any data-fitting. The presented method is experimentally verified with various liquid samples, and the accuracy of obtained results is compared against the literature.
- 11 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 70 (6) , 4810-4817
Quasi-Newton-Based Inversion Method for Determining Complex Dielectric Permittivity of 3-D Inhomogeneous Objects
We present a new method for determining the complex dielectric permittivity profile of 3-D inhomogeneous dielectric objects from measurements of the scattered electric field vectors in the frequency domain. The method is formulated as a minimization of a cost function defined in terms of electric field integral equations known as the object and data equations. Instead of an unknown object function containing the electromagnetic parameters of the dielectrics, the contrast sources induced within the scatterers are designated as the unknowns of the inversion scheme to avoid solving the forward scattering problem at each step. Later, the minimization of the cost function is achieved via a limited-memory quasi-Newton scheme, based on the Broyden–Fletcher–Goldfarb–Shanno (BFGS) formula, which iteratively updates the Hessian matrix estimation. The numerical results with the simulated and experimental scattered electric fields demonstrate that the presented method is capable of reconstructing scatterers with complex shapes.
- 11 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 70 (6) , 4810-4817
Quasi-Newton-Based Inversion Method for Determining Complex Dielectric Permittivity of 3-D Inhomogeneous Objects
We present a new method for determining the complex dielectric permittivity profile of 3-D inhomogeneous dielectric objects from measurements of the scattered electric field vectors in the frequency domain. The method is formulated as a minimization of a cost function defined in terms of electric field integral equations known as the object and data equations. Instead of an unknown object function containing the electromagnetic parameters of the dielectrics, the contrast sources induced within the scatterers are designated as the unknowns of the inversion scheme to avoid solving the forward scattering problem at each step. Later, the minimization of the cost function is achieved via a limited-memory quasi-Newton scheme, based on the Broyden–Fletcher–Goldfarb–Shanno (BFGS) formula, which iteratively updates the Hessian matrix estimation. The numerical results with the simulated and experimental scattered electric fields demonstrate that the presented method is capable of reconstructing scatterers with complex shapes.
- 2 October 2021
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 82, 102051
Flow monitoring by microwave imaging inside a cuboid cavity: Theory and numerical feasibility analysis
- 2 October 2021
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 82, 102051
Flow monitoring by microwave imaging inside a cuboid cavity: Theory and numerical feasibility analysis