IDIsmail Dilman

Ismail Dilman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ismail Dilman has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Maximum Likelihood Estimation of Debye Relaxation Parameters With Open-Ended Coaxial Probes

    by Ismail Dilman, Mehmet Çayören, Mehmet Nuri Akinci

    In this paper, we present a new method to measure the complex dielectric permittivity of materials-under-test with an open-ended coaxial probe. The method, which explicitly takes measurement noise into account to enhance the stability of the measurements, is formulated based on the maximum likelihood estimation of the Debye parameters from calibrated reflection measurements performed at the aperture of the probe. In particular, the measurement noises at different frequencies are approximated with independent Gaussian distributions. To estimate the mean and the standard deviation of the mentioned probability distributions at each frequency, the differences among repetitive measurements of a reference sample are analyzed. Later, these statistical distributions are enforced into a cost functional to derive an optimization scheme based on the maximum likelihood estimation. Finally, the cost functional is iteratively minimized with a second-order Newton-based technique to retrieve the Debye relaxation parameters of a material. We further experimentally verified the method with various liquid samples and the accuracy of the obtained results is compared with the previous works.


  • Monitoring of intracerebral hemorrhage with a linear microwave imaging algorithm

    by İsMail Dilman, Egemen Bilgin, Mehmet Nuri Akıncı, Sema Coşğun, Semih Doğu, Mehmet Çayören, İbRahim Akduman

    Intracerebral hemorrhage is a life-threatening condition where conventional imaging modalities such as CT and MRI are indispensable in diagnosing. Neverthe


  • A Guideline for Complex Permittivity Retrieval of Tissue-Mimicking Phantoms From Open-Ended Coaxial Probe Response With Deep Learning

    by Sulayman Joof, Cemanur Aydinalp, Ismail Dilman, Mehmet Nuri Akinci, Tuba Yilmaz, Mehmet Cayoren, Ibrahim Akduman

    In this work, we proposed a general guideline and a technique for retrieving the complex permittivities (CPs) of material under test (MUT) from the measured reflection coefficients (RCs) obtained with the openended coaxial probe (OECP) through a deep learning model (DLM). Particularly, lossy materials such as phantoms mimicking the biological tissues are considered as MUT in this study. The dataset used to design (train, validate, and test) the DLM is synthetically generated using the relationship between the CPs of the MUT, namely, admittance model, and the fourpole Cole–Cole relaxation model. Moreover, the technique is implemented to accurately predict the CPs of biological tissues with real measured RCs’ data from 0.5 to 20 GHz with a 50-MHz resolution. This technique eliminates the need to physically perform measurements required to create the dataset for DLM and it can be easily implemented for realtime CPs’ measurement of biological tissues. The designed DLM is initially trained, validated, and tested with 80%, 10%, and 10% of the total generated synthetic dataset, respectively. A percent relative error of 1.5 $\pm$ 0.88% is obtained for CPs’ prediction at the test stage. Furthermore, DLM is tested with real RCs’ data measured from four different tissuemimicking phantoms: skin, muscle, blood, and fat. Predicted CPs from DLM are compared with the CPs’ results obtained from a commercially available OECP measurement kit. A (mean) $\pm$ (std.dev) percent relative error ranging from 2.08 $\pm$ 0.4 to 10.84 $\pm$ 2.43 within the frequency band of interest was obtained after comparison.


  • A Method to Measure Complex Dielectric Permittivity With Open-Ended Coaxial Probes

    by Ismail Dilman, Mehmet Nuri Akinci, Tuba Yilmaz, Mehmet Cayoren, Ibrahim Akduman

    This work presents a new method to measure the complex dielectric permittivity (CDP) variation of materials under test (MUTs) with open-ended coaxial probes. The CDP variation of an MUT is a continuous function of frequency as modeled with various dielectric relaxation models. Hence, the accuracy and the repeatability of CDP measurements can be improved by enforcing such spectral continuity. Here, we derive a new formulation that explicitly enforces the spectral continuity via the Debye relaxation model. In particular, we construct a cost functional based on an admittance integral at the tip of an open-ended coaxial probe. The Debye model parameters are substituted into the admittance integral to form a set of nonlinear equations. Later, these equations are iteratively minimized by a Gauss–Newton-based minimization scheme, for measured reflection coefficients when the tip of the probe is in contact with the MUT. The presented method differs from the conventional CDP measurement techniques in two aspects. First, the method looks for a global solution across the investigated frequency spectrum instead of solving CDP values individually at each frequency step. Second, the Debye parameters are directly retrieved without any data-fitting. The presented method is experimentally verified with various liquid samples, and the accuracy of obtained results is compared against the literature.


  • Open Access

    Characterization of Open-Ended Coaxial Probe Sensing Depth with Respect to Aperture Size for Dielectric Property Measurement of Heterogeneous Tissues

    by Cemanur Aydinalp, Sulayman Joof, Ismail Dilman, Ibrahim Akduman, Tuba Yilmaz

    The open-ended coaxial probe (OECP) method is frequently used for the microwave dielectric property (DP) characterization of high permittivity and conductivity materials due to inherent advantages including minimal sample preparation requirements and broadband measurement capabilities. However, the OECP method is known to suffer from high measurement error. One well-known contributor to the high error rates is tissue heterogeneity, which can potentially be managed through the selection of a probe with a proper sensing depth (SD). The SD of the OECP is dependent on many factors including sample DPs and probe aperture diameter. Although the effects of sample DPs on SD have been investigated to some extent in the literature, the probe aperture diameters, particularly small diameters, have not been fully explored. To this end, the SDs of probes with three different apertures (0.5, 0.9 and 2.2 mm-diameters) were analyzed in this study. Probes’ SDs were first investigated with simulations using a double-layered sample configuration (skin tissue and olive oil). Next, experiments were performed using a commercial OECP with a 2.2 mm aperture diameter. The SD was categorized based on 5%, 20% and 80% DP change. Among these threshold values, a 5% DP change was selected as the benchmark for SD categorization. The findings suggest that probes with a smaller aperture size and correspondingly smaller SD should be utilized when measuring the DPs of thin and multilayered samples, such as healthy and diseased skin tissues, to increase the measurement accuracy.


  • The Capability of Truncated Singular Value Decomposition Method for Through the Wall Microwave Imaging

    by Semih Dogu, Hadi Alidoustaghdam, İsmail Dilman, Mehmet Nuri Akinci

    In this study, a truncated singular value decomposition (TSVD) based computationally efficient through the wall imaging (TWI) is addressed. Mainly, two different scenarios with identical and non-identical multiple scatterers behind the wall have been considered. The scattered data are processed with special scheme in order to improve quality of the results and measurements are performed at four different frequencies. Next, effects of selecting truncation threshold in TSVD methods are analyzed and a detailed quantitative comparison is provided to demonstrate capabilities of these TSVD methods over selection of truncation threshold.


  • Feasibility of brain stroke imaging with microwaves

    by İsmail Dilman, Ugur Yildirim, Sema Cosgun, Semih Dogu, Mehmet Cayoren, Ibrahim Akduman

    This paper investigates feasibility of detection of blooded area in a realistic head phantom with microwave imaging. Realistic phantom is illuminated by 36 line sources and the scattering field data is calculated numerically with method of moments. Additive white Gaussian noise with 20 dB is added for more realistic scenario. Contrast Source Inversion method is used to reconstruct the blooded area. Simulations are done at different operating frequencies of 500 MHz, 800 MHz and 1000 MHz. Moreover, results either with electrically different background mediums or free space are discussed in this study. The numerical results show that it is possible to determine the square shape blooded area with size about 2.6cm × 2.6cm between the 800-1000Mhz frequency range in the dielectric matching medium.