JHJonas Henriksson

Jonas Henriksson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jonas Henriksson has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Integrated Long-Range Thermal Bimorph Actuators for Parallelizable Bio-AFM Applications

    by Jonas Henriksson, Maurizio Rosario Gullo, Juergen Brugger

    Atomic force microscope (AFM)-based cell force spectroscopy is an emerging research method that has already enhanced our understanding of the structural changes that take place in a cell as it becomes cancerous. However, the method is limited as it is not time-efficient in its current state of development. This paper presents the fabrication of an integrated long-range thermal bimorph actuator that controls the z-position of an AFM cantilever in liquid. Multiplied in arrays, such individually actuated probes can parallelize cell force spectroscopy measurements, thereby drastically reducing the time per measured cell. The need to accommodate differences in tip-sample distance implies an individual device actuation range of ${\geq}{\rm 10}~\mu{\rm m}$ out-of-plane. In addition, any cross-talk, i.e., between actuators or between the actuator and the force sensor, must be minimized. To meet these requirements, we design and fabricate a novel thermal bimorph actuator that is paired with a force sensing cantilever. In order to keep temperatures in a bio-friendly range, the design is optimized for high thermomechanical sensitivity. Finite element model simulations confirmed that the surrounding liquid constitutes a large thermal reservoir that absorbs the generated heat without any dramatic temperature increase. Furthermore, given that a cell substrate material of high thermal conductivity is chosen, e.g., Si, the thermal coupling between the cell and the substrate, dominates over that between the cell and the actuator. Suspended silicon nitride structures with platinum electrodes are microfabricated through standard techniques. The finalized actuator is able to displace the cantilever out-of-plane by ${\sim}{\rm 17}~\mu{\rm m}$ in air, corresponding well to estimations.


  • Integrated long-range thermal bimorph actuators for parallelizable Bio-AFM applications

    by J. Henriksson, M. Gullo, J. Brugger

    This paper presents the fabrication of an integrated long-range thermal bimorph actuator that controls the z-position of an AFM cantilever in liquid. Multiplied in an array, such individually actuated probes can parallelize cell force spectroscopy measurements, thereby drastically reducing the time needed per measured cell. This particular approach implicates the need for devices with an individual actuation range of more than 10 μm out of plane. In addition, any crosstalk, i.e. between actuators or between the actuator and the force sensor, must be minimized. To meet these requirements, we designed and fabricated a novel thermal bimorph actuator that was incorporated with force sensing cantilevers. To be nonhazardous to cells, the design was optimized for high thermo-mechanical sensitivity in order to keep the temperatures as low as possible. FEM simulations confirmed that the surrounding liquid constitutes a very large thermal reservoir that absorbs generated heat, leading to a highly localized temperature elevation. Suspended silicon nitride structures with platinum electrodes were micro-fabricated through standard techniques. The finalized actuator was able to displace the cantilever out of plane by about 17 μm in air. An effective passivation layer was created through a parylene deposition, allowing the actuator to function in water.


  • Ultra-low power hydrogen sensing based on a palladium-coated nanomechanical beam resonator

    by Jonas Henriksson, Luis Guillermo Villanueva, Juergen Brugger

    Hydrogen sensing is essential to ensure safety in near-future zero-emission fuel cell powered vehicles. Here, we present a novel hydrogen sensor based on the resonant frequency change of a nanoelectromechanical clamped–clamped beam. The beam is coated with a Pd layer, which expands in the presence of H2, therefore generating a stress build-up that causes the frequency of the device to drop. The devices are able to detect H2 concentrations below 0.5% within 1 s of the onset of the exposure using only a few hundreds of pW of power, matching the industry requirements for H2 safety sensors. In addition, we investigate the strongly detrimental effect that relative humidity (RH) has on the Pd responsivity to H2, showing that the response is almost nullified at about 70% RH. As a remedy for this intrinsic limitation, we applied a mild heating current through the beam, generating a few μW of power, whereby the responsivity of the sensors is fully restored and the chemo-mechanical process is accelerated, significantly decreasing response times. The sensors are fabricated using standard processes, facilitating their eventual mass-production.


  • Ultra-low power palladium-coated MEMS resonators for hydrogen detection under ambient conditions

    by J. Henriksson, L. G. Villanueva, J. Brugger

    We present a novel approach for hydrogen gas detection, based on palladium-coated micromechanical resonators. A sequence of thin film techniques allows the large-scale parallel fabrication of free-standing beams, from a counter-electrode by a mesoscopic air gap. The readout principle has been confirmed. The device manifests a resonance frequency drop from 6.5 to 3 MHz as it is exposed to 4% of H2 during 15 s. The sensor responds within a few seconds to hydrogen gas and has a power consumption of about 10 pW. Preliminary results suggest that this technique can detect very minute concentrations.