ASAnnette Sperduti

Annette Sperduti

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Annette Sperduti has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Communicating with Emotional Patients: Thoughts, Skills, and Influencing Factors for Ontario Radiation Therapists

    by Lorraine Hulley, Angela Cashell, Carina Feuz, Anne Jessop, Annette Sperduti, Elen Moyo, Tara Rosewall


  • Dosimetric impacts on skin toxicity for patients using topical agents and dressings during radiotherapy

    by Karen Tse, Lyndon Morley, Angela Cashell, Annette Sperduti, Maurene McQuestion, James C. L. Chow

    Background and purpose: Skin care practices for radiotherapy patients are complicated by dosimetric concerns. This study measures the effect on skin dose of various topical agents and dressings.Materials and methods: Superficial doses were measured under 17 topical agents and dressings and three clinical materials for reference. Dose was measured using a MOSFET detector under a 1 mm polymethyl methacrylate slab, with 6 MV photon beams at 100 cm source to surface distance.Results: Relative skin dose under reference materials was 128% (thermoplastic mask), 158% (5 mm bolus) and 171% (10 mm bolus). Under a realistic application of topical agent (0·5 mm), relative skin doses were 106–111%. All dry dressings yielded relative dose of ≤111%; two wet dressings yielded higher relative doses (133 and 141%).Conclusions: Under clinically relevant conditions, no cream, gel or dry dressing increased the skin dose beyond that seen with a thermoplastic mask. Dressings soaked with water produced less skin dose than 5 mm bolus. This may be unacceptable if wet dressings are in place for the majority of the treatment course. Our results suggest that skin care practices should not be limited by dosimetric concerns when using a 6 MV photon beam.


  • Evaluating the relevance of dosimetric considerations to patient instructions regarding skin care during radiation therapy

    by Lyndon Morley, Angela Cashell, Annette Sperduti, Maurene McQuestion, James C. L. Chow

    Introduction: Patient teaching in radiation therapy may include restrictions on applying skin products owing to concerns that the presence of such materials may increase skin dose. These restrictions may create unnecessarily complicated and conflicting self-care instructions.Purpose: To determine what thickness of skin product is necessary to produce a clinically meaningful dose increase to the skin, and provide recommendations for evidence-based patient instructions.Methods: Dosimetric measurements and Monte Carlo simulations were used to calculate skin dose under 0–1·5 mm thicknesses of two common classes of skin product for a variety of treatment geometries. The thickness of product required to produce a clinically significant dose increase to the skin was determined.Results: The thickness of product required to create a clinically meaningful dose increase was >0·7 mm for 10 × 10 cm2fields and >1·5 mm for 1 × 1 cm2fields. A typical application of product would be only 0·3 mm.Conclusion: It seems unrealistic to anticipate patients using sufficiently large quantities of skin product to be of clinical concern. We therefore recommend that there are no dosimetric reasons to restrict the use of these types of skin products during radiation therapy for common treatment scenarios.


  • A feasibility study of an internal control methodology using hydrocortisone cream for the management of skin reactions in patients receiving radical radiation therapy for cancers of the head and neck

    by A. Sperduti, A. Cashell, C. Rocca, A. Hirji, S. Billingsley, J. Waldron, G. Pond

    Background: The literature on the evaluation of the management of radiation-induced dermatitis demonstrates the methodological difficulties of studying this subject. Therefore, the feasibility of a methodology whereby the patient acted as their own control was used to study acute cutaneous side effects for head and neck radiotherapy patients using 1% hydrocortisone cream (HC).Methods: Twenty patients were asked to apply Hyderm (1% hydrocortisone) cream twice daily to one side of the treatment area (either right or left) beginning on day one of radiation therapy and ending 2 weeks post-radiation therapy. The centres standard skin care protocol using mild soap and water and no creams was used on the other side of the neck. Once weekly the patients were assessed and scored using the Radiation-Induced Skin Reaction Scale and Radiotherapy and Oncology Group assessment scales and the patient completed a symptom scoring scale each week was a baseline assessment undertaken before they started treatment. To document compliance with study instructions, patients were asked to keep a calendar indicating when they applied the cream and to which side, and this was collected by clinical staff.Results: At the conclusion of the study, 12 patients were enrolled. During the course of the study it became increasingly obvious that the side to which patients were applying the Hyderm scored higher on the assessment scale, indicating an increased skin reaction than the control side. This was confirmed with the photographs and patient symptom scale. As a result of these increased reactions, the study ceased accrual earlier than anticipated and all patients were advised to discontinue Hyderm use.Conclusion: The increase in skin toxicity was unexpected, particularly as the institutional standard of care recommended the use of HC as treatment for radiation dermatitis. The number of patients in the study was too small to make conclusive statements about the efficacy of HC. We were able to confirm the feasibility of using an internal control methodology in these patients. Compliance results indicate the skin care instructions were clearly written and patients were able to follow them.