Angela Cashell
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Angela Cashell has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Annette Sperduti
Radiation Medicine Program, Princess Margaret Cancer Centre, University Health Network, Toronto, Ontario, Canada
4 shared publications - Lyndon Morley
Princess Margaret Cancer Centre
4 shared publications - Tara Rosewall
Radiation Medicine Program, Princess Margaret Cancer Center, Toronto, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Canada
4 shared publications Maurene McQuestion
Princess Margaret Cancer Centre
3 shared publications- Winnie Li
Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON, Canada
3 shared publications Amanda Bolderston
British Columbia Cancer Agency
2 shared publications
Latest Publications
- Open Access
- 1 June 2019
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 50 (2) , S11
Increased Automation and Artificial Intelligence in Radiation Therapy Clinical Practice: A Qualitative Exploration of Radiation Therapist Perceptions
- 1 June 2019
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 50 (2) , S11
Open AccessIncreased Automation and Artificial Intelligence in Radiation Therapy Clinical Practice: A Qualitative Exploration of Radiation Therapist Perceptions
- 1 September 2018
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 49 (3) , S14
Building Radiation Therapist IGRT Expertise Through Challenging Case-Based Rounds
- 1 September 2018
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 49 (3) , S14
Building Radiation Therapist IGRT Expertise Through Challenging Case-Based Rounds
- 1 March 2018
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 49 (1) , S8
Evidence or Tradition? A Canadian Review of the Management of Radiation Induced Skin Reactions
- 1 March 2018
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 49 (1) , S8
Evidence or Tradition? A Canadian Review of the Management of Radiation Induced Skin Reactions
- 1 December 2016
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 47 (4) , 323-328
Exploring the Experiences of Left-Sided Breast Cancer Patients Receiving Radiation Therapy Using the Active Breathing Coordinator
- 1 December 2016
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 47 (4) , 323-328
Exploring the Experiences of Left-Sided Breast Cancer Patients Receiving Radiation Therapy Using the Active Breathing Coordinator
- 1 December 2016
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 47 (4) , 315-322
Communicating with Emotional Patients: Thoughts, Skills, and Influencing Factors for Ontario Radiation Therapists
- 1 December 2016
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 47 (4) , 315-322
Communicating with Emotional Patients: Thoughts, Skills, and Influencing Factors for Ontario Radiation Therapists
- 10 June 2016
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 15 (4) , 314-321
Dosimetric impacts on skin toxicity for patients using topical agents and dressings during radiotherapy
Background and purpose: Skin care practices for radiotherapy patients are complicated by dosimetric concerns. This study measures the effect on skin dose of various topical agents and dressings.Materials and methods: Superficial doses were measured under 17 topical agents and dressings and three clinical materials for reference. Dose was measured using a MOSFET detector under a 1 mm polymethyl methacrylate slab, with 6 MV photon beams at 100 cm source to surface distance.Results: Relative skin dose under reference materials was 128% (thermoplastic mask), 158% (5 mm bolus) and 171% (10 mm bolus). Under a realistic application of topical agent (0·5 mm), relative skin doses were 106–111%. All dry dressings yielded relative dose of ≤111%; two wet dressings yielded higher relative doses (133 and 141%).Conclusions: Under clinically relevant conditions, no cream, gel or dry dressing increased the skin dose beyond that seen with a thermoplastic mask. Dressings soaked with water produced less skin dose than 5 mm bolus. This may be unacceptable if wet dressings are in place for the majority of the treatment course. Our results suggest that skin care practices should not be limited by dosimetric concerns when using a 6 MV photon beam.
- 10 June 2016
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 15 (4) , 314-321
Dosimetric impacts on skin toxicity for patients using topical agents and dressings during radiotherapy
Background and purpose: Skin care practices for radiotherapy patients are complicated by dosimetric concerns. This study measures the effect on skin dose of various topical agents and dressings.Materials and methods: Superficial doses were measured under 17 topical agents and dressings and three clinical materials for reference. Dose was measured using a MOSFET detector under a 1 mm polymethyl methacrylate slab, with 6 MV photon beams at 100 cm source to surface distance.Results: Relative skin dose under reference materials was 128% (thermoplastic mask), 158% (5 mm bolus) and 171% (10 mm bolus). Under a realistic application of topical agent (0·5 mm), relative skin doses were 106–111%. All dry dressings yielded relative dose of ≤111%; two wet dressings yielded higher relative doses (133 and 141%).Conclusions: Under clinically relevant conditions, no cream, gel or dry dressing increased the skin dose beyond that seen with a thermoplastic mask. Dressings soaked with water produced less skin dose than 5 mm bolus. This may be unacceptable if wet dressings are in place for the majority of the treatment course. Our results suggest that skin care practices should not be limited by dosimetric concerns when using a 6 MV photon beam.
- 1 March 2016
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 47 (1) , 43-48
Development and Implementation of an Electronic Learning Module for Volumetric Image-Guided Radiation Therapy
- 1 March 2016
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 47 (1) , 43-48
Development and Implementation of an Electronic Learning Module for Volumetric Image-Guided Radiation Therapy
- 21 June 2013
- Published by Springer Nature in Journal of Cancer Education
- Vol. 28 (3) , 474-480
Patient and Staff Assessment of an Audiovisual Education Tool for Head and Neck Radiation Therapy
The purpose of this study was to understand and compare patient and staff perceptions of a video-based preparatory education tool for head and neck radiotherapy. Patients and staff completed a questionnaire assessing their perceptions of whether the education tool was relevant, clear, complete and reassuring. Staff rated the video's accuracy and anticipated impact on future patient information needs. Demographic information was collected. Open-ended questions were used to elicit additional feedback. Quantitative responses from 50 patients and 48 staff were very positive and not significantly different between the two groups. Content analysis of the qualitative data provided insight into the information and approaches valued by patients and staff and how these differed. Staff members were more critical of the production quality and completeness of information related to procedures and treatment side effects. Patients valued seeing procedures acted out and desired more information about what these experiences would feel like and how to engage in self-care. Although staff-driven development may be an effective method of designing the content and approach of a preparatory education video, care should be taken to consider differences between patient and staff perceptions of information needs.
- 21 June 2013
- Published by Springer Nature in Journal of Cancer Education
- Vol. 28 (3) , 474-480
Patient and Staff Assessment of an Audiovisual Education Tool for Head and Neck Radiation Therapy
The purpose of this study was to understand and compare patient and staff perceptions of a video-based preparatory education tool for head and neck radiotherapy. Patients and staff completed a questionnaire assessing their perceptions of whether the education tool was relevant, clear, complete and reassuring. Staff rated the video's accuracy and anticipated impact on future patient information needs. Demographic information was collected. Open-ended questions were used to elicit additional feedback. Quantitative responses from 50 patients and 48 staff were very positive and not significantly different between the two groups. Content analysis of the qualitative data provided insight into the information and approaches valued by patients and staff and how these differed. Staff members were more critical of the production quality and completeness of information related to procedures and treatment side effects. Patients valued seeing procedures acted out and desired more information about what these experiences would feel like and how to engage in self-care. Although staff-driven development may be an effective method of designing the content and approach of a preparatory education video, care should be taken to consider differences between patient and staff perceptions of information needs.
- 11 June 2013
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 13 (3) , 294-301
Evaluating the relevance of dosimetric considerations to patient instructions regarding skin care during radiation therapy
Introduction: Patient teaching in radiation therapy may include restrictions on applying skin products owing to concerns that the presence of such materials may increase skin dose. These restrictions may create unnecessarily complicated and conflicting self-care instructions.Purpose: To determine what thickness of skin product is necessary to produce a clinically meaningful dose increase to the skin, and provide recommendations for evidence-based patient instructions.Methods: Dosimetric measurements and Monte Carlo simulations were used to calculate skin dose under 0–1·5 mm thicknesses of two common classes of skin product for a variety of treatment geometries. The thickness of product required to produce a clinically significant dose increase to the skin was determined.Results: The thickness of product required to create a clinically meaningful dose increase was >0·7 mm for 10 × 10 cm2fields and >1·5 mm for 1 × 1 cm2fields. A typical application of product would be only 0·3 mm.Conclusion: It seems unrealistic to anticipate patients using sufficiently large quantities of skin product to be of clinical concern. We therefore recommend that there are no dosimetric reasons to restrict the use of these types of skin products during radiation therapy for common treatment scenarios.
- 11 June 2013
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 13 (3) , 294-301
Evaluating the relevance of dosimetric considerations to patient instructions regarding skin care during radiation therapy
Introduction: Patient teaching in radiation therapy may include restrictions on applying skin products owing to concerns that the presence of such materials may increase skin dose. These restrictions may create unnecessarily complicated and conflicting self-care instructions.Purpose: To determine what thickness of skin product is necessary to produce a clinically meaningful dose increase to the skin, and provide recommendations for evidence-based patient instructions.Methods: Dosimetric measurements and Monte Carlo simulations were used to calculate skin dose under 0–1·5 mm thicknesses of two common classes of skin product for a variety of treatment geometries. The thickness of product required to produce a clinically significant dose increase to the skin was determined.Results: The thickness of product required to create a clinically meaningful dose increase was >0·7 mm for 10 × 10 cm2fields and >1·5 mm for 1 × 1 cm2fields. A typical application of product would be only 0·3 mm.Conclusion: It seems unrealistic to anticipate patients using sufficiently large quantities of skin product to be of clinical concern. We therefore recommend that there are no dosimetric reasons to restrict the use of these types of skin products during radiation therapy for common treatment scenarios.
- 1 December 2012
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 43 (4) , 221-227
Evaluation of the Effects of Pre-Treatment Education on Self-Efficacy and Anxiety in Patients Receiving Radiation Therapy: A Pilot Study
- 1 December 2012
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 43 (4) , 221-227
Evaluation of the Effects of Pre-Treatment Education on Self-Efficacy and Anxiety in Patients Receiving Radiation Therapy: A Pilot Study