Luis Ammour
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Luis Ammour has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Christian Morel
Aix-Marseille Universite
2 shared publications - Jerome Baudot
Institut National de Physique Nucléaire et de Physique des Particules
2 shared publications - Luc Zimmer
Université Claude Bernard Lyon 1, Lyon Neuroscience Research Center, CNRS, INSERM, Lyon, France
2 shared publications - Marc-Antoine Verdier
Univ. Paris-Diderot, Sorbonne Paris Cité, IMNC CNRS-IN2P3, 91405 Orsay, France
2 shared publications P. Pangaud
2 shared publications- Philippe Laniece
IJCLab
2 shared publications
Latest Publications
- 3 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Développement d'une sonde intracérébrale à pixels actifs pour l'imagerie bêta du cerveau du rat libre de ses mouvements
Au cours des 20 dernières années, de nombreux modèles animaux ont émergé, permettant le développement de nouvelles approches pour l'étude préclinique du cerveau sain et pathologique. Les rongeurs sont ainsi devenus des acteurs incontournables des avancées thérapeutiques. Dans ce contexte, l'imagerie radioisotopique, qui permet de quantifier des traceurs radioactifs avec une sensibilité excellente, constitue un outil de choix l'étude des processus cérébraux in vivo. Mais, jusqu'à présent, les techniques de radioimagerie les plus courantes imposent l'anesthésie ou l'immobilisation de l'animal. Or, les anesthésiants affectent les processus biologiques étudiés. De plus, il existe un vif intérêt pour l'étude simultanée du comportement de l'animal. L'acquisition d'une image dynamique des processus cérébraux concomitante à la mesure du comportement de l'animal éveillé et libre de ses mouvements est une information précieuse pour l'étude de l'addiction, de la mémoire, etc.À IMNC, nous avons abordé la neuroimagerie comportementale par une approche originale basée sur des sondes intracérébrales qui mesurent la concentration du traceur radioactif par détection directe des positons in situ. La sonde PIXSIC, basée sur un capteur pixelisé à diodes de silicium, a démontré leur pertinence dans le cadre d'études pharmacologiques chez l'animal totalement libre de ses mouvements. Toutefois, PIXSIC a montré quelques limitations pour son utilisation longitudinale : un niveau de bruit élevé dû aux perturbations électromagnétiques, une forte sensibilité au rayonnement gamma d'annihilation et une grande fragilité mécanique de l'implant aminci à 200 micromètres. En nous appuyant sur l'avènement des technologies CMOS pour la détection des particules chargées en physique des hautes énergies, nous avons pour ambition de concevoir MAPSSIC, une sonde qui réponde aux difficultés mises en avant par PIXSIC. Les capteurs CMOS permettent d'inclure l'amplification au niveau des pixels, limitant ainsi le bruit d'origine électromagnétique. Le volume sensible peut être réduit à une épaisseur de quelques dizaines de micromètres, réduisant ainsi fortement la sensibilité aux gammas et autorisant l'augmentation de son épaisseur totale pour assurer sa robustesse mécanique. Enfin, les capteurs CMOS nous permettent de concevoir un détecteur fortement pixelisé pour accéder à de nouvelles capacités d'imagerie. Cette thèse a eu pour objectif de développer une version optimisé de la sonde. Pour cela, nous avons imaginé un premier prototype de capteur CMOS et nous avons développé un modèle Monte Carlo pour estimer ses propriétés de détection. Nous avons pu démontrer que ses performances le qualifiait pour l'usage prévu. Notamment en terme de sensibilité, de volume d’isoefficacité et d’énergie déposée. Nous avons également pu explorer plusieurs paramètres d’optimisation, les dimensions des pixels et l’épaisseur de la zone sensible, qui nous permettent de considérer MAPSSIC au delà du premier prototype. Fort de ces bases théoriques nous avons conçu plusieurs exemplaires du capteur. Les développements qui ont été établis durant la thèse se sont ensuite focalisés sur un ensemble d'outils méthodologiques, logiciels et matériels afin de permettre la caractérisation physique du capteur à l'aide de sources radioactives. Nous avons pu établir l'uniformité de la réponse des pixels et la plage de taux d’évènements assurant la linéarité du taux de comptage. Ces éléments nous ont permis de conclure sur la pertinence de ce capteur pour la conception d'un dispositif autonome d'imagerie. Celui-ci est constitué d'un implant fait de deux capteurs dos-à-dos, d'un système électronique assurant le contrôle des capteurs, la lecture du signal et la communication sans fil et d'une station d'acquisition. Dans le cadre de la thèse, nous avons montré son adéquation pour l'évaluation des variations de l'activité d'une source radioactive bêta+ liquide dans laquelle l'implant a été plongé.
- 3 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Développement d'une sonde intracérébrale à pixels actifs pour l'imagerie bêta du cerveau du rat libre de ses mouvements
Au cours des 20 dernières années, de nombreux modèles animaux ont émergé, permettant le développement de nouvelles approches pour l'étude préclinique du cerveau sain et pathologique. Les rongeurs sont ainsi devenus des acteurs incontournables des avancées thérapeutiques. Dans ce contexte, l'imagerie radioisotopique, qui permet de quantifier des traceurs radioactifs avec une sensibilité excellente, constitue un outil de choix l'étude des processus cérébraux in vivo. Mais, jusqu'à présent, les techniques de radioimagerie les plus courantes imposent l'anesthésie ou l'immobilisation de l'animal. Or, les anesthésiants affectent les processus biologiques étudiés. De plus, il existe un vif intérêt pour l'étude simultanée du comportement de l'animal. L'acquisition d'une image dynamique des processus cérébraux concomitante à la mesure du comportement de l'animal éveillé et libre de ses mouvements est une information précieuse pour l'étude de l'addiction, de la mémoire, etc.À IMNC, nous avons abordé la neuroimagerie comportementale par une approche originale basée sur des sondes intracérébrales qui mesurent la concentration du traceur radioactif par détection directe des positons in situ. La sonde PIXSIC, basée sur un capteur pixelisé à diodes de silicium, a démontré leur pertinence dans le cadre d'études pharmacologiques chez l'animal totalement libre de ses mouvements. Toutefois, PIXSIC a montré quelques limitations pour son utilisation longitudinale : un niveau de bruit élevé dû aux perturbations électromagnétiques, une forte sensibilité au rayonnement gamma d'annihilation et une grande fragilité mécanique de l'implant aminci à 200 micromètres. En nous appuyant sur l'avènement des technologies CMOS pour la détection des particules chargées en physique des hautes énergies, nous avons pour ambition de concevoir MAPSSIC, une sonde qui réponde aux difficultés mises en avant par PIXSIC. Les capteurs CMOS permettent d'inclure l'amplification au niveau des pixels, limitant ainsi le bruit d'origine électromagnétique. Le volume sensible peut être réduit à une épaisseur de quelques dizaines de micromètres, réduisant ainsi fortement la sensibilité aux gammas et autorisant l'augmentation de son épaisseur totale pour assurer sa robustesse mécanique. Enfin, les capteurs CMOS nous permettent de concevoir un détecteur fortement pixelisé pour accéder à de nouvelles capacités d'imagerie. Cette thèse a eu pour objectif de développer une version optimisé de la sonde. Pour cela, nous avons imaginé un premier prototype de capteur CMOS et nous avons développé un modèle Monte Carlo pour estimer ses propriétés de détection. Nous avons pu démontrer que ses performances le qualifiait pour l'usage prévu. Notamment en terme de sensibilité, de volume d’isoefficacité et d’énergie déposée. Nous avons également pu explorer plusieurs paramètres d’optimisation, les dimensions des pixels et l’épaisseur de la zone sensible, qui nous permettent de considérer MAPSSIC au delà du premier prototype. Fort de ces bases théoriques nous avons conçu plusieurs exemplaires du capteur. Les développements qui ont été établis durant la thèse se sont ensuite focalisés sur un ensemble d'outils méthodologiques, logiciels et matériels afin de permettre la caractérisation physique du capteur à l'aide de sources radioactives. Nous avons pu établir l'uniformité de la réponse des pixels et la plage de taux d’évènements assurant la linéarité du taux de comptage. Ces éléments nous ont permis de conclure sur la pertinence de ce capteur pour la conception d'un dispositif autonome d'imagerie. Celui-ci est constitué d'un implant fait de deux capteurs dos-à-dos, d'un système électronique assurant le contrôle des capteurs, la lecture du signal et la communication sans fil et d'une station d'acquisition. Dans le cadre de la thèse, nous avons montré son adéquation pour l'évaluation des variations de l'activité d'une source radioactive bêta+ liquide dans laquelle l'implant a été plongé.
- 22 May 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1064
Characterization of IMIC, an implantable needle-shaped positron sensitive monolithic active pixel sensor for preclinical molecular neuroimaging
- 22 May 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1064
Characterization of IMIC, an implantable needle-shaped positron sensitive monolithic active pixel sensor for preclinical molecular neuroimaging
- Open Access
- 14 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 3 (3) , 302-314
MAPSSIC, a Novel CMOS Intracerebral Positrons Probe for Deep Brain Imaging in Awake and Freely Moving Rats: A Monte Carlo Study
Preclinical behavior neuroimaging gathers simultaneous assessment of behavior and functional brain imaging. It is a potential key breakthrough to improve the understanding of brain processes and assess the validity of preclinical studies in drug development. Achieving such a combination is difficult, anesthesia or restraints inherent to conventional nuclear imaging preclude its use for behavior studies. In that context, we have proposed an original strategy using submillimetric probes to directly measures positrons inside the rat brain. This paper gives the results of Monte Carlo simulations of a new generation of intracerebral positron probe based on a CMOS Monolithic Active Pixel Sensor. We present the results obtained for a probe into a large homogeneous volume of radioactive water (18F) leading to a sensitivity of 0.88 cps ∙ Bq-1 ∙ mm3 and a mean energy deposition by positrons of 15.1 keV. Simulation in simplified brain-shaped sources modeling a 11c-raclopride experiment shows that the implanted volume modeling the left putamen contribute to 92.4% of the signal from positrons. We also investigate the effects of the thickness of the sensitive layer, the energy threshold and pixel dimensions on the detection capacities of the sensor. We demonstrate that an increase in the sensitive thickness from 18 to 190μ would lead to an increase of positrons sensitivity by a factor of 1.74, but to a decrease of the direct (positrons) to indirect (γ-rays and electrons) sensitivity ratio by a factor of 1.59. Finally we show that for a threshold lower than about 5keV the effect of the pixel dimensions is negligible.
- 14 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 3 (3) , 302-314
Open AccessMAPSSIC, a Novel CMOS Intracerebral Positrons Probe for Deep Brain Imaging in Awake and Freely Moving Rats: A Monte Carlo Study
Preclinical behavior neuroimaging gathers simultaneous assessment of behavior and functional brain imaging. It is a potential key breakthrough to improve the understanding of brain processes and assess the validity of preclinical studies in drug development. Achieving such a combination is difficult, anesthesia or restraints inherent to conventional nuclear imaging preclude its use for behavior studies. In that context, we have proposed an original strategy using submillimetric probes to directly measures positrons inside the rat brain. This paper gives the results of Monte Carlo simulations of a new generation of intracerebral positron probe based on a CMOS Monolithic Active Pixel Sensor. We present the results obtained for a probe into a large homogeneous volume of radioactive water (18F) leading to a sensitivity of 0.88 cps ∙ Bq-1 ∙ mm3 and a mean energy deposition by positrons of 15.1 keV. Simulation in simplified brain-shaped sources modeling a 11c-raclopride experiment shows that the implanted volume modeling the left putamen contribute to 92.4% of the signal from positrons. We also investigate the effects of the thickness of the sensitive layer, the energy threshold and pixel dimensions on the detection capacities of the sensor. We demonstrate that an increase in the sensitive thickness from 18 to 190μ would lead to an increase of positrons sensitivity by a factor of 1.74, but to a decrease of the direct (positrons) to indirect (γ-rays and electrons) sensitivity ratio by a factor of 1.59. Finally we show that for a threshold lower than about 5keV the effect of the pixel dimensions is negligible.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
IMIC — needle-shaped low-power monolithic active pixel sensor for molecular neuroimaging on awake and freely moving rats
IMIC is a Monolithic Active Pixel Sensor prototype for the MAPSSIC project dedicated to direct detection of low energy β+ rays in the brain of awake and freely-moving rats using CMOS technology. Former experiments using a β+ Si probe developed within the PIXSIC project validated a methodological proof of concept. However, conducting routinely such measurements would require improvements with respect to the passive pixel sensors employed in PIXSIC. The new IMIC circuit is fabricated in a 180 nm CMOS Image Sensor Technology and features a matrix of 16 × 128 pixels, which are 30 × 50 μm 2 large. The sensor has a needle-like aspect ratio (610 μm × 12 000 μm). The chip is produced on a 18 μm high-resistivity epitaxial layer substrate. The foreseen application requires high sensitivity to β-rays while being immune to background γ-rays. Another severe constraint is the limited power dissipation in order to minimize the thermal impact on the brain. IMIC is a fully-programmable digital sensor. The pixel design is based on the front-end architecture of the ALPIDE chip. However modifications have been made to store the information inside fired pixels between two readouts allowing low data throughput. The circuit is controlled through the SPI protocol, which allows for setting all the necessary polarization signals. The results of post-layout simulations show a high signal to noise ratio (>40) and low power dissipation of 115 μW/matrix. Laboratory characterization using β-rays validate these predictions and demonstrated that the slow readout can cope with the expected low activity (≈ 120 hits/matrix/s).
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
IMIC — needle-shaped low-power monolithic active pixel sensor for molecular neuroimaging on awake and freely moving rats
IMIC is a Monolithic Active Pixel Sensor prototype for the MAPSSIC project dedicated to direct detection of low energy β+ rays in the brain of awake and freely-moving rats using CMOS technology. Former experiments using a β+ Si probe developed within the PIXSIC project validated a methodological proof of concept. However, conducting routinely such measurements would require improvements with respect to the passive pixel sensors employed in PIXSIC. The new IMIC circuit is fabricated in a 180 nm CMOS Image Sensor Technology and features a matrix of 16 × 128 pixels, which are 30 × 50 μm 2 large. The sensor has a needle-like aspect ratio (610 μm × 12 000 μm). The chip is produced on a 18 μm high-resistivity epitaxial layer substrate. The foreseen application requires high sensitivity to β-rays while being immune to background γ-rays. Another severe constraint is the limited power dissipation in order to minimize the thermal impact on the brain. IMIC is a fully-programmable digital sensor. The pixel design is based on the front-end architecture of the ALPIDE chip. However modifications have been made to store the information inside fired pixels between two readouts allowing low data throughput. The circuit is controlled through the SPI protocol, which allows for setting all the necessary polarization signals. The results of post-layout simulations show a high signal to noise ratio (>40) and low power dissipation of 115 μW/matrix. Laboratory characterization using β-rays validate these predictions and demonstrated that the slow readout can cope with the expected low activity (≈ 120 hits/matrix/s).
- 5 March 2015
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (6) , 2475-2491
Assessment of a fully 3D Monte Carlo reconstruction method for preclinical PET with iodine-124
Iodine-124 is a radionuclide well suited to the labeling of intact monoclonal antibodies. Yet, accurate quantification in preclinical imaging with I-124 is challenging due to the large positron range and a complex decay scheme including high-energy gammas. The aim of this work was to assess the quantitative performance of a fully 3D Monte Carlo (MC) reconstruction for preclinical I-124 PET. The high-resolution small animal PET Inveon (Siemens) was simulated using GATE 6.1. Three system matrices (SM) of different complexity were calculated in addition to a Siddon-based ray tracing approach for comparison purpose. Each system matrix accounted for a more or less complete description of the physics processes both in the scanned object and in the PET scanner. One homogeneous water phantom and three heterogeneous phantoms including water, lungs and bones were simulated, where hot and cold regions were used to assess activity recovery as well as the trade-off between contrast recovery and noise in different regions. The benefit of accounting for scatter, attenuation, positron range and spurious coincidences occurring in the object when calculating the system matrix used to reconstruct I-124 PET images was highlighted. We found that the use of an MC SM including a thorough modelling of the detector response and physical effects in a uniform water-equivalent phantom was efficient to get reasonable quantitative accuracy in homogeneous and heterogeneous phantoms. Modelling the phantom heterogeneities in the SM did not necessarily yield the most accurate estimate of the activity distribution, due to the high variance affecting many SM elements in the most sophisticated SM.
- 5 March 2015
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (6) , 2475-2491
Assessment of a fully 3D Monte Carlo reconstruction method for preclinical PET with iodine-124
Iodine-124 is a radionuclide well suited to the labeling of intact monoclonal antibodies. Yet, accurate quantification in preclinical imaging with I-124 is challenging due to the large positron range and a complex decay scheme including high-energy gammas. The aim of this work was to assess the quantitative performance of a fully 3D Monte Carlo (MC) reconstruction for preclinical I-124 PET. The high-resolution small animal PET Inveon (Siemens) was simulated using GATE 6.1. Three system matrices (SM) of different complexity were calculated in addition to a Siddon-based ray tracing approach for comparison purpose. Each system matrix accounted for a more or less complete description of the physics processes both in the scanned object and in the PET scanner. One homogeneous water phantom and three heterogeneous phantoms including water, lungs and bones were simulated, where hot and cold regions were used to assess activity recovery as well as the trade-off between contrast recovery and noise in different regions. The benefit of accounting for scatter, attenuation, positron range and spurious coincidences occurring in the object when calculating the system matrix used to reconstruct I-124 PET images was highlighted. We found that the use of an MC SM including a thorough modelling of the detector response and physical effects in a uniform water-equivalent phantom was efficient to get reasonable quantitative accuracy in homogeneous and heterogeneous phantoms. Modelling the phantom heterogeneities in the SM did not necessarily yield the most accurate estimate of the activity distribution, due to the high variance affecting many SM elements in the most sophisticated SM.