Raoul François
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Raoul François has a total of 136 co-authors. Here are the top co-authors by number of shared publications:
- Arnaud Castel
School of Civil and Environmental Engineering, University of Technology Sydney (UTS), Sydney, NSW 2007, Australia
42 shared publications - Firas Al-Mahmoud
CNRS, IJL, Université de Lorraine, 54000 Nancy, France
12 shared publications G. Arliguie
11 shared publications- Wenjun Zhu
Shanghai Key Laboratory of Rail Infrastructure Durability and System Safety, College of Transportation Tongji University Shanghai Shanghai China
10 shared publications - Vu Hiep Dang
Hanoi Architectural University
8 shared publications Dario Coronelli
6 shared publications
Latest Publications
- Open Access
- 29 May 2026
- Published by Wiley in Materials and Corrosion
- Vol. 77 (9) , 1483-1499
Fracture of the Passive Film on Reinforcing Steel in Concrete Under Mechanical Loading
This study investigates the fracture of the passive film on reinforcing steel when steel elongation exceeds a threshold value, in the absence of aggressive species such as chlorides or carbon dioxide. Reinforced concrete specimens are subjected to three‐point bending to generate a load‐induced crack. Steel coupons embedded in the concrete are electrically connected to the reinforcing steel to measure the macro cell corrosion current when an anodic site forms. Once the critical load for concrete cracking is exceeded, a macro cell corrosion current is recorded as soon as the load increases, indicating rupture of the passive film and, consequently, anodic activity at the crack location, associated with the formation of a new passive film that heals the passive film fracture. The elongation threshold is close to 950 microstrain (or 190 MPa). As soon as the load stops increasing, the corrosion current sharply decreases, suggesting rapid repair of the passive film. After this repair, small variations in the tensile stress of the reinforcement lead to measurable corrosion currents, indicating that the repaired zone may constitute a weak point in the passive film.
- 29 May 2026
- Published by Wiley in Materials and Corrosion
- Vol. 77 (9) , 1483-1499
Open AccessFracture of the Passive Film on Reinforcing Steel in Concrete Under Mechanical Loading
This study investigates the fracture of the passive film on reinforcing steel when steel elongation exceeds a threshold value, in the absence of aggressive species such as chlorides or carbon dioxide. Reinforced concrete specimens are subjected to three‐point bending to generate a load‐induced crack. Steel coupons embedded in the concrete are electrically connected to the reinforcing steel to measure the macro cell corrosion current when an anodic site forms. Once the critical load for concrete cracking is exceeded, a macro cell corrosion current is recorded as soon as the load increases, indicating rupture of the passive film and, consequently, anodic activity at the crack location, associated with the formation of a new passive film that heals the passive film fracture. The elongation threshold is close to 950 microstrain (or 190 MPa). As soon as the load stops increasing, the corrosion current sharply decreases, suggesting rapid repair of the passive film. After this repair, small variations in the tensile stress of the reinforcement lead to measurable corrosion currents, indicating that the repaired zone may constitute a weak point in the passive film.
- 15 May 2026
- Published by Elsevier in Construction and Building Materials
- Vol. 531
Corrosion in the bending zone of transversal stirrups in the RC beams exposed to a chloride environment
- 15 May 2026
- Published by Elsevier in Construction and Building Materials
- Vol. 531
Corrosion in the bending zone of transversal stirrups in the RC beams exposed to a chloride environment
- Open Access
- 30 September 2022
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 364, 02025
A comparison between uniform and galvanic corrosion rate in carbonation induced corrosion of reinforced concrete
Carbonation-induced corrosion is usually considered in uniform or generalized corrosion. This is true for small laboratory samples but not necessary the case for real reinforced concrete structures built with multilayers reinforcement. Multi-layers reinforcement could lead to a galvanic corrosion between first de-passivated layer closed to the concrete surface and deeper layers still passivated. The present paper compares the uniform corrosion density and the galvanic corrosion density for concrete samples made with two different type of cements. CEM III cement despite their higher susceptibility to carbonation show a significant lower galvanic corrosion density, which would lead to a significant increase in the service life of RC structures, exposed to carbonation.
- 30 September 2022
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 364, 02025
Open AccessA comparison between uniform and galvanic corrosion rate in carbonation induced corrosion of reinforced concrete
Carbonation-induced corrosion is usually considered in uniform or generalized corrosion. This is true for small laboratory samples but not necessary the case for real reinforced concrete structures built with multilayers reinforcement. Multi-layers reinforcement could lead to a galvanic corrosion between first de-passivated layer closed to the concrete surface and deeper layers still passivated. The present paper compares the uniform corrosion density and the galvanic corrosion density for concrete samples made with two different type of cements. CEM III cement despite their higher susceptibility to carbonation show a significant lower galvanic corrosion density, which would lead to a significant increase in the service life of RC structures, exposed to carbonation.
- Open Access
- 3 May 2022
- Published by Springer Nature in Materials and Structures
- Vol. 55 (4) , 1-29
Methods for characterising the steel–concrete interface to enhance understanding of reinforcement corrosion: a critical review by RILEM TC 262-SCI
The steel–concrete interface (SCI) is a complex, multi-phase and multi-scale system. It is widely known to influence the performance and long-term durability of concrete structures. However, a fundamental understanding of its properties and effects on corrosion initiation of embedded reinforcing steel remains elusive. This is attributed to its complicated heterogeneity and time-dependent nature, exacerbated by the lack of suitable techniques for systematic and detailed characterisation. This paper, prepared by members of the RILEM Technical Committee 262-SCI, critically reviews available information regarding current methods (laboratory or field-based) for characterising local properties of the SCI that have been identified as governing factors affecting corrosion initiation. These properties include characteristics of the steel such as mill scale and rust layers, and characteristics of the concrete such as interfacial voids, microstructure and moisture content. We evaluated over twenty methods and summarised their advantages, applications and limitations. The findings show a severe lack of well established, non-destructive techniques that are suitable for direct monitoring of the SCI at a representative scale with sufficiently high resolution (spatial, temporal), particularly for moisture related aspects. Several promising novel techniques with significant potential for further development and application were identified and discussed. Finally, we provide several recommendations for future research needs that are required to advance this critically important topic.
- 3 May 2022
- Published by Springer Nature in Materials and Structures
- Vol. 55 (4) , 1-29
Open AccessMethods for characterising the steel–concrete interface to enhance understanding of reinforcement corrosion: a critical review by RILEM TC 262-SCI
The steel–concrete interface (SCI) is a complex, multi-phase and multi-scale system. It is widely known to influence the performance and long-term durability of concrete structures. However, a fundamental understanding of its properties and effects on corrosion initiation of embedded reinforcing steel remains elusive. This is attributed to its complicated heterogeneity and time-dependent nature, exacerbated by the lack of suitable techniques for systematic and detailed characterisation. This paper, prepared by members of the RILEM Technical Committee 262-SCI, critically reviews available information regarding current methods (laboratory or field-based) for characterising local properties of the SCI that have been identified as governing factors affecting corrosion initiation. These properties include characteristics of the steel such as mill scale and rust layers, and characteristics of the concrete such as interfacial voids, microstructure and moisture content. We evaluated over twenty methods and summarised their advantages, applications and limitations. The findings show a severe lack of well established, non-destructive techniques that are suitable for direct monitoring of the SCI at a representative scale with sufficiently high resolution (spatial, temporal), particularly for moisture related aspects. Several promising novel techniques with significant potential for further development and application were identified and discussed. Finally, we provide several recommendations for future research needs that are required to advance this critically important topic.
- 1 December 2018
- Published by Elsevier in Construction and Building Materials
- Vol. 193, 97-104
Relation between crack opening and extent of the damage induced at the steel/mortar interface
- 1 December 2018
- Published by Elsevier in Construction and Building Materials
- Vol. 193, 97-104
Relation between crack opening and extent of the damage induced at the steel/mortar interface
- Open Access
- 31 October 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 199, 04003
A new approach to determine the chloride threshold initiating corrosion: Preliminary results
The initiation of corrosion by chlorides is traditionally based on the existence of a threshold that would lead to corrosion. Almost all existing approaches considered implicitly that corrosion induced by chlorides is uniform and take not into account the intrinsic localized character of corrosion in reinforced concrete structures. This work aims to implement a new test protocol that takes explicitly into account the localized nature of chlorides-induced corrosion by inducing physical separation between anode and cathode thus permitting to measure the corrosion current. The anodic part allows to test different levels of chlorides and the cathodic part to highlight the ohmic (limiting ionic current by low porosity) and cathodic (restricting access to oxygen due to saturation of porosity, low porosity, dioxygen consumption by additions) control of corrosion. The chloride threshold is set on the basis of a threshold corrosion current that is considered acceptable with respect to the structure’s life. The first results provide a preliminary idea of the variation of corrosion rate in function of chlorides content. This method also highlights the influence of surface condition of the steel-concrete interface on the corrosion current.
- 31 October 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 199, 04003
Open AccessA new approach to determine the chloride threshold initiating corrosion: Preliminary results
The initiation of corrosion by chlorides is traditionally based on the existence of a threshold that would lead to corrosion. Almost all existing approaches considered implicitly that corrosion induced by chlorides is uniform and take not into account the intrinsic localized character of corrosion in reinforced concrete structures. This work aims to implement a new test protocol that takes explicitly into account the localized nature of chlorides-induced corrosion by inducing physical separation between anode and cathode thus permitting to measure the corrosion current. The anodic part allows to test different levels of chlorides and the cathodic part to highlight the ohmic (limiting ionic current by low porosity) and cathodic (restricting access to oxygen due to saturation of porosity, low porosity, dioxygen consumption by additions) control of corrosion. The chloride threshold is set on the basis of a threshold corrosion current that is considered acceptable with respect to the structure’s life. The first results provide a preliminary idea of the variation of corrosion rate in function of chlorides content. This method also highlights the influence of surface condition of the steel-concrete interface on the corrosion current.
- 17 August 2018
- Published by EDP Sciences in Matériaux & Techniques
- Vol. 106 (2) , 201
Protection cathodique appliquée au béton armé aérien : étude expérimentale et modélisation
Cet article présente une étude expérimentale et numérique de la protection cathodique par courant imposé appliquée sur un mur en béton armé soumis à une corrosion localisée (par macro-piles), typique du béton armé. L’étude numérique est réalisée avec le logiciel COMSOL Multiphysics. L’étude expérimentale et l’étude numérique basée sur les lois physiques de base qui régissent les phénomènes électrochimiques confirment que la polarisation des systèmes de corrosion de type macro-piles est hétérogène et ne peut être appréhendée qu’en trois dimensions. L’uniformité du champ de potentiel à l’interface acier-béton n’est physiquement pas réalisable en appliquant un courant de protection de la surface du béton. Le principe général de la protection cathodique n’a pas à être discuté, mais une attention particulière doit être accordée à la réponse non uniforme des systèmes de corrosion par macro-piles car il remet en question, entre autres, le choix de la position des témoins où la performance du système de PC est évaluée et l’utilisation de critères exprimés en potentiels.
- 17 August 2018
- Published by EDP Sciences in Matériaux & Techniques
- Vol. 106 (2) , 201
Protection cathodique appliquée au béton armé aérien : étude expérimentale et modélisation
Cet article présente une étude expérimentale et numérique de la protection cathodique par courant imposé appliquée sur un mur en béton armé soumis à une corrosion localisée (par macro-piles), typique du béton armé. L’étude numérique est réalisée avec le logiciel COMSOL Multiphysics. L’étude expérimentale et l’étude numérique basée sur les lois physiques de base qui régissent les phénomènes électrochimiques confirment que la polarisation des systèmes de corrosion de type macro-piles est hétérogène et ne peut être appréhendée qu’en trois dimensions. L’uniformité du champ de potentiel à l’interface acier-béton n’est physiquement pas réalisable en appliquant un courant de protection de la surface du béton. Le principe général de la protection cathodique n’a pas à être discuté, mais une attention particulière doit être accordée à la réponse non uniforme des systèmes de corrosion par macro-piles car il remet en question, entre autres, le choix de la position des témoins où la performance du système de PC est évaluée et l’utilisation de critères exprimés en potentiels.
- Open Access
- 5 December 2017
- Published by Rilem Publications SARL in RILEM Technical Letters
- Vol. 2, 27-32
Cathodic protection in reinforced concrete structures affected by macrocell corrosion: a discussion about the significance of the protection criteria
Cathodic protection is a technique that has been used to control corrosion and increase the service life of reinforced concrete structure. Standards as EN ISO 12696 give protection criteria for both impressed current and sacrificial anodes techniques, based on potential value or decay during a depolarization sequence. The polarization (current ON) and depolarization (current OFF) is experimentally studied on a corroded concrete wall thanks to six references electrodes and compared to a time-dependent modelling using FEM software COMSOL Multiphysics. Both experimental and numerical results show significant differences in the time response according to electrode location. This conclusion indicates that the concept of protection criteria defined by the standards is not suitable to assess the efficiency of cathodic protection applied to reinforced concrete structure.
- 5 December 2017
- Published by Rilem Publications SARL in RILEM Technical Letters
- Vol. 2, 27-32
Open AccessCathodic protection in reinforced concrete structures affected by macrocell corrosion: a discussion about the significance of the protection criteria
Cathodic protection is a technique that has been used to control corrosion and increase the service life of reinforced concrete structure. Standards as EN ISO 12696 give protection criteria for both impressed current and sacrificial anodes techniques, based on potential value or decay during a depolarization sequence. The polarization (current ON) and depolarization (current OFF) is experimentally studied on a corroded concrete wall thanks to six references electrodes and compared to a time-dependent modelling using FEM software COMSOL Multiphysics. Both experimental and numerical results show significant differences in the time response according to electrode location. This conclusion indicates that the concept of protection criteria defined by the standards is not suitable to assess the efficiency of cathodic protection applied to reinforced concrete structure.
- 1 September 2017
- Published by Elsevier in Construction and Building Materials
- Vol. 148, 297-306
Influences of corrosion degree and corrosion morphology on the ductility of steel reinforcement
- 1 September 2017
- Published by Elsevier in Construction and Building Materials
- Vol. 148, 297-306
Influences of corrosion degree and corrosion morphology on the ductility of steel reinforcement