Firas Al-Mahmoud
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Firas Al-Mahmoud has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Raoul François
LMDC, Université de Toulouse, INSA, UPS, Toulouse, France
12 shared publications - Arnaud Castel
School of Civil and Environmental Engineering, University of Technology Sydney (UTS), Sydney, NSW 2007, Australia
9 shared publications Christian Tourneur
4 shared publications- Belal Almassri
Faculty of Engineering Department of Civil Engineering Palestine Polytechnic University Hebron Palestine
3 shared publications Abdelouahab Khelil
2 shared publicationsAmjad Kreit
2 shared publications
Latest Publications
- Open Access
- 13 July 2026
- Published by MDPI AG in Infrastructures
- Vol. 11 (7) , 236
Wind-Induced Response of Coupled Shear Wall Systems Based on Wind Tunnel Testing
Coupled shear wall systems are widely used in tall buildings due to their high lateral stiffness and effectiveness in controlling wind-induced serviceability responses. Reliable assessment of their behavior under realistic wind loading requires accurate load representation and properly calibrated numerical modeling. This study investigates the performance of coupled shear wall systems under wind loads derived from wind tunnel testing, where surface pressure time histories were extracted from the TPU Aerodynamic Database and used to generate equivalent full-scale, time-varying wind loads. The preliminary design of a 20-story building was established in ETABS based on current design codes. Detailed nonlinear time-history analyses were subsequently performed in OpenSees to assess the performance under three different wind hazards for the original and refined design, where shear walls were modeled using the Multiple-Vertical-Line-Element Model (MVLEM). Several wind demand indicators, including drift ratios, floor accelerations, and component and cladding performance were evaluated. The results demonstrate that the performance-based design framework enables the identification of critical vulnerabilities that may not be fully captured by conventional code-based drift and strength checks, particularly regarding localized damage accumulation and serviceability-related demands. Additionally, the refined configuration, while requiring only a 4.33% increase in total baseline concrete volume, effectively reduced peak roof drift by 60%, allowing reliable control of dynamic behavior and prevention of structural yielding, as well as ensuring the maintenance of both structural integrity and operational serviceability for the investigated high-rise configuration during severe wind events. Nevertheless, the findings are limited to the investigated building configuration and aerodynamic conditions considered in this study.
- 13 July 2026
- Published by MDPI AG in Infrastructures
- Vol. 11 (7) , 236
Open AccessWind-Induced Response of Coupled Shear Wall Systems Based on Wind Tunnel Testing
Coupled shear wall systems are widely used in tall buildings due to their high lateral stiffness and effectiveness in controlling wind-induced serviceability responses. Reliable assessment of their behavior under realistic wind loading requires accurate load representation and properly calibrated numerical modeling. This study investigates the performance of coupled shear wall systems under wind loads derived from wind tunnel testing, where surface pressure time histories were extracted from the TPU Aerodynamic Database and used to generate equivalent full-scale, time-varying wind loads. The preliminary design of a 20-story building was established in ETABS based on current design codes. Detailed nonlinear time-history analyses were subsequently performed in OpenSees to assess the performance under three different wind hazards for the original and refined design, where shear walls were modeled using the Multiple-Vertical-Line-Element Model (MVLEM). Several wind demand indicators, including drift ratios, floor accelerations, and component and cladding performance were evaluated. The results demonstrate that the performance-based design framework enables the identification of critical vulnerabilities that may not be fully captured by conventional code-based drift and strength checks, particularly regarding localized damage accumulation and serviceability-related demands. Additionally, the refined configuration, while requiring only a 4.33% increase in total baseline concrete volume, effectively reduced peak roof drift by 60%, allowing reliable control of dynamic behavior and prevention of structural yielding, as well as ensuring the maintenance of both structural integrity and operational serviceability for the investigated high-rise configuration during severe wind events. Nevertheless, the findings are limited to the investigated building configuration and aerodynamic conditions considered in this study.
- 1 February 2026
- Published by Springer Nature in ENGINEERING Structure and Civil Engineering
- Vol. 20 (2) , 440-460
Next-generation sustainable voided slabs with steel sheets and spiral plastic fiber reinforcement: Experimental and analytical investigation
- 1 February 2026
- Published by Springer Nature in ENGINEERING Structure and Civil Engineering
- Vol. 20 (2) , 440-460
Next-generation sustainable voided slabs with steel sheets and spiral plastic fiber reinforcement: Experimental and analytical investigation
- Open Access
- 1 December 2025
- Published by MDPI AG in Infrastructures
- Vol. 10 (12) , 326
Multiple Regression and Neural Network-Based Models for the Prediction of the Ultimate Strength of CFRP-Confined Columns
Carbon Fiber-Reinforced Polymers (CFRPs) are gaining popularity as a reliable strengthening technique for reinforced concrete (RC) columns. Several efficient models were developed to predict the stress–strain (σ-ε) curve of CFRP-confined concrete based on experiment findings. The ultimate strength is a crucial parameter for accurate (σ-ε) behavior prediction, since it constitutes an initial step in estimating the corresponding axial strain, as it provides a direct indication of the desired increase in strength. Literature analytical models often produce inconsistent results due to errors in estimating the confinement pressure or effectively confined area or the lack of a strong and stable correlation between ultimate strength and confinement parameters. This study looked at a large collection of experimental results from existing research. It used a statistical method (Pearson’s coefficient) to see how well ultimate strength correlated with various confinement factors. For normal-strength concrete columns with circular sections, there was a strong linear correlation between ultimate strength and the thickness of the CFRP jacket. This correlation weakened for high-strength concrete (HSC) and for rectangular columns. A sensitivity analysis was performed to identify the most influential confinement parameters, showing that the number of CFRP layers (n t) is the most dominant factor, particularly with normal-strength concrete (NSC) in circular columns, accounting for the vast majority of the variance in ultimate strength. Using multiple linear regression equations to predict ultimate strength was also explored; this method demonstrated the best performance with HSC in circular sections, but the results were less promising with NSC. Artificial Neural Networks (ANNs) were developed and trained on the built database, and four statistical metrics were computed for evaluation (R2, RMSE, MAE, MRAE), proving highly accurate and superior to linear regression equations, with mean relative absolute errors MRAEs between 2.4–7.2% for ultimate strength prediction, opening new avenues for optimizing CFRP-strengthened element designs.- 1 December 2025
- Published by MDPI AG in Infrastructures
- Vol. 10 (12) , 326
Open AccessMultiple Regression and Neural Network-Based Models for the Prediction of the Ultimate Strength of CFRP-Confined Columns
Carbon Fiber-Reinforced Polymers (CFRPs) are gaining popularity as a reliable strengthening technique for reinforced concrete (RC) columns. Several efficient models were developed to predict the stress–strain (σ-ε) curve of CFRP-confined concrete based on experiment findings. The ultimate strength is a crucial parameter for accurate (σ-ε) behavior prediction, since it constitutes an initial step in estimating the corresponding axial strain, as it provides a direct indication of the desired increase in strength. Literature analytical models often produce inconsistent results due to errors in estimating the confinement pressure or effectively confined area or the lack of a strong and stable correlation between ultimate strength and confinement parameters. This study looked at a large collection of experimental results from existing research. It used a statistical method (Pearson’s coefficient) to see how well ultimate strength correlated with various confinement factors. For normal-strength concrete columns with circular sections, there was a strong linear correlation between ultimate strength and the thickness of the CFRP jacket. This correlation weakened for high-strength concrete (HSC) and for rectangular columns. A sensitivity analysis was performed to identify the most influential confinement parameters, showing that the number of CFRP layers (n t) is the most dominant factor, particularly with normal-strength concrete (NSC) in circular columns, accounting for the vast majority of the variance in ultimate strength. Using multiple linear regression equations to predict ultimate strength was also explored; this method demonstrated the best performance with HSC in circular sections, but the results were less promising with NSC. Artificial Neural Networks (ANNs) were developed and trained on the built database, and four statistical metrics were computed for evaluation (R2, RMSE, MAE, MRAE), proving highly accurate and superior to linear regression equations, with mean relative absolute errors MRAEs between 2.4–7.2% for ultimate strength prediction, opening new avenues for optimizing CFRP-strengthened element designs. - Open Access
- 21 December 2023
- Published by University of Duhok in The Journal of Duhok University
- Vol. 26 (2) , 57-64
An Analytical Study of The Dynamic Responses of Rc Elevated Water Tanks in Syria under The Effect of The February 2023 Earthquake
The hydrodynamic behavior of RC elevated water tanks is quite complex, and understanding the hydrodynamic behavior effect of the soil structure interaction is necessary for predicting the dynamic response of the elevated tank. In Syria, all RC elevated water tanks were designed to withstand seismic loads that arehigher than the 6th of February earthquake, in which many elevated water tanks had collapsed. In the current study, the reasons behind these collapses will be investigated, and solutions will be proposed. The present work will discuss a case study, which is the most common RC elevated water tank model used in Syria, with the most number of collapses through the last earthquake. This case study represents a cylindrical tank with 200 m3 capacity, elevated on six columns with a length of 15 [m], and a cross section of 50x80 [cm2], this model was design 50 years ago using the classical method where the hydrodynamic effect of the water was not taken into account. In the present study, a numerical simulation will be obtained for this tank, while the hydrodynamic effect of the water will be taken into account using the equations of American standards ACI 350.3-6, while the time history method, where the Turkey-Syria seismic record was adopted. Two strengthening methods ware suggested, the first one using bonding slabs, and the other one using bonding beams.The shear force, overturning moment and the maximum displacement were obtained and compared with those calculated from the strengthened models. It was noticed that strengthening methods decreased the shear force, overturning moment, and the maximum displacement.
- 21 December 2023
- Published by University of Duhok in The Journal of Duhok University
- Vol. 26 (2) , 57-64
Open AccessAn Analytical Study of The Dynamic Responses of Rc Elevated Water Tanks in Syria under The Effect of The February 2023 Earthquake
The hydrodynamic behavior of RC elevated water tanks is quite complex, and understanding the hydrodynamic behavior effect of the soil structure interaction is necessary for predicting the dynamic response of the elevated tank. In Syria, all RC elevated water tanks were designed to withstand seismic loads that arehigher than the 6th of February earthquake, in which many elevated water tanks had collapsed. In the current study, the reasons behind these collapses will be investigated, and solutions will be proposed. The present work will discuss a case study, which is the most common RC elevated water tank model used in Syria, with the most number of collapses through the last earthquake. This case study represents a cylindrical tank with 200 m3 capacity, elevated on six columns with a length of 15 [m], and a cross section of 50x80 [cm2], this model was design 50 years ago using the classical method where the hydrodynamic effect of the water was not taken into account. In the present study, a numerical simulation will be obtained for this tank, while the hydrodynamic effect of the water will be taken into account using the equations of American standards ACI 350.3-6, while the time history method, where the Turkey-Syria seismic record was adopted. Two strengthening methods ware suggested, the first one using bonding slabs, and the other one using bonding beams.The shear force, overturning moment and the maximum displacement were obtained and compared with those calculated from the strengthened models. It was noticed that strengthening methods decreased the shear force, overturning moment, and the maximum displacement.
- 14 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 7 (11) , 1-4
Wireless Strain and Temperature Monitoring in Reinforced Concrete Using Surface Acoustic Wave Sensors
Monitoring the health of civil engineering structures using implanted deformation, temperature and corrosion sensors would further improve maintenance and extend the service life of those structures. However, sensor integration poses a number of problems, due to the presence of cables and on-board electronics. Passive, wireless SAW sensors offer a very promising solution, here. We used commercial SAW devices mounted on steel rebars to carry out an initial feasibility study. Without cables or embedded electronics, we were able to measure the deformation of a concrete beam subjected to bending load. We were also able to measure the temperature continuously over a three-week period.
- 14 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 7 (11) , 1-4
Wireless Strain and Temperature Monitoring in Reinforced Concrete Using Surface Acoustic Wave Sensors
Monitoring the health of civil engineering structures using implanted deformation, temperature and corrosion sensors would further improve maintenance and extend the service life of those structures. However, sensor integration poses a number of problems, due to the presence of cables and on-board electronics. Passive, wireless SAW sensors offer a very promising solution, here. We used commercial SAW devices mounted on steel rebars to carry out an initial feasibility study. Without cables or embedded electronics, we were able to measure the deformation of a concrete beam subjected to bending load. We were also able to measure the temperature continuously over a three-week period.
- 1 May 2023
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 149 (5)
Development of a New Composite Connector for Timber–Concrete Composite Connections
- 1 May 2023
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 149 (5)
Development of a New Composite Connector for Timber–Concrete Composite Connections
- 1 February 2020
- Published by Elsevier in Composite Structures
- Vol. 234
Experimental study on strengthening of RC beams with Side Near Surface Mounted technique-CFRP bars
- 1 February 2020
- Published by Elsevier in Composite Structures
- Vol. 234
Experimental study on strengthening of RC beams with Side Near Surface Mounted technique-CFRP bars
- 1 May 2016
- Published by Elsevier in Composites Part B: Engineering
- Vol. 92, 477-488
Behaviour of corroded reinforced concrete beams repaired with NSM CFRP rods, experimental and finite element study
- 1 May 2016
- Published by Elsevier in Composites Part B: Engineering
- Vol. 92, 477-488
Behaviour of corroded reinforced concrete beams repaired with NSM CFRP rods, experimental and finite element study