Zühal Alpaslan Kösemen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zühal Alpaslan Kösemen has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Şenel Yaran
National Metrology Institute of Türkiye
3 shared publications - Armin Sperling
PTB Bundesallee 100 38116 Braunschweig Germany
2 shared publications - Udo Krüger
TechnoTeam Bildverarbeitung GmbH Ilmenau Germany
2 shared publications - Çağri Kaan Akkan
Leibnitz Institut für Neue Materialien, Saarbrücken
2 shared publications A Sperling
Physikalisch-Technische Bundesanstalt, Braunschweig and Berlin, Germany
1 shared publication- Arif Kösemen
Department of Physics, Mus Alparslan University, 49250 Mus, Turkey
1 shared publication
Latest Publications
- Open Access
- 1 June 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (11) , 115325
Replacing the incandescent lamp-based standards: tuneable broadband UV LED source
A tuneable broadband ultraviolet (UV) LED source covering the spectral range from 255 nm to 405 nm has been designed, developed, and characterized as a potential alternative to conventional incandescent lamp-based transfer standards. The system integrates 79 commercially available UV LEDs arranged into 14 wavelength channels spanning the UVA, UVB, and UVC regions, providing continuous spectral coverage with spectral irradiance levels exceeding 1 mW·m −2 ·nm −1 at all wavelengths. The source incorporates a multi-channel current driver and an active temperature control unit to ensure stable electrical and thermal operating conditions. Comprehensive aging and characterization measurements were carried out over approximately 110 h using an array spectrometer at a distance of 50 cm. The long-term drift was found to be on the order of 10 −4 h −1 after stabilization, indicating stable long-term operation. Instability and reproducibility were evaluated after a warm-up period of 30 min. The instability remained below 0.6% for the majority of the 255 nm—405 nm range, with a maximum peak of 1.2% observed near 285 nm, while reproducibility is maintained below 1.8% for most wavelengths. These results demonstrate that the developed tuneable broadband UV LED source provides sufficient stability, flexibility, and irradiance levels for laboratory irradiance measurements and UV metrology applications.
- 1 June 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (11) , 115325
Open AccessReplacing the incandescent lamp-based standards: tuneable broadband UV LED source
A tuneable broadband ultraviolet (UV) LED source covering the spectral range from 255 nm to 405 nm has been designed, developed, and characterized as a potential alternative to conventional incandescent lamp-based transfer standards. The system integrates 79 commercially available UV LEDs arranged into 14 wavelength channels spanning the UVA, UVB, and UVC regions, providing continuous spectral coverage with spectral irradiance levels exceeding 1 mW·m −2 ·nm −1 at all wavelengths. The source incorporates a multi-channel current driver and an active temperature control unit to ensure stable electrical and thermal operating conditions. Comprehensive aging and characterization measurements were carried out over approximately 110 h using an array spectrometer at a distance of 50 cm. The long-term drift was found to be on the order of 10 −4 h −1 after stabilization, indicating stable long-term operation. Instability and reproducibility were evaluated after a warm-up period of 30 min. The instability remained below 0.6% for the majority of the 255 nm—405 nm range, with a maximum peak of 1.2% observed near 285 nm, while reproducibility is maintained below 1.8% for most wavelengths. These results demonstrate that the developed tuneable broadband UV LED source provides sufficient stability, flexibility, and irradiance levels for laboratory irradiance measurements and UV metrology applications.
- Open Access
- 5 October 2025
- Published by SAGE Publications in Lighting Research & Technology
Assessment of measurement uncertainties for imaging luminance measurements
This paper presents an approach to assess the measurement uncertainty of luminance measurements obtained by imaging luminance measurement devices (ILMDs). A common strategy for users doing measurements in photometry is to characterise and correct for residual errors, that in this domain are often significant. To apply this strategy to measurements with ILMDs leads to issues because the user only has limited knowledge on the device internals and the effort for such characterisations would exceed the capabilities of most users. To illustrate this, the complexity of the devices’ internal operation is shown, and tasks of the manufacturer to build and adjust an ILMD based on a camera system are outlined. From this we concluded, that for most users, the best approach is to assume that all significant effects have been corrected for by the manufacturer, and only the remaining uncertainties need to be estimated. An example is given for this estimation and for the handling of correlations between measurements.
- 5 October 2025
- Published by SAGE Publications in Lighting Research & Technology
Open AccessAssessment of measurement uncertainties for imaging luminance measurements
This paper presents an approach to assess the measurement uncertainty of luminance measurements obtained by imaging luminance measurement devices (ILMDs). A common strategy for users doing measurements in photometry is to characterise and correct for residual errors, that in this domain are often significant. To apply this strategy to measurements with ILMDs leads to issues because the user only has limited knowledge on the device internals and the effort for such characterisations would exceed the capabilities of most users. To illustrate this, the complexity of the devices’ internal operation is shown, and tasks of the manufacturer to build and adjust an ILMD based on a camera system are outlined. From this we concluded, that for most users, the best approach is to assume that all significant effects have been corrected for by the manufacturer, and only the remaining uncertainties need to be estimated. An example is given for this estimation and for the handling of correlations between measurements.
- Open Access
- 24 May 2024
- Published by EDP Sciences in Journal of the European Optical Society-Rapid Publications
- Vol. 20 (1) , 21
Uncertainty analysis of spectral flux measurement using Monte Carlo simulation
In photometry, spectrally integrated quantities are commonly used, and their uncertainties are calculated using classical approaches. Since determining correlations at different wavelengths and effects on spectrally integrated quantities is rather complex, a noise modification of the spectral value using Monte Carlo simulation was applied to estimate unknown correlations in the uncertainty of total luminous flux based on integrated spectral luminous flux values. For this aim, an LED with 6500 K correlated colour temperature was measured in an integrated sphere flux measurement system. The correlations between the measurements at different wavelengths were analysed, and the uncertainty boundaries of the integrated quantity and total luminous flux were obtained.
- 24 May 2024
- Published by EDP Sciences in Journal of the European Optical Society-Rapid Publications
- Vol. 20 (1) , 21
Open AccessUncertainty analysis of spectral flux measurement using Monte Carlo simulation
In photometry, spectrally integrated quantities are commonly used, and their uncertainties are calculated using classical approaches. Since determining correlations at different wavelengths and effects on spectrally integrated quantities is rather complex, a noise modification of the spectral value using Monte Carlo simulation was applied to estimate unknown correlations in the uncertainty of total luminous flux based on integrated spectral luminous flux values. For this aim, an LED with 6500 K correlated colour temperature was measured in an integrated sphere flux measurement system. The correlations between the measurements at different wavelengths were analysed, and the uncertainty boundaries of the integrated quantity and total luminous flux were obtained.
- 29 December 2023
- Published by International Commission on Illumination
- p. 1186-1190
UNCERTAINTY EVALUATION OF HORTICULTURAL LEDs AND MONTE CARLO SIMULATION APPROACH
In the fields of photometry and radiometry, spectral measurements play a crucial role in determining various parameters. The photometric parameters like total luminous flux, colour coordinates, etc. are attained by integrating spectral quantities. The integrated quantity uncertainty analyses can be complex for the calculation by GUM approach. Uncertainty analysis including the correlations effect can be done by Monte Carlo simulation. This study shows both approaches, i.e. with and without correlations, for the uncertainty analysis of the flux of a horticultural LED.
- 29 December 2023
- Published by International Commission on Illumination
- p. 1186-1190
UNCERTAINTY EVALUATION OF HORTICULTURAL LEDs AND MONTE CARLO SIMULATION APPROACH
In the fields of photometry and radiometry, spectral measurements play a crucial role in determining various parameters. The photometric parameters like total luminous flux, colour coordinates, etc. are attained by integrating spectral quantities. The integrated quantity uncertainty analyses can be complex for the calculation by GUM approach. Uncertainty analysis including the correlations effect can be done by Monte Carlo simulation. This study shows both approaches, i.e. with and without correlations, for the uncertainty analysis of the flux of a horticultural LED.
- Open Access
- 26 June 2011
- Published by Wiley in International Journal of Photoenergy
- Vol. 2011, 1-8
-Based Organic Hybrid Solar Cells with Doping
A hybrid solar cell is designed and proposed as a feasible and reasonable alternative, according to acquired efficiency with the employment of TiO2(titanium dioxide) and Mn-doped TiO2thin films. In the scope of this work, TiO2(titanium dioxide) and Mn:TiO2hybrid organic thin films are proposed as charge transporter layer in polymer solar cells. Poly(3-hexylthiophene):phenyl-C61-butyric acid methyl ester (P3HT: PCBM) is used as active layer. When the Mn-doped TiO2solar cells were compared with pure TiO2cells, Mn-doped samples revealed a noteworthy efficiency enhancement with respect to undoped-TiO2-based cells. The highest conversion efficiency was obtained to be 2.44% at the ratio of 3.5% (wt/wt) Mn doping.
- 26 June 2011
- Published by Wiley in International Journal of Photoenergy
- Vol. 2011, 1-8
Open Access-Based Organic Hybrid Solar Cells with Doping
A hybrid solar cell is designed and proposed as a feasible and reasonable alternative, according to acquired efficiency with the employment of TiO2(titanium dioxide) and Mn-doped TiO2thin films. In the scope of this work, TiO2(titanium dioxide) and Mn:TiO2hybrid organic thin films are proposed as charge transporter layer in polymer solar cells. Poly(3-hexylthiophene):phenyl-C61-butyric acid methyl ester (P3HT: PCBM) is used as active layer. When the Mn-doped TiO2solar cells were compared with pure TiO2cells, Mn-doped samples revealed a noteworthy efficiency enhancement with respect to undoped-TiO2-based cells. The highest conversion efficiency was obtained to be 2.44% at the ratio of 3.5% (wt/wt) Mn doping.