Jong Hwa Jun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jong Hwa Jun has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Seung Pil Bang
Department of Ophthalmology, Keimyung University School of Medicine, Daegu 42601, Republic of Korea
13 shared publications Kyu Young Shim
Department of Ophthalmology, Keimyung University School of Medicine, 1035 Dalgubeol-daero, Dalseo-gu, Daegu, 42601, Republic of Korea
7 shared publicationsHarim Kim
Affiliation Department of Ophthalmology, Keimyung University School of Medicine, Daegu, Republic of Korea
5 shared publicationsKun Moon
Seoul Balgeunsesang Eye Clinic, Seoul, South Korea
4 shared publicationsYou Hyun Lee
Affiliation Department of Ophthalmology, Keimyung University School of Medicine, Daegu, Republic of Korea
4 shared publicationsJae-Gon Kim
Department of Ophthalmology, Keimyung University School of Medicine, Daegu, Republic of Korea
3 shared publications
Latest Publications
- Open Access
- 13 October 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 35591
Tear matrix metalloproteinase 9 immunoassay positivity reflects the severity of conjunctivochalasis
An objective indicator for diagnosing and evaluating the therapeutic efficacy of conjunctivochalasis (CCh) treatments is not available. Therefore, we investigated the correlation between CCh severity and the matrix metalloproteinase-9 (MMP)-9 point-of-care (POC) semi-quantitative test to determine its suitability for diagnosing and evaluating CCh. We conducted a prospective study comprising healthy participants and patients with evaporative dry eyes and CCh. The participants underwent CCh severity, tear break-up time, Schirmer test, ocular staining score, tear meniscus height, and tear MMP-9 evaluations. The MMP-9 test results were classified into negative and weakly, moderately, and strongly positive. We included 108 participants; 54 participants had CCh and 54 did not. The MMP-9 positivity rate was significantly higher for patients with ≥ CCh grade 2 than those without CCh (p < 0.001). Of the CCh-negative participants, 75.9% were MMP-9-negative, and 24.1% were moderately/strongly positive. Conversely, 37.0% of CCh-positive patients were MMP-9-negative, and 63.0% were moderately/strongly positive. Furthermore, MMP-9 positivity significantly differed among the CCh severity groups (p < 0.001). Finally, there was a positive correlation between CCh severity and MMP-9 positivity (p < 0.001, R = 0.420). The tear MMP-9 positivity correlated with CCh severity. Therefore, the MMP-9 POC test may help diagnose CCh and evaluate its severity after treatment.
- 13 October 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 35591
Open AccessTear matrix metalloproteinase 9 immunoassay positivity reflects the severity of conjunctivochalasis
An objective indicator for diagnosing and evaluating the therapeutic efficacy of conjunctivochalasis (CCh) treatments is not available. Therefore, we investigated the correlation between CCh severity and the matrix metalloproteinase-9 (MMP)-9 point-of-care (POC) semi-quantitative test to determine its suitability for diagnosing and evaluating CCh. We conducted a prospective study comprising healthy participants and patients with evaporative dry eyes and CCh. The participants underwent CCh severity, tear break-up time, Schirmer test, ocular staining score, tear meniscus height, and tear MMP-9 evaluations. The MMP-9 test results were classified into negative and weakly, moderately, and strongly positive. We included 108 participants; 54 participants had CCh and 54 did not. The MMP-9 positivity rate was significantly higher for patients with ≥ CCh grade 2 than those without CCh (p < 0.001). Of the CCh-negative participants, 75.9% were MMP-9-negative, and 24.1% were moderately/strongly positive. Conversely, 37.0% of CCh-positive patients were MMP-9-negative, and 63.0% were moderately/strongly positive. Furthermore, MMP-9 positivity significantly differed among the CCh severity groups (p < 0.001). Finally, there was a positive correlation between CCh severity and MMP-9 positivity (p < 0.001, R = 0.420). The tear MMP-9 positivity correlated with CCh severity. Therefore, the MMP-9 POC test may help diagnose CCh and evaluate its severity after treatment.
- Open Access
- 2 October 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (19) , 6981
Distribution and Demographic Correlates of Ocular Wavefront Aberrations in a Korean Population
Background/Objectives: Ocular wavefront aberrations are clinically relevant for optimizing vision correction and predicting surgical outcomes. This study aimed to establish normative reference ranges for a Korean population by quantifying wavefront aberrations using a Hartmann–Shack wavefront sensor and Zernike coefficients, and to assess correlations with age, sex, and spherical equivalent (SE). Methods: Wavefront aberrations were measured in 98 Koreans (196 eyes) using a Hartmann–Shack aberrometer without cycloplegia. Five repeated measurements per eye at a 6 mm pupil size were averaged. Parameters included Zernike coefficients (Z3–Z20), higher-order aberration (HOA) root mean square (RMS, Z6–Z20), and total RMS (Z3–Z20). Associations with age, sex, and SE were assessed using univariable and multivariable linear mixed-effects models. Second-order polynomial regression assessed nonlinear relationships. Interocular symmetry was evaluated using mirror-symmetry-adjusted Spearman’s correlation and intraclass correlation coefficients (ICCs). Results: Vertical coma (Z7, 0.208 ± 0.174 μm) and spherical aberration (Z12, 0.200 ± 0.161 μm) were the largest contributors to HOA RMS. Mean HOA RMS and total RMS were 0.51 ± 0.21 μm and 3.03 ± 2.51 μm, respectively. HOA RMS increased with age (β = 0.003 μm/year, p = 0.010), whereas total RMS decreased with SE (β = −0.678 μm/D, p < 0.001). Most Zernike coefficients showed positive interocular correlations, with ICCs of 0.75 for total RMS and 0.64 for HOA RMS. Conclusions: In normal Korean eyes, HOAs increased with age and exhibited significant interocular symmetry. Vertical coma and spherical aberration were predominant components. While the pattern was similar to that in Western populations, the absolute values were greater. These normative values may aid future wavefront-guided refractive surgery and presbyopia correction procedures.
- 2 October 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (19) , 6981
Open AccessDistribution and Demographic Correlates of Ocular Wavefront Aberrations in a Korean Population
Background/Objectives: Ocular wavefront aberrations are clinically relevant for optimizing vision correction and predicting surgical outcomes. This study aimed to establish normative reference ranges for a Korean population by quantifying wavefront aberrations using a Hartmann–Shack wavefront sensor and Zernike coefficients, and to assess correlations with age, sex, and spherical equivalent (SE). Methods: Wavefront aberrations were measured in 98 Koreans (196 eyes) using a Hartmann–Shack aberrometer without cycloplegia. Five repeated measurements per eye at a 6 mm pupil size were averaged. Parameters included Zernike coefficients (Z3–Z20), higher-order aberration (HOA) root mean square (RMS, Z6–Z20), and total RMS (Z3–Z20). Associations with age, sex, and SE were assessed using univariable and multivariable linear mixed-effects models. Second-order polynomial regression assessed nonlinear relationships. Interocular symmetry was evaluated using mirror-symmetry-adjusted Spearman’s correlation and intraclass correlation coefficients (ICCs). Results: Vertical coma (Z7, 0.208 ± 0.174 μm) and spherical aberration (Z12, 0.200 ± 0.161 μm) were the largest contributors to HOA RMS. Mean HOA RMS and total RMS were 0.51 ± 0.21 μm and 3.03 ± 2.51 μm, respectively. HOA RMS increased with age (β = 0.003 μm/year, p = 0.010), whereas total RMS decreased with SE (β = −0.678 μm/D, p < 0.001). Most Zernike coefficients showed positive interocular correlations, with ICCs of 0.75 for total RMS and 0.64 for HOA RMS. Conclusions: In normal Korean eyes, HOAs increased with age and exhibited significant interocular symmetry. Vertical coma and spherical aberration were predominant components. While the pattern was similar to that in Western populations, the absolute values were greater. These normative values may aid future wavefront-guided refractive surgery and presbyopia correction procedures.
- Open Access
- 22 September 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (18) , 6688
Comparison of Ocular Wavefront in Seated and Supine Positions Using a Hand-Held Hartmann–Shack Aberrometer
Background/Objectives: Intraoperative aberrometry has gained clinical relevance in correcting aberrations during cataract and corneal refractive surgeries. As wavefront aberrations are typically measured with patients seated, while surgeries are performed supine, this study aimed to compare ocular aberrations between seated and supine positions, using a hand-held Hartmann–Shack aberrometer. Methods: Total ocular wavefront aberrations were measured five times consecutively from cyclopledged eyes for a 6 mm pupil, under three conditions: (1) seated with a holder-fixed mode (reference), (2) seated with a hand-held mode, and (3) supine with a hand-held mode. Condition 2 was included to assess potential measurement errors from the hand-held mode. Repeatability was assessed using the standard deviation of repeated measurements (Srm) and the intraclass correlation coefficient (ICC). Differences among the three conditions were analyzed to evaluate the effects of positional change and hand-held stability on ocular wavefront aberration measurements. Results: Eighteen healthy subjects (36 eyes) were enrolled. The Srms for the sphere were 0.37, 0.38, and 0.40 diopters (D); and for the cylinder, 0.10, 0.10, and 0.11 D, with no significant differences across conditions. ICC values exceeded 0.9 for both lower-order aberrations (LOAs) and higher-order aberrations (HOAs), indicating excellent repeatability. The mean root mean square HOAs (HOA_RMS) were 0.48, 0.49, and 0.45 µm, with no statistically significant differences by position (p = 0.913) or measurement mode (p = 0.966). Conclusions: The hand-held Hartmann–Shack aberrometer demonstrated satisfactory repeatability for LOAs and HOAs. Supine measurements did not differ from seated, supporting the feasibility of extending preoperative results to intraoperative aberrometry, regardless of positional differences.
- 22 September 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (18) , 6688
Open AccessComparison of Ocular Wavefront in Seated and Supine Positions Using a Hand-Held Hartmann–Shack Aberrometer
Background/Objectives: Intraoperative aberrometry has gained clinical relevance in correcting aberrations during cataract and corneal refractive surgeries. As wavefront aberrations are typically measured with patients seated, while surgeries are performed supine, this study aimed to compare ocular aberrations between seated and supine positions, using a hand-held Hartmann–Shack aberrometer. Methods: Total ocular wavefront aberrations were measured five times consecutively from cyclopledged eyes for a 6 mm pupil, under three conditions: (1) seated with a holder-fixed mode (reference), (2) seated with a hand-held mode, and (3) supine with a hand-held mode. Condition 2 was included to assess potential measurement errors from the hand-held mode. Repeatability was assessed using the standard deviation of repeated measurements (Srm) and the intraclass correlation coefficient (ICC). Differences among the three conditions were analyzed to evaluate the effects of positional change and hand-held stability on ocular wavefront aberration measurements. Results: Eighteen healthy subjects (36 eyes) were enrolled. The Srms for the sphere were 0.37, 0.38, and 0.40 diopters (D); and for the cylinder, 0.10, 0.10, and 0.11 D, with no significant differences across conditions. ICC values exceeded 0.9 for both lower-order aberrations (LOAs) and higher-order aberrations (HOAs), indicating excellent repeatability. The mean root mean square HOAs (HOA_RMS) were 0.48, 0.49, and 0.45 µm, with no statistically significant differences by position (p = 0.913) or measurement mode (p = 0.966). Conclusions: The hand-held Hartmann–Shack aberrometer demonstrated satisfactory repeatability for LOAs and HOAs. Supine measurements did not differ from seated, supporting the feasibility of extending preoperative results to intraoperative aberrometry, regardless of positional differences.
- Open Access
- 28 July 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-10
Impact of temporal tear meniscus height on the tear osmolarity measurements
Tear hyperosmolarity plays a crucial role in initiation of inflammatory response and damage to ocular surface epithelia. Accurate measurement of tear osmolarity is essential for dry eye. This prospective observational and experimental study was conducted in 182 eyes of 182 participants, including 115 subjects with dry eye (Sjögren syndrome aqueous-deficient dry eye [SS ADDE], non-SS ADDE, and evaporative DE [EDE]), 36 with conjunctivochalasis (CCh), and 31 normal controls (NC). The ocular surface disease index (OSDI), tear meniscus height (TMH), Schirmer I test, tear matrix metalloproteinase-9 (MMP-9), tear breakup time, and ocular staining score were assessed. Tear osmolarity was measured using the TearLab osmolarity system (Escondido, CA, USA) by applying 1.0 μl tears collected by micropipette to the TearLab test card or by direct contact between the test card and the temporal tear meniscus. For in vitro analyses, osmolarity of 271.25, 300, 347.5, and 395 mOsm/L solutions were measured at various volumes (0.2, 0.5, 1.0, 2.0, and 5.0 μl) with a TearLab osmometer. Tear osmolarity measured by direct contact was higher than that measured by micropipette (13.7 ± 10.5 mOsm/L, p < 0.001). The difference of osmolarities was higher in the non-SS ADDE, SS ADDE, and CCh than in the NC and EDE (p < 0.001 for all). Osmolarity was negatively correlated with Schirmer score and TMH (r = − 0.346, p < 0.001; r = − 0.447, p < 0.001, respectively). The smaller the sample volume, the higher the measured osmolarity in the in vitro analysis at 300 and 347.5 mOsm/L (r = − 0.659, p < 0.01; r = − 0.579, p < 0.05, respectively). The TearLab osmometer tended to report higher tear osmolarity inversely proportional to sample volumes, possibly due to the evaporation effect. Therefore, care should be taken when interpreting tear osmolarity in patients with low tear volume or CCh.
- 28 July 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-10
Open AccessImpact of temporal tear meniscus height on the tear osmolarity measurements
Tear hyperosmolarity plays a crucial role in initiation of inflammatory response and damage to ocular surface epithelia. Accurate measurement of tear osmolarity is essential for dry eye. This prospective observational and experimental study was conducted in 182 eyes of 182 participants, including 115 subjects with dry eye (Sjögren syndrome aqueous-deficient dry eye [SS ADDE], non-SS ADDE, and evaporative DE [EDE]), 36 with conjunctivochalasis (CCh), and 31 normal controls (NC). The ocular surface disease index (OSDI), tear meniscus height (TMH), Schirmer I test, tear matrix metalloproteinase-9 (MMP-9), tear breakup time, and ocular staining score were assessed. Tear osmolarity was measured using the TearLab osmolarity system (Escondido, CA, USA) by applying 1.0 μl tears collected by micropipette to the TearLab test card or by direct contact between the test card and the temporal tear meniscus. For in vitro analyses, osmolarity of 271.25, 300, 347.5, and 395 mOsm/L solutions were measured at various volumes (0.2, 0.5, 1.0, 2.0, and 5.0 μl) with a TearLab osmometer. Tear osmolarity measured by direct contact was higher than that measured by micropipette (13.7 ± 10.5 mOsm/L, p < 0.001). The difference of osmolarities was higher in the non-SS ADDE, SS ADDE, and CCh than in the NC and EDE (p < 0.001 for all). Osmolarity was negatively correlated with Schirmer score and TMH (r = − 0.346, p < 0.001; r = − 0.447, p < 0.001, respectively). The smaller the sample volume, the higher the measured osmolarity in the in vitro analysis at 300 and 347.5 mOsm/L (r = − 0.659, p < 0.01; r = − 0.579, p < 0.05, respectively). The TearLab osmometer tended to report higher tear osmolarity inversely proportional to sample volumes, possibly due to the evaporation effect. Therefore, care should be taken when interpreting tear osmolarity in patients with low tear volume or CCh.
- 1 October 2024
- Published by Wolters Kluwer Health in Retina
- Vol. 44 (10) , e70-e71
Reply
An abstract is unavailable. This article is available as a PDF only.
- 1 October 2024
- Published by Wolters Kluwer Health in Retina
- Vol. 44 (10) , e70-e71
Reply
An abstract is unavailable. This article is available as a PDF only.
- 1 August 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (8) , 840-846
Impact of scleral tunnel length on the position of intraocular lenses in flanged intrascleral haptic fixation
Purpose: To investigate the effect of scleral tunnel length on the effective lens position and tilt of the intraocular lens (IOL) in flanged intrascleral haptic fixation (ISHF) using anterior segment optical coherence tomography (AS-OCT). Setting: Tertiary institution. Design: Retrospective case–control study. Methods: This study included 55 and 42 eyes that underwent ISHF with 1.0 and 2.0 mm scleral tunnels, respectively. 23 eyes that underwent sutured fixation were used as a control. The anterior chamber depth (ACD), scleral tunnel length, incident angle of haptic, and tilting of optic were analyzed using AS-OCT. Results: The mean postoperative ACD, vertical tilt angle, and spherical equivalent of the 1.0 mm were 5.27 ± 0.39 mm, 6.04 ± 4.87 degrees, and 0.38 ± 1.03 diopters, respectively. The ACD and vertical tilt angle of the 1.0 mm were larger than those of the others (P < .001 and P < .05, respectively), and the postoperative spherical equivalent was more hyperopic (P < .05). The 2.0 mm exhibited a lower frequency of tilting greater than 7 degrees. The intereye difference in ACD between in-the-bag fixation and ISHF of the 1.0 mm tunnel was significantly greater than that in the 2.0 mm tunnel (P < .05). The 1.0 mm tunnel had a significantly larger incident angle and a longer tunnel length (P < .001, respectively) and showed a greater difference in the tunnel length on both sides (P < .05). Conclusions: A shorter tunnel yielded a more unstable IOL position, greater variation in angle and tunnel length, and longer ACD during ISHF. An exact 2.0 mm tunnel must be created on both sides to achieve a stable and predictable IOL position.
- 1 August 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (8) , 840-846
Impact of scleral tunnel length on the position of intraocular lenses in flanged intrascleral haptic fixation
Purpose: To investigate the effect of scleral tunnel length on the effective lens position and tilt of the intraocular lens (IOL) in flanged intrascleral haptic fixation (ISHF) using anterior segment optical coherence tomography (AS-OCT). Setting: Tertiary institution. Design: Retrospective case–control study. Methods: This study included 55 and 42 eyes that underwent ISHF with 1.0 and 2.0 mm scleral tunnels, respectively. 23 eyes that underwent sutured fixation were used as a control. The anterior chamber depth (ACD), scleral tunnel length, incident angle of haptic, and tilting of optic were analyzed using AS-OCT. Results: The mean postoperative ACD, vertical tilt angle, and spherical equivalent of the 1.0 mm were 5.27 ± 0.39 mm, 6.04 ± 4.87 degrees, and 0.38 ± 1.03 diopters, respectively. The ACD and vertical tilt angle of the 1.0 mm were larger than those of the others (P < .001 and P < .05, respectively), and the postoperative spherical equivalent was more hyperopic (P < .05). The 2.0 mm exhibited a lower frequency of tilting greater than 7 degrees. The intereye difference in ACD between in-the-bag fixation and ISHF of the 1.0 mm tunnel was significantly greater than that in the 2.0 mm tunnel (P < .05). The 1.0 mm tunnel had a significantly larger incident angle and a longer tunnel length (P < .001, respectively) and showed a greater difference in the tunnel length on both sides (P < .05). Conclusions: A shorter tunnel yielded a more unstable IOL position, greater variation in angle and tunnel length, and longer ACD during ISHF. An exact 2.0 mm tunnel must be created on both sides to achieve a stable and predictable IOL position.
- Open Access
- 5 February 2024
- Published by Korean Ophthalmological Society in Korean Journal of Ophthalmology
- Vol. 38 (1) , 82-84
Partial Descemet Membrane Overlap Due to Previously Grafted Descemet Membrane Remnant: A Case Report
- 5 February 2024
- Published by Korean Ophthalmological Society in Korean Journal of Ophthalmology
- Vol. 38 (1) , 82-84
Open AccessPartial Descemet Membrane Overlap Due to Previously Grafted Descemet Membrane Remnant: A Case Report
- 1 February 2024
- Published by Wolters Kluwer Health in Retina
- Vol. 44 (2) , 324-332
CONTRIBUTION FACTORS OF EFFECTIVE LENS POSITION, TILT, AND DECENTRATION DURING FLANGED SCLERAL FIXATION OF INTRAOCULAR LENS
Purpose: The authors aimed to elucidate the factors related to effective lens position, tilt, and decentration of scleral fixed intraocular lenses (IOLs) with a flanged haptic technique in an artificial eye model using anterior segment optical coherence tomography. Methods: Two bent 27-gauge needles were passed through a 1.0- or 2.0-mm scleral tunnel, 2.0 mm posterior to the limbus and 180° apart. Both haptics of a three-piece IOL were docked with guide needles and externalized. Factors related to the IOL position were analyzed using anterior segment optical coherence tomography and a stereomicroscope. Results: The 1.0-mm scleral tunnel induced a significantly longer effective lens position than the 2.0-mm tunnel and suture fixation (P < 0.05 and P < 0.01, respectively). Discrepancy in scleral tunnel length induced higher decentration of the optic to the opposite side of the haptic-embedded shorter tunnel and tilt perpendicular to the fixed axis than that in the scleral tunnel of the same length (P < 0.001 and P < 0.05, respectively). If the scleral fixation points of both haptics are not exactly 180° apart, the IOL may become decentered and tilted (P < 0.01 and P < 0.05, respectively). Conclusion: In the flanged haptic technique, the length, balance, and position of both scleral tunnels determine IOL effective lens position, tilt, and decentration.
- 1 February 2024
- Published by Wolters Kluwer Health in Retina
- Vol. 44 (2) , 324-332
CONTRIBUTION FACTORS OF EFFECTIVE LENS POSITION, TILT, AND DECENTRATION DURING FLANGED SCLERAL FIXATION OF INTRAOCULAR LENS
Purpose: The authors aimed to elucidate the factors related to effective lens position, tilt, and decentration of scleral fixed intraocular lenses (IOLs) with a flanged haptic technique in an artificial eye model using anterior segment optical coherence tomography. Methods: Two bent 27-gauge needles were passed through a 1.0- or 2.0-mm scleral tunnel, 2.0 mm posterior to the limbus and 180° apart. Both haptics of a three-piece IOL were docked with guide needles and externalized. Factors related to the IOL position were analyzed using anterior segment optical coherence tomography and a stereomicroscope. Results: The 1.0-mm scleral tunnel induced a significantly longer effective lens position than the 2.0-mm tunnel and suture fixation (P < 0.05 and P < 0.01, respectively). Discrepancy in scleral tunnel length induced higher decentration of the optic to the opposite side of the haptic-embedded shorter tunnel and tilt perpendicular to the fixed axis than that in the scleral tunnel of the same length (P < 0.001 and P < 0.05, respectively). If the scleral fixation points of both haptics are not exactly 180° apart, the IOL may become decentered and tilted (P < 0.01 and P < 0.05, respectively). Conclusion: In the flanged haptic technique, the length, balance, and position of both scleral tunnels determine IOL effective lens position, tilt, and decentration.
- 27 March 2023
- Published by Wolters Kluwer Health in Cornea
- Vol. 42 (6) , 766-769
Temporary Pupil Occlusion and Retrolenticular Air Bubble Injection for Descemet Membrane Endothelial Keratoplasty in Vitrectomized Unicameral Eyes
Purpose: The aim of this study was to describe a surgical method that can be easily and safely performed during Descemet membrane endothelial keratoplasty in patients who had previously undergone pars plana vitrectomy with transscleral fixation of the intraocular lens. Methods: This report reviewed 2 Descemet membrane endothelial keratoplasty procedures performed in patients with vitrectomized unicameral eyes. The proposed technique is characterized by the temporary suture of the pupillary aperture to block the forward flow of vitreous humor and prevent the abrupt loss of air tamponade due to backward movement of the air bubble into the vitreous cavity. At the same time, another air bubble is injected behind the scleral-fixated intraocular lens to induce forward movement of the iris–intraocular lens diaphragm through buoyancy. Thus, the depth of the anterior chamber is reduced, allowing easier unscrolling of the Descemet membrane endothelial keratoplasty lenticule. Results: Pupil closure and buoyancy of the air bubble allow the anterior chamber to be separated from the inflow of vitreous cavity fluid and maintained adequately shallow. During the keratoplasty, the graft is then easily unscrolled without the support of the capsular diaphragm. Postoperatively, the air bubble is maintained in the anterior chamber for a sufficient period. Nd:YAG laser suture lysis is performed after complete absorption of the air bubble during outpatient follow-up. Conclusions: Temporary pupil occlusion and retrolenticular air bubble injection provide a stable surgical approach in challenging cases of postvitrectomized unicameral eyes.
- 27 March 2023
- Published by Wolters Kluwer Health in Cornea
- Vol. 42 (6) , 766-769
Temporary Pupil Occlusion and Retrolenticular Air Bubble Injection for Descemet Membrane Endothelial Keratoplasty in Vitrectomized Unicameral Eyes
Purpose: The aim of this study was to describe a surgical method that can be easily and safely performed during Descemet membrane endothelial keratoplasty in patients who had previously undergone pars plana vitrectomy with transscleral fixation of the intraocular lens. Methods: This report reviewed 2 Descemet membrane endothelial keratoplasty procedures performed in patients with vitrectomized unicameral eyes. The proposed technique is characterized by the temporary suture of the pupillary aperture to block the forward flow of vitreous humor and prevent the abrupt loss of air tamponade due to backward movement of the air bubble into the vitreous cavity. At the same time, another air bubble is injected behind the scleral-fixated intraocular lens to induce forward movement of the iris–intraocular lens diaphragm through buoyancy. Thus, the depth of the anterior chamber is reduced, allowing easier unscrolling of the Descemet membrane endothelial keratoplasty lenticule. Results: Pupil closure and buoyancy of the air bubble allow the anterior chamber to be separated from the inflow of vitreous cavity fluid and maintained adequately shallow. During the keratoplasty, the graft is then easily unscrolled without the support of the capsular diaphragm. Postoperatively, the air bubble is maintained in the anterior chamber for a sufficient period. Nd:YAG laser suture lysis is performed after complete absorption of the air bubble during outpatient follow-up. Conclusions: Temporary pupil occlusion and retrolenticular air bubble injection provide a stable surgical approach in challenging cases of postvitrectomized unicameral eyes.
- Open Access
- 25 March 2023
- Published by The Korean Optometry Society and The Korean Contact Lens Study Society in Annals of Optometry and Contact Lens
- Vol. 22 (1) , 7-10
Proper Management for Rigid Gas Permeable Contact and Orthokeratology Lens
Demand for rigid gas permeable contact lens has increased recently. Many complications including microbial keratitis and corneal neovascularization can be induced by inappropriate management and poor hygiene. Despite of the initial education of proper management, actual compliance and adherence to the guideline is significantly low. We reviewed proper management to improve contact lens hygiene and the solutions for cleaning and conditioning contact lens.
- 25 March 2023
- Published by The Korean Optometry Society and The Korean Contact Lens Study Society in Annals of Optometry and Contact Lens
- Vol. 22 (1) , 7-10
Open AccessProper Management for Rigid Gas Permeable Contact and Orthokeratology Lens
Demand for rigid gas permeable contact lens has increased recently. Many complications including microbial keratitis and corneal neovascularization can be induced by inappropriate management and poor hygiene. Despite of the initial education of proper management, actual compliance and adherence to the guideline is significantly low. We reviewed proper management to improve contact lens hygiene and the solutions for cleaning and conditioning contact lens.