Diane Beauchemin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Diane Beauchemin has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
Ahmed Al Hejami
Queen's University, Department of Chemistry, 90 Bader Lane, Kingston, ON K7L 3N6, Canada
9 shared publicationsRam P. Lamsal
Queen's University, Department of Chemistry, 90 Bader Lane, Kingston, ON, K7L 3N6, Canada
6 shared publications- Dirce Pozebon
Instituto de Química, Universidade Federal do Rio Grande do Sul, Porto Alegre, Brazil
5 shared publications - Guilherme Luiz Scheffler
Instituto de Química, Universidade Federal do Rio Grande do Sul, 91501-970 Porto Alegre, Brazil
5 shared publications John Burgener
Burgener Research Inc., 1680 Lakeshore Road West, Unit #2, Mississauga, ON L5J 1J5, Canada
5 shared publicationsNausheen W. Sadiq
Queen's University, Department of Chemistry, 90 Bader Lane, Kingston, ON K7L 3N6, Canada
5 shared publications
Latest Publications
- Open Access
- 6 May 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (6) , 2074-2080
Optimization of an infrared-heated sample introduction system for single-particle inductively coupled plasma mass spectrometry analysis of metal-labelled ion-exchange polymer microparticles
An infrared-heated sample introduction system enables the measurement of 10 µm microparticles that are excluded by standard sample introduction systems.
- 6 May 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (6) , 2074-2080
Open AccessOptimization of an infrared-heated sample introduction system for single-particle inductively coupled plasma mass spectrometry analysis of metal-labelled ion-exchange polymer microparticles
An infrared-heated sample introduction system enables the measurement of 10 µm microparticles that are excluded by standard sample introduction systems.
- Open Access
Bioaccessibility and Risk Assessment of Trace Elements in Mealworms Using Continuous On-Line Leaching Coupled with Inductively Coupled Plasma Mass Spectrometry
Mealworm (Tenebrio molitor) is considered a sustainable protein source and classified as a non-novel food by Health Canada. However, data on safe consumption levels based on bioaccessible metal(loid) concentrations are limited. In this study, a modified continuous on-line leaching method (COLM) coupled with inductively coupled plasma mass spectrometry (ICPMS) was developed to quantify bioaccessible Cr, As, Se, and Cd in mealworm powder. Samples were packed into a transparent polypropylene flash column and sequentially leached with artificial saliva and gastric juice at 37 °C to simulate gastrointestinal digestion, with continuous monitoring of released elements by ICPMS. The proposed method required approximately 70 min per sample as opposed to over 2 h with conventional batch methods. Whereas the bioaccessible concentration of Se was negligible, 13 ± 5 µg/kg Cr, 18 ± 5 µg/kg As and 18 ± 6 µg/kg Cd were released, representing 14%, 15%, and 26% of their total concentration, respectively. Mass balance was verified for Cr, As, Se, and Cd, demonstrating the reliability of the method. Additionally, different sources of elements were revealed by plotting the temporal profile of one element versus that of another element for each gastro-intestinal fluid. A preliminary quantitative risk assessment indicated that adults can safely consume 105 g mealworm per day. Although no significant noncarcinogenic risk was identified, the incremental lifetime cancer risk of 5.2 × 10−6 for As and 1 × 10−6 for Cr exceeds or equals the Ontario threshold, indicating potential concern. This study is the first to apply the COLM to mealworm while integrating bioaccessibility data for a more realistic risk assessment. However, back-pressure issues result in a relative standard deviation up to 39%.
Open AccessBioaccessibility and Risk Assessment of Trace Elements in Mealworms Using Continuous On-Line Leaching Coupled with Inductively Coupled Plasma Mass Spectrometry
Mealworm (Tenebrio molitor) is considered a sustainable protein source and classified as a non-novel food by Health Canada. However, data on safe consumption levels based on bioaccessible metal(loid) concentrations are limited. In this study, a modified continuous on-line leaching method (COLM) coupled with inductively coupled plasma mass spectrometry (ICPMS) was developed to quantify bioaccessible Cr, As, Se, and Cd in mealworm powder. Samples were packed into a transparent polypropylene flash column and sequentially leached with artificial saliva and gastric juice at 37 °C to simulate gastrointestinal digestion, with continuous monitoring of released elements by ICPMS. The proposed method required approximately 70 min per sample as opposed to over 2 h with conventional batch methods. Whereas the bioaccessible concentration of Se was negligible, 13 ± 5 µg/kg Cr, 18 ± 5 µg/kg As and 18 ± 6 µg/kg Cd were released, representing 14%, 15%, and 26% of their total concentration, respectively. Mass balance was verified for Cr, As, Se, and Cd, demonstrating the reliability of the method. Additionally, different sources of elements were revealed by plotting the temporal profile of one element versus that of another element for each gastro-intestinal fluid. A preliminary quantitative risk assessment indicated that adults can safely consume 105 g mealworm per day. Although no significant noncarcinogenic risk was identified, the incremental lifetime cancer risk of 5.2 × 10−6 for As and 1 × 10−6 for Cr exceeds or equals the Ontario threshold, indicating potential concern. This study is the first to apply the COLM to mealworm while integrating bioaccessibility data for a more realistic risk assessment. However, back-pressure issues result in a relative standard deviation up to 39%.
- Open Access
- 19 January 2026
- Published by Canadian Science Publishing in Canadian Journal of Chemistry
Environmental analysis by inductively coupled plasma spectrometry: an interesting journey at Queen’s University
A review of environmental analysis work carried out by the Beauchemin group using inductively coupled plasma (ICP) mass spectrometry (MS) and optical emission spectrometry (OES) over several decades is presented. Using a continuous online leaching method (COLM) with real-time detection by ICPMS allows measurement of the bio-accessibility of elements and can also be used to infer their source. Indeed, unlike batch methods typically used to measure bio-accessibility, the temporal profiles generated with the COLM can readily reveal if different sources of elements are present through several peaks in the temporal profiles. Common sources of different elements can also be revealed through correlations between their temporal profiles. Similarly, Pb isotope ratios obtained as the slope of the linear correlation between the temporal profiles of two Pb isotope can reveal the presence of Pb from tetraethyllead previously employed as antiknock agent in gasoline. Electrothermal vaporization (ETV) coupled to ICPOES allows for the quick analysis of solid samples, eliminating the need for time-consuming digestion. It was successfully applied to the quick quantitative analysis of a variety of environmental samples. This includes clays and soil samples collected during geochemical exploration to locate undercover ore deposits. There is also potential for the direct speciation analysis of solid samples using ETV-ICPOES.
- 19 January 2026
- Published by Canadian Science Publishing in Canadian Journal of Chemistry
Open AccessEnvironmental analysis by inductively coupled plasma spectrometry: an interesting journey at Queen’s University
A review of environmental analysis work carried out by the Beauchemin group using inductively coupled plasma (ICP) mass spectrometry (MS) and optical emission spectrometry (OES) over several decades is presented. Using a continuous online leaching method (COLM) with real-time detection by ICPMS allows measurement of the bio-accessibility of elements and can also be used to infer their source. Indeed, unlike batch methods typically used to measure bio-accessibility, the temporal profiles generated with the COLM can readily reveal if different sources of elements are present through several peaks in the temporal profiles. Common sources of different elements can also be revealed through correlations between their temporal profiles. Similarly, Pb isotope ratios obtained as the slope of the linear correlation between the temporal profiles of two Pb isotope can reveal the presence of Pb from tetraethyllead previously employed as antiknock agent in gasoline. Electrothermal vaporization (ETV) coupled to ICPOES allows for the quick analysis of solid samples, eliminating the need for time-consuming digestion. It was successfully applied to the quick quantitative analysis of a variety of environmental samples. This includes clays and soil samples collected during geochemical exploration to locate undercover ore deposits. There is also potential for the direct speciation analysis of solid samples using ETV-ICPOES.
- Open Access
- 3 January 2026
- Published by Elsevier in Journal of Food Composition and Analysis
- Vol. 150
Bioaccessibility and risk assessment of Pb, Se, Cd and Zn from seaweed
- 3 January 2026
- Published by Elsevier in Journal of Food Composition and Analysis
- Vol. 150
Open AccessBioaccessibility and risk assessment of Pb, Se, Cd and Zn from seaweed
- 27 August 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
Quick Determination of Fourteen Rare Earth Elements in Powdered Refractory Materials Using Electrothermal Vaporization with Detection by Inductively Coupled Plasma Optical Emission Spectrometry
The determination of rare earth elements (REEs) in refractory materials by inductively coupled plasma (ICP) spectrometry with conventional sample introduction using pneumatic nebulization requires the dissolution of these samples, which is difficult. This work presents an optimized method using electrothermal vaporization (ETV) coupled to ICP optical emission spectrometry (OES) for the direct determination of REEs in refractory geological materials. Solid sampling eliminates the dissolution step, thereby increasing sample throughput. Furthermore, the small sample mass required with ETV allows faster analysis with greater sensitivity than with nebulization by eliminating the dilution inherent to dissolution and introducing more sample into the plasma compared to nebulization. Point-by-point internal standardization with an argon emission line compensates for the visible sample loading effect on the plasma. Multivariate optimizations of the carrier, bypass, and CF4 reaction gas flow rates, along with optimization of the pyrolysis temperature and cooling time between the pyrolysis and vaporization steps, enhanced analyte signals by 2.9-11 times compared to a previous ETV-ICPOES method for the analysis of slag. Adding at least 30 μL of high-purity water to the graphite boat containing solid samples enhanced sensitivity by 61% on average and enabled external calibration using standard solutions, which provided accurate results for 14 REEs (Ce, Dy, Er, Eu, Gd, Ho, La, Lu, Nd, Pr, Sm, Tm, Y, and Yb). In contrast, only REEs with certified concentrations in the CRMs encompassing those in the sample could be determined by using CRMs for external calibration.
- 27 August 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
Quick Determination of Fourteen Rare Earth Elements in Powdered Refractory Materials Using Electrothermal Vaporization with Detection by Inductively Coupled Plasma Optical Emission Spectrometry
The determination of rare earth elements (REEs) in refractory materials by inductively coupled plasma (ICP) spectrometry with conventional sample introduction using pneumatic nebulization requires the dissolution of these samples, which is difficult. This work presents an optimized method using electrothermal vaporization (ETV) coupled to ICP optical emission spectrometry (OES) for the direct determination of REEs in refractory geological materials. Solid sampling eliminates the dissolution step, thereby increasing sample throughput. Furthermore, the small sample mass required with ETV allows faster analysis with greater sensitivity than with nebulization by eliminating the dilution inherent to dissolution and introducing more sample into the plasma compared to nebulization. Point-by-point internal standardization with an argon emission line compensates for the visible sample loading effect on the plasma. Multivariate optimizations of the carrier, bypass, and CF4 reaction gas flow rates, along with optimization of the pyrolysis temperature and cooling time between the pyrolysis and vaporization steps, enhanced analyte signals by 2.9-11 times compared to a previous ETV-ICPOES method for the analysis of slag. Adding at least 30 μL of high-purity water to the graphite boat containing solid samples enhanced sensitivity by 61% on average and enabled external calibration using standard solutions, which provided accurate results for 14 REEs (Ce, Dy, Er, Eu, Gd, Ho, La, Lu, Nd, Pr, Sm, Tm, Y, and Yb). In contrast, only REEs with certified concentrations in the CRMs encompassing those in the sample could be determined by using CRMs for external calibration.
- 19 August 2025
- Published by Elsevier in Food and Humanity
- Vol. 5
Bioaccessibility study for toxic and essential elements in novel and conventional high protein foods
- 19 August 2025
- Published by Elsevier in Food and Humanity
- Vol. 5
Bioaccessibility study for toxic and essential elements in novel and conventional high protein foods
- Open Access
- 18 March 2025
- Published by Wiley in Journal of Forensic Sciences
- Vol. 70 (3) , 980-994
Laser‐induced breakdown spectroscopy/laser ablation coupled to inductively coupled plasma mass spectrometry (LIBS/LA‐ICPMS) for the forensic screening and discrimination of lead‐free solders
The tandem LIBS/LA‐ICPMS technique is a desirable tool for the multi‐elemental determination, characterization, and classification of alloys as forensic evidence. In this study, LIBS/LA‐ICPMS is validated for the forensic evaluation of lead‐free solder alloys, which form valuable evidence from post‐blast crime scenes involving homemade and improvised explosive devices. LIBS/LA‐ICPMS is competitive with other spectroscopic‐based forensic techniques as it is in situ, analyzes samples directly, and requires minimal destruction of the exhibit. Following a one‐standard calibration technique, nine major (alloying metals) and trace elements (impurities or additives) are quantified in lead‐free solders. Optimizing laser parameters and using Pb as a naturally occurring internal standard are shown to compensate for mass‐dependent drift and matrix effects. The quantitative results of Pb‐free certified reference materials align with certificate values and with results from two techniques in a cross‐validation comparison, including electrothermal vaporization‐inductively coupled plasma optical emission spectrometry and neutron activation analysis. Utilizing peak ratios in a model of principal component analysis is presented to identify key compositional differences among solders and provide a visual model for solder discrimination. Outcomes of this approach demonstrate the potential for associating or discriminating lead‐free solders, including different solders from the same manufacturer. Together, this technique can establish chemical concordance among known and questioned materials and offers a utilitarian approach for the forensic assessment of trace evidence.
- 18 March 2025
- Published by Wiley in Journal of Forensic Sciences
- Vol. 70 (3) , 980-994
Open AccessLaser‐induced breakdown spectroscopy/laser ablation coupled to inductively coupled plasma mass spectrometry (LIBS/LA‐ICPMS) for the forensic screening and discrimination of lead‐free solders
The tandem LIBS/LA‐ICPMS technique is a desirable tool for the multi‐elemental determination, characterization, and classification of alloys as forensic evidence. In this study, LIBS/LA‐ICPMS is validated for the forensic evaluation of lead‐free solder alloys, which form valuable evidence from post‐blast crime scenes involving homemade and improvised explosive devices. LIBS/LA‐ICPMS is competitive with other spectroscopic‐based forensic techniques as it is in situ, analyzes samples directly, and requires minimal destruction of the exhibit. Following a one‐standard calibration technique, nine major (alloying metals) and trace elements (impurities or additives) are quantified in lead‐free solders. Optimizing laser parameters and using Pb as a naturally occurring internal standard are shown to compensate for mass‐dependent drift and matrix effects. The quantitative results of Pb‐free certified reference materials align with certificate values and with results from two techniques in a cross‐validation comparison, including electrothermal vaporization‐inductively coupled plasma optical emission spectrometry and neutron activation analysis. Utilizing peak ratios in a model of principal component analysis is presented to identify key compositional differences among solders and provide a visual model for solder discrimination. Outcomes of this approach demonstrate the potential for associating or discriminating lead‐free solders, including different solders from the same manufacturer. Together, this technique can establish chemical concordance among known and questioned materials and offers a utilitarian approach for the forensic assessment of trace evidence.
- Open Access
Multi-Elemental Analysis of Edible Insects, Scorpions, and Tarantulas from French (Online) Market and Human Health Risk Assessment Due to Their Consumption: A Pilot Study
Edible insects are becoming increasingly popular as protein alternatives to traditional animal-based products. As such, information on their elemental composition is important to ensure they are safe for human consumption. This article describes the development and validation of a rapid, reliable method for the simultaneous determination of 19 elements (Al, As, B, Ba, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Pb, Se, Sr, and Zn) in edible insects by inductively coupled plasma mass spectrometry (ICP-MS) following closed vessel microwave digestion. The method was validated using three insect certified reference materials, namely black soldier fly larvae meal (BFLY-1), cricket flour (KRIK-1), and mealworm powder (VORM-1). The method was applied to analyze twelve different (whole) insect species. The maximum amount of each sample was calculated for As, Cd, and Pb with respect to their provisional tolerable daily intake values established by the Food and Agricultural Organization/World Health Organization. Most of the samples, except for scorpions and tarantulas, were safe to consume at large doses (1000–10,000 insects per day). Furthermore, most of the samples contained high levels of Fe, K, Na, and Zn, providing a preliminary overview of the nutritional profile of these novel protein alternatives.
Open AccessMulti-Elemental Analysis of Edible Insects, Scorpions, and Tarantulas from French (Online) Market and Human Health Risk Assessment Due to Their Consumption: A Pilot Study
Edible insects are becoming increasingly popular as protein alternatives to traditional animal-based products. As such, information on their elemental composition is important to ensure they are safe for human consumption. This article describes the development and validation of a rapid, reliable method for the simultaneous determination of 19 elements (Al, As, B, Ba, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Pb, Se, Sr, and Zn) in edible insects by inductively coupled plasma mass spectrometry (ICP-MS) following closed vessel microwave digestion. The method was validated using three insect certified reference materials, namely black soldier fly larvae meal (BFLY-1), cricket flour (KRIK-1), and mealworm powder (VORM-1). The method was applied to analyze twelve different (whole) insect species. The maximum amount of each sample was calculated for As, Cd, and Pb with respect to their provisional tolerable daily intake values established by the Food and Agricultural Organization/World Health Organization. Most of the samples, except for scorpions and tarantulas, were safe to consume at large doses (1000–10,000 insects per day). Furthermore, most of the samples contained high levels of Fe, K, Na, and Zn, providing a preliminary overview of the nutritional profile of these novel protein alternatives.
- Open Access
- 4 July 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 39 (8) , 2078-2086
Towards the best total consumption infrared-heated sample introduction system for nanoparticle measurement using single particle inductively coupled plasma mass spectrometry
A compact infrared-heated sample introduction system allows total consumption, thereby allowing the analysis of nanoparticles without measurement of transport efficiency.
- 4 July 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 39 (8) , 2078-2086
Open AccessTowards the best total consumption infrared-heated sample introduction system for nanoparticle measurement using single particle inductively coupled plasma mass spectrometry
A compact infrared-heated sample introduction system allows total consumption, thereby allowing the analysis of nanoparticles without measurement of transport efficiency.