Guilherme Luiz Scheffler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Guilherme Luiz Scheffler has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Dirce Pozebon
Instituto de Química, Universidade Federal do Rio Grande do Sul, Porto Alegre, Brazil
18 shared publications - Diane Beauchemin
Queen's University, Department of Chemistry, 90 Bader Lane, Kingston, ON K7L 3N6, Canada
5 shared publications - Valderi Luiz Dressler
Universidade Federal de Santa Maria (UFSM), Brasil
4 shared publications Camila Alves Martins
Instituto de Química, Universidade Federal do Rio Grande do Sul, 91501-970 Porto Alegre, Brazil
2 shared publicationsAdam J. Brooks
Department of Chemistry, Queen's University, Kingston, Canada
1 shared publicationC. A. Martins
Universidade Federal do Rio Grande do Sul, Instituto de Química, Porto Alegre, Brazil
1 shared publication
Latest Publications
- 7 February 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (5) , 891-898
Improving the analytical performance of electrothermal vaporization coupled to inductively coupled plasma optical emission spectrometry using a mixed-gas plasma
A robust Ar–N2 mixed-gas plasma is proposed to improve the analytical performance of electrothermal vapourization (ETV) coupled to inductively coupled plasma optical emission spectrometry (ICPOES). With 0.4 L min−1 of N2 in the plasma gas flow and 20 mL min−1 of N2 sheathing gas in the central channel of the ICP, sensitivity based on peak area increased by up to 32 fold (Ba) and detection limits improved by up to 300 fold (Ba). Detection limits, based on 3 mg aliquots, ranged from 0.007 (Mo, Sb) to 100 (Mg) mg kg−1 with the mixed-gas plasma versus 0.01 (Tl) – 3000 (Al) mg kg−1 with an Ar plasma. Such improvement was in general more important for ionic than atomic emission lines under the optimized ETV conditions: 8 mL min−1 CHF3 (as chemical modifier), 0.15 L min−1 Ar carrier gas, 0.50 L min−1 Ar by-pass gas, 400 °C pyrolysis for 20 s; cool down to 20 °C for 15 s and 2200 °C vaporization for 30 s. The relative standard deviation ranged from 0.4 to 19% for 3 mg soil replicates (n = 10). Point-by-point internal standardization with Ar I 763.511 nm was systematically applied to compensate for sample loading effects in the ICP. The lower suppression of the Ar I 763.511 nm signal caused by the ETV effluent in the mixed-gas plasma compared to an Ar plasma confirmed the higher robustness of the mixed-gas plasma. Additional studies revealed that only Ar atomic emission lines (at 763.511, 415.859 and 420.067 nm) with similar energy (11.5 eV) to that of Ar metastable species (Arm) showed reproducible suppression, suggesting a major role of Arm on plasma-related matrix effects. Accurate results were obtained for 41–65% of the elements with certified concentrations in three soil certified reference materials by direct soil analysis using another soil certified reference material for external calibration.
- 7 February 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (5) , 891-898
Improving the analytical performance of electrothermal vaporization coupled to inductively coupled plasma optical emission spectrometry using a mixed-gas plasma
A robust Ar–N2 mixed-gas plasma is proposed to improve the analytical performance of electrothermal vapourization (ETV) coupled to inductively coupled plasma optical emission spectrometry (ICPOES). With 0.4 L min−1 of N2 in the plasma gas flow and 20 mL min−1 of N2 sheathing gas in the central channel of the ICP, sensitivity based on peak area increased by up to 32 fold (Ba) and detection limits improved by up to 300 fold (Ba). Detection limits, based on 3 mg aliquots, ranged from 0.007 (Mo, Sb) to 100 (Mg) mg kg−1 with the mixed-gas plasma versus 0.01 (Tl) – 3000 (Al) mg kg−1 with an Ar plasma. Such improvement was in general more important for ionic than atomic emission lines under the optimized ETV conditions: 8 mL min−1 CHF3 (as chemical modifier), 0.15 L min−1 Ar carrier gas, 0.50 L min−1 Ar by-pass gas, 400 °C pyrolysis for 20 s; cool down to 20 °C for 15 s and 2200 °C vaporization for 30 s. The relative standard deviation ranged from 0.4 to 19% for 3 mg soil replicates (n = 10). Point-by-point internal standardization with Ar I 763.511 nm was systematically applied to compensate for sample loading effects in the ICP. The lower suppression of the Ar I 763.511 nm signal caused by the ETV effluent in the mixed-gas plasma compared to an Ar plasma confirmed the higher robustness of the mixed-gas plasma. Additional studies revealed that only Ar atomic emission lines (at 763.511, 415.859 and 420.067 nm) with similar energy (11.5 eV) to that of Ar metastable species (Arm) showed reproducible suppression, suggesting a major role of Arm on plasma-related matrix effects. Accurate results were obtained for 41–65% of the elements with certified concentrations in three soil certified reference materials by direct soil analysis using another soil certified reference material for external calibration.
- 16 July 2018
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 33 (9) , 1486-1492
Risk assessment of trace elements in airborne particulate matter deposited on air filters using solid sampling ETV-ICPOES to measure total concentrations and leaching with simulated saliva, gastric juice and lung fluid to estimate bio-accessibility
Potentially toxic elements (PTEs) in airborne particulate matter (APM) can cause adverse effects on human health, especially in urban and (current and former) industrial areas. The severity of health effects depends on the availability of the PTEs for absorption into the human body. The bio-accessible fraction of PTEs in APM, i.e. released in the gastrointestinal tract and lungs, was estimated in the present study. Polytetrafluoroethylene (PTFE) filters containing previously collected airborne particulate matter were directly analysed by electrothermal vaporisation into inductively coupled plasma optical emission spectrometry (ETV-ICPOES) to obtain the total concentrations of several trace elements (Sb, As, Cd, Cr, Cu, Mn, Ni, Pb, Sr, V and Zn). The results were cross-validated using inductively coupled plasma mass spectrometry (ICPMS) analysis of acid-digested samples. Subsequently, the bio-accessibility of the investigated elements was estimated by leaching the filters with simulated saliva (for 10 min, pH 6.5) and gastric juice (for 2 h, pH < 1). Separate aliquots were also leached with lung fluid (pH 7.4) for 1 h to 56 h. Two leaching groups were identified with saliva: As, Cr, Cu and Sb (2.5% released), and Cr, Sr and Zn (15% released). With gastric juice, 26% of As, Cr, Cu, Ni and Sb, and 77% of Zn, Sr and Pb were released on average. With lung fluid, 56 h leaching was as follows: Sb, 1.1%; As, 2.2%; Cr, 78%; Cu, 9%; Ni, 62%; Pb, 61%; Sr, 46%; V, 32%; and Zn, 89%. The high bio-accessibility of Pb in gastric juice and lung fluid may pose a health risk if such APM is inhaled or swallowed.
- 16 July 2018
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 33 (9) , 1486-1492
Risk assessment of trace elements in airborne particulate matter deposited on air filters using solid sampling ETV-ICPOES to measure total concentrations and leaching with simulated saliva, gastric juice and lung fluid to estimate bio-accessibility
Potentially toxic elements (PTEs) in airborne particulate matter (APM) can cause adverse effects on human health, especially in urban and (current and former) industrial areas. The severity of health effects depends on the availability of the PTEs for absorption into the human body. The bio-accessible fraction of PTEs in APM, i.e. released in the gastrointestinal tract and lungs, was estimated in the present study. Polytetrafluoroethylene (PTFE) filters containing previously collected airborne particulate matter were directly analysed by electrothermal vaporisation into inductively coupled plasma optical emission spectrometry (ETV-ICPOES) to obtain the total concentrations of several trace elements (Sb, As, Cd, Cr, Cu, Mn, Ni, Pb, Sr, V and Zn). The results were cross-validated using inductively coupled plasma mass spectrometry (ICPMS) analysis of acid-digested samples. Subsequently, the bio-accessibility of the investigated elements was estimated by leaching the filters with simulated saliva (for 10 min, pH 6.5) and gastric juice (for 2 h, pH < 1). Separate aliquots were also leached with lung fluid (pH 7.4) for 1 h to 56 h. Two leaching groups were identified with saliva: As, Cr, Cu and Sb (2.5% released), and Cr, Sr and Zn (15% released). With gastric juice, 26% of As, Cr, Cu, Ni and Sb, and 77% of Zn, Sr and Pb were released on average. With lung fluid, 56 h leaching was as follows: Sb, 1.1%; As, 2.2%; Cr, 78%; Cu, 9%; Ni, 62%; Pb, 61%; Sr, 46%; V, 32%; and Zn, 89%. The high bio-accessibility of Pb in gastric juice and lung fluid may pose a health risk if such APM is inhaled or swallowed.
- Open Access
- 22 May 2018
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 33 (7) , 1269-1273
A comparative study of sheathing devices to increase robustness in inductively coupled plasma optical emission spectrometry via a nitrogen flow
Five different glass sheathing devices were used to introduce 20 mL min−1 N2 sheathing gas around the effluent from the spray chamber to see the effect of their dimensions on plasma robustness as measured using the Mg II 280.270 nm/Mg I 285.213 nm emission signal ratio in inductively coupled plasma (ICP) optical emission spectrometry (OES). A clear relationship between device dimensions and the plasma robustness profile along the ICP central channel was observed. With an aerosol inlet having an inner diameter of 1.0 cm in the sheathing device, mixing of N2 with the aerosol was minimised and the resulting sheath increased robustness, the higher thermal conductivity of N2versus Ar likely improving energy transfer between the bulk plasma and the central channel. The configuration of the outlet is also important, as any bottleneck favours mixing of N2 with the aerosol, which in turn cools the plasma, thereby shifting the region of maximum robustness to higher above the load coil. Regardless of device dimensions, plasma robustness was always better with N2 sheathing gas. An increased ion-to-atom emission signal ratio also resulted for other elements than Mg. The presence of N2 also seems to affect excitation mechanisms, such as charge transfer between NO+ and Cd or Ni, which appears to take place at higher observation height, after N2 has had enough time to diffuse into the central channel.
- 22 May 2018
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 33 (7) , 1269-1273
Open AccessA comparative study of sheathing devices to increase robustness in inductively coupled plasma optical emission spectrometry via a nitrogen flow
Five different glass sheathing devices were used to introduce 20 mL min−1 N2 sheathing gas around the effluent from the spray chamber to see the effect of their dimensions on plasma robustness as measured using the Mg II 280.270 nm/Mg I 285.213 nm emission signal ratio in inductively coupled plasma (ICP) optical emission spectrometry (OES). A clear relationship between device dimensions and the plasma robustness profile along the ICP central channel was observed. With an aerosol inlet having an inner diameter of 1.0 cm in the sheathing device, mixing of N2 with the aerosol was minimised and the resulting sheath increased robustness, the higher thermal conductivity of N2versus Ar likely improving energy transfer between the bulk plasma and the central channel. The configuration of the outlet is also important, as any bottleneck favours mixing of N2 with the aerosol, which in turn cools the plasma, thereby shifting the region of maximum robustness to higher above the load coil. Regardless of device dimensions, plasma robustness was always better with N2 sheathing gas. An increased ion-to-atom emission signal ratio also resulted for other elements than Mg. The presence of N2 also seems to affect excitation mechanisms, such as charge transfer between NO+ and Cd or Ni, which appears to take place at higher observation height, after N2 has had enough time to diffuse into the central channel.
- 1 November 2017
- Published by Elsevier in Analytica Chimica Acta
- Vol. 992, 1-23
Elemental hair analysis: A review of procedures and applications
- 1 November 2017
- Published by Elsevier in Analytica Chimica Acta
- Vol. 992, 1-23
Elemental hair analysis: A review of procedures and applications
- 21 July 2017
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 32 (10) , 2041-2045
Solid sampling analysis of a Mg alloy using electrothermal vaporization inductively coupled plasma optical emission spectrometry
Electrothermal vaporization hyphenated with inductively coupled plasma optical emission spectrometry (ETV-ICPOES) was applied to the analysis of the AZ31 Mg alloy in an attempt to quantify Al, Cu, Mn, Ni and Zn. Small pieces of the alloy were simply placed in graphite boats for automated insertion into the ETV graphite furnace. The optimized ETV conditions included a carrier gas flow rate of 0.15 L min−1 and an argon by-pass flow rate of 0.50 L min−1, along with 8 mL min−1 Freon 23 (CHF3, trifluoromethane) as the reaction gas. The heating program included pyrolysis (400 °C for 20 s), cooling (20 °C for 15 s), atomization (2200 °C for 30 s) and cooling (20 °C for 20 s) steps. The peak area of each transient signal was integrated (over 50 s) after point-by-point internal standardization with Ar emission (at 415.859 nm) to compensate for loading effects. To build calibration curves, 1 to 6 mg of certified reference material NIST 1648a (Urban Particulate Matter) was weighed into graphite boats. The limits of quantification based on 10 times the standard deviation of the blank (using empty graphite boats and based on 3 mg sample) ranged from 0.2 mg kg−1 (Cu) to 400 mg kg−1 (Ca). The analytes' concentrations obtained were in reasonable agreement with both the reported values and those found after digestion by ICPOES or ICP mass spectrometry. Hence, ETV-ICPOES shows great potential for fast screening of minor and trace elements in Mg alloys.
- 21 July 2017
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 32 (10) , 2041-2045
Solid sampling analysis of a Mg alloy using electrothermal vaporization inductively coupled plasma optical emission spectrometry
Electrothermal vaporization hyphenated with inductively coupled plasma optical emission spectrometry (ETV-ICPOES) was applied to the analysis of the AZ31 Mg alloy in an attempt to quantify Al, Cu, Mn, Ni and Zn. Small pieces of the alloy were simply placed in graphite boats for automated insertion into the ETV graphite furnace. The optimized ETV conditions included a carrier gas flow rate of 0.15 L min−1 and an argon by-pass flow rate of 0.50 L min−1, along with 8 mL min−1 Freon 23 (CHF3, trifluoromethane) as the reaction gas. The heating program included pyrolysis (400 °C for 20 s), cooling (20 °C for 15 s), atomization (2200 °C for 30 s) and cooling (20 °C for 20 s) steps. The peak area of each transient signal was integrated (over 50 s) after point-by-point internal standardization with Ar emission (at 415.859 nm) to compensate for loading effects. To build calibration curves, 1 to 6 mg of certified reference material NIST 1648a (Urban Particulate Matter) was weighed into graphite boats. The limits of quantification based on 10 times the standard deviation of the blank (using empty graphite boats and based on 3 mg sample) ranged from 0.2 mg kg−1 (Cu) to 400 mg kg−1 (Ca). The analytes' concentrations obtained were in reasonable agreement with both the reported values and those found after digestion by ICPOES or ICP mass spectrometry. Hence, ETV-ICPOES shows great potential for fast screening of minor and trace elements in Mg alloys.
- Top Cited Papers
- 14 March 2017
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 32 (5) , 890-919
Recent applications of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) for biological sample analysis: a follow-up review
Information provided by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) in the analysis of biological tissues is expanding.
- 14 March 2017
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 32 (5) , 890-919
Top Cited PapersRecent applications of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) for biological sample analysis: a follow-up review
Information provided by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) in the analysis of biological tissues is expanding.
- 1 November 2016
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 31 (12) , 2434-2440
Direct determination of trace elements in austenitic stainless steel samples by ETV-ICPOES
Electrothermal vaporization (ETV) coupled to inductively coupled plasma optical emission spectrometry (ICPOES) was applied to the direct analysis of austenitic stainless steel powders using external calibration with increasing amounts of urban particulate matter (NIST 1648a) certified reference material. The method was first validated through the analysis of a reference material of free cutting steel, BCS 152/3, which was also analysed, following digestion in aqua regia, by ICPOES with external calibration using matrix-matched standard solutions. A four-step heating program, where the 30 s vaporization step was not ramped and followed a cooling step after pyrolysis, was used along with hemi-spherical graphite boats and trifluoromethane (CHF3, freon R-23) reaction gas, which resulted in sharp analyte signal peaks. Internal standardization with an argon emission line (415.859 nm) was applied throughout to compensate for sample loading effects on the plasma, improve the signal-to-background ratio and extend the linear dynamic range. Quantification limits ranged from 0.02 (Cd) to 200 (Si) μg g−1 in the solid using 5 mg aliquots, and are one or two orders of magnitude lower than those obtained by ICPOES with nebulization for several elements. The proposed method allowed determination of Al, Cd, Ce, Co, Cu, Mn, Pb, S, Si, Ti, V and Zn at levels in the 10 μg g−1 to 0.4% (m m−1) range, in agreement with results obtained by ICPOES following digestion. The method is suitable for alloy quality control, as it drastically reduces analysis time and cost by eliminating the acid digestion step altogether, which is quite attractive for industrial applications.
- 1 November 2016
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 31 (12) , 2434-2440
Direct determination of trace elements in austenitic stainless steel samples by ETV-ICPOES
Electrothermal vaporization (ETV) coupled to inductively coupled plasma optical emission spectrometry (ICPOES) was applied to the direct analysis of austenitic stainless steel powders using external calibration with increasing amounts of urban particulate matter (NIST 1648a) certified reference material. The method was first validated through the analysis of a reference material of free cutting steel, BCS 152/3, which was also analysed, following digestion in aqua regia, by ICPOES with external calibration using matrix-matched standard solutions. A four-step heating program, where the 30 s vaporization step was not ramped and followed a cooling step after pyrolysis, was used along with hemi-spherical graphite boats and trifluoromethane (CHF3, freon R-23) reaction gas, which resulted in sharp analyte signal peaks. Internal standardization with an argon emission line (415.859 nm) was applied throughout to compensate for sample loading effects on the plasma, improve the signal-to-background ratio and extend the linear dynamic range. Quantification limits ranged from 0.02 (Cd) to 200 (Si) μg g−1 in the solid using 5 mg aliquots, and are one or two orders of magnitude lower than those obtained by ICPOES with nebulization for several elements. The proposed method allowed determination of Al, Cd, Ce, Co, Cu, Mn, Pb, S, Si, Ti, V and Zn at levels in the 10 μg g−1 to 0.4% (m m−1) range, in agreement with results obtained by ICPOES following digestion. The method is suitable for alloy quality control, as it drastically reduces analysis time and cost by eliminating the acid digestion step altogether, which is quite attractive for industrial applications.
- 23 March 2016
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 31 (5) , 1141-1149
Experimental evidence of enhanced water dissociation and spatially dependent charge-transfer reactions in mix-gas inductively coupled plasma optical emission spectrometry
A microporous membrane fitted to a pneumatic nebulizer–desolvation system was employed for introducing the sample solution into the ICP, reducing the water loading and magnifying the effect of a low flow of N2 in the drier ICP.
- 23 March 2016
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 31 (5) , 1141-1149
Experimental evidence of enhanced water dissociation and spatially dependent charge-transfer reactions in mix-gas inductively coupled plasma optical emission spectrometry
A microporous membrane fitted to a pneumatic nebulizer–desolvation system was employed for introducing the sample solution into the ICP, reducing the water loading and magnifying the effect of a low flow of N2 in the drier ICP.
- 7 December 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (3) , 504-509
Straightforward determination of U, Th, and Hf at trace levels using ultrasonic nebulization and axial view ICP OES
Inductively coupled plasma optical emission spectrometry (ICP OES) is applied for direct determination of U, Th and Hf in environmental and geological samples (phosphate rock, soil, sediment, bush branches and leaves, and natural water). Several spectral lines and sample decomposition procedures were investigated with respect to spectral and non-spectral interference. For U and Hf determination, the geological sample treatment required hydrofluoric acid, whereas Th could be accurately determined in the samples decomposed by aqua regia solely. Ultrasonic nebulization (USN) and pneumatic nebulization with aerosol desolvation (PN-DES), with and without a microporous membrane, were evaluated for introducing the sample solution into the ICP. Better results were obtained by using USN; the limits of detection for U (U II 409.014 nm), Th (Th II 401.913 nm) and Hf (Hf II 264.141 nm) were 0.03, 0.01, and 0.01 μg g−1, respectively. Uranium, Th and Hf were precisely and accurately determined without matrix separation/analyte pre-concentration; the relative standard deviation (RSD) was typically <7% and the recovery of the analytes in the certified reference materials (phosphate rock, soil, sediment, bush, branches and leaves, and natural water) ranged from 83 to 112%. These results were linked to careful selection of spectral lines, which depended on the sample matrix and reagents used for sample decomposition.
- 7 December 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (3) , 504-509
Straightforward determination of U, Th, and Hf at trace levels using ultrasonic nebulization and axial view ICP OES
Inductively coupled plasma optical emission spectrometry (ICP OES) is applied for direct determination of U, Th and Hf in environmental and geological samples (phosphate rock, soil, sediment, bush branches and leaves, and natural water). Several spectral lines and sample decomposition procedures were investigated with respect to spectral and non-spectral interference. For U and Hf determination, the geological sample treatment required hydrofluoric acid, whereas Th could be accurately determined in the samples decomposed by aqua regia solely. Ultrasonic nebulization (USN) and pneumatic nebulization with aerosol desolvation (PN-DES), with and without a microporous membrane, were evaluated for introducing the sample solution into the ICP. Better results were obtained by using USN; the limits of detection for U (U II 409.014 nm), Th (Th II 401.913 nm) and Hf (Hf II 264.141 nm) were 0.03, 0.01, and 0.01 μg g−1, respectively. Uranium, Th and Hf were precisely and accurately determined without matrix separation/analyte pre-concentration; the relative standard deviation (RSD) was typically <7% and the recovery of the analytes in the certified reference materials (phosphate rock, soil, sediment, bush, branches and leaves, and natural water) ranged from 83 to 112%. These results were linked to careful selection of spectral lines, which depended on the sample matrix and reagents used for sample decomposition.