Yunus Dere
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yunus Dere has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
E.D. Sotelino
3 shared publications- Elisa D. Sotelino
Assistant Professor, Dept. of Civil and Environmental Engineering, Michigan Technological Univ., Houghton, MI 49931
2 shared publications - Musa Hakan Arslan
Konya Technical University
2 shared publications - Ahmet Yurteri
Department of Orthopaedics and Traumatology, Konya City Hospital, Konya, Türkiye
1 shared publication - Ali Serdar Ecemiş
Department of Civil Engineering, Necmettin Erbakan University, 42090 Konya, Türkiye
1 shared publication Alireza Asgari
1 shared publication
Latest Publications
- Open Access
- 1 August 2024
- Published by Pontificia Universidad Catolica de Chile
- Vol. 23 (2) , 177-202
Investigation of plastic hinge length in high-ductility reinforced concrete shear walls
In this study, the plastic hinge lengths of reinforced concrete (R/C) cantilever shear walls were analytically determined considering various design parameters. Nonlinear static (Pushover) analyses were conducted on R/C shear wall models and their nonlinear behavior was examined using ABAQUS software. In the study, 72 shear wall models with different parameters were analyzed under the influence of vertical and horizontal loads. Parameters whose effects on plastic hinge length were investigated height/length ratio (Hw/Lw), axial load ratio (N/No), and horizontal web reinforcement ratio (ρsh). The load-displacement graphs of the modelled shear walls were obtained. The plastic hinge height of shear walls was determined according to the heights of the deformations in the concrete and longitudinal steel reinforcement in the section when the shear walls lateral load decreased by 15%. The analytical plastic hinge lengths (Lpz) were determined with respect to the location of the yield occurred at the longitudinal steel reinforcement of the shear wall. The observed plastic hinge lengths (Lp) were determined based on the height of observed the crush as of the foundation top level in the concrete shear wall model. The relationship between the findings of this study and empirical formulas in the literature was determined. It was determined that there is greater closeness between the values obtained from empirical formulas in the literature and the observed plastic hinge length values. It was observed that the plastic hinge length generally increases as the shear span increases. It was observed that the change in ρsh was not a very effective parameter in plastic hinge formation. As the N/No decreases, the plastic hinge length values generally increase. The Lp/Lpz ratio varied within the range of 0.15-0.50. In addition to ductility (μ) values were determined by using the displacements determined according to both the crushing occurred in the shear wall concrete and the yield observed in the steel reinforcement. The observed that the ductility value depends more on Hw/Lw ratio as N/No ratio decreases.
- 1 August 2024
- Published by Pontificia Universidad Catolica de Chile
- Vol. 23 (2) , 177-202
Open AccessInvestigation of plastic hinge length in high-ductility reinforced concrete shear walls
In this study, the plastic hinge lengths of reinforced concrete (R/C) cantilever shear walls were analytically determined considering various design parameters. Nonlinear static (Pushover) analyses were conducted on R/C shear wall models and their nonlinear behavior was examined using ABAQUS software. In the study, 72 shear wall models with different parameters were analyzed under the influence of vertical and horizontal loads. Parameters whose effects on plastic hinge length were investigated height/length ratio (Hw/Lw), axial load ratio (N/No), and horizontal web reinforcement ratio (ρsh). The load-displacement graphs of the modelled shear walls were obtained. The plastic hinge height of shear walls was determined according to the heights of the deformations in the concrete and longitudinal steel reinforcement in the section when the shear walls lateral load decreased by 15%. The analytical plastic hinge lengths (Lpz) were determined with respect to the location of the yield occurred at the longitudinal steel reinforcement of the shear wall. The observed plastic hinge lengths (Lp) were determined based on the height of observed the crush as of the foundation top level in the concrete shear wall model. The relationship between the findings of this study and empirical formulas in the literature was determined. It was determined that there is greater closeness between the values obtained from empirical formulas in the literature and the observed plastic hinge length values. It was observed that the plastic hinge length generally increases as the shear span increases. It was observed that the change in ρsh was not a very effective parameter in plastic hinge formation. As the N/No decreases, the plastic hinge length values generally increase. The Lp/Lpz ratio varied within the range of 0.15-0.50. In addition to ductility (μ) values were determined by using the displacements determined according to both the crushing occurred in the shear wall concrete and the yield observed in the steel reinforcement. The observed that the ductility value depends more on Hw/Lw ratio as N/No ratio decreases.
- Open Access
- 12 December 2023
- Published by Konya Muhendislik Bilimleri Dergisi in Konya Journal of Engineering Sciences
- Vol. 12 (1) , 22-36
FAILURE ANALYSIS OF A BASE SUPPORT PLATE OF A SEMOLINA PURIFIER MACHINES SUBJECTED TO FATIGUE LOADING
The semolina purifier is a machine used in the production phase in flour factories and is exposed to fatigue loads. In this study, the reason for the damage when a semolina purifier machine breaks during use and the improvements that need to be made in the design are discussed. For this purpose, a finite element model (FEM) was created using ABAQUS software. As a result of the analysis, it was determined that the design of the machine support platform should be improved. A two-stage strengthening alternative is designed. The cyclic loads applied by the twin motors that move the machine screens are applied in the FEM model. The deformations and stresses occurring in the reinforced and existing design machine base plate were compared. The results showed that, the maximum equivalent stress level can be reduced from 86 MPa to 35 MPa by design improvements made on the base plate.
- 12 December 2023
- Published by Konya Muhendislik Bilimleri Dergisi in Konya Journal of Engineering Sciences
- Vol. 12 (1) , 22-36
Open AccessFAILURE ANALYSIS OF A BASE SUPPORT PLATE OF A SEMOLINA PURIFIER MACHINES SUBJECTED TO FATIGUE LOADING
The semolina purifier is a machine used in the production phase in flour factories and is exposed to fatigue loads. In this study, the reason for the damage when a semolina purifier machine breaks during use and the improvements that need to be made in the design are discussed. For this purpose, a finite element model (FEM) was created using ABAQUS software. As a result of the analysis, it was determined that the design of the machine support platform should be improved. A two-stage strengthening alternative is designed. The cyclic loads applied by the twin motors that move the machine screens are applied in the FEM model. The deformations and stresses occurring in the reinforced and existing design machine base plate were compared. The results showed that, the maximum equivalent stress level can be reduced from 86 MPa to 35 MPa by design improvements made on the base plate.
- 20 September 2023
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 27 (13) , 1768-1780
Do lateral ankle ligaments contribute to syndesmotic stability: a finite element analysis study
Whether the lateral ankle ligaments contribute to syndesmotic stability is still controversial and has been the subject of frequent research recently. In our study, we tried to elucidate this situation using the finite element analysis method. Intact model and thirteen different injury models were created to simulate injuries of the lateral ankle ligaments (ATFL, CFL, PTFL), injuries of the syndesmotic ligaments (AITFL, IOL, PITFL) and their combined injuries. The models were compared in terms of LFT, PFT and EFR. It was observed that 0.537 mm LFT, 0.626 mm PFT and 1.25° EFR occurred in the intact model (M#1), 0.539 mm LFT, 0.761 mm PFT and 2.31° EFR occurred in the isolated ATFL injury (M#2), 0.547 mm LFT, 0.791 mm PFT and 2.50° EFR occurred in the isolated AITFL injury (M#8). The LFT, PFT and EFR amounts were higher in the both M#2 and M#8 compared to the M#1. LFT, PFT and EFR amounts in M#2 and M#8 were found to be extremely close. In terms of LFT and PFT, when we compare models with (LFT: 0.650 mm, PFT: 1.104) and without (LFT: 0.457 mm, PFT: 1.150) IOL injury, it is seen that the amount of LFT increases and the amount of PFT decreases with IOL injury. We also observed that injuries to the CFL, PTFL and PITFL did not cause significant changes in fibular translations and PFT and EFR values show an almost linear correlation. Our results suggest that ATFL injury plays a crucial role in syndesmotic stability.
- 20 September 2023
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 27 (13) , 1768-1780
Do lateral ankle ligaments contribute to syndesmotic stability: a finite element analysis study
Whether the lateral ankle ligaments contribute to syndesmotic stability is still controversial and has been the subject of frequent research recently. In our study, we tried to elucidate this situation using the finite element analysis method. Intact model and thirteen different injury models were created to simulate injuries of the lateral ankle ligaments (ATFL, CFL, PTFL), injuries of the syndesmotic ligaments (AITFL, IOL, PITFL) and their combined injuries. The models were compared in terms of LFT, PFT and EFR. It was observed that 0.537 mm LFT, 0.626 mm PFT and 1.25° EFR occurred in the intact model (M#1), 0.539 mm LFT, 0.761 mm PFT and 2.31° EFR occurred in the isolated ATFL injury (M#2), 0.547 mm LFT, 0.791 mm PFT and 2.50° EFR occurred in the isolated AITFL injury (M#8). The LFT, PFT and EFR amounts were higher in the both M#2 and M#8 compared to the M#1. LFT, PFT and EFR amounts in M#2 and M#8 were found to be extremely close. In terms of LFT and PFT, when we compare models with (LFT: 0.650 mm, PFT: 1.104) and without (LFT: 0.457 mm, PFT: 1.150) IOL injury, it is seen that the amount of LFT increases and the amount of PFT decreases with IOL injury. We also observed that injuries to the CFL, PTFL and PITFL did not cause significant changes in fibular translations and PFT and EFR values show an almost linear correlation. Our results suggest that ATFL injury plays a crucial role in syndesmotic stability.
- 1 April 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 31 (2)
Assessing a Retrofitting Method for Existing RC Buildings with Low Seismic Capacity in Turkey
In this research, external retrofit of reinforced concrete (RC) buildings, especially the ones located in Turkey, was studied. Most of Turkey’s population live in an active seismic zone where frequent earthquakes are experienced. Turkey’s existing residential building stock consists mainly of reinforced concrete buildings that are prone to earthquake damage because of a lack of lateral strength. Therefore, a fast and feasible shear retrofit method for these buildings is crucial. In this study, three six-story prototype RC buildings were created to study the effectiveness of external shear retrofit with and without the inclusion of window openings, constructed at building corners. As always desired, this retrofit method was shown to be fast to apply and its construction requires minor damage on the building. The three-dimensional (3D) finite-element model of the building was analyzed nonlinearly by a commercially available software package. The modeling of concrete material as well as embedded stee...
- 1 April 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 31 (2)
Assessing a Retrofitting Method for Existing RC Buildings with Low Seismic Capacity in Turkey
In this research, external retrofit of reinforced concrete (RC) buildings, especially the ones located in Turkey, was studied. Most of Turkey’s population live in an active seismic zone where frequent earthquakes are experienced. Turkey’s existing residential building stock consists mainly of reinforced concrete buildings that are prone to earthquake damage because of a lack of lateral strength. Therefore, a fast and feasible shear retrofit method for these buildings is crucial. In this study, three six-story prototype RC buildings were created to study the effectiveness of external shear retrofit with and without the inclusion of window openings, constructed at building corners. As always desired, this retrofit method was shown to be fast to apply and its construction requires minor damage on the building. The three-dimensional (3D) finite-element model of the building was analyzed nonlinearly by a commercially available software package. The modeling of concrete material as well as embedded stee...
- 1 September 2016
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 708, 64-69
Reinforcing Fibre Reinforced Polymer Bridge Decks with Steel Rods
Fibre reinforced polymer (FRP) bridge decks have become an innovative alternative and they have offered many advantages and this has been increasing attention for applications in not only reinforcement of existing bridges decks but also construction of new bridges decks. The advantages of these FRP decks are; lightweight, high-strength FRP materials, corrosion resistance. However, this high strength deck is not ductile. In this study, the behaviour of hybrid FRP-steel decks are investigated. All FRP decks was analysed with the commercial package ABAQUS. In the FE model, the webs and flanges were discretised by 4 nodes shell elements. A full composite action between the steel and the FRP composite was assumed in the FE analysis because the bond-slip behaviour was unknown at that time. The performance of the proposed hybrid FRP deck panel was evaluated by means of FE analysis.
- 1 September 2016
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 708, 64-69
Reinforcing Fibre Reinforced Polymer Bridge Decks with Steel Rods
Fibre reinforced polymer (FRP) bridge decks have become an innovative alternative and they have offered many advantages and this has been increasing attention for applications in not only reinforcement of existing bridges decks but also construction of new bridges decks. The advantages of these FRP decks are; lightweight, high-strength FRP materials, corrosion resistance. However, this high strength deck is not ductile. In this study, the behaviour of hybrid FRP-steel decks are investigated. All FRP decks was analysed with the commercial package ABAQUS. In the FE model, the webs and flanges were discretised by 4 nodes shell elements. A full composite action between the steel and the FRP composite was assumed in the FE analysis because the bond-slip behaviour was unknown at that time. The performance of the proposed hybrid FRP deck panel was evaluated by means of FE analysis.
- 1 July 2016
- Published by Elsevier in Measurement
- Vol. 89, 48-54
Effectiveness of the floating slab track system constructed at Konya Light Rail
- 1 July 2016
- Published by Elsevier in Measurement
- Vol. 89, 48-54
Effectiveness of the floating slab track system constructed at Konya Light Rail
- Open Access
- 1 December 2011
- Published by MDPI AG in Mathematical and Computational Applications
- Vol. 16 (4) , 947-958
Nonlinear Finite Element Analysis of an R/C Frame Under Lateral Loading
Recent developments in computer technology have made possible the use of finite element methods for 3D modeling and analysis of reinforced concrete structures. In this study, the failure behavior and crack formation of an R/C frame under monotonic and reversed-cyclic lateral loading are studied by 3D nonlinear finite element analysis using ANSYS software. Modeling the nonlinear behavior of concrete material as well as the reinforcing steel embedded within concrete is a difficult task. Different methodologies and modeling options are considered in the computer model. The application of reversed cyclic displacement loading and the execution of nonlinear analyses are explained in detail. Load-displacement relationships and concrete crack profiles are obtained in order to compare with the experimental data and observed crack profile. The analysis results compared well with the experimental data based on the comparison of load-displacement graphs. The failure mode of the frame is identified by the crack profiles displayed on the structure.
- 1 December 2011
- Published by MDPI AG in Mathematical and Computational Applications
- Vol. 16 (4) , 947-958
Open AccessNonlinear Finite Element Analysis of an R/C Frame Under Lateral Loading
Recent developments in computer technology have made possible the use of finite element methods for 3D modeling and analysis of reinforced concrete structures. In this study, the failure behavior and crack formation of an R/C frame under monotonic and reversed-cyclic lateral loading are studied by 3D nonlinear finite element analysis using ANSYS software. Modeling the nonlinear behavior of concrete material as well as the reinforcing steel embedded within concrete is a difficult task. Different methodologies and modeling options are considered in the computer model. The application of reversed cyclic displacement loading and the execution of nonlinear analyses are explained in detail. Load-displacement relationships and concrete crack profiles are obtained in order to compare with the experimental data and observed crack profile. The analysis results compared well with the experimental data based on the comparison of load-displacement graphs. The failure mode of the frame is identified by the crack profiles displayed on the structure.