Linda Iorizzo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Linda Iorizzo has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Nana Wiberg
Department of Clinical Sciences Malmö Lund University Lund Sweden
4 shared publications Karl Kristensen
Gold Coast University Hospital
2 shared publicationsNana Wiberg
Lund University Faculty of Medicine
2 shared publicationsPer-Erik Isberg
Lund University
2 shared publicationsA. Herbst
Department of Clinical Sciences Lund Lund University Lund Sweden
1 shared publicationAlexandra Tidstedt
Department of Obstetrics and Gynecology Höglandssjukhuset Eksjö Sweden
1 shared publication
Latest Publications
- Open Access
- 26 October 2025
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 104 (12) , 2273-2281
Validation and proposal of a clinical intervention cutoff in fetal scalp blood for the point‐of care‐lactate meter StatStrip ® 2
Introduction: This multicenter, prospective observational study aimed to evaluate the performance of the StatStrip ® Lactate 2 (Nova Biomedical, Waltham, US) point‐of‐care device for fetal blood lactate measurement and to determine the corresponding lactate value equivalent to the established intervention cutoff used with the outgoing StatStrip ® Lactate device. Material and Methods: The study was conducted from August 2024 to February 2025 at two maternity clinics in Sweden and one in Denmark. It included women with singleton pregnancies (≥35 + 0 weeks) undergoing fetal blood sampling due to non‐reassuring intrapartal fetal heart rate patterns during labor. Fetal scalp blood sampling (FBS) lactate concentrations were measured using both StatStrip ® Lactate and StatStrip ® Lactate2. The first StatStrip ® Lactate measurement guided clinical decisions, while subsequent StatStrip ® Lactate2 measurements were recorded for validation and establishment of a conversion equation by linear regression. Additionally, arterial and venous umbilical cord blood samples were analyzed by both ABL 800 (Radiometer, Denmark) and StatStrip ® Lactate2 for validation. Results: Blood samples from 349 fetuses were included, with 549 parallel FBS lactate samples. StatStrip ® Lactate2 concentrations correlated with StatStrip ® Lactate ( r = 0.94; p ≤ 0.001). A conversion equation was retrieved: StatStrip ® Lactate2 = (1.4 × StatStrip ® Lactate) − 0.28. From 37 paired umbilical cord blood samples, the correlation between lactate concentrations by StatStrip ® Lactate2 and ABL800 was r = 0.99 ( p ≤ 0.001) in arterial blood and r = 0.98 ( p ≤ 0.001) in venous blood. Mean coefficients of variation for lactate concentrations >3.0 mmol/L were 8.2% in fetal scalp blood and 3.8% in umbilical cord blood. Conclusions: A fetal blood lactate concentration ≥7.0 mmol/L measured by StatStrip ® Lactate2 corresponds to the established intervention cutoff lactate value ≥5.2 mmol/L measured by StatStrip ® Lactate. Precision was acceptable but may be improved by using the mean of two measurements, particularly when the first result falls between 6.0 and 8.0 mmol/L. We also recommend ensuring the correct sampling techniques to minimize preanalytical variation.
- 26 October 2025
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 104 (12) , 2273-2281
Open AccessValidation and proposal of a clinical intervention cutoff in fetal scalp blood for the point‐of care‐lactate meter StatStrip ® 2
Introduction: This multicenter, prospective observational study aimed to evaluate the performance of the StatStrip ® Lactate 2 (Nova Biomedical, Waltham, US) point‐of‐care device for fetal blood lactate measurement and to determine the corresponding lactate value equivalent to the established intervention cutoff used with the outgoing StatStrip ® Lactate device. Material and Methods: The study was conducted from August 2024 to February 2025 at two maternity clinics in Sweden and one in Denmark. It included women with singleton pregnancies (≥35 + 0 weeks) undergoing fetal blood sampling due to non‐reassuring intrapartal fetal heart rate patterns during labor. Fetal scalp blood sampling (FBS) lactate concentrations were measured using both StatStrip ® Lactate and StatStrip ® Lactate2. The first StatStrip ® Lactate measurement guided clinical decisions, while subsequent StatStrip ® Lactate2 measurements were recorded for validation and establishment of a conversion equation by linear regression. Additionally, arterial and venous umbilical cord blood samples were analyzed by both ABL 800 (Radiometer, Denmark) and StatStrip ® Lactate2 for validation. Results: Blood samples from 349 fetuses were included, with 549 parallel FBS lactate samples. StatStrip ® Lactate2 concentrations correlated with StatStrip ® Lactate ( r = 0.94; p ≤ 0.001). A conversion equation was retrieved: StatStrip ® Lactate2 = (1.4 × StatStrip ® Lactate) − 0.28. From 37 paired umbilical cord blood samples, the correlation between lactate concentrations by StatStrip ® Lactate2 and ABL800 was r = 0.99 ( p ≤ 0.001) in arterial blood and r = 0.98 ( p ≤ 0.001) in venous blood. Mean coefficients of variation for lactate concentrations >3.0 mmol/L were 8.2% in fetal scalp blood and 3.8% in umbilical cord blood. Conclusions: A fetal blood lactate concentration ≥7.0 mmol/L measured by StatStrip ® Lactate2 corresponds to the established intervention cutoff lactate value ≥5.2 mmol/L measured by StatStrip ® Lactate. Precision was acceptable but may be improved by using the mean of two measurements, particularly when the first result falls between 6.0 and 8.0 mmol/L. We also recommend ensuring the correct sampling techniques to minimize preanalytical variation.
- Open Access
- 8 August 2025
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 25 (1) , 825
Influence of the active second stage of labor in nulliparous women on umbilical cord blood pH and neonatal outcomes: a population-based, cohort study
Background: Prolonged second stage of labor increases the risk of insufficient gas exchange over the placenta to the fetus and risk of birth asphyxia. There are considerable variations in clinical guidelines regarding the recommended duration of pushing during the active second stage of labor. Thus, the aim of this study was to investigate the total duration of the second stage of labor and its association to changes in umbilical cord pH and adverse neonatal outcomes in nulliparous women. Methods: This retrospective, multi-center cohort study was based on data from the Perinatal Revision South Register covering seven maternity units from 1995 to 2015. Nulliparous women with fetuses in cephalic position and complete and validated cord blood pH data were recruited to the study. Logistic regression was used to establish the relationship of duration of pushing, categorized in 60 min increments, with cord blood acidosis (umbilical cord arterial pH < 7.05) and adverse neonatal outcomes, including Apgar score at 5 min, risk for central nervous system (CNS) disease, utilization of continuous positive airway pressure (CPAP), neonatal intensive care unit (NICU) admission and hypoxic ischemic encephalopathy (HIE). The adjusted model adjusted for maternal BMI, gestational duration and birth weight. Results: A total of 37,008 women were included in the analysis. For every 60 min increase in pushing time, there was a significantly increased adjusted odds ratio (aOR) for umbilical arterial pH < 7.05, aOR = 1.639, (95% CI = 1.418–1.895, P = 0.02), Apgar score < 7 at 5-minutes, aOR = 1.408 (95% CI = 1.082–1.831, P = 0.01), and prevalence of suspected CNS disease, aOR = 1.417, (95% CI = 1.065–1.886, P = 0.02). The use of CPAP, (aOR = 1.215, 95% CI = 0.945–1.561, P = 0.13), NICU admission (aOR = 1.021, 95% CI = 0.890–1.171, P = 0.77), neonatal seizures (aOR = 0.000, P = 0.98) and HIE (aOR = 1.377, 95% CI = 0.416–4.109, P = 0.57) were not associated with increased pushing time. Conclusions: Using a large, population-based cohort, we found that prolonged active second stage of labor was associated with an increased odds for cord blood acidosis at birth, low Apgar score at 5 min, and suspected CNS-disease in neonates. Efficient and evidence-based time management during the active second stage of labor is therefore crucial for reducing the risk of adverse neonatal outcomes.
- 8 August 2025
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 25 (1) , 825
Open AccessInfluence of the active second stage of labor in nulliparous women on umbilical cord blood pH and neonatal outcomes: a population-based, cohort study
Background: Prolonged second stage of labor increases the risk of insufficient gas exchange over the placenta to the fetus and risk of birth asphyxia. There are considerable variations in clinical guidelines regarding the recommended duration of pushing during the active second stage of labor. Thus, the aim of this study was to investigate the total duration of the second stage of labor and its association to changes in umbilical cord pH and adverse neonatal outcomes in nulliparous women. Methods: This retrospective, multi-center cohort study was based on data from the Perinatal Revision South Register covering seven maternity units from 1995 to 2015. Nulliparous women with fetuses in cephalic position and complete and validated cord blood pH data were recruited to the study. Logistic regression was used to establish the relationship of duration of pushing, categorized in 60 min increments, with cord blood acidosis (umbilical cord arterial pH < 7.05) and adverse neonatal outcomes, including Apgar score at 5 min, risk for central nervous system (CNS) disease, utilization of continuous positive airway pressure (CPAP), neonatal intensive care unit (NICU) admission and hypoxic ischemic encephalopathy (HIE). The adjusted model adjusted for maternal BMI, gestational duration and birth weight. Results: A total of 37,008 women were included in the analysis. For every 60 min increase in pushing time, there was a significantly increased adjusted odds ratio (aOR) for umbilical arterial pH < 7.05, aOR = 1.639, (95% CI = 1.418–1.895, P = 0.02), Apgar score < 7 at 5-minutes, aOR = 1.408 (95% CI = 1.082–1.831, P = 0.01), and prevalence of suspected CNS disease, aOR = 1.417, (95% CI = 1.065–1.886, P = 0.02). The use of CPAP, (aOR = 1.215, 95% CI = 0.945–1.561, P = 0.13), NICU admission (aOR = 1.021, 95% CI = 0.890–1.171, P = 0.77), neonatal seizures (aOR = 0.000, P = 0.98) and HIE (aOR = 1.377, 95% CI = 0.416–4.109, P = 0.57) were not associated with increased pushing time. Conclusions: Using a large, population-based cohort, we found that prolonged active second stage of labor was associated with an increased odds for cord blood acidosis at birth, low Apgar score at 5 min, and suspected CNS-disease in neonates. Efficient and evidence-based time management during the active second stage of labor is therefore crucial for reducing the risk of adverse neonatal outcomes.
- Open Access
- 22 April 2022
- Published by Wiley in BJOG: An International Journal of Obstetrics & Gynaecology
- Vol. 129 (8) , 1361-1374
Clinical‐pathological features in placentas of pregnancies with SARS‐CoV‐2 infection and adverse outcome: case series with and without congenital transmission
Objective: To correlate clinical outcomes to pathology in SARS‐CoV‐2 infected placentas in stillborn and live‐born infants presenting with fetal distress.Design: Retrospective, observational.Setting: Nationwide.Population: Five stillborn and nine live‐born infants from 13 pregnant women infected with SARS‐CoV‐2 seeking care at seven different maternity units in Sweden.Methods: Clinical outcomes and placental pathology were studied in 14 cases (one twin pregnancy) of maternal SARS‐CoV‐2 infection with impaired fetal outcome. Outcomes were correlated to placental pathology in order to investigate the impact of virus‐related pathology on the villous capillary endothelium, trophoblast and other cells.Main outcome measures: Maternal and fetal clinical outcomes and placental pathology in stillborn and live‐born infants.Results: Reduced fetal movements were reported (77%) and time from onset of maternal COVID‐19 symptoms to signs of fetal distress among live‐born infants was 6 (3–12) days and to diagnosis of stillbirth 11 (2–25) days. Two of the live‐born infants died during the postnatal period. Signs of fetal distress led to emergency caesarean section in all live‐born infants with umbilical cord blood gases and low Apgar scores confirming intrauterine hypoxia. Five stillborn and one live‐born neonate had confirmed congenital transmission. Massive perivillous fibrinoid deposition, intervillositis and trophoblast necrosis were associated with SARS‐CoV‐2 placental infection and congenital transmission.Conclusions: SARS‐CoV‐2 can cause rapid placental dysfunction with subsequent acute fetal hypoxia leading to intrauterine fetal compromise. Associated placental pathology included massive perivillous fibrinoid deposition, intervillositis and trophoblast degeneration.
- 22 April 2022
- Published by Wiley in BJOG: An International Journal of Obstetrics & Gynaecology
- Vol. 129 (8) , 1361-1374
Open AccessClinical‐pathological features in placentas of pregnancies with SARS‐CoV‐2 infection and adverse outcome: case series with and without congenital transmission
Objective: To correlate clinical outcomes to pathology in SARS‐CoV‐2 infected placentas in stillborn and live‐born infants presenting with fetal distress.Design: Retrospective, observational.Setting: Nationwide.Population: Five stillborn and nine live‐born infants from 13 pregnant women infected with SARS‐CoV‐2 seeking care at seven different maternity units in Sweden.Methods: Clinical outcomes and placental pathology were studied in 14 cases (one twin pregnancy) of maternal SARS‐CoV‐2 infection with impaired fetal outcome. Outcomes were correlated to placental pathology in order to investigate the impact of virus‐related pathology on the villous capillary endothelium, trophoblast and other cells.Main outcome measures: Maternal and fetal clinical outcomes and placental pathology in stillborn and live‐born infants.Results: Reduced fetal movements were reported (77%) and time from onset of maternal COVID‐19 symptoms to signs of fetal distress among live‐born infants was 6 (3–12) days and to diagnosis of stillbirth 11 (2–25) days. Two of the live‐born infants died during the postnatal period. Signs of fetal distress led to emergency caesarean section in all live‐born infants with umbilical cord blood gases and low Apgar scores confirming intrauterine hypoxia. Five stillborn and one live‐born neonate had confirmed congenital transmission. Massive perivillous fibrinoid deposition, intervillositis and trophoblast necrosis were associated with SARS‐CoV‐2 placental infection and congenital transmission.Conclusions: SARS‐CoV‐2 can cause rapid placental dysfunction with subsequent acute fetal hypoxia leading to intrauterine fetal compromise. Associated placental pathology included massive perivillous fibrinoid deposition, intervillositis and trophoblast degeneration.
- Open Access
- 23 September 2021
- Published by Wiley in BJOG: An International Journal of Obstetrics & Gynaecology
- Vol. 129 (4) , 636-646
Proposed cutoff for fetal scalp blood lactate in intrapartum fetal surveillance based on neonatal outcomes: a large prospective observational study
Objective: Determination of lactate in fetal scalp blood (FBS) during labour has been recognised since the 1970s. The internationally accepted cutoff of >4.8 mmol/l indicating fetal acidosis is exclusive for the point‐of‐care device (POC) LactatePro™, which is no longer in production. The aim of this study was to establish a new cutoff for scalp lactate based on neonatal outcomes with the use of the StatstripLactate®/StatstripXpress® Lactate system, the only POC designed for hospital use.Design: Observational study.Setting: January 2016 to March 2020 labouring women with indication for FBS were prospectively included from seven Swedish and one Australian delivery unit.Population: Inclusion criteria: singleton pregnancy, vertex presentation, ≥35+0 weeks of gestation.Method: Based on the optimal correlation between FBS lactate and cord pH/lactate, only cases with ≤25 minutes from FBS to delivery were included in the final calculations.Main outcome measures: Metabolic acidosis in cord blood defined as pH 10 mmol/l and/or lactate >10 mmol/l.Results: A total of 3334 women were enrolled of whom 799 were delivered within 25 minutes. The areas under the receiver operating characteristics curves (AUC) and corresponding optimal cutoff values were as follows; metabolic acidosis AUC 0.87 (95% CI 0.77–0.97), cutoff 5.7 mmol/l; pH ecf ≥12 mmol/l AUC 0.97 (95% CI 0.92–1), cutoff 5.8 mmol/l; Apgar score ®/StatstripXpress® system will safely rule out fetal metabolic acidosis.Tweetable Scalp blood lactate ®/StatstripXpress system has an excellent ability to rule out fetal acidosis.
- 23 September 2021
- Published by Wiley in BJOG: An International Journal of Obstetrics & Gynaecology
- Vol. 129 (4) , 636-646
Open AccessProposed cutoff for fetal scalp blood lactate in intrapartum fetal surveillance based on neonatal outcomes: a large prospective observational study
Objective: Determination of lactate in fetal scalp blood (FBS) during labour has been recognised since the 1970s. The internationally accepted cutoff of >4.8 mmol/l indicating fetal acidosis is exclusive for the point‐of‐care device (POC) LactatePro™, which is no longer in production. The aim of this study was to establish a new cutoff for scalp lactate based on neonatal outcomes with the use of the StatstripLactate®/StatstripXpress® Lactate system, the only POC designed for hospital use.Design: Observational study.Setting: January 2016 to March 2020 labouring women with indication for FBS were prospectively included from seven Swedish and one Australian delivery unit.Population: Inclusion criteria: singleton pregnancy, vertex presentation, ≥35+0 weeks of gestation.Method: Based on the optimal correlation between FBS lactate and cord pH/lactate, only cases with ≤25 minutes from FBS to delivery were included in the final calculations.Main outcome measures: Metabolic acidosis in cord blood defined as pH 10 mmol/l and/or lactate >10 mmol/l.Results: A total of 3334 women were enrolled of whom 799 were delivered within 25 minutes. The areas under the receiver operating characteristics curves (AUC) and corresponding optimal cutoff values were as follows; metabolic acidosis AUC 0.87 (95% CI 0.77–0.97), cutoff 5.7 mmol/l; pH ecf ≥12 mmol/l AUC 0.97 (95% CI 0.92–1), cutoff 5.8 mmol/l; Apgar score ®/StatstripXpress® system will safely rule out fetal metabolic acidosis.Tweetable Scalp blood lactate ®/StatstripXpress system has an excellent ability to rule out fetal acidosis.
- Open Access
- 12 March 2021
- Published by Wiley
Proposed cut-off for fetal scalp blood lactate in intrapartum fetal surveillance based on neonatal outcomes: a prospective observational study
Objective Determination of lactate in fetal scalp blood (FBS) during labor has been studied since the 1970s. The internationally accepted cut-off of >4.8mmol/L indicating fetal acidaemia is exclusive for the point-of-care device (POC) LactateProTM, which is no longer in production. The aim of this study was to present a new cut-off for scalp lactate based on neonatal outcomes with the use of StatstripLactate®/StatstripXpress® Lactate system, the only POC lactate meter designed for hospital use. Design Observational Study Setting January 2016 to March 2020 labouring women with an indication for FBS were prospectively included from seven Swedish and one Australian delivery unit. Population Inclusion criteria: singleton pregnancy, vertex presentation, ≥35+0 gestational weeks. Method Based on the optimal correlation between FBS lactate and cord pH/lactate, only cases with ≤25 minutes from FBS to delivery were included in the final calculations. Main outcome measures Metabolic acidosis in cord blood was defined as pH 10 mmol/L and/or lactate >10 mmol/L. Results 3334 women were enrolled of which 799 were delivered within 25 minutes. The areas under the ROC curves (AUC) and corresponding optimal lactate cut-off values were as follows; metabolic acidosis AUC 0.87(95% CI:0.77-0.97), cut-off 5.7mmol/L; pH <7.0 AUC 0.83(95% CI:0.68-0.97), cut-off 4.6mmol/L; pH <7.05 plus BD ≥12mmol/L AUC 0.97(95% CI:0.92-1), cut-off 5.8mmol/L; Apgar score <7 at 5 minutes AUC 0.74(95% CI:0.63-0.86), cut-off 5.2mmol/L; and pH <7.10 plus composite neonatal outcome AUC 0.76(95% CI:0.67-0.85), cut-off 4.8mmol/L. Conclusions Suggested intervention threshold for fetal acidemia is scalp lactate of 5.2mmol/L using the StatstripLactate®/StatstripXpress®.
- 12 March 2021
- Published by Wiley
Open AccessProposed cut-off for fetal scalp blood lactate in intrapartum fetal surveillance based on neonatal outcomes: a prospective observational study
Objective Determination of lactate in fetal scalp blood (FBS) during labor has been studied since the 1970s. The internationally accepted cut-off of >4.8mmol/L indicating fetal acidaemia is exclusive for the point-of-care device (POC) LactateProTM, which is no longer in production. The aim of this study was to present a new cut-off for scalp lactate based on neonatal outcomes with the use of StatstripLactate®/StatstripXpress® Lactate system, the only POC lactate meter designed for hospital use. Design Observational Study Setting January 2016 to March 2020 labouring women with an indication for FBS were prospectively included from seven Swedish and one Australian delivery unit. Population Inclusion criteria: singleton pregnancy, vertex presentation, ≥35+0 gestational weeks. Method Based on the optimal correlation between FBS lactate and cord pH/lactate, only cases with ≤25 minutes from FBS to delivery were included in the final calculations. Main outcome measures Metabolic acidosis in cord blood was defined as pH 10 mmol/L and/or lactate >10 mmol/L. Results 3334 women were enrolled of which 799 were delivered within 25 minutes. The areas under the ROC curves (AUC) and corresponding optimal lactate cut-off values were as follows; metabolic acidosis AUC 0.87(95% CI:0.77-0.97), cut-off 5.7mmol/L; pH <7.0 AUC 0.83(95% CI:0.68-0.97), cut-off 4.6mmol/L; pH <7.05 plus BD ≥12mmol/L AUC 0.97(95% CI:0.92-1), cut-off 5.8mmol/L; Apgar score <7 at 5 minutes AUC 0.74(95% CI:0.63-0.86), cut-off 5.2mmol/L; and pH <7.10 plus composite neonatal outcome AUC 0.76(95% CI:0.67-0.85), cut-off 4.8mmol/L. Conclusions Suggested intervention threshold for fetal acidemia is scalp lactate of 5.2mmol/L using the StatstripLactate®/StatstripXpress®.
- Open Access
- 5 June 2020
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 20 (1) , 1-7
Effectiveness of fetal scalp stimulation test in assessing fetal wellbeing during labor, a retrospective cohort study
Background: It is discussed whether fetal scalp stimulation (FSS) test is a reliable complimentary tool to cardiotocography (CTG) to assess fetal wellbeing during labor. The test is based on the assumption that a well-oxygenated fetus, in contrast to the depressed fetus, will respond to a certain stimulus. The aim of this study was to investigate the effectiveness of the FSS-test. Methods: A retrospective observational study carried out Copenhagen University Hospital, Herlev, Denmark. Laboring women with singleton pregnancies in cephalic presentation after gestation week 33 and indication for fetal blood sampling (FBS) were eligible for inclusion. The FSS-test was classified as positive when an acceleration was absent at the time of FBS and negative when an acceleration was present. Lactate in scalp blood was measured by the point-of-care device LactatePro™ and pH in artery umbilical cord blood by the stationary blood gas analyzer ABL800. Lactate level < 4.2 mmol/L in scalp blood and arterial cord pH > 7.1 were cut-offs for normality. Results: Three hundred eighty-five women were included. The cohort was divided by the FBS-to-delivery time: Group 1 (n = 128) ≤ 20 min, Group 2 (n = 117) 21–59 min and Group 3 (n = 140) ≥ 60 min. The proportion of FSS-positive tests differed significantly between the groups (p < 0.000). In Group 1 the sensitivity, specificity and likelihoods for scalp lactate ≥4.2 mmol/L were 81.5 (95% CI 67–90.1), 13.3 18.5 (95% CI 5.9–24.6), LHR+ 0.94 (95% CI 0.8–1.1) and LHR – 1.4 (95% CI 0.6–3.2) and for umbilical artery pH ≤ 7.10 the values were 82.6% (95% CI 61.2–95.1), 16% (95% CI 9.4–24.7), 1.0 (95% CI 0.8–1.2) and 1.1 (95% CI 0.4–3) respectively. Regardless of the FBS-to-delivery time the LHR+ for lactate ≥4.2 mmol/L increased to 1.38 (95% CI 1.2–1.6). Conclusion: The effectiveness of scalp stimulation test was poor for both ruling in and out fetal hypoxia during labor. Absence of a provoked acceleration seems to be a normal phenomenon in the second stage of labor.
- 5 June 2020
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 20 (1) , 1-7
Open AccessEffectiveness of fetal scalp stimulation test in assessing fetal wellbeing during labor, a retrospective cohort study
Background: It is discussed whether fetal scalp stimulation (FSS) test is a reliable complimentary tool to cardiotocography (CTG) to assess fetal wellbeing during labor. The test is based on the assumption that a well-oxygenated fetus, in contrast to the depressed fetus, will respond to a certain stimulus. The aim of this study was to investigate the effectiveness of the FSS-test. Methods: A retrospective observational study carried out Copenhagen University Hospital, Herlev, Denmark. Laboring women with singleton pregnancies in cephalic presentation after gestation week 33 and indication for fetal blood sampling (FBS) were eligible for inclusion. The FSS-test was classified as positive when an acceleration was absent at the time of FBS and negative when an acceleration was present. Lactate in scalp blood was measured by the point-of-care device LactatePro™ and pH in artery umbilical cord blood by the stationary blood gas analyzer ABL800. Lactate level < 4.2 mmol/L in scalp blood and arterial cord pH > 7.1 were cut-offs for normality. Results: Three hundred eighty-five women were included. The cohort was divided by the FBS-to-delivery time: Group 1 (n = 128) ≤ 20 min, Group 2 (n = 117) 21–59 min and Group 3 (n = 140) ≥ 60 min. The proportion of FSS-positive tests differed significantly between the groups (p < 0.000). In Group 1 the sensitivity, specificity and likelihoods for scalp lactate ≥4.2 mmol/L were 81.5 (95% CI 67–90.1), 13.3 18.5 (95% CI 5.9–24.6), LHR+ 0.94 (95% CI 0.8–1.1) and LHR – 1.4 (95% CI 0.6–3.2) and for umbilical artery pH ≤ 7.10 the values were 82.6% (95% CI 61.2–95.1), 16% (95% CI 9.4–24.7), 1.0 (95% CI 0.8–1.2) and 1.1 (95% CI 0.4–3) respectively. Regardless of the FBS-to-delivery time the LHR+ for lactate ≥4.2 mmol/L increased to 1.38 (95% CI 1.2–1.6). Conclusion: The effectiveness of scalp stimulation test was poor for both ruling in and out fetal hypoxia during labor. Absence of a provoked acceleration seems to be a normal phenomenon in the second stage of labor.
- 1 August 2019
- Published by Elsevier in Clinica Chimica Acta
- Vol. 495, 88-93
Reliability of the point-of care analyzer “StatStrip® Xpress™” for measurement of fetal blood lactate
- 1 August 2019
- Published by Elsevier in Clinica Chimica Acta
- Vol. 495, 88-93
Reliability of the point-of care analyzer “StatStrip® Xpress™” for measurement of fetal blood lactate
- 4 January 2018
- Published by Taylor & Francis in The Journal of Maternal-Fetal & Neonatal Medicine
- Vol. 32 (11) , 1762-1768
Use of Lactate Pro TM 2 for measurement of fetal scalp blood lactate during labor – proposing new cutoffs for normality, preacidemia and acidemia: a cross-sectional study
Objective: Measurement of fetal scalp blood lactate is a supplementary tool to cardiotocography in the case of a non-reassuring tracing. Several hand-held lactate meters have been launched, all with differentials in absolute values. Therefore, the reference intervals must be calculated for each device. The internationally accepted reference interval is based on measurement with Lactate ProTM with recently got out of production. The aim of this study was to propose cutoffs for normality, preacidemia, and acidemia in fetal scalp blood for Lactate ProTM2 based on the comparison of lactate values measured with Lactate ProTM and Lactate ProTM2. Design: Seven hundred one fetal scalp blood samples were analyzed simultaneously. The conversion equations were retrieved from the linear regression model. On the basis of the cutoffs for Lactate ProTM cutoffs for Lactate ProTM2 were calculated. Results: The conversion equations obtained were Lactate ProTM = −0.02 + 0.68 × Lactate ProTM2 (SD: −0.09–0.07 × Lactate ProTM2) and Lactate proTM2 (LP2) = 0.03 + 1.48 × Lactate ProTM (SD: 0.16 + 0.17 × Lactate ProTM). The correlation to umbilical arterial pH was identical for the two devices (r = −0.18), whereas the correlation to umbilical arterial lactate was better for Lactate ProTM than for Lactate ProTM2 (r = 0.38, respectively, r = 0.33). The correlation to umbilical arterial lactate was dependent on time from sampling to delivery. Conclusion: Proposed reference values for Lactate ProTM2: scalp lactate 7.1 mmol/L = acidemia, expedite delivery.
- 4 January 2018
- Published by Taylor & Francis in The Journal of Maternal-Fetal & Neonatal Medicine
- Vol. 32 (11) , 1762-1768
Use of Lactate Pro TM 2 for measurement of fetal scalp blood lactate during labor – proposing new cutoffs for normality, preacidemia and acidemia: a cross-sectional study
Objective: Measurement of fetal scalp blood lactate is a supplementary tool to cardiotocography in the case of a non-reassuring tracing. Several hand-held lactate meters have been launched, all with differentials in absolute values. Therefore, the reference intervals must be calculated for each device. The internationally accepted reference interval is based on measurement with Lactate ProTM with recently got out of production. The aim of this study was to propose cutoffs for normality, preacidemia, and acidemia in fetal scalp blood for Lactate ProTM2 based on the comparison of lactate values measured with Lactate ProTM and Lactate ProTM2. Design: Seven hundred one fetal scalp blood samples were analyzed simultaneously. The conversion equations were retrieved from the linear regression model. On the basis of the cutoffs for Lactate ProTM cutoffs for Lactate ProTM2 were calculated. Results: The conversion equations obtained were Lactate ProTM = −0.02 + 0.68 × Lactate ProTM2 (SD: −0.09–0.07 × Lactate ProTM2) and Lactate proTM2 (LP2) = 0.03 + 1.48 × Lactate ProTM (SD: 0.16 + 0.17 × Lactate ProTM). The correlation to umbilical arterial pH was identical for the two devices (r = −0.18), whereas the correlation to umbilical arterial lactate was better for Lactate ProTM than for Lactate ProTM2 (r = 0.38, respectively, r = 0.33). The correlation to umbilical arterial lactate was dependent on time from sampling to delivery. Conclusion: Proposed reference values for Lactate ProTM2: scalp lactate 7.1 mmol/L = acidemia, expedite delivery.
- 5 February 2011
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 90 (5) , 483-487
Validation of the Swedish short forms of the Pelvic Floor Impact Questionnaire (PFIQ-7), Pelvic Floor Distress Inventory (PFDI-20) and Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire (PISQ-12)
Objective. To psychometrically evaluate the Swedish translations of the short forms of the Pelvic Floor Impact Questionnaire (PFIQ‐7), Pelvic Floor Distress Inventory (PFDI‐20) and Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire (PISQ‐12). Design and Setting. Cross‐sectional design, University hospital. Sample. Forty‐four patients awaiting prolapse surgery. Methods. The dual‐panel translation method followed by an evaluation of validity and reliability in prolapse patients. Main Outcome Measures. Construct, convergent and discriminant validity, reliability via test–retest and internal consistency. Results. Item response rates were high (range 95.5–100%) for PFIQ‐7 and PFDI‐20. The corrected item–total correlations showed acceptable construct validity for PFIQ‐7 (r=0.338–0.826) but low for PFDI‐20 (r=0.116–0.581) and PISQ‐12 (r=0.024–0.735). Acceptable convergent validity was found in all three instruments, with a negative correlation with the SF‐12. There were no floor or ceiling effects in the three instruments. In the test–retest analysis, intraclass correlation coefficients were significant (r=0.888–0.943). Cronbach's α varied between 0.57 and 0.94. Conclusion. This is the first validated translation of the PFIQ‐7, PFDI‐20 and PISQ‐12 in Swedish. All three instruments indicated acceptable psychometric properties.
- 5 February 2011
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 90 (5) , 483-487
Validation of the Swedish short forms of the Pelvic Floor Impact Questionnaire (PFIQ-7), Pelvic Floor Distress Inventory (PFDI-20) and Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire (PISQ-12)
Objective. To psychometrically evaluate the Swedish translations of the short forms of the Pelvic Floor Impact Questionnaire (PFIQ‐7), Pelvic Floor Distress Inventory (PFDI‐20) and Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire (PISQ‐12). Design and Setting. Cross‐sectional design, University hospital. Sample. Forty‐four patients awaiting prolapse surgery. Methods. The dual‐panel translation method followed by an evaluation of validity and reliability in prolapse patients. Main Outcome Measures. Construct, convergent and discriminant validity, reliability via test–retest and internal consistency. Results. Item response rates were high (range 95.5–100%) for PFIQ‐7 and PFDI‐20. The corrected item–total correlations showed acceptable construct validity for PFIQ‐7 (r=0.338–0.826) but low for PFDI‐20 (r=0.116–0.581) and PISQ‐12 (r=0.024–0.735). Acceptable convergent validity was found in all three instruments, with a negative correlation with the SF‐12. There were no floor or ceiling effects in the three instruments. In the test–retest analysis, intraclass correlation coefficients were significant (r=0.888–0.943). Cronbach's α varied between 0.57 and 0.94. Conclusion. This is the first validated translation of the PFIQ‐7, PFDI‐20 and PISQ‐12 in Swedish. All three instruments indicated acceptable psychometric properties.