NWNana Wiberg

Nana Wiberg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nana Wiberg has a total of 56 co-authors. Here are the top co-authors by number of shared publications:

  • Linda Iorizzo

    Department of Clinical Sciences Lund Lund University Lund Sweden

    4 shared publications
  • Karin Källén

    Center for Reproductive Epidemiology, Tornblad Institute, University of Lund, Sweden

    3 shared publications
  • Karl Kristensen

    Department of Obstetrics and Gynecology, Skåne University Hospital, Malmö, Sweden

    3 shared publications
  • Parisa Mokarami

    Institution of Clinical Sciences Malmö, Department of Obstetrics and Gynecology, Skåne University Hospital, Lund University, Malmö, Sweden

    3 shared publications
  • Per Olofsson

    Department of Obstetrics and Gynecology, Institution of Clinical Sciences, Skåne University Hospital, Lund University, Malmö, Sweden

    3 shared publications
  • Per Olofsson

    A Department of Obstetrics and Gynecology , Institution of Clinical Sciences, Skåne University Hospital, Lund University , Malmö , Sweden

    3 shared publications

Latest Publications

  • Open Access

    Validation and proposal of a clinical intervention cutoff in fetal scalp blood for the point‐of care‐lactate meter StatStrip ® 2

    by Sofie Gellert, Sara Norrestam, Alexandra Tidstedt, Claes Ignell, Per‐Erik Isberg, Nana Wiberg, Linda Iorizzo

    Introduction: This multicenter, prospective observational study aimed to evaluate the performance of the StatStrip ® Lactate 2 (Nova Biomedical, Waltham, US) point‐of‐care device for fetal blood lactate measurement and to determine the corresponding lactate value equivalent to the established intervention cutoff used with the outgoing StatStrip ® Lactate device. Material and Methods: The study was conducted from August 2024 to February 2025 at two maternity clinics in Sweden and one in Denmark. It included women with singleton pregnancies (≥35 + 0 weeks) undergoing fetal blood sampling due to non‐reassuring intrapartal fetal heart rate patterns during labor. Fetal scalp blood sampling (FBS) lactate concentrations were measured using both StatStrip ® Lactate and StatStrip ® Lactate2. The first StatStrip ® Lactate measurement guided clinical decisions, while subsequent StatStrip ® Lactate2 measurements were recorded for validation and establishment of a conversion equation by linear regression. Additionally, arterial and venous umbilical cord blood samples were analyzed by both ABL 800 (Radiometer, Denmark) and StatStrip ® Lactate2 for validation. Results: Blood samples from 349 fetuses were included, with 549 parallel FBS lactate samples. StatStrip ® Lactate2 concentrations correlated with StatStrip ® Lactate ( r = 0.94; p ≤ 0.001). A conversion equation was retrieved: StatStrip ® Lactate2 = (1.4 × StatStrip ® Lactate) − 0.28. From 37 paired umbilical cord blood samples, the correlation between lactate concentrations by StatStrip ® Lactate2 and ABL800 was r = 0.99 ( p ≤ 0.001) in arterial blood and r = 0.98 ( p ≤ 0.001) in venous blood. Mean coefficients of variation for lactate concentrations >3.0 mmol/L were 8.2% in fetal scalp blood and 3.8% in umbilical cord blood. Conclusions: A fetal blood lactate concentration ≥7.0 mmol/L measured by StatStrip ® Lactate2 corresponds to the established intervention cutoff lactate value ≥5.2 mmol/L measured by StatStrip ® Lactate. Precision was acceptable but may be improved by using the mean of two measurements, particularly when the first result falls between 6.0 and 8.0 mmol/L. We also recommend ensuring the correct sampling techniques to minimize preanalytical variation.


  • Open Access

    Correlation between maternal and umbilical cord 25-hydroxy-vitamin D levels over a range of values. A prospective observational study from the United Arab Emirates

    by Magnus Jutell, Shakura Bhat, Maria Lindstrom Bagge, Per-Erik Isberg, Nana Wiberg

    Worldwide vitamin D insufficiency is remarkably prevalent in both children and adults, including pregnant women. The total amount of the vitamin is best measured by 25-hydroxy-vitamin D (25(OH)D), which is a measurement of total serum cholecalciferol 25(OH)D3 and ergocalciferol 25(OH)D2. There is a known correlation between maternal and umbilical cord blood (UCB) 25(OH)D; however, whether specific maternal demographics or comorbidities influence the correlation remains uncertain. This prospective observational study was designed to study if maternal 25(OH)D levels, maternal age and BMI, amount of supplementation, mode of delivery, diabetes, hypertension/preeclampsia, or sunlight exposure had an impact on the correlation. Women were enrolled in the study at admission to the labor ward. If they agreed to participate, venous blood was directly collected and analyzed for 25(OH)D. The UCB was sampled after delivery from the unclamped cord and immediately analyzed for 25(OH)D. ANOVA, Fisher’s exact test, Pearson’s correlation, and test of the differences between correlations using Fisher’s z-transformation with Bonferroni correction were used accordingly. Of the 298 women enrolled, blood from both the mother and umbilical cord was analyzed successfully for 25(OH)D in 235 cases. The crude correlation between maternal and UCB 25(OH)D was very strong over all values of 25(OH)D (r = 0.905, R2 = 0.821, p 2 ≥ 0.644, p 2 ≥ 0.4, p p = 0.02) and 20.000IU/week (p = 0.01) and that the correlation was significantly stronger for women with a BMI of 25–29.9 compared to women with a BMI of p = 0.004) and 30–34.9 (p = 0.002). 213 (91%) women had lower 25(OH)D compared to the neonate, with a mean difference of -13.7nmol/L (SD = 15.6). In summary, the correlation between maternal and UCB 25(OH)D is very strong throughout low to high maternal levels of 25(OH)D with lower levels in maternal blood. Typical maternal demographics and comorbidities did not affect the transition.


  • Open Access

    Proposed cutoff for fetal scalp blood lactate in intrapartum fetal surveillance based on neonatal outcomes: a large prospective observational study

    by L. Iorizzo, Y. Carlsson, C. Johansson, R. Berggren, A. Herbst, M. Wang, M. Leiding, P-E. Isberg, K. Kristensen, E. Wiberg-Itzel, et al.

    Objective: Determination of lactate in fetal scalp blood (FBS) during labour has been recognised since the 1970s. The internationally accepted cutoff of >4.8 mmol/l indicating fetal acidosis is exclusive for the point‐of‐care device (POC) LactatePro™, which is no longer in production. The aim of this study was to establish a new cutoff for scalp lactate based on neonatal outcomes with the use of the StatstripLactate®/StatstripXpress® Lactate system, the only POC designed for hospital use.Design: Observational study.Setting: January 2016 to March 2020 labouring women with indication for FBS were prospectively included from seven Swedish and one Australian delivery unit.Population: Inclusion criteria: singleton pregnancy, vertex presentation, ≥35+0 weeks of gestation.Method: Based on the optimal correlation between FBS lactate and cord pH/lactate, only cases with ≤25 minutes from FBS to delivery were included in the final calculations.Main outcome measures: Metabolic acidosis in cord blood defined as pH 10 mmol/l and/or lactate >10 mmol/l.Results: A total of 3334 women were enrolled of whom 799 were delivered within 25 minutes. The areas under the receiver operating characteristics curves (AUC) and corresponding optimal cutoff values were as follows; metabolic acidosis AUC 0.87 (95% CI 0.77–0.97), cutoff 5.7 mmol/l; pH ecf ≥12 mmol/l AUC 0.97 (95% CI 0.92–1), cutoff 5.8 mmol/l; Apgar score ®/StatstripXpress® system will safely rule out fetal metabolic acidosis.Tweetable Scalp blood lactate ®/StatstripXpress system has an excellent ability to rule out fetal acidosis.


  • Glycemic, maternal and neonatal outcomes in women with type 1 diabetes using continuous glucose monitoring during pregnancy – Pump vs multiple daily injections, a secondary analysis of an observational cohort study

    by Karin Kjölhede, Kerstin Berntorp, Karl Kristensen, Anastasia Katsarou, Nael Shaat, Nana Wiberg, Filip K. Knop, Lars Kristensen, Annika Dotevall, Anders Elfvin, et al.

    Introduction: Continuous glucose monitoring (CGM) provides detailed information about glucose level fluctuations over time. The method is increasingly being used in pregnant women with type 1 diabetes. However, only one previous study compared CGM results related to pregnancy outcomes in women using insulin pumps with those administering multiple daily injections (MDI). We performed a secondary analysis of CGM metrics from an observational cohort of pregnant women with type 1 diabetes and compared insulin pump and MDI therapies in relation to maternal and neonatal outcomes.Material and methods: The study included 185 pregnant Swedish women with type 1 diabetes undergoing CGM throughout pregnancy. Women were divided according to insulin administration mode, ie MDI (n = 131) or pump (n = 54). A total of 91 women used real‐time CGM and 94 women used intermittently viewed CGM. Maternal demographics and maternal and neonatal outcome data were collected from medical records. CGM data were analyzed according to predefined glycemic indices: mean glucose; standard deviation; percentage of time within, below and above glucose target range; mean amplitude of glycemic excursion; high and low glucose indices; and coefficient variation in percent. Associations between insulin administration mode and CGM data, on the one hand, and maternal and neonatal outcomes, on the other, were analyzed with analysis of covariance and logistic regression, respectively, adjusted for confounders.Results: There were no differences in maternal characteristics or glycemic indices between the MDI and pump groups, except for a longer duration of type 1 diabetes and higher frequencies of microangiopathy and real‐time CGM among pump users. Despite improvement with each trimester, glucose levels remained suboptimal throughout pregnancy in both groups. There were no differences between the MDI and pump groups concerning the respective associations with any of the outcomes. The frequency of large for gestational age was high in both groups (MDI 49% vs pump 63%) and did not differ significantly.Conclusions: Pregnant women with type 1 diabetes did not differ in glycemic control or pregnancy outcome, related to MDI or pump administration of insulin. Glycemic control remained suboptimal throughout pregnancy, regardless of insulin administration mode.


  • Open Access

    Maternal arterial blood gas values during delivery: Effect of mode of delivery, maternal characteristics, obstetric interventions and correlation to fetal umbilical cord blood

    by Mehreen Zaigham, Sara Helfer, Karl Heby Kristensen, Per‐Erik Isberg, Nana Wiberg

    Introduction: Obstetricians routinely use biochemical parameters from non‐pregnant women to assess the condition of the laboring mother. However, it is well known that pregnancy leads to significant physiological changes in most organ systems. The aim of this study was to determine normal values for maternal arterial blood gases during vaginal deliveries as compared with control values from planned cesarean sections. We also wanted to elucidate the effect of various maternal characteristics, mode of delivery and obstetric interventions on blood gas values.Material and methods: We carried out a randomly selected, prospective‐observational cohort study of 250 women undergoing vaginal delivery and 58 women undergoing planned cesarean section at the Department of Obstetrics and Gynecology, Skåne University Hospital, Malmö, Sweden.Results: We found significant differences for gestational age, parity, umbilical venous blood pH, pCO2 and lactate values between the two study groups (P < .005). Significantly lower pH, pCO2, pO2 and sO2 were found in mothers delivering vaginally. Higher base deficit, hemoglobin, bilirubin, potassium, glucose and lactate were found in vaginal deliveries than in planned cesarean sections (P < .02). Maternal body mass index (BMI), smoking and hypertension were not significantly correlated to acid base parameters in women with vaginal deliveries. On the other hand, multiple regression showed significant associations for the use of epidural anesthesia on maternal pH (P < .05) and pO2 (P < .01); and synthetic oxytocin on pCO2 (P = .08), glucose (P < .00) and lactate (P < .02) levels in maternal arterial blood. Maternal arterial pH, pCO2 and lactate values correlated significantly to values in venous umbilical cord blood (P < .000).Conclusions: Maternal arterial blood gas parameters varied significantly according to mode of delivery, the use of epidural anesthesia and synthetic oxytocin.


  • Open Access

    Maternal arterial blood values during delivery: effect of mode of delivery, maternal characteristics, obstetric interventions and correlation to fetal umbilical cord blood

    by Mehreen Zaigham, Sara Helfer, Karl Heby Kristensen, Per-Erik Isberg, Nana Wiberg

    Objective: To determine a reference interval for maternal arterial blood values during vaginal delivery and to elucidate the effect of common maternal characteristics and obstetric interventions on maternal acid base values during vaginal and planned cesarean section (CS). Design: Prospective, observational study of randomly selected women undergoing vaginal deliveries and planned CS at Skåne University Hospital, Malmö, Sweden. Results: Two hundred and fifty women undergoing vaginal delivery (VD) and fifty-eight women undergoing planned CS were recruited. We found significant differences for gestational age, parity, artery pH, pCO 2 , pO 2 , sO 2 and cord venous pH, pCO 2 and lactate between the two study groups ( P < 0.005). For women undergoing vaginal delivery, we found significant changes in base deficit, hemoglobin, bilirubin, potassium, glucose and lactate values as compared to women with planned CS ( P < 0.02). Maternal characteristics did not significantly affect acid base parameters however, multiple regression showed significant associations for the use of epidural anesthesia on maternal pH ( P < 0.05) and pO 2 ( P < 0.01); and synthetic oxytocin on pCO 2 ( P = 0.08), glucose ( P < 0.00) and lactate ( P < 0.02) in maternal blood. Maternal arterial pH, pCO 2 and lactate correlated significantly to values in venous umbilical cord blood ( P < 0.000). Conclusions: Reference values for maternal arterial blood gases in vaginal deliveries for term pregnancies were outlined and we found that most arterial blood gas parameters varied significantly according to mode of delivery. The use of different obstetrical interventions like epidural anesthesia or synthetic oxytocin, resulted in significant changes in blood gas values.

  • Arterio‐venous blood gas Δvalues for validation of umbilical cord blood samples at birth are not only biased by sample mix ups but also affected by clinical factors

    by Parisa Mokarami, Nana Wiberg, Karin Källén, Per Olofsson

    Introduction: Traditional validation of umbilical cord blood samples with positive veno‐arterial ΔpH and arterio‐venous ΔpCO2 values confirms the source of samples, whereas negative Δvalues represent mix‐up of samples. To investigate whether this is true, the distributions of V‐A ΔpO2 and A‐V Δlactate were also explored and related to clinical characteristics. In addition, different cord blood sampling techniques were evaluated.Material and methods: Register study with cord blood acid‐base and clinical data from 27 233 newborns. Clinical characteristics were related to positive, zero and negative Δvalues. Blood samplings from unclamped and double‐clamped cords were compared. A two‐sided P < 0.05 was considered significant.Results: ΔpH and ΔpCO2 values distributed into positive, around zero, and negative sub‐populations, with significant differences in pH and clinical characteristics between sub‐populations. No such sub‐populations were distinguished for ΔpO2 and Δlactate. The 2.5th and 5th ΔpH percentiles were 0.013 and 0.022, respectively, and for ΔpCO2 0.30 and 0.53 kPa. Applying 5th percentile criteria resulted in 3.5% of “approved” cases showing a ΔpO2 ≤ 0. Puncture and sampling of the unclamped cord resulted in significantly better sample quality.Conclusions: Unphysiological negative ΔpO2 values occurred despite correct validation with traditional criteria. Δlactate cannot be used for validation because both positive and negative values are physiological. Positive/around zero/negative ΔpH and ΔpCO2 sub‐populations were associated with significant differences in pH and clinical characteristics, indicating that defective sampling and sample handling are not the sole explanations for negative Δvalues. Prompt puncture and sampling of the unclamped cord resulted in best sample quality.


  • Open Access

    Infant outcome at four years of age after intrapartum sampling of scalp blood lactate for fetal assessment. A cohort study

    by Nana Wiberg, Tobias Wirenfeldt Klausen, Tobias Tyrberg, Lennart Nordström, Eva Wiberg-Itzel

    To correlate the value of lactate in fetal scalp blood at delivery and the outcomes of the offspring at four years of age. Cases where scalp blood lactate was taken within sixty minutes before delivery were identified from the randomized trial "Determination of pH or lactate in fetal scalp blood in management of intrapartum fetal distress”. Data were grouped according to the generally accepted cutoffs for normality, pre-acidemia, acidemia and concentrations above mean +2 SD during the second stage. The outcome measures included gross-/fine motor function, vision, hearing, speaking and cognitive disorders, signs of central motor damage and referral to specialized pediatric services. 307 cases were available for final analyse. With normal scalp lactate concentration, the number of children with a diagnosed disorder was lower compared to the pre-acidemic/acidemic groups, although the findings were only significant for fine motor dysfunction (p = 0.036). Elevated lactate values were significantly associated with increased risk for a poorer capacity of attention and understanding of instructions (OR 1.37, 95% CI 1.07–1.74), and for fine motor dysfunction (OR 1.22, 95% CI 1.00–1.49) at the age of four. Higher levels of lactate in fetal scalp blood seems to be associated with increased risk of an aberrant developmental outcome at four years of age in some areas.


  • Use of Lactate Pro TM 2 for measurement of fetal scalp blood lactate during labor – proposing new cutoffs for normality, preacidemia and acidemia: a cross-sectional study

    by L. Iorizzo, T. W. Klausen, E. Wiberg-Itzel, F. Ovin, N. Wiberg

    Objective: Measurement of fetal scalp blood lactate is a supplementary tool to cardiotocography in the case of a non-reassuring tracing. Several hand-held lactate meters have been launched, all with differentials in absolute values. Therefore, the reference intervals must be calculated for each device. The internationally accepted reference interval is based on measurement with Lactate ProTM with recently got out of production. The aim of this study was to propose cutoffs for normality, preacidemia, and acidemia in fetal scalp blood for Lactate ProTM2 based on the comparison of lactate values measured with Lactate ProTM and Lactate ProTM2. Design: Seven hundred one fetal scalp blood samples were analyzed simultaneously. The conversion equations were retrieved from the linear regression model. On the basis of the cutoffs for Lactate ProTM cutoffs for Lactate ProTM2 were calculated. Results: The conversion equations obtained were Lactate ProTM = −0.02 + 0.68 × Lactate ProTM2 (SD: −0.09–0.07 × Lactate ProTM2) and Lactate proTM2 (LP2) = 0.03 + 1.48 × Lactate ProTM (SD: 0.16 + 0.17 × Lactate ProTM). The correlation to umbilical arterial pH was identical for the two devices (r = −0.18), whereas the correlation to umbilical arterial lactate was better for Lactate ProTM than for Lactate ProTM2 (r = 0.38, respectively, r = 0.33). The correlation to umbilical arterial lactate was dependent on time from sampling to delivery. Conclusion: Proposed reference values for Lactate ProTM2: scalp lactate 7.1 mmol/L = acidemia, expedite delivery.