Diego Mateo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Diego Mateo has a total of 164 co-authors. Here are the top co-authors by number of shared publications:
- Josep Altet
Universitat Politcnica de Catalunya (UPC), Barcelona, Spain
30 shared publications - Xavier Aragones
Universitat Politecnica de Catalunya, Barcelona, Spain
26 shared publications - Enrique Barajas
Electronic Engineering Department, Universitat Politècnica de Catalunya–BarcelonaTech, 08034 Barcelona, Spain
12 shared publications A. Rubio
Electronic Engineering Department. Universitat Politecnica de Catalunya, Barcelona, Spain
11 shared publications- José Luis González
Université Grenoble-Alpes, CEA-Leti, Minatec Campus, Grenoble, France
10 shared publications - Xavier Perpina
Power Devices and Systems Group, IMB-CNM, CSIC, Barcelona, Spain
9 shared publications
Latest Publications
- Open Access
- 15 April 2026
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 405
Online monitoring of the aging degradation of the threshold voltage and mobility in a CMOS class-A amplifier with built-in temperature sensors
- 15 April 2026
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 405
Open AccessOnline monitoring of the aging degradation of the threshold voltage and mobility in a CMOS class-A amplifier with built-in temperature sensors
- 22 January 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1085
The AdvCam project: Designing the future cameras for the Large-Sized Telescopes of the Cherenkov Telescope Array Observatory
- 22 January 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1085
The AdvCam project: Designing the future cameras for the Large-Sized Telescopes of the Cherenkov Telescope Array Observatory
- Open Access
- 23 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Device and Materials Reliability
- Vol. 25 (1) , 11-16
High Sensitivity Temperature Measurements to Track and Compensate Aging Effects on CMOS Amplifiers
This article presents a method to monitor and compensate gain degradation produced by aging in linear CMOS amplifiers. The proposed procedure relies on a stand-alone temperature sensor circuit. DC measurements at the output of the temperature sensor allow to monitor high-frequency gain, and to select an adaptive biasing to keep a constant gain along the circuit lifetime. The approach is validated experimentally on a high-frequency Power Amplifier, which was subjected to an accelerated aging degradation. Experimental results demonstrate the capability to keep the amplifier gain within 0.3 dB from its fresh value, even after important device aging degradation.
- 23 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Device and Materials Reliability
- Vol. 25 (1) , 11-16
Open AccessHigh Sensitivity Temperature Measurements to Track and Compensate Aging Effects on CMOS Amplifiers
This article presents a method to monitor and compensate gain degradation produced by aging in linear CMOS amplifiers. The proposed procedure relies on a stand-alone temperature sensor circuit. DC measurements at the output of the temperature sensor allow to monitor high-frequency gain, and to select an adaptive biasing to keep a constant gain along the circuit lifetime. The approach is validated experimentally on a high-frequency Power Amplifier, which was subjected to an accelerated aging degradation. Experimental results demonstrate the capability to keep the amplifier gain within 0.3 dB from its fresh value, even after important device aging degradation.
- Open Access
Aging Compensation in a Class-A High-Frequency Amplifier with DC Temperature Measurements
One of the threats to nanometric CMOS analog circuit reliability is circuit performance degradation due to transistor aging. To extend circuit operating life, the bias of the main devices within the circuit must be adjusted while the aging degradation process affects them by using a monitor circuit that tracks the evolution of the circuit performance. In this paper, we propose the use of DC temperature measurements in the proximity of the circuit to perform the monitoring of circuit performance degradation and as an observable variable to adjust the bias of the main devices to restore the degraded performance to the original values. To this end, we present experimental results obtained from nine samples of a standard CMOS integrated circuit containing a high-frequency class-A power amplifier and a differential temperature sensor. After accelerated aging, the gain of the amplifier is degraded up to 50%. We propose two different procedures to perform DC temperature measurements that allow tracking of the amplifier gain degradation due to aging and, by uniquely observing temperature readings, automatically set a new bias for the amplifier devices that restores the original amplifier gain. Whereas one of the procedures is able to restore the gain up to a certain limit, the second allows full gain restoration.
Open AccessAging Compensation in a Class-A High-Frequency Amplifier with DC Temperature Measurements
One of the threats to nanometric CMOS analog circuit reliability is circuit performance degradation due to transistor aging. To extend circuit operating life, the bias of the main devices within the circuit must be adjusted while the aging degradation process affects them by using a monitor circuit that tracks the evolution of the circuit performance. In this paper, we propose the use of DC temperature measurements in the proximity of the circuit to perform the monitoring of circuit performance degradation and as an observable variable to adjust the bias of the main devices to restore the degraded performance to the original values. To this end, we present experimental results obtained from nine samples of a standard CMOS integrated circuit containing a high-frequency class-A power amplifier and a differential temperature sensor. After accelerated aging, the gain of the amplifier is degraded up to 50%. We propose two different procedures to perform DC temperature measurements that allow tracking of the amplifier gain degradation due to aging and, by uniquely observing temperature readings, automatically set a new bias for the amplifier devices that restores the original amplifier gain. Whereas one of the procedures is able to restore the gain up to a certain limit, the second allows full gain restoration.
- Open Access
BPF-Based Thermal Sensor Circuit for On-Chip Testing of RF Circuits
A new sensor topology meant to extract figures of merit of radio-frequency analog integrated circuits (RF-ICs) was experimentally validated. Implemented in a standard 0.35 μm complementary metal-oxide-semiconductor (CMOS) technology, it comprised two blocks: a single metal-oxide-semiconductor (MOS) transistor acting as temperature transducer, which was placed near the circuit to monitor, and an active band-pass filter amplifier. For validation purposes, the temperature sensor was integrated with a tuned radio-frequency power amplifier (420 MHz) and MOS transistors acting as controllable dissipating devices. First, using the MOS dissipating devices, the performance and limitations of the different blocks that constitute the temperature sensor were characterized. Second, by using the heterodyne technique (applying two nearby tones) to the power amplifier (PA) and connecting the sensor output voltage to a low-cost AC voltmeter, the PA’s output power and its central frequency were monitored. As a result, this topology resulted in a low-cost approach, with high linearity and sensitivity, for RF-IC testing and variability monitoring.
Open AccessBPF-Based Thermal Sensor Circuit for On-Chip Testing of RF Circuits
A new sensor topology meant to extract figures of merit of radio-frequency analog integrated circuits (RF-ICs) was experimentally validated. Implemented in a standard 0.35 μm complementary metal-oxide-semiconductor (CMOS) technology, it comprised two blocks: a single metal-oxide-semiconductor (MOS) transistor acting as temperature transducer, which was placed near the circuit to monitor, and an active band-pass filter amplifier. For validation purposes, the temperature sensor was integrated with a tuned radio-frequency power amplifier (420 MHz) and MOS transistors acting as controllable dissipating devices. First, using the MOS dissipating devices, the performance and limitations of the different blocks that constitute the temperature sensor were characterized. Second, by using the heterodyne technique (applying two nearby tones) to the power amplifier (PA) and connecting the sensor output voltage to a low-cost AC voltmeter, the PA’s output power and its central frequency were monitored. As a result, this topology resulted in a low-cost approach, with high linearity and sensitivity, for RF-IC testing and variability monitoring.
- 10 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 69 (2) , 1453-1463
Aging in CMOS RF Linear Power Amplifiers: An Experimental Study
An extensive experimental analysis of the hot carrier injection (HCI) and bias temperature instability (BTI) aging effects on RF linear power amplifiers (PAs) is presented in this article. Two different 2.45-GHz PA topologies have been implemented in a CMOS 65-nm technology: one based on a classical common-source (CS) and choke inductor and another one based on a complementary current-reuse (CR) circuit, both of them producing similar gain and output 1-dB compression point (P-1,dB). These circuits have been stressed to produce accelerated aging degradation, by applying increasing supply (VDD) voltages or increasing RF input powers (PIN). The degradation on the transistor parameters (threshold voltage and mobility), dc bias point (Idc current), and RF performance (gain, matching, and compression point) has been simultaneously measured. This has allowed us to observe how the reduced transistor degradation in CR PA results in higher robustness in its RF parameters compared with the CS PA circuit. The equivalent root-mean-square (rms) voltages have been proposed as an observable metric to assess the combined dc + RF stress in a PA circuit. This has been applied to a semianalytical model, providing comprehension of the link between the conditions under which a circuit is operated, the degradation of the transistor parameters, and the effects on the dc current and RF performance.
- 10 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 69 (2) , 1453-1463
Aging in CMOS RF Linear Power Amplifiers: An Experimental Study
An extensive experimental analysis of the hot carrier injection (HCI) and bias temperature instability (BTI) aging effects on RF linear power amplifiers (PAs) is presented in this article. Two different 2.45-GHz PA topologies have been implemented in a CMOS 65-nm technology: one based on a classical common-source (CS) and choke inductor and another one based on a complementary current-reuse (CR) circuit, both of them producing similar gain and output 1-dB compression point (P-1,dB). These circuits have been stressed to produce accelerated aging degradation, by applying increasing supply (VDD) voltages or increasing RF input powers (PIN). The degradation on the transistor parameters (threshold voltage and mobility), dc bias point (Idc current), and RF performance (gain, matching, and compression point) has been simultaneously measured. This has allowed us to observe how the reduced transistor degradation in CR PA results in higher robustness in its RF parameters compared with the CS PA circuit. The equivalent root-mean-square (rms) voltages have been proposed as an observable metric to assess the combined dc + RF stress in a PA circuit. This has been applied to a semianalytical model, providing comprehension of the link between the conditions under which a circuit is operated, the degradation of the transistor parameters, and the effects on the dc current and RF performance.
- Open Access
Differential Temperature Sensors: Review of Applications in the Test and Characterization of Circuits, Usage and Design Methodology
Differential temperature sensors can be placed in integrated circuits to extract a signature of the power dissipated by the adjacent circuit blocks built in the same silicon die. This review paper first discusses the singularity that differential temperature sensors provide with respect to other sensor topologies, with circuit monitoring being their main application. The paper focuses on the monitoring of radio-frequency analog circuits. The strategies to extract the power signature of the monitored circuit are reviewed, and a list of application examples in the domain of test and characterization is provided. As a practical example, we elaborate the design methodology to conceive, step by step, a differential temperature sensor to monitor the aging degradation in a class-A linear power amplifier working in the 2.4 GHz Industrial Scientific Medical—ISM—band. It is discussed how, for this particular application, a sensor with a temperature resolution of 0.02 K and a high dynamic range is required. A circuit solution for this objective is proposed, as well as recommendations for the dimensions and location of the devices that form the temperature sensor. The paper concludes with a description of a simple procedure to monitor time variability.
Open AccessDifferential Temperature Sensors: Review of Applications in the Test and Characterization of Circuits, Usage and Design Methodology
Differential temperature sensors can be placed in integrated circuits to extract a signature of the power dissipated by the adjacent circuit blocks built in the same silicon die. This review paper first discusses the singularity that differential temperature sensors provide with respect to other sensor topologies, with circuit monitoring being their main application. The paper focuses on the monitoring of radio-frequency analog circuits. The strategies to extract the power signature of the monitored circuit are reviewed, and a list of application examples in the domain of test and characterization is provided. As a practical example, we elaborate the design methodology to conceive, step by step, a differential temperature sensor to monitor the aging degradation in a class-A linear power amplifier working in the 2.4 GHz Industrial Scientific Medical—ISM—band. It is discussed how, for this particular application, a sensor with a temperature resolution of 0.02 K and a high dynamic range is required. A circuit solution for this objective is proposed, as well as recommendations for the dimensions and location of the devices that form the temperature sensor. The paper concludes with a description of a simple procedure to monitor time variability.
- 1 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21581525,p. 1-5
Aging in CMOS RF Linear Power Amplifiers: Experimental Comparison and Modeling
This paper characterizes experimentally the aging degradation experienced by two different 2.45 GHz power amplifier circuits of similar performance, implemented in a 65 nm CMOS technology. Results demonstrate the importance of the topology selection in order to guarantee robustness against aging effects, and thus the need to predict MOS parameter degradation during the design phase, accounting for the actual DC and RF operation conditions. For that purpose, we propose a semi-empirical compact model that, based on the RMS equivalent voltages at the transistor terminals during circuit operation, can provide an estimation of the aging degradation.
- 1 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21581525,p. 1-5
Aging in CMOS RF Linear Power Amplifiers: Experimental Comparison and Modeling
This paper characterizes experimentally the aging degradation experienced by two different 2.45 GHz power amplifier circuits of similar performance, implemented in a 65 nm CMOS technology. Results demonstrate the importance of the topology selection in order to guarantee robustness against aging effects, and thus the need to predict MOS parameter degradation during the design phase, accounting for the actual DC and RF operation conditions. For that purpose, we propose a semi-empirical compact model that, based on the RMS equivalent voltages at the transistor terminals during circuit operation, can provide an estimation of the aging degradation.
- 5 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 54 (2) , 476-488
A Versatile CMOS Transistor Array IC for the Statistical Characterization of Time-Zero Variability, RTN, BTI, and HCI
- 5 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 54 (2) , 476-488
A Versatile CMOS Transistor Array IC for the Statistical Characterization of Time-Zero Variability, RTN, BTI, and HCI
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 82-87
Analysis of Body Bias and RTN-Induced Frequency Shift of Low Voltage Ring Oscillators in FDSOI Technology
Electronic circuits powered at ultra low voltages (500 mV and below) are desirable for their low energy and power consumption. However, RTN (Random Telegraph Noise)-induced threshold voltage variations become very significant at such supply voltages. This paper evaluates the impact of RTN on additional jitter in a ring oscillator. Since FDSOI allows a large range of body bias voltages, this work studies how body biasing affects the oscillation frequency but also the jitter effects. The impact of RTN in NMOS and PMOS devices on frequency as well as the levels of supplementary jitter introduced by RTN are evaluated and compared with classical device noise.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 82-87
Analysis of Body Bias and RTN-Induced Frequency Shift of Low Voltage Ring Oscillators in FDSOI Technology
Electronic circuits powered at ultra low voltages (500 mV and below) are desirable for their low energy and power consumption. However, RTN (Random Telegraph Noise)-induced threshold voltage variations become very significant at such supply voltages. This paper evaluates the impact of RTN on additional jitter in a ring oscillator. Since FDSOI allows a large range of body bias voltages, this work studies how body biasing affects the oscillation frequency but also the jitter effects. The impact of RTN in NMOS and PMOS devices on frequency as well as the levels of supplementary jitter introduced by RTN are evaluated and compared with classical device noise.